1.1 Introduction 1.1.1 Energy of IR photon Near IR 12,800-4000 cm -1 Mid IR4000-200 cm -1 Far IR200-10 cm -1 Energy of IR photons insufficient to cause.

Slides:



Advertisements
Similar presentations
FT-IR Instrument 1. 2 i)Dispersive spectrometers or ii)Fourier transform spectrometers. Most commercial instruments separate and measure IR radiation.
Advertisements

Raman Spectroscopy A) Introduction IR Raman
Applications of IR spectroscopy
The Greenhouse Effect. Terrestrial Emissions Terrestrial emissions have energies corresponding to the infrared (IR) region of the electromagnetic spectrum.
Raman Spectroscopy Laser 4880 Å. Raman Spectroscopy.
METO 621 Lesson 6. Absorption by gaseous species Particles in the atmosphere are absorbers of radiation. Absorption is inherently a quantum process. A.
Chapter 17 Applications of Infrared Spectrometry Infrared spectrometry is applied to the qualitative and quantitative determination of molecular species.
Lecture 6. FT-IR and Raman Spectroscopy. FT-IR Analytical infrared studies are based on the absorption or reflection of the electromagnetic radiation.
Raman Spectroscopy Raman effect is a 2-photon scattering process
Raman Spectroscopy Laser 4880 Å. Raman Spectroscopy.
Infrared Radiation 780 nm m Near, Mid and Far
FT-IR Instrument. Components Source Michelson Interferometer Sample Detector.
Rotational Spectra Simplest Case: Diatomic or Linear Polyatomic molecule Rigid Rotor Model: Two nuclei joined by a weightless rod J = Rotational quantum.
FT-IR Instrument. Components Source Michelson Interferometer Sample Detector.
Infrared Spectroscopy Antonella Magnelli. Development Discovered in 1800 but commercially available in 1940s Prisms Grating Instruments Fourier-transform.
Introduction to Infrared Spectrometry Chap 16. Infrared Spectral Regions Table 16-1 Most used – 15.
Introduction to Infrared Spectrometry Chap 16. Quantum Mechanical Treatment of Vibrations Required to include quantized nature of E From solving the wave.
Introduction to Infrared Spectroscopy
Fourier Transform IR Spectroscopy Saptarshi Basu.
Lecture 3 INFRARED SPECTROMETRY
Spectral Regions and Transitions
Introduction and Applications of Infrared Spectrometry
Infrared Spectroscopy. Theory of Infrared Absorption Spectroscopy IR photons have low energy. The only transitions that have comparable energy differences.
Time out—states and transitions Spectroscopy—transitions between energy states of a molecule excited by absorption or emission of a photon h =  E = E.
 PART Requirements for Spectroscopic Techniques for Polymers 1. High resolution 2. High sensitivity (>1%) 3. High selectivity between molecular.
Lecture 6 Raman spectra of carbon nanotubes. Infrared (IR) spectroscopy IR 700 nm3500 nm400 nm Visible light IR IR spectra can be used to identify the.
Spectroscopic Analysis Part 4 – Molecular Energy Levels and IR Spectroscopy Chulalongkorn University, Bangkok, Thailand January 2012 Dr Ron Beckett Water.
Vibrational and Rotational Spectroscopy
1 University of Petra Faculty of Science & Arts Department of Chemistry Seminar I.R Spectroscopy By Firas Al-ouzeh Supervisor : Nuha I. Swidan Summer 2007.
Spectroscopy.  Spectroscopy is the study of the interaction of electromagnetic radiation with matter. There are many forms of spectroscopy, each contributing.
Pharmacy 325 Infrared (IR) Spectroscopy Dr. David Wishart Rm Ph Hours: anytime after 4 pm.
Advanced Spectroscopy 3. Infrared Spectroscopy. Revision 1.What molecular or structural features give rise to absorption of infrared (IR) radiation? covalent.
IR-Spectroscopy Introduction Theory Instrumentation Sample preparation Table and charts.
10-1 Application of IR Raman Spectroscopy 3 IR regions Structure and Functional Group Absorption IR Reflection IR Photoacoustic IR IR Emission Micro.
States and transitions
Soil Mid Infrared Spectroscopy Contact: World Agroforestry Centre (ICRAF), P.O. Box Nairobi, Kenya. Tel:
Chapter 12 Infrared Spectroscopy Jo Blackburn Richland College, Dallas, TX Dallas County Community College District  2006,  Prentice Hall Organic Chemistry,
(IR spectroscopy) is the subset of spectroscopy that deals with the infrared region of the electromagnetic spectrum. spectroscopy infraredelectromagnetic.
Important concepts in IR spectroscopy
Introduction to Spectroscopy Yongsik Lee.
INFRARED SPECTROSCOPY
Please read Chapter 4 in Archer Textbook
Copyright © 2010 Pearson Education, Inc. Lecture Outline Chapter 2 Light and Matter.
Raman Spectroscopy A) Introduction IR Raman
11-1 Infrared Spectrometry Wavelengths  0.78  m to 1000  m §3 regions àNear-, mid-, and far Theory Sources Instrumentation.
1.1 What’s electromagnetic radiation
Fourier Transform IR Spectroscopy. Absorption peaks in an infrared absorption spectrum arise from molecular vibrations Absorbed energy causes molecular.
Infrared Spectroscopy (IR) Fourier Transform Infrared (FTIR)
1 Increasing frequency CH 2 =CH-CH=CH 2 Absorption spectrum for 1,3-butadiene.
IR Spectroscopy CHM 411 Suroviec. I. Theory of IR Spectroscopy Frequency of absorbed radiation is the molecular vibration frequency responsible for absorption.
Introduction to Infrared Spectroscopy
Absorption Spectroscopy
Dr. S. M. Condren Chapter 16 An Introduction to Infrared Spectroscopy.
FTIR: Fourier Transform Infrared Spectroscopy
MOHAMED NIJAS V S5 I.S.P. CONTENT  SPECTROSCOPY.  IR SPECTROSCOPY.  MOLECULAR VIBRATIONS.  EXPERIMENTAL SETUP.  FUTURE DIRECTIONS.
INFRARED SPECTROSCOPY Pramod K Singh School of Basic Sciences &Research Sharda University, Greater Noida, INDIA.
© 2017 Pearson Education, Inc.
INFRARED SPECTROSCOPY
IR Spectroscopy سپکتروسکوپی ماتحت سرخ
Introduction and Principle of IR Spectrophotometry
Diatomic molecules
Fourier Transformation Infra-red
Analytical methods Prepared By Dr. Biswajit Saha.
INFRARED SPECTROSCOPY Dr. R. P. Chavan Head, Department of Chemistry
Chapter 17 Applications of Infrared Spectrometry
Raman Spectroscopy A) Introduction IR Raman
Presentation On INFRARED SPECTROSCOPY
Infrared Spectroscopy
IR-Spectroscopy Introduction Theory Instrumentation Sample preparation
Presentation transcript:

