As presented by Patrick W. Serruys, MD, PhD, FACC Principal Investigator Thoraxcentre - Erasmus University Rotterdam, The Netherlands PISCES Paclitaxel.

Slides:



Advertisements
Similar presentations
Clinical Trial Results. org ABSORB Presented at the American College of Cardiology Annual Scientific Session March, 2007 Presented by Dr. Patrick W. Serruys.
Advertisements

ENDEAVOR IV Acronym: ENDEAVOR IV. Lead investigator: Dr Martin Leon from Columbia University, New York Source: Transcatheter cardiovascular Therapeutics,
Copyleft Clinical Trial Results. You Must Redistribute Slides PEPCAD II ISR Study Paclitaxel-eluting devices: randomized comparison of the SeQuent™ please.
“Real World”: SVG, De Novo or Restenotic Coronary Artery Lesions Chronic Stable Angina, Silent Ischemia, Acute Coronary Syndromes Vessel Diameters:
M.Unverdorben; ACC March 2008 Martin Unverdorben Rotenburg/Fulda, Germany and Richmond, VA, USA Clinical Research Institute, Center for Cardiovascular.
PCI Unmet Clinical Needs
EXCELLA BD Randomized Trial 12-month Results
Www. Clinical trial results.org The RAVEL Study A RAndomised (double blind) study with the Sirolimus coated BX™ VElocity balloon expandable stent (CYPHER™)
Four Drug Eluting Stent Trials Keith D Dawkins MD FRCP FACC Southampton University Hospital Keith D Dawkins MD FRCP FACC Southampton University Hospital.
A PROSPECTIVE MULTICENTRE REGISTRY FOR THE ASSESSMENT OF SAFETY AND EFFICACY OF BIODEGRADABLE POLYMER COATED, PACLITAXEL ELUTING STENT LUC TM * *(BALTON,
2 Year Clinical Outcomes from the Pivotal RESOLUTE US Study Laura Mauri MD, MSc on behalf of the RESOLUTE US Investigators Brigham and Women’s Hospital.
29th ANNUAL SCIENTIFIC SESSIONS – SCA&I
University Hospital of Caen ClinicalTrials.gov Identifier: NCT
DIABETES trial P Jiménez-Quevedo, M Sabaté, DJ Angiolillo, JA Gómez-Hospital, R Hernández-Antolín, J Goicolea, F Alfonso, C Bañuelos, J Escaned, R Moreno,
Chaim Lotan MD, Yaron Almagor MD, Karel Kuiper MD, M.J. Suttorp MD, William Wijns MD The SICTO Study CYPHER TM Sirolimus-eluting stent in Chronic Total.
Meredith ● EVOLVE Primary Endpoint ● TCT 2011 ● San Francisco, CA Slide 1 Meredith ● EVOLVE overview ● TCT 2010 ● Washington, DC Slide 1 Clinical and Angiographic.
TITAX AMI Trial Y. Giraud-Sauveur on behalf of P.Karjalainen, MD, PhD : Principal Investigator BCIS 2009 London, UK A Prospective, Randomized Trial Comparing.
Welcome Ask The Experts March 24-27, 2007 New Orleans, LA.
The REALITY Study Results. REALITY Study Design The REALITY Study : Prospective randomized clinical trial to evaluate the safety and efficacy of CYPHER®
As presented by Keith D Dawkins MD FRCP FACC Southampton University Hospital United Kingdom EuroSTAR The European Cobalt Stent with Antiproliferative for.
Rapamycin- and Paclitaxel-Eluting Stents With Identical Biodegradable Polymeric Coating and Design Trial Presented at The American College of Cardiology.
AICT 2010-Athens Interventional Cardiovascular Therapeutics XI 8-9 OCTOBER 2010 Divani Caravel Hotel, Αthens EARLY CLINICAL OUTCOMES AFTER PROMUS ELEMENT.
Treatment of In-Stent Restenosis by Paclitaxel Coated PTCA Balloons Presented at The American Heart Association Scientific Session 2006 Presented by Dr.
SIROLIMUS-ELUTING STENTS EFFECTIVELY INHIBIT NEOINTIMAL PROLIFERATION AS COMPARED TO BARE METAL STENTS IN DISEASED SAPHENOUS VEIN GRAFTS: 6-month IVUS.
TAXUS ATLAS Trial Presented at The EuroPCR meeting Paris, France May 2006 Presented by Dr. Mark Turco TAXUS ATLAS 9-Month Results: Evaluation of TAXUS.
FRONTIER Registry The Guidant MULTI-LINK FRONTIER ™ Coronary Stent System for the Treatment of Pts with Native De Novo or Restenotic Bifurcation Coronary.
LONG-TERM OUTCOMES OF PERCUTANEOUS CORONARY INTERVENTION FOR UNPROTECTED LEFT MAIN CORONARY ARTERY DISEASE: INITIAL CLINICAL EXPERIENCE. Graidis Ch. 1,
Slow-rate release polymer-based paclitaxel- eluting stent compared with bare stent in patients with single complex coronary lesions TAXUS V Presented at.
A Prospective, Randomized Trial Evaluating a Paclitaxel-Eluting Balloon in Patients TReated with Endothelial Progenitor Cell CapTuring Stents for De Novo.
EuroSTAR II The European Randomized CoStar Trial: Cobalt-Chromium Paclitaxel-eluting Stent vs. identical BMS EuroSTAR II The European Randomized CoStar.
