BIOMATERIALS ENT 311/4 Lecture 4 Metallic Material Prepared by: Nur Farahiyah Binti Mohammad Date: 28 th July 2008

Slides:



Advertisements
Similar presentations
Tarnish and corrosion Dr. Waseem Bahjat Mushtaha Specialized in prosthodontics.
Advertisements

Electricity from Chemical Reactions
Corrosion.
Unit 11- Redox and Electrochemistry
Heat Treatment of metals
Titanium Alloy Titanium and its alloys have proven to be technically superior and cost-effective materials of construction for a wide variety of aerospace,
Casting Alloys, Solders, and Wrought Metal Alloys
MECHANICAL PROPERTIES
Copyright © 2011 by Saunders, an imprint of Elsevier Inc. Physical Properties of Dental Materials Chapter 3.
Electrolysis.
Ions and Ionic Compounds l OBJECTIVES: –Determine the number of valence electrons in an atom of a representative element.
Introduction to dental metallurgy
Fuel cells differ from batteries in that the former do not store chemical energy. Reactants must be constantly resupplied and products must be constantly.
Bone Fracture. Recall: Three types of Stress: Three types of Stress: Tension Tension Compression Compression Shear Shear.
CHAPTER 16: CORROSION AND DEGRADATION
Surface Technology Part 4 Corrosion
Stainless Steels Stainless steels are iron base alloys that contain a minimum of approximately 12% Cr, the amount needed to prevent the formation of rust.
Materials. Materials used as replacement parts in the skeletal system include: Silicone Ultra High Weight Polyethylene (UHMWPE) Super Alloy Cement – to.
B. AmsdenCHEE 340 BIOMATERIALS OBJECTIVES To introduce the different biomaterials used in biomedical engineering, provide some fundamental properties of.
Lesson 2. Galvanic Cells In the reaction between Zn and CuSO 4, the zinc is oxidized by copper (II) ions. Zn 0 (s) + Cu 2+ (aq) + SO 4 2-  Cu 0 (s) +
Corrosion & Associated Degradation
LECTURER6 Factors Affecting Mechanical Properties
Physical Science Applications in Agriculture Unit Physical Science Systems.
Metals Most elements are metals. 88 elements to the left of the stairstep line are metals or metal like elements.
Uniform or general corrosion is typified by the rusting of steel Uniform or general corrosion is typified by the rusting of steel.  Other examples.
CANKAYA UNIVERSITY OFFICE OF BASIC AND ELECTIVE COURSES -ENGLISH UNIT-
Types of corrosion Dr. Syed Hassan Javed.
5 Biomaterial Degradation CHAPTER
Chapter 9 Characteristics of Metallic Materials. Objectives Four major classifications – ferrous,non ferrous, high temperature super alloy, and refractories.
INTRODUCTION The ultimate goal of a manufacturing engineer is to produce steel/metal components with required geometrical shape and structurally optimized.
Alloys.
Corrosion is the unwanted oxidation of a metal.. Oxidation of all Metals in general is called corrosion Oxidation of All Metals is called Corrosion.
Unit V Lecturer11 LECTURE-I  Introduction  Some important definitions  Stress-strain relation for different engineering materials.
Shipwrecks, Corrosion and Conservation
The application can be categorized into followings: Hard Tissue Applications Soft Tissue Applications Most of living tissues i.e. bone, collagen, cartilage.
Some “short term” medical applications of degradable polymeric biomaterials.
Redox Reactions Year 11 Chemistry ~ Unit 2.
6/2/20161 CHAPTER 2 CORROSION PRINCIPLES Chapter Outlines 2.1 Oxidation and Reduction Reactions 2.2 Standard Electrode Half- Cell Potentials 2.3 Standard.
Polarization.
Chapter 26 – Electricity from Chemical Reactions.
Shipwrecks, Corrosion and Conservation Summary Slides PART 3 – Jack Dengate.
TARNISH & CORROSION By Head of Department Dr. Rashid Hassan Assistant Professor Science of Dental Materials Department DENTAL SECTION (W.M.D.C) ABBOTTABAD.
SURFACES BARRIORS & CLEANING
Categories of Biomaterials
Welding Inspection and Metallurgy
Section 14.2 Voltaic Cells p Voltaic cells Voltaic cells convert chemical energy to electrical energy. In redox reactions, oxidizing agents.
Forms of Corrosion: Uniform Pitting Crevice Corrosion or Concentration Cell Galvanic or Two-Metal Stress Corrosion Cracking Intergranular Dealloying Selective.
DR KAFEEL AHMED Cast iron Properties 1.Strength 2.Hardness 3.Brittleness 4.Stiffness Depends upon 1.Alloying elements 2.Annealing.
GENERAL CONSIDERATION IN DESIGN OF MACHINE ELEMENTS
ENT 487 ENVIRONMENTALLY ASSISTED CRACKING IN METALS
Metals. Metallic bond Metals are often described as positively charged nuclei in a sea of electrons. The outer electrons of the metal atom nuclei are.
Dental Restorations Dr Huda Yaser.
Corrosion process and control (TKK-2289)
Corrosion process and control (TKK-2289)
Nonferrous Metals & Alloys. Nonferrous Metals Ferrous Alloys – alloys contain iron Nonferrous Metals – metals do not contain iron such as Copper (Cu),
Engineering Chemistry CHM 406
Basic Corrosion Theory
Implant: مادة سنية / د . زينة ثاني اسنان موصل 12 / 4 / 2016
Senior Science Bionics
ENT 487 ENVIRONMENTALLY ASSISTED CRACKING IN METALS
Corrosion Objectives Corrosion process Environmental factors
Dr. Omar S.M.J.Ali PhD Orthodontic
Galvanic Series.
Chapter 2 - Electrochemistry and Basics of Corrosion
Corrosion & Associated Degradation
Electrochemistry Review
Electrolysis: driving chemical reactions by electricity
Chapter-6 : Biomaterials
Biomaterials Dr. Ahmed Moro.
Implant materials in orthopedic trauma David Eglin, Nicola Kildea
Presentation transcript:

