The Kennedy Chamber 1 Entire Presentation Copyright 2006 Jack Kennedy Metal Products & Buildings, Inc. All Rights Reserved A Life Support System For Underground.

Slides:



Advertisements
Similar presentations
Damage Control.
Advertisements

IN-PLACE PROTECTION. LEARNING OBJECTIVES Explain the objective of In Place Protection Identify the means of warning List the criteria in choosing room.
SKA-Pak Plus Mobile Air Cart Con-Space Link
Power Plant Engineering
Fired And Unfired Pressure Vessels
International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
Boiler Operation Procedures
Powerfuel UK Static suppression in plastic/fiberglass pipe systems Dirk Smith – Ionix Gas Technologies.
Compressed Gases Slide Show Notes
Using Gas Welding Equipment
East Carolina University Compressed Gas Safety Training Program
1 Levels of Organization Subatomic Particles – electrons, protons, neutrons Molecule – Atoms bound together Macromolecule – Molecules bound together Atom.
3.4.5 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Pumps, Strainers and Bypass Systems Knowing how to maintain.
SFFMA Training Objectives: –
Copyright  Progressive Business Publications Blue Ridge Safety Association Safety Presentations Compressed Gasses.
1926 Subpart J Establishes the requirements for welding and cutting in the construction industry Establishes requirements for equipment, fire protection,
1 UBC International Training Fund Presents. Tensioning.
1 DIESEL FUEL TOOL ON VEHICLE DIESEL FUEL SYSTEM SERVICE MODEL Rx HD 888 INSIDE FILTER.
Torch & Consumable Technology Copyright, 2002 Hypertherm, Inc. These materials cannot be reproduced in any form without the permission of Hypertherm, Inc.
Ventilation Systems As Control Measures. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit.
HOW TO LIGHT AND TURN OFF THE OXY-ACETYLENE TORCH
OXY-ACETYLENE TORCHES Protect your head and eyes by wearing proper welding goggles or face shields equipped with a minimum shade 5 lens. Protect your.
DO YOU UNDERSTAND MINE EMERGENCIES? ARE YOU PREPARED FOR A MINE EMERGENCY? MODULE 6: BREATHABLE AIR SAFE HAVENS/REFUGE CHAMBERS R. LARRY GRAYSON & RAJ.
11-1 Copyright  2010 McGraw-Hill Australia Pty Ltd PowerPoint slides to accompany Puffett, Hossack, Stone, Burn & Miles, Gasfitting 2e Chapter 11 OPERATION.
Terms and Definitions Base Metal: Metal to be welded Fusion Welding: process that joins metals by heating them to a melting point and allowing them to.
FIRE SAFETY TRAINING THE LOSS PREVENTION UNIT OF THE OFFICE OF RISK MANAGEMENT.
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
Hydraulics.
Metal Cutting Processes Flexible Manufacturing
Trapped Miners Now Have A Chance For Survival! Mine Escape Planning & Emergency Shelters Workshop National Academy of Sciences Washington, DC April 18,
Know You System Fire Extinguisher & Suppression Activation Training.
Skilled Trades 1201 Residential Plumbing.
Confined Spaces in Construction: Applicable Standards Stan Liang, CIH, CSP, CET KTA-Tator, Inc.
TRI MARTIANA.  A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants such as dust, fumes,
Hydronic Mechanical Controls
Mosaic Potash Operations Refuge Stations – Esterhazy & Colonsay February, 2006.
Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam at the desired temperature and pressure.
MINE RESCUE ACTIVITY BOOK – Section IV MSHA 2208 NOVEMBER 1981 JUNE 2005.
VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Iouri Ivaniouchenkov RAL Safety considerations at RAL July 9, RAL MICE Collaboration Meeting 1.
FILTRATION Presentation on FILTRATION. Introduction What is filtration? Why is filtration important? What are filter media? Can you name different types.
PERSONAL PROTECTIVE EQUIPMENT State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
FFII Module A Hillcrest Fire Department © 2001
PPE Use Standard (SSP-0011) Y Full Face Shield / Goggles Hood Clothing—Chemical Protection Gloves—Chemical Personal Fall Protection Respirator / Filter.
To be effective an extinguisher: Must be readily accessible In working order Suitable for the hazard Large enough to control the size fire Must be readily.
Presentation Dungrani rakesh v. Div : a Branch : mechenical Sem : 1 st.
Forging new generations of engineers. Basic Pneumatics.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only.
Refuge Alternative Update January 31, Refuge Alternative Rule Required by 2006 MINER Act and 2008 Appropriations Act for underground coal mines.
1. Purpose  It is the policy of the company to provide equipment necessary to prevent injury in the event of a chemical exposure. Types of hazards 
Mine Fresh Air Base.
Flashpoint of Kerosene by Tag Manual Closed Cup Tester NOTE: Sample should be chilled to at least 20°F below expected flashpoint. 1Place flash tester in.
Engine Performance BASIC MAINTENANCE AND LIGHT REPAIR.
5 th and 8 th Mr. Luper.  Keep the cylinders upright at all times  In storage  On carts  Keep cylinders secured  Mark cylinders when empty  Write.
Fire Fighter Safety SCBA CHANGE/REFILL
KIRBY MORGAN HELMET MODELS
Using Gas Welding Equipment
North Central Florida Local Emergency Planning Committee
Learning Objective 3 Define the ratings in a portable fire extinguisher rating system.
Super Flow 450 Regulator.
East Carolina University Compressed Gas Safety Training Program
Power Plant Engineering. Boilers Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam.
BASIC PNEUMATICS.
North Central Florida Local Emergency Planning Committee
Rajan Bhandari Senior Lecturer
Disaster Preparedness
Super Flow 455 Stainless Regulator
Presentation transcript:

The Kennedy Chamber 1 Entire Presentation Copyright 2006 Jack Kennedy Metal Products & Buildings, Inc. All Rights Reserved A Life Support System For Underground Mines This presentation shows products that have patents granted or pending, US or foreign.

