THE SINGLE-USE INSTRUMENT SURVEILLANCE PROGRAMME (SISP) AS A MODEL SYSTEM FOR THE INTRODUCTION OF DISPOSABLE INSTRUMENTATION AND NEW SURGICAL PROCEDURES.

Slides:



Advertisements
Similar presentations
The Role of Welsh Health Libraries in Supporting Information Provision to NHS Users Anne Cleves AWHILES Conference 14 th July 2009.
Advertisements

Hip fracture NICE quality standard March 2012 ABOUT THIS PRESENTATION:
Patient safety and reduction of risk of transmission of Creutzfeldt–Jakob disease (CJD) via interventional procedures 2008 Implementing NICE guidance NICE.
Local Improvement following National Clinical Audit The View from a National Clinical Audit Provider – the Health & Social Care Information Centre.
MHRA - November 2006 Medical Device Management Are single-use devices a special case? Alun Tomkinson Consultant Otolaryngologist, University Hospital Wales,
Standard 6: Clinical Handover
Registration Update GT Training Day Bristol 20 November 2014 GT Training Day Bristol 20 November 2014.
A feasibility study to explore patient, clinician and GP decision making of acute recurrent tonsillitis for NATTINA: The NAtional Trial of Tonsillectomy.
Slides produced by the MBR Project Team
Subjects eligible for this study were post treatment, disease free head and neck cancer patients undergoing routine follow-up visits for surveillance.
The Health Roundtable Osteoarthritis Chronic Care Program (OACCP) Presenter: Matthew Jennings Hospital Code Name: Innovation Poster Session HRT1215 – Innovation.
Governance and quality Ian Sharp November 2006 Aims of the presentation To highlight the importance of quality management and quality assurance in the.
Line Efficiency     Percentage Month Today’s Date
PRESENTATION ON SAFETY ISSUES RELEVANT TO HOME BIRTHS AND THE PROFESSIONALS WHO PROVIDE MATERNITY CARE SEPTEMBER 20, 2012 The Maryland Chapter of the American.
The Health Roundtable 3-3b_HRT1215-Session_MILLNER_CARRUCAN_WOOD_ADHB_NZ Orthopaedic Service Excellence – Implementing Management Operating Systems Presenter:
Successful Implementation of Vendor-Managed Inventory at a Major Teaching Hospital Tsui M, 1 Wilson DI, 2,3 Merry H, 4 Phulwani K, 1 Dooley MJ 1,5 1) Pharmacy.
Support and Assessment for Fall Emergencies (SAFE) Trial An evaluation of the costs and benefits of computerised on-scene decision support for emergency.
Benefits for using a standardised risk management framework to risk assess Infection Prevention and Control Sue Greig Senior Project Officer National.
The National Mastectomy and Breast Reconstruction Audit Key findings of the Third Annual Report Slides produced by the MBR Project Team. © The National.
Impact of the Pneumococcal Conjugate Vaccines (PCV) on the burden of invasive pneumococcal disease (IPD) in Ireland Data source: National Pneumococcal.
Results Conclusions Good compliance with writing TTOs however there is room for improvement with adherence to filling in certain information parameters.
TEMPLATE DESIGN © Audit of the Enhanced Recovery Programme for Hysterectomy at West Middlesex University Hospital Background.
Revised for 2013 Shannon Hein RN, CPN(C).  published in the Canadian Medical Association Journal in May 2004  Found an overall incidence rate of adverse.
Department of Human Services Promoting patient care through effective patient flow System wide implementation January – July 2005.
Improving the quality of medical and surgical care 1 Subarachnoid Haemorrhage.
WORLA Background & Aim W Harrison, 1 M Temple, 1 Victoria McClure, 1 S Harris, 1 A Tomkinson 1. Surgical Instrument Surveillance Programme (SISP), Temple.