BIOMATERIALS ENT 311/4 Lecture 4 Metallic Material Prepared by: Nur Farahiyah Binti Mohammad Date: 28 th July

2 Teaching Plan METALLIC BIOMATERIALS Review types of metallic biomaterials Define & describe the biomedical application of metallic biomaterial Evaluate effect of the physiological environment on metallic material DELIVERY MODE Lecture LEVEL OF COMPLEXITY Knowledge Repetition Evaluation COURSE OUTCOME COVERED Ability to describe the concept of biocompatibility & basic concepts of materials used in medical application Ability to select biomaterials that can be used for different medical applications and explain the criteria that will lead to a successful implants

3 1.0 Introduction Metals and its alloys widely used as biomaterial because: Strong material Ductile : Relatively easily formed into complex shape High modulus and yield point : make them suitable for bearing large load without leading to a large deformations and permanent dimensional change.

4 Metallic material usually used in Prostheses: serve to replace a portion of body such as joint, long bones and skull plates. Fixation devices: used to stabilize broken bones and other tissue while the normal healing proceed. E.g. bone plates, rods, intramedullary nails, screw and sutures. 1.0 Introduction

5 Metals commonly used in Biomedical Application MetalsApplications Cobalt-chromium alloysArtificial heart valves, dental prosthesis, orthopedic fixation plates, artificial joint components, vascular stents Gold and platinumDental fillings, electrodes for cochlear implants Silver-tin-copper alloysDental amalgams Stainless steelDental prosthesis, orthopedic fixation devices (such as plates and screw), vascular stents Titanium alloysArtificial heart valves, dental implants, artificial joint components, orthopedic screws, pacemaker cases, vascular stents Summary

6 Stainless steel Cobalt-chromium alloys Titanium alloys Gold and platinum Silver-tin-copper alloys 2.0 List of metals

7 3.0 Stainless Steels Predominant implant alloy. In 1926-The first stainless steel (18Cr- 8Ni) was utilized for implant fabrication, which is stronger and more resistant to corrosion than the vanadium steel. In 1943, type 302 stainless steel had been recommended to U.S Army and navy for bone fixation.

