Non-destructive testing using magneto-resistive sensors David P. Pappas Quantum Devices Group National Institute of Standards and Technology Boulder, CO,

Slides:



Advertisements
Similar presentations
Seminarul National de Nanostiinta si Nanotehnologie
Advertisements

Microwave near-field scanning microscope Abstract We present the development of a novel near-field scanning microwave microscope based on a dielectric.
Parameters and Trade-offs
On-chip inductance and coupling Zeynep Dilli, Neil Goldsman Thanks to Todd Firestone and John Rodgers for providing the laboratory equipment and expertise.
Nuclear Magnetic Resonance
SEM Magnification Calibration. Magnification Errors Proper calibration of the SEM scans (magnification) is primary to metrology. SEM Magnification requires.
The planar Hall effect: sensor and memory applications Lior Klein Department of Physics, Bar-Ilan University The Itinerant Magnetism Laboratory – Department.
Spectrum analyser basics Spectrum analyser basics 1.
M. Palm, CERN1 Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA.
Faraday’s Law  produces an induced current Lenz’s Law: Induced current is in a direction so as to produce a B opposing the change in magnetic flux, 
Ultrafast Manipulation of the Magnetization J. Stöhr Sara Gamble and H. C. Siegmann, SLAC, Stanford A. Kashuba Bogolyubov Institute for Theoretical Physics,
lecture 5, Sampling and the Nyquist Condition Sampling Outline  FT of comb function  Sampling Nyquist Condition  sinc interpolation Truncation.
Magnetic sensors and logic gates Ling Zhou EE698A.
Self-Induction Transducers ~ AC Supply v ref Inductance Measuring Circuit x (Measurand) Ferromagnetic Target Object Coil is activated by the supply and.
1 Research Objectives Develop non-contact, non-destructive, low cost, fast, accurate, high resolution and automated system for evaluating quality of solder.
Advanced NDE Technologies for Quality Control November 9 th, 2012 Dr. Jeong Na Technology Leader NDE Group 1250 Arthur E. Adams Drive Columbus, OH
Magnetic Data Storage. 5 nm Optimum Hard Disk Reading Head.
Chapter 5 Lecture 10 Spring Nonlinear Elements 1. A nonlinear resistance 2. A nonlinear reactance 3. A time varying element in you circuit or system.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
Electricity, Electronics And Ham Radio “Kopertroniks” By Nick Guydosh 4/12/07.
Chapter 6 Photodetectors.
4/11/2006BAE Application of photodiodes A brief overview.
1 Unit 4 Selected Topics. 2 Spintronic devices Hard disk drivesHard disk drives –GMR –Spin valve MRAMMRAM –Pseudo-spin valve –Magnetic tunnel junction.
3/26/2003BAE of 10 Application of photodiodes A brief overview.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
1 David P. Pappas National Institute of Standards and Technology Boulder, CO CNRS Thematic School High Sensitivity Magnetometers Sensors & Applications.
Spintronics Tomas Jungwirth University of Nottingham Institute of Physics ASCR, Prague.
The International Workshop on THIN FILMS APPLIED TO SUPERCONDUCTING RF AND NEW IDEAS FOR PUSHING THE LIMITS OF RF SUPERCONDUCTIVITY M. Valentino, Padova-Italy,
Sally Seidel 1 3D Sensor Studies at New Mexico Sally Seidel for Martin Hoeferkamp, Igor Gorelov, Elena Vataga, and Jessica Metcalfe University of New Mexico.