The Kennedy Chamber2 Escape The Mine! Chambers Are Simply Better Barricade Materials

The Kennedy Chamber3 But If You Can’t Escape You Might Want a Chamber

The Kennedy Chamber4 Design Criteria 100 Hour Operation At Full Capacity Very Quick Initialization Purge Air To Quickly Ready Chamber (House Units) Onboard Oxygen Supply Without Chemicals, Heat Or Ignition Sources

The Kennedy Chamber5 Design Criteria (Con’t) Oxygen Rate Adjustable According To Occupancy CO2 Scrubbing Positive Pressure Operation No Power Required ‘Mine Tough’ Unit 5 Year Commission Life

The Kennedy Chamber6 Mine Tough The Chamber Is Designed To Be Used In An Underground Mine The Skid Design Allows Repeated Movement With A Minimum Of Unit Height A Special ‘Hardened’ Version Is Available As An Option

The Kennedy Chamber7

8 Life Support Capacity 100 Hours At Full Capacity 200 Hours At Half Capacity Capable Of Two Times Overload At Half Duration

The Kennedy Chamber9 ‘Instant’ Setup Time Most Of The Time All You Have To Do To Use The Chamber Is Enter It If It Is Contaminated, Purge Air Is Supplied To Blow Out The Chamber Oxygen Flow Is Started With The Turn Of A Knob CO2 Scrubbing Is Initialized In Minutes

The Kennedy Chamber10 Simple Operation No. 1 Purge Chamber (If Necessary) No. 2 Start Oxygen Flow No. 3 Deploy Scrubber Material

The Kennedy Chamber11 Deployment Instruction Placard

The Kennedy Chamber12 No. 1 Open The Purge Air Valve

The Kennedy Chamber13 Purge Air Muffler

The Kennedy Chamber14 No. 2 Start Oxygen Flow Oxygen Must Be Regulated According To The Number Of People In The Chamber Too Little Causes Hypoxia Excess Flow –-  Wastes Chamber Time  Causes Oxygen Toxicity  Creates A Fire Hazard

The Kennedy Chamber15 Oxygen Placard

The Kennedy Chamber16 Oxygen Flow Meter

The Kennedy Chamber17 No. 3 Start CO2 Scrubbing CO2 Control Is By Lithium Sheet No Power Is Required Very Long Periods (Hours) Between Sheet Changes

The Kennedy Chamber18 Scrubbing Media Timer Mechanical 24 Hour Timer With Bell

The Kennedy Chamber19 5 Year Commission Life Everything In The Chamber Is Designed For A 5 Year Life WITHOUT Maintenance Routine Inspection Only Requires –  Looking At The Outside For Damage  Checking The Air and Oxygen Gauges  Checking The Tamper Seal

The Kennedy Chamber20 Pressure Gauges Gauges Visible Without Entering Chamber Oxygen Gauge Visible From Both Directions

The Kennedy Chamber21 Recommissioning Factory Recommissioning Is Available At Their 5 Year Anniversary The Oxygen And Air Cylinders Must Be Removed And Hydrostatically Tested Provisions Replaced Damage Repaired

The Kennedy Chamber22 Three Unit Types -- House Folding House Skid

The Kennedy Chamber23 House Best Choice – Ready To Go – Very Cost Effective

The Kennedy Chamber24 Folding House Unit Allows Transportation Under Low Top Deployment Takes No More Height Than A Completely Deployed Unit Contains Everything A House Unit The Same Capacity Has Does Not Have An Airlock

The Kennedy Chamber25 Step 1

The Kennedy Chamber26 Step 2

The Kennedy Chamber27 Step 3

The Kennedy Chamber28 Step 4

The Kennedy Chamber29 House Unit Deployed

The Kennedy Chamber30 Skid Unit Suitable For Very Low Conditions Can Carry Barricade Materials Contains Everything A House Unit The Same Capacity Has

The Kennedy Chamber31 Design Details

The Kennedy Chamber32 Heavy Cylinder Containment ½” Plate ‘Armor’ Special Longitudinal Restraint

The Kennedy Chamber33 Energy Absorbing Design

The Kennedy Chamber34 Escape Windows

The Kennedy Chamber35 Permissible Telephone ‘Thru Hull’ Connectors

The Kennedy Chamber36 Chemical Toilet ‘Unlimited Capacity’ Gas Tight Valve

The Kennedy Chamber37 Provisions Food Water Reading Material Books Pencils Games 300 Hour Permissible Flashlights

The Kennedy Chamber38 Light, Bright, Unobstructed Interior

The Kennedy Chamber39 Gas Sampling Port

The Kennedy Chamber40 Positive Pressure Relief Valve

The Kennedy Chamber41 First Aid EMT Kit Plus –  Large and Small Air Splints  Backboard

The Kennedy Chamber42 Repair Materials Oversize SAR Acrylic Windows Duct Tape

The Kennedy Chamber43 Training DVD Training Materials Mobile Chamber