Calibration of I/P (current/Pressure) Honeywell Chapter 8 InstrumentationELC-213Today Presentation by Clifford T. Johnson, PE, Control Systems Engineer.

Slides:



Advertisements
Similar presentations
Modelling and Simulation 7. September 2014 / Dr. –Ing Naveed Ramzan 1 Instrumentation and control Department of Chemical Engineering, U.E.T. Lahore Pakistan.
Advertisements

Instructor: Lichuan Gui
Kit Building Class Lesson 4Page 1 R and X in Series Inductors and capacitors resist the flow of AC. This property is called reactance. Resistance also.
CHAPTER 3: SPECIAL PURPOSE OP-AMP CIRCUITS
Lecture Notes Part 4 ET 483b Sequential Control and Data Acquisition
[ 1 ] LVDS links Servizio Elettronico Laboratori Frascati INFN - Laboratori Nazionali di Frascati G. Felici LVDS links.

Control System Instrumentation
Characteristics of Instruments P M V Subbarao Professor Mechanical Engineering Department A Step Towards Design of Instruments….
EUT 1040 Lecture 10: Programmable Logic Controllers.
Pressure Measurement Video
TRANSDUCERS: VARIABLE RESISTIVE/CAPACITIVE/ INDUCTIVE
SENSORS AND TRANSDUCERS
Classification of Instruments :
AccuMax Multi-Point Injection Mechanics
Copyright CCNA 1 Chapter 4, Part 1 Cable Testing By Your Name.
Lecture 3: Bridge Circuits
Chapter 27 Lecture 12: Circuits.
1 Complex Gain: Basic amplifier concepts Q: What is a Phasor? A Phasor is an ac voltage or current that maintains the same phase with respect to a standard.
Presentation by Clifford T. Johnson, PE, Control Systems Engineer
Static Pressure Control Loop The purpose of the static pressure control loop is to maintain an optimal static pressure in the ductwork. The control loop.
1 INPUT & OUTPUT ■ INPUT * Voltage Side ( PT side ) Operational range : 0-110% Permissible over range : 150% for 10 seconds 120% continuously * Current.
ابزاردقیق ارائه دهم. The device has 2 input ports, named inverting ( - ) input and non-inverting (+) input. The output is simply an amplified signal of.
SENSORS MEETING THE NEEDS OF THE DAY  A device which converts energy or information in one form to another  In other words, a device which provides.
CHAPTER 18 Power Supplies. Objectives Describe and Analyze: Power Supply Systems Regulation Buck & Boost Regulators Flyback Regulators Off-Line Power.
InstrumentationELC-213 Presentation by Clifford T. Johnson, PE, Control Systems Engineer Instrumentation and Control Systems Documentation Today Honeywell.
CHAPTER 9 Control System Instrumentation
LECTURER PROF.Dr. DEMIR BAYKA AUTOMOTIVE ENGINEERING LABORATORY I.
LECTURER PROF.Dr. DEMIR BAYKA AUTOMOTIVE ENGINEERING LABORATORY I.
Flow Measurement Video Specifications & FlowELC-213Today Instrumentation and Control Systems Documentation Presentation by Clifford T. Johnson, PE, Control.
12 Transmission Lines.
Biomedical Instrumentation I
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 9 Computer-Based Instrumentation.
InstrumentationELC-213Today Presentation by Clifford T. Johnson, PE, Control Systems Engineer Instrumentation and Control Systems Documentation Honeywell.
EKT 451/4 SEM 2 Chapter 6 SENSOR & TRANSDUCER SHAIFUL NIZAM MOHYAR
InstrumentationELC-213Today Presentation by Clifford T. Johnson, PE, Control Systems Engineer Instrumentation and Control Systems Documentation Honeywell.
Calibration PT Honeywell Chapter 7 InstrumentationELC-213Today Presentation by Clifford T. Johnson, PE, Control Systems Engineer Honeywell Primer Auxiliaries.
Fundamentals of Electric Circuits Chapter 5 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
ELECTRICAL ENGINEERING Principles and Applications THIRD EDITION ALLAN R. HAMBLEY ©2002 Prentice-Hall, Inc. Chapter 9 Computer-Based Instrumentation Systems.
Chapter 27 Lecture 24: Circuits: II HW 8 (problems): 26.10, 26.22, 26.35, 26.49, 27.12, 27.30, 27.40, Due Friday, Nov.6.
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
Lecture 3: Bridge Circuits
Grounding.
Honeywell Chapter 2 SpecificationsELC-213Today Instrumentation and Control Systems Documentation Presentation by Clifford T. Johnson, PE, Control Systems.
Honeywell Chapter 1 SpecificationsELC-213Today Instrumentation and Control Systems Documentation Presentation by Clifford T. Johnson, PE, Control Systems.
社内資料社内資料 E-P Regulator for High Pressure up to 5.0MPa ITVX Series * This product is only for blowing, and does not have sufficient control for other application.
FUNDAMENTALS OF ELECTRICAL ENGINEERING [ ENT 163 ] LECTURE #10 ELECTRICAL MACHINES HASIMAH ALI Programme of Mechatronics, School of Mechatronics Engineering,
Advanced Process Control InstrumentationELC-213Today Presentation by Clifford T. Johnson, PE, Control Systems Engineer Honeywell Primer Chapter 6 Advanced.
Level Measurement Video
Avoid _____________ _____________ _____________ _____________ _____________ _____________.
EKT 314/4 WEEK 2 : CHAPTER 1 INTRODUCTION TO EI ELECTRONIC INSTRUMENTATION.
Chapter 9 CAPACITOR.
EKT 451 CHAPTER 6 Sensor & Transducers.
Introduction to Linear Voltage Regulators Krishna Kishore Reddy K 2010H223084H.
1 Transducers EKT 451 CHAPTER 6. 2 Definition of a Transducers   Transducer is any device that converts energy in one form to energy in another.  
Electric Pressure Transducer
Lecture 10: Programmable Logic Controllers
INTRODUCTION TO ELECTRONIC INSTRUMENTATION
Grounding.
HD POWER TRANSDUCER SERIES VOLT-DEMAND TRANSDUCER
HD POWER TRANSDUCER SERIES
INTRODUCTION TO ELECTRONIC INSTRUMENTATION
Characteristics of measurement systems
Lesson 11: Transducer Electrical Interfaces
BASICS OF MEASUREMENT AND INSTRUMENTATION
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
HD POWER TRANSDUCER SERIES
Chapter 5 Operational Amplifiers
EUT 1040 Lecture 10: Programmable Logic Controllers Unrestricted.
Presentation transcript:

Calibration of I/P (current/Pressure) Honeywell Chapter 8 InstrumentationELC-213Today Presentation by Clifford T. Johnson, PE, Control Systems Engineer Honeywell Primer: Noise Environments

HoneywellELC-213 Wire Function wiring

HoneywellELC-213 Chapter AC Load Suppression Suppression

HoneywellELC-213 AC Contact suppression Suppression

HoneywellELC-213 DC Suppression Suppression

noise can enter equipment by 1. Capacitive (or electrostatic) 2. Inductive (or magnetic) 3. Impedance. HoneywellNoiseELC-213 Signal cable should always be separated for power cable Never run in the same conduit and Use dividers in cable tray

HoneywellELC-213 Prevent Electrical Noise Suppression There are three ways to prevent electrical noise from interfering with the operation of the electronic digital equipment. Built-in noise rejection Separation of signal and power lines Noise suppression at source Ever wonder why Ethernet Cat5 cable is NOT shielded? ANS: It relies on the BALANCED LINE twisted pair design and differential signaling for noise rejection.

TransducerELC-213 Grounding I/P Never Grd Shield in the field Bend back and tape

OperationELC-213 I/P Principle of operation I/P

OperationELC-213 I/P Principle of operation I/P

AccuracyELC-213 I/P Accuracy I/P The accuracy of an I/P transducer is defined in several ways. The most important measure is linearity. This is measured as a percent of span. In this case, the span is 12 (15 minus 3) psig. So if the linearity of the I/P was 1% of span, then the possible variation could be 1% of 12 or 0.12 psig. So in this case, the expected output with a 12mA signal. The output should be 9 psig but could be between 8.88 – 9.12 psig. Linearity can be as low as 0.1% and as high as 3% of span, depending on the construction and cost of the I/P.

AccuracyELC-213 I/P Repeatability & Hysteresisis I/P Repeatability measures the ability of the unit to come back to the same pressure setting after resetting the input signal. Hysteresisis is the variation in the output pressure achieved when increasing the input signal versus decreasing the input signal. For example, when going from 4 mA to 12mA a certain pressure will be attained. A different output pressure will be achieved when going from 20mA to 12 mA.

SummaryELC-213 Accuracies are additive Accuracy Unless specified, these three measurements can be additive. Thus a 3-15 psig unit with +/- 1% linearity, +/- 1% Hysteresisis, +/- 1% repeatability, could be off by +/- 3%, or +/-.36 psig 3% span

CalibrationELC-213 I/P Zero Calibration I/P Always check the zero setting first. Apply the minimum electrical signal and observe the output pressure. It should be the minimum value of the pressure range. For example, a 4-20mA, 3-15 psig unit should give a 3 psig output at 4mA. If the output is not 3, turn the zero screw until the output pressure reaches 3. The screw may be turned in different directions depending on whether the unit is an I/P or E/P.

CalibrationELC-213 I/P Span Calibration I/P Once the zero has been set, apply the maximum electrical signal, in this case, 20mA. The output should be close to the desired output, in this case 15 psig. Turn the span screw in the appropriate direction to achieve the desired pressure. Some I/P’s have interactive zero and span. In that case, after adjusting the span, the zero will need to be adjusted again, especially if the span was adjusted by a large amount.

SupplyELC-213 I/P Media Supply I/P The most common media for I/P’s is compressed air. They can also be used with many other inert gases. However, due to the constant consumption of the media, one must consider the environmental impact of the release of gas into the environment. You should definitely check the specifications before using the I/P with media other than compressed air.

Cal FormELC-213 Calibration form I/P Use your Tag

AnalyzerELC-213 Calibration of Analyzers pH pH is one of the most difficult Analyzers to calibrate because the measurement is log

AssignmentELC-213 Homework ASSIGNMENT Web Link Find instructions on Internet for PID Control Modes. web page LINK only to me by Sunday Ex: Johnson-PID Modes- Ex: Johnson-PID Modes- AD All s Subjects and File names must have You will lose 1-3 points for incorrect subject Subjects Subject : Subject :Your last Name-Subject-Assignment Date (AD)

CalibrationELC-213 The End End M-Systems I/P you will be calibrating