1 David P. Pappas Fabio da Silva Sean Halloran Alexey Nazarov NIST, Boulder, CO Ken Marr, James Ryan FBI Academy, Quantico, VA Magnetic Forensics The Lost.
Magnetoresistive Random Access Memory (MRAM)
Development of Airborne Potassium Magnetometer Dr. Ivan Hrvoic, Ph.D., P.Eng. President, GEM Advanced Magnetometers Exploration 2007 & KEGS.
Creative Research Initiatives Seoul National University Center for Near-field Atom-Photon Technology - Near Field Scanning Optical Microscopy - Electrostatic.
Quantum Confinement in Nanostructures Confined in: 1 Direction: Quantum well (thin film) Two-dimensional electrons 2 Directions: Quantum wire One-dimensional.
Figure 14.1: Following planar processing of the recording wafer, the lapping process dices the wafer into rows and then individual sliders As a result,
Spin Valves: - larger MR values then the AMR-based devices - exchange energy should be large (> 0.2 erg/cm -2 ) - blocking temperature > 300C - effective.
1 High Sensitivity Magnetic Field Sensor Technology David P. Pappas National Institute of Standards & Technology Boulder, CO.
Monday, January 31, 2011 A few more instructive slides related to GMR and GMR sensors.
Introduction to Spintronics
Gravitational Experiment Below 1 Millimeter and Search for Compact Extra Dimensions Josh Long, Allison Churnside, John C. Price Department of Physics,
Optical Receivers Theory and Operation
Ultra-low Field Nuclear Magnetic Resonance Measurements with SQUIDs
Digital to Analog Converter (DAC)
UCLA IEEE NATCAR 2004 SUMMER CLASS Magnetic Sensors & Power Regulation.
Submitted To: Presented By : Dr R S Meena Shailendra Kumar Singh Mr Pankaj Shukla C.R. No : 07/126 Final B. Tech. (ECE) University College Of Engineering,
1 Sensores Magnéticos José Augusto EPUSP The Types of Magnetic Sensors Reed Switches Variable Reluctance Flux-gate Magnetometers Magneto-Inductor.
Soumen Kar 1,2, Xiao-Fen Li 1, Venkat Selvamanickam 1, V. V. Rao 2 1 Department of Mechanical Engineering and Texas Center for Superconductivity University.
Real time shimming (RTS) for compensation of respiratory induced field changes P van Gelderen, JA de Zwart, P Starewicz, RS Hinks, JH Duyn Introduction.
SPINTRONICS Submitted by: K Chinmay Kumar N/09/
전자파 연구실 1. Fundamentals. 전자파 연구실 1.1 Frequency and time Passive circuit elements is emphasized in high speed digital design : Wires, PCB, IC- package.
Metallurgha.ir1. Lecture 5 Advanced Topics II Signal, Noise and Bandwidth. Fundamental Limitations of force measurement metallurgha.ir2.
Application of photodiodes
Electronics & Communication Engineering
Magnetoresistive Random Access Memory (MRAM)
INDUCTION MOTOR PROTECTION FOR SINGLE PHASING, OVERVOLTAGE AND OVER TEMPERATURE Submitted by:
MRI Physics in a Nutshell Christian Schwarzbauer
Photodetectors.
Welcome.
Magnetic Data Storage and Nanotechnology
Inverse Square Sensitivity
Presented by: Bc. Roman Hollý
Volume 101, Issue 6, Pages (September 2011)
Transducers Measurement/Information Processing System or
Precision Beam Monitors for COSY Jülich
Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA M. Palm, CERN.
Optical Receivers 1. Photo Detectors
Noise I Abigail Firme.
Nuclear Magnetic Resonance
Data Acquisition Electronics Unit – Lecture 6
Presentation transcript:

Non-destructive testing using magneto-resistive sensors David P. Pappas Quantum Devices Group National Institute of Standards and Technology Boulder, CO, A. Nazarov, Fabio da SilvaNIST Ken Marr, Jim RyanFBI Audio Lab Erin Gormley, Jim CashNTSB Dave KrefftNSA

Objectives Develop state-of-the art magnetic imaging metrology for NIST –Forensics –Bio-magnetic tag detection –Component failure analysis –Non-destructive testing Probe components non-destructively to determine: –Power usage Defects Design flaws Unapproved process – Investigate low level signal monitoring Wafer level De-processed devices

Procedure Methods: –Map out magnetic field above device under test (DUT). Single, scanned magneto-resistive (MR) element. Array of elements (faster). –DUT Test artifacts – striplines, etc. Sample chips – processed, deprocessed & flip-chip –Invert the magnetic field to find current distribution. Metrics – Low frequency current resolution: Limited by noise floor of sensor - field falls off as 1/d from DUT. –Spatial resolution: Deconvolution requires close proximity to DUT, low noise. –Temporal resolution – High frequency Johnson & shot noise of resistors increases with bandwidth.

Magnetic imaging system  x-y-z translation stage  Stationary sample  Lock-in amplifier  Unshielded magnetic sensor – 1  m resolution –AMR, GMR sensor mounted on flexure –Self aligning - slides on back of Si wafer –Sensors readily available  Scalable, arrayable, fast

Magneto-resistive (MR) sensors AMR - Anisotropic MR –Single ferromagnetic film NiFe –2% change in resistance Spintronic: –GMR trilayer w/NM spacer 60%  R/R min Co/Cu/Co “Spin Valve” –TMR – Insulator spacer 500%  R/R min at R.T. CoFeB/MgO/CoFeB Hayakawa, APL (2006) I M FM NM FM * * * *

Large arrays of MR sensors NDE Imaging applications –256 element AMR linear array –Thermally balanced bridges –High speed magnetic tape imaging – forensics, archival applications Cassette Tape – forensic analysis 4 mm 45 mm erase head stop event write head stop event 4 mm V+ V- I- 16  m x 256 I+ BARC.

Magnetic field measurement of current MR element - Localized Current, I B-field IBIB x Z (up) y BZBZ Coordinate system

Magnetic field probe above meander line test structure 10  m meander line 5 mA current Spacing = 1000  m Sensor 100  m above sample 8 x 8 mm, B z –field image BZBZ 1 mm

Image magnetic field of test stripline sample Lockin Amplifier data acquisition +-10 mA in 15 kHz, 1 ms 10  m wide meander Cross section scan

Deconvolution of planar currents from magnetic fields Localized current in y direction Measure B z Height = z 0 z x z0z0 BzBz X 1/x x=+z 0 -z 0 Transform method Chatraphorn, et. al (2000):

Calculate currents from B z Calculated currents Measured magnetic field image of test stripline x y -dB/dy +dB/dy +dB/dx -dB/dx

Non-destructive VLSI current measurement Intel flip-chip RAM Wafer thinned Had been probed with FIB from back Short circuit induced in center Q – Could we locate short circuit?

Intel flip-chip RAM with short height = wafer thickness (~500  m) Measured magnetic field - B z Calculated currents x y -J y +J x -J x +J y

Spatial resolution “From what height can we resolve two currents that are flowing in the same direction?” gap Z z < g z >> g sensor B

Spatial resolution In principle, deconvolution is perfect   functions in,  functions out  Works for any current distribution  Multiple sources, gnd planes In real life:  Smaller signal for large z  Noise – electronic & mechanical z >> g

Test structures for spatial resolution Split meander line: I = 65 mA g = 200,100, 50,20,10, 5  m Z = 500 and 100  m current g (  m) z=100  m z=500  m Resolves g ~ z/10

7 mA pulse Expected signal from stripline I = 7 mA, d = 1  m Gain = 1000 Single sweep MR elements as real-time, non-contact probes  V = 1 mV Signal from stripline with z~0

High frequency operation of probes - f >100 kHz Sample & Average Intrinsic sensor response ~GHz Filtering slows response Random noise – can be averaged out:  Johnson -  Shot -  1/f -neglible- => noise 6  s pulse Average 1000 sweeps

Present & Future Applications Probes –Non-destructive, localized current mapping –Monitoring of individual current lines –Spatial, temporal resolution determined by probe height Sensitivity signal strength Sampling (real-time vs. averaging) Linear & two-dimensional arrays –Field mapping VLSI failure analysis Listen in on high frequency chip emissions –Localization, analysis –Want gold standards for chip emissions to compare

For non-localized, planar source w Current in plane z-sensor h Ground planes, power, … Width of trace greater than height, size of sensor w >> z 0 B x = constant over current ~ 0 outside B z = 0 over current ~1/x outside current BzBz B x BxBx x-sensor B field

Asymmetric stripline 50  m wide line with ground plane, 100 mA, 1 kHz 50  Field distribution – B z Deconvoluted current - I y Use artifact with both types of currents

Ideal geometry for magneto-resistive arrays Use either B X & B Z sensor arrays 2 – dimensional image Field distribution - B x Deconvoluted current -I y In-plane field  current measurements

Sensitivity of MR vs. SQUID Signal: Resistive noise : (50 ohm, Johnson) BzBz Small area 1 x.05  m Tiny flux Large area >20 x 20  m Big flux Roth, et. al Chatraphorn, et. al  Flux =  MR elements comparable to SQUIDS in flux measurement

Test structure with features Asymmetric meander line With holes in return plane B Z at z = 1 mm 2 mm hole 1 mm 0.5 mm I (a) (b)

Current distributions calculated for asymmetric stripline Feature resolution optimal for z ~ d/2