WacorTec. Co., Ltd.. CONTENTS What is SCIS?A)PRINCIPLEB)SILVER & COPPER IONC)SAFETYD)ADVANTAGECOMPOSITION & SPECIFICATION OF SISCIRCUIT DIAGRAM OF SCISINSTALLATIONOPERATIONMAINTENANCECAUTION.

Slides:



Advertisements
Similar presentations
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Advertisements

CHAPTER 45 Engine Lubrication.
Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Daikin Altherma™ Troubling Shooting
AIRVITA CO.,LTD AIRVITA Antibacterial action MACHARISM AIRVITA AICI fusion Technology : When atomic ion reacts ① + ② + ③ Optimal separation.
Refrigerators.
AC-SSC-1 Installation and operation manual
Lockout & Tag Presented by Name Title Date. Course Outline Lock-out definitions Legal responsibilities Lock-out procedure Frequent mistakes Removing a.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Publisher The Goodheart-Willcox Co., Inc. Tinley Park, Illinois.
Installation. Indoor Unit Installation Typical Installation.
2G BBULBE PASS Instructions-4 Replacement of bubble generator.
Oxygen Concentrators.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Power-Fill Operation Demonstration Power-Fill Operation Demonstration (See Installation and Operation Manual for detailed instructions)
Suction Pumps.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Marubot Football League Service Manual.
PEUGEOT 206 INSTALLATION 99’— 05’ TU5JP4
Unit 205: Cold water systems
2013 Microwave Service Training All models. Samsung HA Warranty ALL Warranties are subject to change, always verify. 1 Year Parts & Labor Base Warranty,
California Friendly ® Landscape Training Irrigation System Troubleshooting The Metropolitan Water District of Southern California and the Family of Southern.
Lockout/Tagout Authorized Employee. What Is Hazardous Energy? –Often invisible –Can be hydraulic or mechanical –Live or stored –Moving machine or equipment.
Electrical Power Systems
Installation. Indoor Unit Installation Typical Installation.
Electrical Fundamentals
Charging System Service
Step 1 Park vehicle on a level surface then engage the parking brake and turn off engine. If you cannot comfortably get under the car, raise the front.
Chapter 19 Charging Systems.
EGD ELECTRICAL ELECTRICAL SYMBOLS.
CIRCUIT TYPES PHYSICS UNIT E. CIRCUITS Need a source of energy, a pathway for electrons, and something that uses energy. Ex) Sources: Battery, 120 V plug,
By Carlin Bright. Electricity The flow of electrons in a conductor.
7.
1 AMS 2000 Digital Water Ionizer AMS 2000 Digital Water Ionizer ALKAMEDI CO., LTD.
Installation. Indoor Unit Installation Typical Installation.
Settings & Adjustments. Settings & Adjustments.
Circuits and Electronics. Circuits A circuit is a closed path through which a continuous charge can flow. A circuit is a closed path through which a continuous.
ELECTRONICS WHAT DOES ‘ELECTRONICS’ MEAN TO YOU ?.
Basic Electrical Safety
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
2G BBULBE PASS Instructions-5 Replacement of Heater.
Lab Safety MYCAERT INC.. What is Safety? Safety is preventing injury and loss. Injury and loss may be inflicted on people or their property.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Battery Testing and Maintenance.
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
Principles of Electricity Background to electricity, circuits, and how to calculate.
SAMI MAKERSPACE MAKE: AN ELECTRONICS WORKSHOP. ELECTRICITY BASICS.
Electrical Safety, Subpart K
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
2 SISCON TECHNOLOGIST PVT.LTD ISO 9001:2000 CERTIFIED COMPANY SISCON is a leading group of Electronics Company dealing with automation product. This company.
UTH-65A VER. CAUTIONS ! PLEASE USE THE OUTLET PREPARED BY A QUALIFIED SERVICEMAN AND MUST CONFIRM IT BEFORE APPLY[SING AN ELECTRIC CURRENT.
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
Piston Engine Propulsion Ignition. Ignition in a piston engine requires: Spark plugs Magneto Condensers Distributor Contact breakers electronic systems.
Quick Start Guide for Flex Flow Pump
HV Battery Assembly.
Hemodialysis Lecture 3.
EnTrans Technology Co., Ltd.
"This document can not be used without Samsung's authorization"
Chapter 31 Battery Systems.
Electric Circuits Chapter 22 Section 3.
Fuel Supply System Service
Unit 2.4 Electric Circuits
Safety Stuff.
The Safe Use of Electricity
How to Perform Preventive Maintenance of the Personal Computer
Safety Meeting Topics Standby Generator Safety
FIGURE 18–1 A visual inspection on this battery shows the electrolyte level was below the plates in all cells.
Chapter 7: Classroom and shop manuals
Presentation transcript:

WacorTec. Co., Ltd.

