1 CISCO NETWORKING ACADEMY PROGRAM (CNAP) SEMESTER 1/ MODULE 4 Cable Testing.

Slides:



Advertisements
Similar presentations
Physical Layer: Signals, Capacity, and Coding
Advertisements

Cisco CCNA Sem 1 Chapter 4 Cable Testing, Cabling LAN’s and WAN’s
1 © 2003, Cisco Systems, Inc. All rights reserved. CCNA 1 v3.0 Module 4 Cable Testing.
Cable Testing.
SUNY Ulster Cisco Semester 1 Unit 4 – Cable Testing K. Wick CCAI.
CCNA 1 v3.1 Module 4 Cable Testing. Purpose of This PowerPoint This PowerPoint primarily consists of the Target Indicators (TIs) of this module in CCNA.
1 © 2004, Cisco Systems, Inc. All rights reserved. CCNA 1 v3.1 Module 4 Cable Testing.
DCN286 Introduction to Data Communication Technology Session 5.
Chapter Fourteen: Transmission Lines
1 Transmission Fundamentals Chapter 2 (Stallings Book)
Chapter-3-1CS331- Fakhry Khellah Term 081 Chapter 3 Data and Signals.
ECE 4321: Computer Networks Chapter 3 Data Transmission.
Testing.
EE 4272Spring, 2003 Chapter 3 Data Transmission Part II Data Communications Concept & Terminology Signal : Time Domain & Frequency Domain Concepts Signal.
1 Telecom Cabling Testing and cable certification.
Chapter 3 Data and Signals
Oct-03 ©Cisco Systems CCNA Semester 1 Version 3 Comp11 Mod4 – St. Lawrence College – Cornwall Campus, ON, Canada – Clark slide 1 Cisco Systems CCNA Version.
Department of Electronic Engineering City University of Hong Kong EE3900 Computer Networks Data Transmission Slide 1 Continuous & Discrete Signals.
How To Determine The Integrity of an Ethernet Line Design Team 7 Mark Jones Sedat Gur Ahmed Alsinan Brian Schulte Andy Christopherson.
Network+ Guide to Networks, Fourth Edition Chapter 3 Transmission Basics and Networking Media.
William Stallings Data and Computer Communications 7th Edition (Selected slides used for lectures at Bina Nusantara University) Data, Signal.
Module 3.0: Data Transmission
Lecture 4b Fiber Optics Communication Link 1. Introduction 2
3.1 Chapter 3 Data and Signals Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
1 Version 3.0 Module 4 Cable Testing. 2 Version 3.0 Waves Networking professionals are interested in voltage waves on copper media, light waves in optical.
Measuring Frequency The amplitude of an electrical signal represents height and is measured in volts. The period is the amount of time to complete one.
Copyright CCNA 1 Chapter 4, Part 1 Cable Testing By Your Name.
CCNA 1 v3.0 Module 4 Cable Testing. Purpose of This PowerPoint This PowerPoint primarily consists of the Target Indicators (TIs) of this module in CCNA.
4 Semester 1 CHAPTER 4 REVIEW JEOPARDY Presented by: Terren L. Bichard.
CCNA 1 Module 4: Cable Testing.
1 Semester 1 Module 4 Cable Testing Andres, Wen-Yuan Liao Department of Computer Science and Engineering De Lin Institute of Technology
Electronics and Signals Chapter 4. Parts of an Atom nucleus - the center part of the atom, formed by neutrons and protons nucleus - the center part of.
DCN286 INTRODUCTION TO DATA COMMUNICATION TECHNOLOGY Network Cable Testers and Tests.
Cisco 1 - Networking Basics Perrine. J Page 19/3/2015 Chapter 3 Which of the following correctly describes the type of signal that the network media carries?
Mod 4 – Cable Testing CCNA 1.
Chapter 2.  Types of Network  Circuit Switched & Packet Switched  Signaling Techniques  Baseband & Broadband  Interference  Transmission Medium.
1 Business Telecommunications Data and Computer Communications Chapter 3 Data Transmission.
1 CCNA SEMESTER 1 V 3.0 CHAPTER 4 – Cable testing.
1 Electronics & Signals Honolulu Community College Cisco Academy Training Center Semester 1 Version
NESCOT CATC1 Cable Testing CCNA 1 v3 – Module 4. NESCOT CATC2 Waves 1. The _________ of the waves is the amount of time between each wave, measured in.
CE 4228 Data Communications and Networking
Physical Transmission
ECEN 621, Prof. Xi Zhang ECEN “ Mobile Wireless Networking ” Course Materials: Papers, Reference Texts: Bertsekas/Gallager, Stuber, Stallings,
Networking Fundamentals Copper Core Cable as Network Media.
Cisco 1 - Networking Basics Perrine. J Page 110/16/2015 Chapter 4 Which of the following best describes a digital signal? 1.A sine wave of normal shape.
Bits (0s and 1s) need to be transmitted from one host to another. Each bit is placed on the cable as an electrical signal or pulse. On copper cable the.
CCNA 1 Module 4 Cable Testing. 2 Waves Frequency: Frequency: –the number of waves per second Period: Period: –the amount of time that it takes to complete.
1 ELE5 COMMUNICATIONS SYSTEMS REVISION NOTES. 2 Generalised System.
IT-101 Section 001 Lecture #19 Introduction to Information Technology.
Sep-03 ©Cisco SystemsCCNA Semester 1 Version 3 Comp11 Mod4 – St. Lawrence College – Cornwall Campus – Clark slide 1.
CCNA 1 v3.0 Module 4 Cable Testing. Objectives Waves.
Physical Layer PART II. Position of the physical layer.
CCNA1 v3 Module 4 v3 CCNA 1 Module 4 JEOPARDY S Dow.
Channels of Communication HL – Option F.4 Mr. Jean April 22 nd, 2014.
FUNDAMENTALS OF NETWORKING
Cisco CCNA Semester 1 Chapter 4 V3.0 By: Terren L. Bichard.
Cisco Semester 1 Chapter 4 Slides Cable Testing
Module 4 Cable Testing.
Lesson 2—Networking BASICS1 Networking BASICS Network Media Unit 1 Lesson 2.
Network Media. Copper, Optical, Fibre (Physical Layer Technologies) Introduction to Computer Networking.
TOPIC 1.2 INTRODUCTION TO NETWORKING. OBJECTIVES By the end of the topic, students should be able to: a) List the elements of data communication systems.
Attenuation is the loss of signal strength, for example, when cables exceed a maximum length. This means that a 1 bit voltage signal loses amplitude as.
By: Thomas Olivotti.  PSNEXT stands for Power Sum Near End Crosstalk and is calculated by transmitting a signal down each wire pair in turn and summing.
Chapter Four Networking Media. Chapter Objectives  Explain concepts related to data transmission and noise  Describe the physical characteristics of.
Pertemuan 10 Signal & Noise
Module 4 Cable Testing.
James Chen Module 4: Cable Testing James Chen 2018/11/10 Yuda college of business.
CCNA 1 version 3.0 Rick Graziani Cabrillo College
CCNA 1 v3.1 Module 4 Cable Testing
CCNA 1 v3.1 Module 4 Cable Testing
Presentation transcript:

1 CISCO NETWORKING ACADEMY PROGRAM (CNAP) SEMESTER 1/ MODULE 4 Cable Testing

2 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 1 Introduction to Networking Objectives Upon completion of this module, students will be able to perform tasks related to the following: Background for Studying Frequency-Based Cable Testing Signals and Noise

3 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Sine Waves or sinusoids are graphs of mathematical functions are periodic (repeat the same pattern at regular intervals) are continuously varying (no two adjacent points on the graph have the same value) represent analog signal

4 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Square Waves like sine waves, are periodic Square wave graphs do not continuously vary with time The wave holds one value for some time, and then suddenly changes to a different value Square waves represent digital signals, or pulses

5 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Decibels The decibel (dB) is a measurement unit important in describing networking signals There are two formulas for calculating decibels: dB = 10 log 10 (P final / P ref ) dB = 20 log 10 (V final / V reference ) The variables represent the following values: dB measures the loss or gain of the power of a wave. Decibels are usually negative numbers representing a loss in power but can also be positive values representing a gain in power if the signal is amplified P final is the delivered power measured in Watts P ref is the original power measured in Watts V final is the delivered voltage measured in Volts V reference is the original voltage measured in Volts light waves on optical fiber and radio waves in the air are measured using the power formula. Electromagnetic waves on copper cables are measured using the voltage formula