The Importance of Patient Safety with Single-use Instruments - A Collaborative Surveillance Approach in Wales W. Harrison, A. Tomkinson, V. McClure*, S.
Management of Adults with Diabetes undergoing Surgery and Elective Procedures UHL Guideline – April 2013 The aim of the guideline is to improve standards.
A pilot assessment of the impact and resource implications of a 48-hour ward-based stewardship team review on antibiotic use in a tertiary centre Nicola.
Preventing Surgical Complications Prevent Harm from High Alert Medication- Anticoagulants in Primary Care Insert Date here Presenter:
Welcome to SURF 09 Involving Patients and the Public in HCAI Research.
Commissioner Feedback for SLAM CQC Inspection in September 2015 Engagement with Member Practices 1.
The Role of Thromboprophylaxis in Elective Spinal Surgery The Role of Thromboprophylaxis in Elective Spinal Surgery VA Elwell, N Koo Ng, D Horner & D Peterson.
Health Technologies Adoption Programme Stephen Hodges – Technology Implementation Manager.
The Health Roundtable Early detection of patient deteriopration Presenter: (delegate name) Innovation Poster Session HRT1215 – Innovation Awards Sydney.
Aligning professional and systems regulation: Can the whole be greater than the sum of its parts? Jon Billings Director of Strategy, Nursing and Midwifery.
‘WHO is kidding WHO’ Prospective Re-Audit of the implementation Pre-briefing and the WHO Surgical Safety Checklist at FPH August 2011 Department of Surgery.
Security Monitoring Model and Network for Regional Supply Chain with a particular focus on food security Kevin Lu P.R. China 33rd APEC Transportation Working.
Pursuing High Value Healthcare Optimizing Laboratory Testing Webinar #6 July 16,
Impact of: a specialist wound clinic on patients who develop complex wounds post cardiac surgery Presented by: Penny Gowland ANP Pascaline Njoki Thanks.
Department of Health The Australian Charter of Healthcare Rights in Victoria Your role in realising the Australian Charter of Healthcare Rights in Victoria.
The National Emergency Laparotomy Audit Dave Murray National Clinical Lead
Documentation Requirements for Hospital Accreditation -By Global Manager Group.
Background The United Kingdom Department of Health introduced single-use instruments (SUI) for tonsil and adenoid surgery in January 2001, based on the.
Care Quality Commission (CQC) Registration. Background The Care Quality Commission (CQC) is the health and social care regulator for England. From 1 April.
Audit of Day Case Tonsillectomy Aintree University Hospital, Liverpool M Baghat 1, S Knott 2, G Bessant 2, EZ Osman 2. 1:Faculty of Medicine, Alexandria.
MRSA on Ward 29 University Hospital Aintree (UHA) April 2006-August 2010 Zoe Greenwood February 2011.
Neuraxial Connector Surveillance Training
An Audit to Determine if Prescribers are Reviewing Antimicrobial Prescriptions Hours After Initiation. Natalie Holman, Emma Cramp, Joy Baruah Hinchingbrooke.
Genetic Technologist Registration and the AHCS
Title of the Change Project
Title of the Change Project
Title of the Change Project
Title of the Change Project
ASK MBSAQIP Agenda ASK MBSAQIP November 10, 2016 Time (CST)
Preventing HCAI’s through an education programme for nurses
Title of the Change Project
National audit of paediatric IBD service provision
ITI Portfolio Plan Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Current Date Visibility of ITI Projects ITI Projects.