8 3.0 Stainless Steels (cont) Later 18-8sMo stainless steel or known as 316 stainless steel, which contains a small percentage of molybdenum to improve corrosion in chloride solution (salt water) was introduced. In the 1950s – 316L stainless steel was developed by reduction of maximum carbon content from 0.08% to 0.03% for better corrosion reduction especially to physiological saline in human body.

9 Chromium content of stainless steel should be at least 11% to enable them resist corrosion. Chromium oxide on the surface of steel provide excellent corrosion resistance. This table adapted from Biomaterials, Sujata V.Bhat 3.0 Stainless Steels (cont) 0.08

10 Most widely used for implant fabrication: Austenitic stainless steel 316 stainless steel 316L stainless steel 3.0 Stainless Steels (cont)

Stainless Steels (cont) Strengthens the alloyWeakens the alloys (low mechanical strength) Cold working ( material is exposed at low temperature relative to the melting point, This leads to an increase in the yield strength of the material and a subsequent decrease in ductility.yield strengthductility Annealing (material is exposed to high temperatures for long period in order to increase ductility and toughness of the material.

Stainless steel alloy application Stainless steel alloy application DevicesStainless steel type Orthopedic Fixation Devices: Jewitt Hip nails and plates Intramedullary pins Mandibular staple bone plates Schwartz clips (neurosurgery) Implant prostheses Cardiac pacemaker electrodes Heart valves Stent 316L L (new: nickel free stainless steel)

Stainless steel alloy application Jewitt Hip nails and plates

Stainless steel alloy application Intramedullary pin Mandibular staple bone plates Schwartz clips (neurosurgery) Cardiac pacemaker electrodes

Cobalt-Chromium Alloys The ASTM list four types of CoCr alloys which are recommended for surgical implant application: cast CoCrMo alloy (F75) Wrought CoCrWNi alloy (F90) Wrought CoNiCrMo alloy (F562) Wrought CONiCrMoWFe alloy (F563) At present only two are used extensively in implant fabrication, which are cast CoCrMo alloy and wrought CoNiCrMo alloy ASTM= The American Society for Testing and Materials

16 Molybdenum is added to produce finer grains = results in higher strengths. Chromium = enhance corrosion resistance. 4.0 Cobalt-Chromium Alloys (cont)

Cobalt-Chromium Alloys (cont) Advantages of CoNiCrMo Highly corrosion resistance to seawater (containing chloride ions) under stress. Has a superior fatigue and ultimate tensile strength than CoCrMo → suitable for application which require long service life such as stems of the hip joint prosthesis

18 Femoral component of hip joint prosthesis

Cobalt-Chromium Alloys (cont) This table adapted from Biomaterials, Sujata V.Bhat

Cobalt-Chromium Alloys (cont) Problems with CoCr alloys: Particulate Co is toxic to human osteoblast and inhibits synthesis of type I collagen. Advantages of CoCr alloys: Low wear Hard Tough High corrosion resistance Application : Artificial heart valves, dental prosthesis, orthopedic fixation plates, artificial joint components, vascular stents

Titanium alloys Titanium is a light metal. Density = g/cm 3 at 26 o C AlloysDensity (g/cm 3) Ti and its alloys 316 stainless steel CoCrMo CoNiCrMo NiTi

Titanium alloys (cont)

23 Ti6Al4V is widely used to manufacture implant. Has approximately the same fatigue strength (550MPa) with CoCr alloy. That’s why it has same application as CoCr alloy. However it more preferable because it has low density. 5.0 Titanium alloys (cont)

Titanium alloys (cont) Modulus elasticity of titanium and its alloy is about 110GPa except for the Ti13Nb13Zr.