CONTENTS What is SCIS?A)PRINCIPLEB)SILVER & COPPER IONC)SAFETYD)ADVANTAGECOMPOSITION & SPECIFICATION OF SISCIRCUIT DIAGRAM OF SCISINSTALLATIONOPERATIONMAINTENANCECAUTION & NOTE

WacorTec. Co., Ltd. WHAT IS SCIS? A)Principle Generated Silver & Copper ion by Electrolysis- "by flowing DC current to the silver, copper and titanium panels which are attached to STS housing" sterilizes water which gets though this STS housing over the water flow switch. B)Silver Ion Natural components of Silver have antibiotic and the sterilizing power and generated ion-colloidal Solution by Electrolysis destroys a single-celled animal-bacteria, virus, various kind of germs by changing proteins of them and ruining their cells however no harmful to multicellular organism or human body as well no toxicity and immunity phenomenon. Small amount of Silver ion can get the greatest effect of sterilization by 99.99% and is quite effective for 640 kinds of bacteria. Copper Ion It has a greatest effect on sterilization and extermination for Algae. C)Safety WHO regulates recommendation about silver only. In Law Of Safe Water of EPA in USA, any regulations about silver are not made in first type drinking water standard which has the legal binding power. Maxim allowed value regulated in second type drinking water standard which has not any legal binding power is 0.1ppm. This value is a recommended value for health about long or short term safety standard. Also in inspection about carcinogenicity and noxiousness, one which has no evidence or insufficient evidence is classified as D&E group, and is rated as very safe. By use of Pure Silver(99.99%) & Copper Electrode(99.9%), the generated ~50ppb Silver Ion & ~350ppb Copper Ion are less than the standard of EPA (100ppb of Silver and 1000ppb of copper consistency). SCIS is designed safely much more than TDI (Tolerable Daily Intake) of EPA.

WacorTec. Co., Ltd. WHAT IS SCIS? D)Advantage Chlorine, O-zone and Ultraviolet use for sterilizing swimming pools cause secondary pollution and side effects of hair decolorizing, skin disease, secondary pollution, bad taste and odor. Those conventional sterilization substances couldn’t be effective for the sterilization of Virus and Legionella. As those substances are used continuously, it causes the increase of expenses by tolerance of germs. SCIS is new-safe-cost save effective with high sterilizing power. Specially easy maintenance with lower maintenance coat as an economical sterilizer. E)Applications 1) Cooling Tower 2) Swimming Pool 3) Sauna, Bath Room 4) Spa 5) Pond, Fountain System

WacorTec. Co., Ltd. COMPOSITION & SPECIFICATION OF SCIS

WacorTec. Co., Ltd. COMPOSITION & SPECIFICATION OF SCIS SPEC Control Box Main power Free voltage : AC 100~240V (50/60Hz) SMPS(2.2A) Input : AC 100~240V, Out put : DC24V Constant current controller Input : DC24V, Out Put : 200mA & 1000mA Panel Meter(Volt) In put : DC24V Voltage control lever On-OFF switch 6A 250V Main power Lamp 6V (LED) Operating Lamp 24V (LED) Housing BODY STS MC NYLON Electrode(pole) Silver Panel(99.99%) : 1.5T X 1EA Copper Panel(99.97%) : 1.5T X 3EA Titanium panel : 1.5T X 5EA Flow Switch Micro Switch Type Flow sensor

WacorTec. Co., Ltd. Operation method Constant voltage & Constant current In & Out pipe size 15A~40A Silver & Copper Ion concentration Silver Ion : ~50ppb (in case of 1.5V setting) - Recommendatory value Copper Ion : ~350ppb (In case of 8.5V setting) - Recommendatory value The water condition of a swimming pool (water temperature, electrolysis / etc) shall be checked and tested in advance to get the right value of Silver Ion conc. Durability 9,000hours (considering the operation of 8 hours per a day, about 3~4 years available) * Depends on the condition of water, durability and generation of Silver Ion will be different. SIZE( W X L X H / mm) Weight(kg) Control box 225 X 150 X STS Housing 160 x Flow Switch 65 x 80 x Packing 400 x 300 x * Size & Weight COMPOSITION & SPECIFICATION OF SCIS