Controlling Measuring Quality of Patient Care
Ward Stock Management Guide
An introduction to the Clinical Audit Phase
Preventing VTE in hospitalised patients
Principal recommendations
2019 Safety Group 1 – 5 Year Program Timeline Guide
Consultant Clinical Biochemist
Data source: Irish Pneumococcal Reference Laboratory
Emergency Laparotomy Cymru
About the national data opt-out
Is Primary Care Safe? HAPIA Conference 2014 Peter Walsh
Presentation transcript:

THE SINGLE-USE INSTRUMENT SURVEILLANCE PROGRAMME (SISP) AS A MODEL SYSTEM FOR THE INTRODUCTION OF DISPOSABLE INSTRUMENTATION AND NEW SURGICAL PROCEDURES Victoria McClure*, Alun Tomkinson, Mark Temple, Wendy Harrison (*corresponding author) The Single-use Instrument Surveillance Programme, NPHS, Abton House, Cardiff, CF14 3QX. In 2000, The Spongiform Enchephalopathy Advisory Committee (SEAC) identified a theoretical risk of transmission of variant Creutzfeldt- Jakob Disease (vCJD) from instruments used for surgical procedures 1. vCJD is a disease due to the same infectious agent as BSE, a fatal disease with a long incubation period, associated with the presence of pathologic prions. These abnormal proteins cannot be removed from surgical instruments by standard sterilisation methods raising concerns for transmission from patient to patient 2, In January 2001, single-use tonsillectomy instruments were introduced by the Department of Health due to high risks to patients (children and young adults) but withdrawn again shortly afterwards in England due to instrument safety concerns. Advice from SEAC regarding vCJD remained unchanged 3. The Welsh Assembly Government elected to remain with single-use instruments but launched an independent investigation. Work was also in collaboration with Welsh ENT surgeons via the Welsh Otorhinolaryngology Association (WORLA), the National Public Health Service for Wales (NPHS), The Surgical Materials Testing Laboratory (SMTL) and Welsh Health Supplies. In summary, the mechanism to deliver safe surgery in Wales, free of risk from vCJD, resulted in the establishment of the Single-use Instrument Surveillance Programme (SISP) in BACKGROUND To set up a specific surveillance programme in Wales to determine if surgery with single-use instruments could be as safe as with their equivalent reusable instruments. To demonstrate with successful implementation of this surveillance system that evidence-based reassurance of safe practice could be provided to the public and healthcare professionals. OBJECTIVES Estimating the postoperative haemorrhage rate complications (serious bleed rates) associated with adenotonsillectomy procedures. To monitor the performance of the single-use instruments themselves in order to provide early warning and investigation of the problems. To critically evaluate the system by external and internal auditing to ensure capture of all required data. AIMS OF THE PROGRAMME 1.Department of Health (2001) Risk assessment for transmission of vCJD via surgical instruments: a modelling approach and numerical scenarios. CJD publications London. Available from: htttp:// [Accessed 1 December 2005] 2.Tomkinson, A., Harrison, W. and Temple, M. (2005) The protection of patients in Wales from vCJD and a guarantee of single-use instrument safety. A success in collaboration. National Leadership and Innovation Agency for Healthcare conference. Cardiff. 3.Tomkinson, A., Harrison, W., De Martin, S. Backhouse, S. and Temple, M. (2005) The surveillance of single-use instruments in tonsil and adenoid surgery – postoperative haemorrhage and operative technique. Clinical Otolaryngology and Allied Sciences. In press. 4.Tomkinson, A., Phillips, P. Scott, J. B. et al. (2005) A laboratory and clinical evaluation of single-use instruments for tonsil and adenoid surgery. Clinical Otolaryngology and Allied Sciences 30 (2), REFERENCES In Wales, postoperative haemorrhage rates with single-use tonsillectomy instruments are similar to reusable instruments if appropriately specified and monitored in use. The SISP has adopted a unique surveillance allowing problematic instruments to be detected quickly and efficiently without compromising patient safety. Patients undergoing tonsil surgery have continued to be protected from the theoretical risk of vCJD transmission during surgery. The high standard of care and safety has been, and continues to be achieved mainly through the continued cooperation of ENT surgical teams in Wales with support from NPHS and The Welsh Assembly