6 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Viewing Signals in Time & Frequency Oscilloscope Used to view electrical signals such as voltage waves and pulses The x-axis on the display represents time, and the y-axis represents voltage or current Analyzing signals using an oscilloscope is called time-domain analysis, because the x- axis or domain of the mathematical function represents time Spectrum analyzer Creates graphs for frequency-domain analysis Analyzing signals using spectrum analyzer is called frequency-domain analysis, The x-axis represents frequency

7 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Noise in Time & Frequency Noise related to communications refers to undesirable signals Noise can originate from natural and technological sources, and is added to the data signals in communications systems. There are many possible sources of noise: Nearby cables which carry data signals Radio frequency interference (RFI), which is noise from other signals being transmitted nearby Electromagnetic interference (EMI), which is noise from nearby sources such as motors and lights Laser noise at the transmitter or receiver of an optical signal

8 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Attenuation and Insertion Loss on Copper Media Attenuation is the decrease in signal amplitude over the length of a link is expressed in decibels (dB) using negative numbers Impedance Discontinuity Impedance is a measurement of the resistance of the cable is measured in ohms If a connector is improperly installed on cable, it will have a different impedance value than the cable, called an impedance discontinuity or an impedance mismatch Multiple discontinuities creating multiple echo effects The echoes strike the receiver at different intervals making it difficult for the receiver to accurately detect data values on the signal, called jitter and results in data errors Insertion Loss is the combination of the effects of signal attenuation and impedance discontinuities on a communications link

9 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Source of Noise on Copper Media

10 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Types of Crosstalk Near-end Crosstalk (NEXT) - interference from adjacent wire or separate nearby cable measured from the same end expressing in a negative value of decibels (dB), low negative numbers indicate more noise by tradition, cable testers do not show the minus sign indicating the negative value, for example a NEXT reading of 30 dB (really -30) indicates less NEXT noise than does a NEXT reading of 10 dB (really -10)

11 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Types of Crosstalk Far-end Crosstalk (FEXT) - crosstalk occurring further away from the transmitter creates less noise on a cable than NEXT because of attenuation, FEXT creates less noise on a cable than NEXT

12 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Types of Crosstalk Power Sum Near-end Crosstalk (PSNEXT) - measures the cumulative effect of NEXT from all wire pairs in the cable

13 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Cable Testing Standard The TIA/EIA-568-B standard specifies ten tests that a copper cable must pass The ten primary test parameters that must be verified for a cable link to meet TIA/EIA standards are: Wire map, Insertion loss, Near-end crosstalk (NEXT), Power sum near-end crosstalk (PSNEXT), Equal-level far-end crosstalk (ELFEXT), Power sum equal-level far-end crosstalk (PSELFEXT), Return loss, Propagation delay, Cable length, Delay skew The wire map - test insures that no open or short circuits exist on the cable and also verifies that all eight wires are connected to the correct pins on both ends of the cable

14 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Other Test Parameters Insertion loss - combination of signal attenuation and impedance discontinuities Near-end crosstalk (NEXT) - interference from adjacent wire Power sum near-end crosstalk (PSNEXT) - measures the cumulative effect of NEXT Equal-level far-end crosstalk (ELFEXT) - crosstalk occurring further away from the transmitter Power sum equal-level far-end crosstalk (PSELFEXT) - measures the cumulative effect of FEXT Return loss - is a measure in decibels of reflections that are caused by the impedance discontinuities Propagation delay - measurement of how long it takes for a signal to travel along the cable being tested Cable length Delay skew - The delay difference between pairs

15 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Testing Optical Fiber Because noise, crosstalk, Electromagnetic Interference (EMI) or Radio Frequency Interference (RFI) has no effect on fiber optic cable, so the primarily test involves shining a light down the fiber and measuring whether a sufficient amount of light reaches the receiver

16 CISCO NETWORKING ACADEMY PROGRAM SEMESTER 1/ MODULE 4 Cable Testing Summary