1.1 Introduction Energy of IR photon Near IR 12, cm -1 Mid IR cm -1 Far IR cm -1 Energy of IR photons insufficient to cause electronic excitation but can cause vibrational or rotational excitation Dipole moment changes during vibrations Magnitude of dipole moment determined by a. charge b. separation (vibrational or rotation causes varying separation)

*Molecule must have change in dipole moment due to vibration or rotation to absorb IR radiation (only in this case the alternating E field can interact with the molecule and cause change in amplitude of one of its motions) Molecule with permanent dipole moments are IR active

1.1.3 Types of molecular vibrations basic categories: - stretching: change in bond length, symmetric or asymmetric - bending: change in the angle, scissoring, wagging, rocking, twisting/torsion

H 2 CO vibrations 4 = 1165 cm -1 out-of-plane wagging 2 = 1756 cm -1 CO stretch 3 = 1482 cm -1 CH 2 scissors 5 = 2846 cm -1 aym CH stretch 6 = 1221 cm -1 in-plane CH 2 rock 1 = 2790 cm -1 CH 2 sys stretch

1.1.4 Vibrational modes Translation Rotation Vibration Non-Linear 3 3 3N-6 Linear 3 2 3N-5 Only some vibrational modes are IR active

1.1.5 Classical vibrational motion A system of two masses connected by a spring? Quantum treatment E 0 = ½ h m ground vibrational state ( =0) E 1 = 3/2h m first excited vibrational state ( =1)  E = h m Vibrational selection rule:  =  1 since levels are equally spaced- should see one absorption frequency