Government. Surgeons in Wales agree that the system must be in place if they are to continue using single-use instruments in Wales. This surveillance system is equipped for introduction of further surgical instruments and procedures, an excellent example to be followed by the rest of the UK. LESSONS LEARNT: This surveillance demonstrates that clinician-led systems are essential in order to achieve valuable and quality data, with emphasis on clinician ownership of data. CONCLUSIONS The authors would like to thank all members of the Welsh Otorhinolaryngology Association and all surgeons for their continued participation in this surveillance Acknowledgements Figure 1. Schematic diagram showing the surveillance system implemented SISP SISP (1) Questionnaire Distribution (2) Questionnaire completion THEATRE OR WARD OPERATION AND INSTRUMENT FORMS (4) Questionnaires scanned Data file produced (5) Import into All-Wales database ( 7) All Wales reports Import into hospital database by data transfer co-ordinator Production of local reports Surgical teams (3) Questionnaires returned via post by local surveillance coordinator (6) Data returned via post or HOSPITAL WAG COMPLICATION FORMS Initial complications (before patient discharged from hospital) Readmission complications (On readmission of patient to hospital) All hospital surgical teams (NHS and private) carrying out adenotonsillectomy surgery in Wales have participated in surveillance since A detailed supplier and laboratory audit was conducted to provide a single supplier of single-use instruments 4. Modifications to instrument design were established through working with Welsh ENT surgeons, leading to a set of specifically designed single-use steel instruments. A paper-based surveillance was set-up utilising questionnaires for data capture. Number of procedures, related post operative complication(s) and performance of the instruments are monitored. In addition, information on patient and surgeon characteristics, other operative / postoperative details and method of tonsillectomy chosen by the surgeons are collected. SISP is alone, however, in including a detailed assessment of each instrument in use by the surgeon at the time of surgery. All complications associated with the procedure are recorded (up to 28 days after the initial procedure). Initial complications (e.g. bleeds, pain occurring before the patient is discharged from hospital) and readmission complications (e.g. bleeds, pain occurring after discharge of the patient, requiring a readmission to hospital). Complications both requiring and not requiring a return to theatre are recorded. METHODS RESULTS Currently 13,209 procedures in total are present within the all Wales tonsils database. The number of procedures broken down per year are – 2,158, 5,126, 3,934 and 1811 for 2003, 2004, 2005 and until end of August 2006, respectively. Almost 9,000 are tonsillectomy and 3,000 adenotonsillectomy procedures. Table 1. Serious bleed rate = postoperative haemorrhage repair. It denotes those bleeds that require a return to theatre, either after an initial complication or on readmission to hospital. The serious bleed rate for 2003 to 2006 has remained lower than with reusable instruments (1.4%). Figure 2. Minor instruments denote those that are problematic but can be continued for use. Major problems, those that must be replaced immediately. Minor problems and major problems have each decreased 4-fold (2006 compared with 2003). Figure 3. Example of how the surveillance identifies problematic instruments in Wales. In 2003, the gag and blade were identified, and reported to SMTL. Modification of the instrument specification rectified this problem immediately. The diathermy has proved most problematic overall but has undergone less scrutiny (different supply company). Evaluation of the system – External and internal validation was conducted independently using the Patient Episode Database for Wales. The surveillance was above 95% efficient at recording the desired surgical procedure. 0.0% 5.0% 10.0% 15.0% 20.0% 25.0% 30.0% 35.0% 40.0% 45.0% 50.0% Feb- 03 Mar- 03 Apr- 03 May- 03 Jun- 03 Jul- 03 Aug- 03 Sep- 03 Oct- 03 Nov- 03 Dec- 03 Jan- 04 Feb- 04 Mar- 04 Date of Procedure % instrument problems from total no. used Gag & Blade Draffin rods Yankauer Eves Snare Lucs Den. Browne Birkett Gwynne Evans Negus Knot pusher Currette Diathermy Figure 3. Number of reported instrument problems by month by instrument usage (first year of the surveillance) SMTL WORLA SISP