Air-preheater for Conservation of Flue Gas Energy P M V Subbarao Professor Mechanical Engineering Department Minimize Final Exhaust Gas Temperature….

Slides:



Advertisements
Similar presentations
An Introduction To Marine Steam Propulsion Plant [Source: US Navy]
Advertisements

OFF DESIGN PERFORMANCE PREDICTION OF STEAM TURBINES
Antero Punttila Analyzing most typical energy saving measures Energy Efficiency of Steam and Condensate Systems Antero Punttila, Motiva Oy.
ENERGY CONVERSION MME 9617A Eric Savory
Final Audit :Utilization of Flue Gas Energy P M V Subbarao Professor Mechanical Engineering Department Minimize Final Exhaust Gas Temperature…. Properly.
A novel IGCC system with steam injected H2/O2 cycle and CO2 recovery P M V Subbarao Professor Mechanical Engineering Department Low Quality Fuel but High.
In India 65% of total power is generated by the Thermal Power Stations. Main parts of the plant are 1. CHP.
Convection in Flat Plate Turbulent Boundary Layers P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi An Extra Effect For.
Design Steps : Furnace Of A Steam Generator P M V Subbarao Professor Mechanical Engineering Department Selection of Geometric Parameters….
THERMAL POWER PLANT.
More Ideas for Compact Double Pipe HXs P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Ideas for Creation of Compact HX!!!
Generation and Control of Vacuum in Furnace
Power Plant Construction and QA/QC Section 2.4– Boiler Auxiliaries
SEMINAR ON BOILERS BOILERS. WHAT IS A BOILER? Boiler is an apparatus to produce steam.Thermal released by combustion of fuel is transferred to water which.
Vapor and Combined Power Cycles
P M V Subbarao Professor Mechanical Engineering Department I I T Delhi
Heat Exchangers with Cross Flow past Cylinders P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Another Common Industrial Application!!!
Lesson 15 Heat Exchangers DESCRIBE the difference in the temperature profiles for counter-flow and parallel flow heat exchangers. DESCRIBE the differences.
Cross Flow Heat Exchangers P M V Subbarao Professor Mechanical Engineering Department I I T Delhi A Major Element for the Success of Combustion based.
Closure to Furnace Analysis P M V Subbarao Professor Mechanical Engineering Department Verification of Simplified Analysis……
Steam Power Station Presented By Ashvin G. Patel Asst. Prof. (E.E.)
Performance Evaluation of A Steam Generator P M V Subbarao Professor Mechanical Engineering Department A Measure of Efficient Combustion …..
Selection of Optimal Air Fuel Ratio P M V Subbarao Professor Mechanical Engineering Department Efficient Combustion Requires Sufficient Air…..
ISAT Module V: Industrial Systems
Operation and Maintenance
STUDY OF BOILER’S ACCESSORIES
Prof. D.N. Reddy Director Centre for Energy Technology University College of Engineering Osmania University.
Heat Exchanger & Classification Prepared by: Nimesh Gajjar
Basic Analysis of Steam Generators P M V Subbarao Professor Mechanical Engineering Department Fundamental Ideas for Systematic Development of Steam Generators……
Energy And Environmental Technology
AIM :- TO STUDY ABOUT STEAM POWER PLANT
CHAPTER 5: Mass and Energy Analysis of Control Volumes
Theory of Heat Exchanging P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Understanding of Qualities of An Ideal Heat Exchangers…..
Generating Stations. Bulk electric power is produced by special plants known as generating stations or power plants. Depending upon the form of energy.
Welcome PRESENTATION BY ASHISH MISHRA.
STEAM POWER PLANTS.
A Seminar On Suratgarh Super Thermal Power Station (Raj.)
A seminar on Practical Training taken at KOTA SUPER THERMAL POWER STATION.
P M V Subbarao Professor Mechanical Engineering Department
Development of Simplified Model for Furnace Cooling Capacity P M V Subbarao Professor Mechanical Engineering Department Empirical Testing for Cooling.
Thermal Power Station.
THERMAL POWER PLANT.
SURATGARH SUPER THARMAL POWER STATION
Performance Analysis of Multi Stage Axial Flow Compressors
BOILER MOUNTINGS & ACCESSORIES
Training Presentation On Suratgarh Super Thermal Power Station (Raj)
Presentation on Steam Power Plants R.C.Chaturvedi
Selection of Rankine Cycles for Various Resources Match the Cycle and Resource … P M V Subbarao Professor Mechanical Engineering Department.
Effect of Furnace Heat Transfer on Maximum Cycle Pressure Understanding of Fuel to Cycle Connections….. P M V Subbarao Professor Mechanical Engineering.
CERTIFICATE This is to certify that the project work entitled “Different Power Plants“ Is being submitted by Name of the student : Enroll no.: Patel Akshaykumar.
7TH SEMESTER ,MECHANICAL ENGINEERING BRANCH
HEAT-GENERATING EQUIPMENT INTRODUCTION SELECTION EFFICIENCY FURNACES BOILERS CENTRAL HVAC SYSTEMS.
9-11 MARZO 2008 COGENERATION AND THERMAL RECOVERY.
CLASSIFICATION OF HEAT EXCHANGERS
Thermal power plant , panipat
Some University Economizer City Plan: Introduction; Steam generator components; Economizer; Advantages of economizer; Boiler economizer; Сonstruction.
Introduction And Thermal Power Plant
Energy Balance Analysis of A Furnace/Combustion System
Further Cooling of Furnace Gases
Cause-Effect Analysis of Steam Generator & Rule Based Design
ENERGY audit OF COMBUSTION SYSTEMS
Furnace Heat Transfer & Steam Generation
PERFORMANCE ANALYSIS OF COMBUSTION SYSTEMS
Thermo-hydraulics of Power Plant Steam Generators
Heat Recovery Steam Generators
Condenser in Power Plants
Pulverized Coal Combustion Systems
Anatomy & Organs of Power Plant Steam Generators
Combined Cycle Power Plants
Presentation transcript:

Air-preheater for Conservation of Flue Gas Energy P M V Subbarao Professor Mechanical Engineering Department Minimize Final Exhaust Gas Temperature…. Properly Utilize Enthalpy of Flue Gas….

Gas Temperatures Platen Super Heater: Inlet Temperature: C Outlet Temperature: C Final Super Heater: Inlet Temperature: C Outlet Temperature: C Reheater: Inlet Temperature: C Outlet Temperature: C Low Temperature Super Heater: Inlet Temperature: C Outlet Temperature: C Economizer: Inlet Temperature: C Outlet Temperature: C Steam Temperatures Platen Super Heater: Inlet Temperature: C Outlet Temperature: C Final Super Heater: Inlet Temperature: C Outlet Temperature: C Reheater: Inlet Temperature: C Outlet Temperature: C Low Temperature Super Heater: Inlet Temperature: C Outlet Temperature: C Economizer: Inlet Temperature: C Outlet Temperature: C

Furnace absorption Platen SH Pendent SH CSH Reheater Economizer Combustion LossesC & R losses Hot Exhaust Gas losses ~328 0 C

Design 1: 500 MW

LMTD for various Devices: Model 1

Design 1: 500 MW

DPNLSH Platen SHTR RHTRRHTR LTSH Economiser APH ESP ID Fan drum Furnace BCW pump Bottom ash stack screen tubes Thermal Structure of A Modern Fuel Fired SG

Thermal Balance in Air Pre-Heater. The energy rate gained by air The energy rate lost by flue gas Overall Coefficient of Heat Transfer, U Overall Convective rate of Heat Exchange

The Creative Design…… Heat exchanger is complete only if there are Donor, Receiver and Mediator in Equilibrium. Presence of all the three necessary? Time sharing & Space Sharing Time Sharing : Donor And Mediator for sometime and Mediator and Receiver for sometime : Repeat! Space sharing: All present always. Central Limit Theorem : It is impossible to have time and space sharing in one system. Time Sharing : Regenerators Space Sharing : Recuperators

The concept of Time Sharing At any time: The overall heat transfer coefficient, U OR At stead operation: OR

Stockholm 1920 The Ljungström Air Preheater

Historical Significance of Landmark Throughout the history of boilers there have been many advancements in order to obtain a better performance and lower fuel consumption. Ljungström Air Preheater invented by Fredrik Ljungström, then Technical Director at Aktiebolaget Ljungström Ångturbin (ALÅ) is the most successful invention. The first installation in a commercial boiler saved as much as 25% of the fuel consumption. In a modern Steam generator the Ljungström Air Preheater provides up to 20% of the total heat transfer in the boiler process, but the Ljungström Air Preheater only represents 2% of the investment.

Economic Impact of the Landmark The use of a Ljungström Air Preheater in a modern power plant saves a considerable quantity of fuel. The cost of the preheater is generally recovered after only a few months. The total world-wide fuel savings resulting from all Ljungström Air Preheaters which have been in service is equivalent to 4,500,000,000 tons of oil (1994). An estimate shows that the Ljungström Air Preheaters in operation annually saves about $30 Billion US. The distribution of thermal power capacity in which Ljungström Air Preheaters are installed over the world is shown in the table below.

Landmark Contribution to Development of New World Wide Industry The use of the Ljungström Air Preheater started in the 1920 s throughout the whole world. In the beginning the marketing of the Ljungström Air Preheater was made in close connection with ALÅ. but most of the deliveries have actually been made through a network of licensees throughout the world.

Rotary or Regenerative Air Pre-Heater

Stationary-Plate Type Air Pre-Heater

Regenerative Pre-Heaters Rotates with a low speed Rotor is divided into 12 or 24 sections and 12 or 24 radial divisions. Each sector is divided into several trapezoidal sections with transverse division plates. Heat storage pales are placed in these sections. Weight : 500 tons. This consists of : rotor, sealing apparatus, shell etc.

Schematic diagram of the rotary air preheater in thermal power plant.

Thermodynamic process and flow diagram

Leakage in APH

Multiple Channel RAPH

Fluid flows in rotary regenerator