Titanium alloys (cont) When compared by the specific strength (strength per density) the titanium alloys exceed any other implant material.

26 Advantages: Resistance to corrosion by the formation of solid oxide layer to a depth of 10nm. Under in vivo conditions the oxide (TiO 2 ) is the only stable reaction product. Limitation: Has poor sheer strength → less desirable for bone fixation devices e.g. bone screw and plates. Tends to gall when in sliding contact with itself or another metal. 5.0 Titanium alloys (cont)

27 However, micro motion at the cement- prosthesis and cement-bone are inevitable, consequently titanium oxide and titanium alloy particles are released into the extra cellular fluid and can cause toxicity or triggers giant cell response around the implant. 5.0 Titanium alloys (cont)

28 Biomedical application: Artificial heart valves, dental implants, artificial joint components, orthopedic screws (less desirable), pacemaker cases, vascular stents 5.0 Titanium alloys (cont)

Silver-tin-copper alloys (Amalgam) Amalgam is a commonly used dental filling. Dental filling is a dental restorative material used artificially to restore the function and morphology of missing tooth structure. The structural loss typically results from caries or external trauma.

30 Amalgam is an alloy made of liquid mercury and other solid metal particulate alloys made of silver, tin, copper, etc. Dental amalgam typically contain: 45 to 55% mercury 35 to 45% silver 15% tin 6.0 Silver-tin-copper alloys (Amalgam)

Silver-tin-copper alloys (Amalgam) Mechanical properties of dental amalgams AmalgamCompressive strength (MPa) Tensile strength (MPa) Lower Copper Admix Single composition

32 Advantages over other restorative material It is inexpensive relatively easy to use and manipulate during placement it remains soft for a short time so it can be packed to fill any irregular volume, and then forms a hard compound. Amalgam possesses greater longevity than other direct restorative materials, such as composite. On average, serve for 10 to 12 years, whereas resin-based composites serve for about half that time. resin-based composites 6.0 Silver-tin-copper alloys (Amalgam)

Silver-tin-copper alloys (Amalgam) Has bacteriostatic effectsbacteriostatic Can interfere the bacterial protein production, DNA replication, or other aspects of bacterial cellular metabolismproteinDNAmetabolism

34 Its main disadvantages are: poor aesthetics on anterior teeth the known toxicity of mercury. Concerns about possible harmful health effects from the low levels of mercury released from amalgam have resulted in a decline in the routine use of amalgam in recent years. 6.0 Silver-tin-copper alloys (Amalgam)

35 Other metals Tantalum Found to be highly compatible high density (16.6g/cm 3 ) poor mechanical properties Application restricted to a few applications such as wire sutures for plastic and neurosurgery and a radioisotope for bladder tumour.

36 Platinum Extremely corrosion resistant Poor mechanical properties Mainly used as alloys for electrodes in neuromuscular stimulation devices such as cardiac pacemaker. Because of their high resistance to corrosion Low threshold potential for electrical conductivity. Other metals

37 Corrosion is the unwanted chemical reaction of metals with its environment. Tissue fluids in the human body contains water, dissolved oxygen, proteins and various ions such as chloride and hydroxide. As a result the human body presents a very aggressive environment for metals used for implantation. 7.0 Corrosion of Metallic Implant

Corrosion of Metallic Implant Fundamental of corrosion Corrosion is an electrochemical process that involves transfer of electrons from one substance to another. Coupling of two reaction: Oxidation (generates electrons) Reduction (consumes electron) Corrosion occurs when metal atoms become ionized and go into solution to form a compound which flakes off or dissolves.