WacorTec. Co., Ltd. CIRCUIT DIAGRAM

WacorTec. Co., Ltd. INSTALLATION Ball valve STS HousingFlow switch By using "BY PASS" PIPE as the above drawing, connect our STS Housing,FLOW SWITCH, and each "ball valve“ ※ CAUTIONS 1.Flow switch and STS housing has to be installed in front of pump not to damage by high water pressure caused by water hammer. 2.‘Pressure reducing valve' has to be installed before flow switch to prevent flow switch and STS housing from damage caused by such as high water pressure and water hammer.

WacorTec. Co., Ltd. OPERATION Voltage control lever Main power lamp Operating lamp STS housing connector Flow switch connector Power code Digital Panel Voltage meter Main power switchCircuit Protector switch ※ CAUTIONS Control box should not be connected other electric devices. Because it has function to control minute current and if you use control box with other electric devices, it may not work properly.

WacorTec. Co., Ltd. OPERATION 1. After installation of SCIS and Flow switch through BY PASS, they(SCIS and Flow switch) shall be connected to the Control Box as the above drawing, 2. Then, power plug shall be connected to the Control box as the drawing, 3. Turn on the Main power switch then Main power lamp is on 4. Open the ball valve, the sensor of the flow switch let an electric current flow to the each pole then, silver & copper ion are generated(at this moment, Operating lamp can be on) 5. The Digital Panel meter and if necessary, control the voltage value by the Voltage controller. ( Silver Ion : 1.5V / Copper Ion : 8.5V ) 6. After finishing operation, the flow switch senses no water flow and cuts off electric current to stop emitting of silver & copper ion(Operation lamp can be off) 7. As it's not used for a long time, turn off the main switch and plug out of the outlet

WacorTec. Co., Ltd. MAINTENANCE Disassemble flow cell very 3 months and clean or remove any scale from the each pole for smooth operation and long life. 1) Turn off the power switch and disconnect the power plug 2) Disconnect STS housing from the control box 3) Undo the 5 rench balts which hold the cover 4) Lift the top cover assembly from the STS body for the separation 5) Silver panels, Copper panels and Titanium panels shall be cleaned with soft brush and remove any scale from panels (be careful not to let any water flow to the electrode terminal of inside top cover) 6) Assemble them again after cleaning

WacorTec. Co., Ltd. MAINTENANCE Management in case of malfunction CauseManagement In case of Power shutting off Check whether Power cord is connected with Wall out or Control Box. Check whether Circuit switch is off. In case of non operating even turning on main power Check whether Flow switch of Control box is connected with STS housing of Control box. Check whether the speed of a running fluid is smooth (Perceivable Flow switch : 3 bar) Open Upper cover of Flow Switch and check Micro- Switch In case of non - lighting of LEDChange the standardized and correct LED LAMP In case of the connection part leakage of STS housing cover Assemble after checking whether Gasket is destroyed by disassembly & assembly - Connect after checking IN/OUT directions once connecting pipes with Flow Switch & STS housing - Assemble after checking Marked parts that has Assembly directions once assembling or disassembling STS housing & Electrode (Pay attention that water does not flow into the connection part once assembly or disassembly) - Connect DC or Electrode part to the correct connection part because they have their own polarized positive or negative electrode.

WacorTec. Co., Ltd. CAUTION & NOTE CAUTIONS Following cautions about safety are to prevent unexpected harms beforehand. Please use this facility carefully according to this guide. Surely pay attention in Electric Shock wherever Electricity can flow Use the standardized & correct parts once need to replace parts Un-plug once need to reinforce, assemble, disassemble or replace parts Recover the primary wiring to avoid Electric Shock, troubles, and fire after repair or reinforcement Check whether Electric Power and Piping are connected correctly before operation Check all sections where leakage can occur at all times Clean hands after maintenance or reinforcement Implement after being familiar with Manual before installation, operation, maintenance or reinforcement Do not assemble or remodel products excepting engineer Pay attention not to damage or to fall drop products once movement or installation NOTE