Prospective, Randomized Trial of Paclitaxel-Eluting Balloon versus Paclitaxel-Eluting Stent versus Balloon Angioplasty for Treatment of Coronary Restenosis.
Robert A. Byrne, MB MRCPI Deutsches Herzzentrum and 1. Med. Klinik rechts der Isar, Technische Universität Munich, Germany A Polymer-Free Dual Drug-Eluting.
Clinical Experience with the Bio Active Stent (BAS) in FINLAND 9 e CFCI Hotel Meridien Etoile Paris, France 10 Octobre 2007 Pasi Karjalainen, MD, PhD.
Endeavor 4: A Randomized Comparison of a Zotarolimus- Eluting Stent and a Paclitaxel- Eluting Stent in Patients with Coronary Artery Disease Martin B.
Www. Clinical trial results.org Cypher sirolimus-eluting stent Primary Endpoint:  In-stent and late lumen loss at 9 months (determined by QCA) Secondary.
Effect of Intravascular Ultrasound- Guided vs. Angiography-Guided Everolimus-Eluting Stent Implantation: the IVUS-XPL Randomized Clinical Trial Myeong-Ki.
The GENESIS Trial: 6-Month Results A Randomized, Multi-center Study of the Pimecrolimus-Eluting and Paclitaxel-ElutinG Coronary Stent System in PatiENts.
Boston Scientific Drug eluting stent program A Scientific Approach Identify therapeutic agent Identify appropriate polymer carrier Evaluate a broad range.
Disclosure Statement of Financial Interest
A Prospective, Randomized Trial of a Paclitaxel coated Balloon vs. uncoated Balloon Angioplasty in Patients with Drug- Eluting Stent Restenosis PEPCAD-DES.
RAVEL 4 YEAR FOLLOW-UP - Cordis Cardiology / Cardialysis – Euro-PCR – Sousa – 24 May 2005 RAVEL A RAndomised, double-blind study with the Sirolimus-eluting.
NEXT A Prospective, Randomized Trial Comparing Cre8, a Polymer-Free Stent Eluting Sirolimus, to a Paclitaxel-Eluting Stent Didier Carrié, MD,PhD On behalf.
The OPTIMAX first-in-man study Mid-term clinical outcome of Titanium-Nitride-Oxide-coated Cobalt Chromium stents in patients with de novo coronary artery.
Ospedale San Raffaele, Milan, Italy
A Novel Abluminal Coated Sirolimus-Eluting Stent as a Treatment Option for Diabetic Patients: Results from an All-Comers Multi-center Study: the En-ABL.
LONG-DES II Trial Randomized Comparison of the Efficacy of Sirolimus-Eluting Stent Versus Paclitaxel-Eluting Stent in the Treatment of Long Native Coronary.
TAXUS IV Trial Slow-rate release polymer-based paclitaxel-eluting stent compared with bare stent in patients with single de novo coronary lesions Presented.
Novolimus Elution from a Biodegradable Polymer Coated Coronary Stent
EXCELLA Studies - Novolimus Elution from PLLA Polymer Coated Stents DESyne® and DESyne BD: Design Specifications and Clinical Updates Stefan Verheye,
Stenting of Coronary Arteries in Non Stress/Benestent Disease
Two-Year Extended Follow-up in Patients Receiving a Zotarolimus-eluting Stent in the E-Five Registry Martin T. Rothman, Ian T. Meredith, Keyur Parikh,
TAXUS II and IV: two-year follow-up
American College of Cardiology Presented by Dr. Stephan Windecker
REALITY: 8 month results
Kyoto University Hospital, Japan
3-Year Clinical Outcomes From the RESOLUTE US Study
ENDEAVOR IV: 5 Year Final Outcomes
Presented at ACC 2003 Late Breaking Clinical Trials
The American College of Cardiology Presented by Dr. Raimund Erbel
Large-Scale Registry Examining Safety and Effectiveness of Zotarolimus-Eluting and Sirolimus-Eluting Stents in Patients with Coronary Artery Disease Western.
SIRIUS: A U.S. Multicenter, Randomized, Double-Blind Study of the SIRolImUS-Eluting Stent in De Novo Native Coronary Lesions Presented at TCT 2002.
Incidence and management of restenosis after treatment of unprotected left main disease with drug-eluting stents: 70 restenotic cases from a cohort of.
Gregg W. Stone, MD Columbia University Medical Center
ENDEAVOR III Multicenter Randomized Trial Clinical/MACE Angio/IVUS
Presented at TCT 2006.
Long Term Clinical Results from the Endeavor Program: 5-Year Follow up
Maintenance of Long-Term Clinical Benefit with
ISAR-LEFT MAIN: A Randomized Clinical Trial on Drug-Eluting Stents for Unprotected Left Main Lesions J. Mehilli, MD Deutsches Herzzentrum Technische.
ISAR-LEFT MAIN: A Randomized Clinical Trial on Drug-Eluting Stents for Unprotected Left Main Lesions J. Mehilli, MD Deutsches Herzzentrum Technische.
The American College of Cardiology Presented by Dr. A. Abazid
Presentation transcript:

As presented by Patrick W. Serruys, MD, PhD, FACC Principal Investigator Thoraxcentre - Erasmus University Rotterdam, The Netherlands PISCES Paclitaxel In-Stent Controlled Elution Study 4 and 12-Month Results

Bridge Elements Reservoirs Reservoirs Ductile Hinges CoStar™ Stent Design CoStar ™ Paclitaxel-Eluting Coronary Stent System Clinical Trials A Stent Designed Specifically for Controlled and Targeted Drug Delivery

Conor Stainless Steel and Cobalt Chromium Stents Characteristic MedStent* Stainless Steel CoStar ™ Cobalt Chromium Design576 Reservoirs (17mm stent) 492 Reservoirs (17mm stent) Alloy316L Stainless SteelL605 Cobalt Chromium Strut Thickness inch inch Crossing Profile (3.0mm Stent) inch0.039 inch RadiopacityExcellent Polymer Type85/15 PLGA Polymer Volume515 µg347 µg * MedStent was the study stent for the PISCES trial

PISCES – Paclitaxel In-Stent Controlled Elution Study Study Purpose: To evaluate safety and performance of the Conor MedStent ™ and determine optimal dosing of Paclitaxel in a prospective, multi-center, sequentially enrolled study involving 6 different release formulations. The proposed intended use of the MedStent is to improve and maintain arterial lumen diameter in patients with ischemic heart disease in native coronary arteries with de novo lesions.

PISCES Trial Study Design & Patient Follow-Up * Bi-Directional = direction of paclitaxel elution is both mural and luminal + 12 Month Angiography w/ QCA and IVUS was optional D 1 D 1 10 µg / 5 days Bi-Directional* Release N = 30 patients D 2 10 µg / 10 days Mural Release N = 30 patients D 3 10 µg / 10 days Bi-Directional* Release N = 29 patients D 4 10 µg / 30 days Mural Release N = 39 patients D 5 30 µg / 30 days Mural Release N = 29 patients D 6 30 µg / 10 days Bi-Directional* Release N = 30 patients Treatment Arms 1 Month Clinical 4 Month Clinical 4 Month Angiographic with QCA & IVUS 1 Year Clinical Baseline Angiography Baseline Angiography 12 Month Angiographic with QCA & IVUS + Dose Ranging Study

PISCES Trial Study Endpoints Safety Endpoint: A composite of MACE at 4 months Efficacy Endpoints: Late Loss by QCA within the stent % Stent Volume Obstruction by IVUS Rate of Binary Restenosis The data is presented as “intent to treat”.

Participating Investigators & Centers 31RotterdamP.W. Serruys 1KreuzlingenM. Pieper 23EindhovenH. Bonnier 12Rotterdam ZuidA. G. de Vries 7CaracasJ. A. Condado 191 Total 8Buenos AiresJ. Belardi 10AntwerpS. Verheye 11New ZealandD. McClean 26BredaP. den Heijer 62Sao Paolo J. E. Sousa / A. Abizaid Patients EnrolledSite LocationInvestigator

Risk Factors per Dose D1D2D3D4D5D6Total Dose/ Duration/ Direction 10/5/b10/10/m10/10/b10/30/m30/30/m30/10/b N=30N=31N=30N=31N=39N=30 N=191 DM, % HT, % Dyslip, % Prior MI, % Prior PCI, % D1D2D3D4D5D6Total Dose/ Duration/ Direction 10/5/b10/10/m10/10/b10/30/m30/30/m30/10/b N=30N=31N=30N=31N=39N=30 N=191 DM, % HT, % Dyslip, % Prior MI, % Prior PCI, % Release Direction: b = bi-directional, m = mural

