Kazi Md. Shahiduzzamna, EEE, NUB

Slides:



Advertisements
Similar presentations
Chapter 24 Three-Phase Systems.
Advertisements

EE 369 POWER SYSTEM ANALYSIS
Lecture Notes 4 Per Unit System
ENERGY CONVERSION ONE (Course 25741)
Today’s Topics 1- The per unit system 2-Transformer Voltage Regulation
Per Unit Representation Load Flow Analysis Power System Stability Power Factor Improvement Ashfaq Hussain.
Circulating Current – load switch open. Circulating Current load switch closed.
Announcements Be reading Chapter 3
Lecture No. 11 By. Sajid Hussain Qazi
Topic 1 : Magnetic Concept and Transformer
Lecture 8 Transmission Lines, Transformers, Per Unit Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
Chapter 7 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Transformer with open secondary.
Transformer with open secondary.
Elec467 Power Machines & Transformers
Example 1 A 9375 kVA, 13,800 kV, 60 Hz, two pole, Y-connected synchronous generator is delivering rated current at rated voltage and unity PF. Find the.
Lecture 28Electro Mechanical System1  Consider a circuit with a source, a load, & appropriate meters.  P and Q are positive, so the load absorbs both.
Alternating Current Circuits
TRANSFORMER mohd hafiz ismail hafizism, january 2007.
Single Phase Transformer
1.6 Real Single-Phase Transformer.
Passive Elements and Phasor Diagrams
1 1. Power and RMS Values. 2 Instantaneous power p(t) flowing into the box Circuit in a box, two wires +−+− Circuit in a box, three wires +−+− +−+− Any.
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems
Announcements For lectures 8 to 10 please be reading Chapter 3
Announcements Please read Chapter 3 H4 is 4.34, 4.41, 5.2, 5.7, 5.16
Power System Fundamentals EE-317 Lecture 3 06 October 2010.
Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 OHT 15.1 Alternating Voltages and Currents  Introduction  Voltage and Current.
Announcements Please read Chapter 3; start on Chapter 6
Chapter 13 Magnetically Coupled Circuits
Copyright © 2009 Pearson Education, Inc. Chapter 33 Inductance, Electromagnetic Oscillations, and AC Circuits Part II.
1 Department of Electrical & Communication Engineering CHAPTER 1 Per Unit Calculations 1.Power System Representation Power Component SymbolPower ComponentSymbol.
Modeling of Power Transformers A Static Device. Transformers The transformer enables us to utilize different voltage levels across the system for the.
RC Circuits Chapter 10 Thomas L. Floyd David M. Buchla DC/AC Fundamentals: A Systems Approach.
Unit 8 Phasors.
Announcements For lectures 9 and 10 please be reading Chapter 3
Chapter 2 Transformers Edit by Chi-Shan Yu Electric Machinery.
Single-phase series a.c. circuits. Purely resistive a.c. circuit In a purely resistive a.c. circuit, the current I R and applied voltage V R are in phase.
Lecture 03: AC RESPONSE ( REACTANCE N IMPEDANCE ).
BASIC ELECTRICAL TECHNOLOGY DET 211/3 Chapter 6: Single Phase Transformer (Continued)
AC POWER ANALYSIS. 2 Content Average Power Maximum Average Power Transfer Complex Power Power Factor Correction.
Instructor :Kashif Mehmood
Protection of Power Systems
Per-Unit System.
EEK260 -Electrical Machines
SMJE 2103 Electrical Power System
ELEN 3441 Fundamentals of Power Engineering Spring Instructor: Dr. Gleb V. Tcheslavski Contact: Office Hours:
GANDHINAGAR INSTITUTE OF TECHNOLOGY Electrical Power System
NEUTRAL CURRENT IS NOT ZERO
SMJE 2103 Electrical Power System 3- Ph Power Apparatus.
Parul Institute Of Technology Name Of Subject:-Electrical Machines Name Of Faculty:-(1) Suresh Sahoo (2) Yogendra Tiwari E&C 3 rd Sem. Prepaid By :- Sr.No.NameEnrolment.
Power System Protective Relaying-Part Two
Hao Zhu Dept. of Electrical & Computer Engineering University of Illinois, Urbana-Champaign ECE 498HZ: Power Distribution System Analysis.
Chapter 16 Inductive AC Circuits.
Lesson 10: Transformer Performance and Operation
ECE 476 POWER SYSTEM ANALYSIS
B4.2 Power System One-Line Diagrams
Subject :ELECTRICAL POWER SYSTEM - I( )
BASIC ELECTRICAL TECHNOLOGY DET 211/3
Module B3 More on Three Phase Analysis
Module B4 Per Unit Analysis
Per-Unit System.
ECE 3301 General Electrical Engineering
Energy Conversion and Transport George G. Karady & Keith Holbert
Electric Circuits Fundamentals
Exercise Session 3 Power systems.
The instantaneous power
Electrical Machines (EELE 3351)
Prepared by: Ismael K. Saeed
Presentation transcript:

Kazi Md. Shahiduzzamna, EEE, NUB Power System 1 EEE 3231 One line Diagram, Impedance and Reactance Diagram and Per unit concept Kazi Md. Shahiduzzamna, EEE, NUB

Outline of this chapter The One-line Diagram The Impedance and Reactance Diagram The per unit concept and its advantages Base selection

One line diagram Definition: Often any diagram is simplified by omitting the completed circuit through the neutral and by indicating the component parts by standard symbols rather than by their equivalent circuits. Such a simplified diagram of an electric system is called a one-line diagram.

Example of one line diagram: #1 Generator-20,000 kva, 6.6 kv, X" = 0.655 ohms #2 Generator-10,000 kva, 6.6 kv, X" = 1.31 ohms #3 Generator-30,000 kva, 3.81 kv, XI! = 0.1452 ohrns T l and T 2 -each transformer in each 3-phase bank-10,000 kva, 3.81-38.1 kv, X = 14.52 ohms referred to the high-tension side Reactance of the transmission line = 17.4 ohms Load A = 15,000 kw, 6.6 kv, pJ. = 0.9 lag Load B = 30,000 kw, 3.81 kv, pJ. = 0.9 lag

The Impedance and Reactance Diagrams Definition: When the components of the one line diagram is represented by there corresponding impedance and reactance is known as Impedance and Reactance Diagram of that one line diagram. Need for The Impedance and Reactance Diagrams: To calculate the performance of a system under load conditions To calculate the performance of a system upon the occurrence of a short circuit Point should be noted that The impedance diagram does not include the current-limiting impedances shown in the one-line diagram.

The Impedance and Reactance Diagram of the given example of one line diagram is shown below: Point should be noted As the magnetizing current of a transformer is usually insignificant compared to the full-load current, the shunt admittance is usually omitted in the equivalent circuit of the transformer. the inductive reactance of a system is much larger than its resistance. So resistance is omitted from the impedance diagram.

So the impedance diagram is reduce to the following figure where only reactance is existed, This figure is called reactance diagram of the system.

Per Unit Concept: The per-unit value of any quantity is defined as the ratio of the quantity to its base value expressed as a decimal. The ratio in per cent is 100 times the value in per unit. The per-unit method has an advantage over the per cent method because the product of two quantities expressed in per unit is expressed in per unit itself, but the product of two quantities expressed in per cent must be divided by 100 to obtain the result in per cent. Important points regarding Per unit Quantity: three-phase circuits are solved as a single line with a neutral return, the bases for quantities in the impedance diagram are kVA per phase and kV from line to neutral. For single-phase systems, or three-phase systems where the term current refers to line current, the term voltage refers to voltage to neutral, and the term kVA refers to kVA per phase. But Data are usually given as total three-phase kVA and line-to-line kV. So The base voltage to neutral is the base voltage from line to line divided by √3. And the per-unit value of the kVA per phase on the kVA-per-phase base is the per-unit value of the three-phase kVA on the three-phase kVA base divided by three .

Formulas related various Quantities: For phase base voltage and single phase base kVA. For line to line base voltage and total three phase base kVA.

to change from per-unit impedance on a given base to per- unit impedance on a new base, the following formula applies: The Advantages of Per-unit Computations: Manufacturers usually specify the impedance of a piece of apparatus in per cent or per unit on the base of the name-plate rating. The per-unit impedances of machines of the same type and widely different rating usually lie within a narrow range, although the ohmic values differ materially for machines of different ratings. The way in which transformers are connected in three-phase circuits does not affect the per-unit impedances of the equivalent circuit. Example related this topics are 6.10 and 6.11 from the book and 8.2 in the soft copy of the book.

Reference Book Elements of Power System Analysis by Willaim D. Stevenson, Jr.