Corrosion of Metallic Implant Electrolyte contains ion in solution, serve to complete the electric circuit. Anions = negative ion which migrate toward anode Cations = positive ion which migrate toward cathode

40 At anode: Metal oxidizes by losing valence electron M → M +n + ne - At cathode: M +n + ne - → M 7.0 Corrosion of Metallic Implant

Corrosion of Metallic Implant As one moves down the table, the metals tendency for oxidation becomes higher and they are more active (anodic)

42 The galvanic series has been developed from data collected on metal corrosion in seawater. Provides a good indication of the relative activity of various metals in salt solution, similar to that found in the human body.

Where does corrosion occur? In region where two dissimilar metals in contact Implantation of dissimilar metals (mixed metals) is to be avoided, because: Galvanic corrosion may occur One which is most negative in the galvanic series will become anode, and the other one will become cathode. Region where there are variations in material homogeneity. Occur within a single material Grain boundaries are anodic with respect to the grain interior. Crack in material- matrix will become cathode, crack will become anode.

44 CORROSION DUE TO DEFECTS DURING FABRICATION. Crevice corrosion Pitting Corrosion Intergranular corrosion CORROSION DUE TO EFFECTS OF MECHANICAL ENVIROMENT Stress and Galvanic corrosion Stress corrosion cracking Fatigue corrosion Fretting corrosion 7.2 Types of corrosion

45 CORROSION DUE TO DEFECTS DURING FABRICATION. Crevice Corrosion Corrosion occurring in spaces to which the access of the working fluid from the environment is limited. These spaces are generally called crevice which is narrow, deep crack. Example: In between the screw and plate of a bone fixation device. Usually exhibit in stainless steel orthopaedic applications.

46 CORROSION DUE TO DEFECTS DURING FABRICATION.

47 Oxidation of the metal occur in crevice. The remainder of the piece become cathode. Depletion of oxygen in the crevice. Diffusion of Cl - ions into the crevice to balance the charge of the M +n ions created. The compound formed can react further to produce insoluble hydroxide and librate H +: MCl n + nH2O → M(OH) n + nH + Cl - Decrease in pH → A shift to acid conditions in the crevice → provide more corrosive environment Anode Cathode

48 Pitting corrosion Caused by same mechanism as crevice corrosion. Small defects on the surface of the material (e.g scratch). Passivation layer on the surface is disrupted. Leading to the formation of a relatively small anode and a large cathode. The anodic region undergo significant dissolution. This is dangerous type of corrosion because it ca undetected until device failure due to the small overall material loss. CORROSION DUE TO DEFECTS DURING FABRICATION.

Types of corrosion Intergranular Corrosion Devices fabricated by casting often have multiple grains Thus susceptible to intergranular corrosion. Grain boundaries will become anodic regions of the material. Grain will become cathode.

50 Grain (cathode) Boundaries (anode) Intergranular corrosion CORROSION DUE TO DEFECTS DURING FABRICATION.

51 CORROSION DUE TO EFFECTS OF MECHANICAL ENVIROMENT Stress and Galvanic corrosion Occur when two dissimilar metals in contact. One which is most negative in the galvanic series will become anode, and the other one will become cathode. Bending of metal rod or plate will cause: Tensile side → anode Compression side → cathode

52 CORROSION DUE TO EFFECTS OF MECHANICAL ENVIROMENT Stress corrosion cracking Occurs to a metal that is both under tension and subjected to a corrosive environment. Results in small crack that form perpendicular to the direction of applied stress. Crack propagate due to anodic dissolution at crack tip. This lead to brittle fracture.

53 Fatigue corrosion Continued bending, loading or motion around the implant may disrupt the passivating film formed on the metal and exposed the underlying surface, leading to corrosion of this area. This type of corrosion may significantly shorten the fatigue life of the implant Results in premature device failure. CORROSION DUE TO EFFECTS OF MECHANICAL ENVIROMENT

54 Fretting corrosion Not related to loading. Dependent on motion near the implant (abrasion, friction). Involves removal of the metal’s passivating layer by mechanical means. Can be seen around connection between fixation plates and bone screws. CORROSION DUE TO EFFECTS OF MECHANICAL ENVIROMENT