Number of Patients191 Patients Total Lesions Treated187 Lesions Total Number of CoStar ™ Stent Implanted209 Stents Average Number of Stents per Patient1.1 Average Number of Stents per Lesion1.1 Direct Stenting per Lesion51.0% Procedural Success92.7% Device / Technical Success95.3% PISCES Trial Procedural Data

N = 191 Patients Age in Years (mean ± SD) 59.1 ± 9.2 Gender (% Male) 70.2 (134) History of Smoking 76.0% (145) Diabetes Mellitus 18.8% (36) Hypertension 52.9% (101) Dyslipidemia 66.0% (126) Prior MI 38.2% (73) Prior CABG 2.6% (5) Prior PCI 12.0% (23) PISCES Trial Baseline Patient Demographics

N = 187 Lesions Target Lesion Location LAD RCA LCX 46.0% (86) 31.6% (59) 22.6% (42) Reference Vessel Diameter mm Lesion Length (visual) mm Percent Diameter Stenosis (visual)80.0% % ACC Classification A B1 / B2 C 26.2% (49) 72.1% (135) 1.6% (3) PISCES Trial Baseline Lesion Demographics

C Proximal D 5 mm 17 mm 5 mm In-Stent Peri-Stent Total Vessel Side Branch Distal vessel QCA Analysis - Methodology

In-Stent Binary Restenosis at 4 Months % N=26 N=38 N=43 N=29 N=28N=28 N= D0D1D2D3D4D5D6 10/5/b10/10/bBare10/10/m 10/30/m 30/10/b 30/30/m

In-Stent Binary Restenosis at 4 and 12 Months Cumulative % N=18 N= /30/m30/30/m

In-Stent Late Loss at 4 Months (mm) N=26 N=38 N=43 N=29 N=28N=28 N=29 10/5/b10/10/bBare10/10/m 10/30/m 30/10/b30/30/m

(mm) In-Stent Late Loss at 4 and 12 Months Serial Analysis p=0.01 p=0.53 N=32N=18 Late loss of patients undergoing TLR at 4 months (D5=0, D6=1) is imputed as the value of late loss at 12 months.10/30/m30/30/m

Neo-Intimal Volume at 4 Months (mm 3 ) N=21 N=37 N=39 N=28 N=27N=23 N=26 10/5/b10/10/bBare10/10/m 10/30/m 30/10/b30/30/m

Neo-Intimal Volume at 4 and 12 Months Serial Analysis (mm 3 ) p= p=0.29 N=15 N=3010/30/m30/30/m

In-Stent % Volume Obstruction at 4 Months % N=21 N=37 N=39 N=28 N=27N=23 N=26 10/5/b10/10/bBare10/10/m10/30/m30/10/b 30/30/m

In-Stent % Volume Obstruction at 4 and 12 Months Serial Analysis % p=0.0004p=0.31 N=15 N=30 10/30/m30/30/m

MACE at 4 and 12 Months % Between 4 and 12 months, 1 non Q-wave MI occurred in D5 in a non- target vessel and 1 Q-wave MI (total occlusion of target lesion) in D /5/b10/10/bBare10/10/m 10/30/m 30/10/b30/30/mN=29 N=39 N=50 N=30 N=30N=29 N=30

TLR at 4 and 12 Months % 10/30/m N=29 N=39 N=50 N=30 N=30 N=29 N= /30/m

Proximal and Distal Edge Late Loss at 4 and 12 Months - Serial Analysis p=0.44 p=0.97 p=0.10 p=0.69 D5 D proximaldistal

Conclusions  This study represents one of the most comprehensive analyses of pharmacokinetic releases ever performed in a FIM Study.  The safety profile of this system - using an erodable polymer and delivering 100% of the drug is within the accepted standards.  Protocol called for 6 months Plavix therapy. There were no reported cases of delayed stent thrombosis in the interval period.  Although the doses used were substantially less than paclitaxel-coated stents, the inhibition of neo-intimal hyperplasia was similar.

Conclusions  In the 2 long release (most effective) formulations the TLR and MACE rates remained low at 12 months.  In D5, there was 0% in stent restenosis at both 4 and 12 months and in D6 the restenosis rate remained 5.6%.  There was a modest but statistically significant increase in neo-intimal volume, % in-stent obstruction and late loss between 4 months and 12 months in D5 but not in D6. The TLR and restenosis rates in the D6 group were not as good as in D5.  These 2 pharmacokinetic profiles are currently under investigation in the Eurostar trial with a thin strut cobalt chromium stent and 33% less polymer volume.