2.1 FT-IR Time-domain spectroscopy - changes in radiant power with time Fig (p.207) Unfortunately, no detector can respond on s time scale

2.1.2 Michelson interferometer Use Michelson interferometer to measure signal proportional to time varying signal - If moving mirror moves 1/4 (1/2 round-trip) waves are out of phase at beam-splitting mirror – no signal -If moving mirror moves 1/2 (1 round- trip) waves are out of phase at beam- splitting mirror –signal Difference in path lengths called retardation  Plot  vs. signal – cosine wave with frequency proportional to light frequency but signal varies at much lower frequency Fig (p.208)

One full cycle when movable mirror moves distance /2 (round trip = ) The velocity of moving mirror v MM Bolometer, photoconducting IR detector, etc. can “see” changes on s

Time-domain signal  frequency-domain signal Fig (p.210)

2.1.3 Resolution Two closely spaced lines only separated if one complete “beat” is recorded. As lines get closer together,  must increase Mirror motion is 1/2 , resolution is governed by distance moving mirror travels Advantages of FT-IR (reading assignment, will be in exam)

2.2 IR sources Fig (p.153)

2.3 IR transducer Pyroelectric - TGS (Triglycine sulfate) based on pyroelectric effect (temperature dependent capacitance) fast enough for FT-IR (but less sensitive than thermocouple) most common detector for FT-IR Photoconducting semiconductors (e.g., PbS, MCT, etc) resistance decreases with increase photon flux (promotion of electrons to conduction band) MCT (mercury telluride-cadmium telluride) about x100 sensitive than TGS, cooled to N2(liquid) temp to reduce thermal noise. Thermal couple– based on temperature detection (heating effect of radiation) poor sensitivity slow (ms response time) – not suitable for FT-IR

*Anharmonic oscillator: a. Electron repulsion (steeper at small distance) b. Dissociation (bond breaks at large distance) Consequences: -Harmonic at low -  E becomes smaller at high -Selection rules fails  =  1,  2,  3,..

3.1 Sample handling IR (especially FT-IR) is very widely used for qualitative quantitative Analysis of gases liquids solids Most time-consuming part is sample handling

3.1.1 Gases fill gas cell (1) transparent windows (NaCl / KBr) (2) long path length (10cm-10m) – few molecules

3.1.2 Liquids fill liquid cell (1) dissolved in transparent solvent – not water (attacks the window) (2) short path length ( mm) – solvent absorbs In the following figure, horizontal lines indicate useful regions Fig (p.456)

Fig (p.457)

Determining cell pathlength Get interference pattern due to interference of waves that are reflected between the cell windows (empty cell) Determination of the distance between the salt plates Fig (p.458)

3.1.3 Solids (1) make semi-transparent pellet with KBr (2) grind and mix with mineral oil to form mull. One drop (film) between NaCl plates.

3.2 Qualitative Analysis (1) Identify functional groups (group frequency region, cm -1 ) (2) Compare with standard spectra containing these functional groups (fingerprint region, 1200 – 600 cm -1 ) - use computerized spectral search engines - use IR assignments in conjunction with other info (e.g., chemical, physical, spectroscopic)

Group frequencies Approximately calculated from masses and spring constants Variation due to coupling Compared to correlation charts/database (Table 17-6, p )

Fig (p.460)

Fig (continued, p.461)

3.3Quantitative Analysis IR more difficult than UV-Vis because (1) narrow bands (variation in  ) (2) complex spectra (3) weak incident beam (4) low transducer sensitivity (5) solvent absorption IR mostly used for rapid qualitative but not quantitative analysis

Diffuse-reflection spectrometry Advantages (powdered samples) Instrumentation (an adapter fitting into the cell component of FT-IR) Fig (p.471)

Comparison of the absorbance spectrum (a) for carbazole with its diffuse-reflectance spectrum (b) Fig (p.471)

Fig (p.477)  Orbiting Mars Global Surveyor-Thermal Emission Spectra, providing measurement of the Martian Surface and atmosphere  mini thermal-emission spectrometer measured by the Mars rover Spirit, indicating composition of nearly soils and rocks