Reducing risk with Exposure Monitoring Equipment.

Slides:



Advertisements
Similar presentations
Gas Detection Instruments
Advertisements

Monitoring Equipment and Detection Devices Chapter 14.
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
Teledyne Analytical Instruments
© TDL Sensors Ltd 2012 Tunable Laser Gas Monitoring.
Sensor Operating Theory
Problems With Determining Oxygen Deficiencies in Ratios Used for Assessing Spontaneous Combustion Activity Darren Brady Manager OHECC Simtars Department.
Basic Chocolate Cake Kamryn Banks 10/31/2014 math 4 th period.
Page | 1 Confined Space Entry. Page | 2 Definition of a Confined Space Is large enough and so configured that an employee can bodily enter and perform.
Hazmat Industry Technician. Types of Equipment Monitoring equipment Detection devices Air sampling systems.
Company Confidential © 2005 All Rights Reserved. What is it? State-of-the-art: microprocessor-based, wall-mount gas monitor Easy installation and operation:
RECIPE FOR 1 CAKE 2 Cups Flour 2 Eggs 1 Cup Sugar 1 Tbs Baking Powder 1 Cup Water 1/3 Cup Oil.
November 2009 Principles of gas detection Slide 1 Confined Space Entry.
Gas Chromatography in the detection of Volatile Organic Compounds.
Chapter 29 Product Control and Air Monitoring. Introduction Product control techniques can provide quick reduction in damage Reduction of surface area.
Mine Rescue Gas Detection
THE LATEST DETECTION TOOLS FOR LEAK / ODOR RESPONSE, CARBON MONOXIDE AND CONFINED SPACE ENTRY Paul D. Wehnert Vice President – Sales & Marketing Heath.
Basic Air Monitoring Concepts And Use Of The Altair 4 Gas Meter
Air Monitoring Presented By: Etech Environmental & Safety Solutions, Inc.
Measurement of NO y During SCOS97-NARSTO Dennis R. Fitz University of California, Riverside College of Engineering Center for Environmental Research and.
Part 2 Direct Reading Instrumentation. Direct Reading Instruments Many different instruments Many different operating principles including: –Electrochemical.
1 When entering a confined space Before and during normal working in a Process or Hydrocarbon Area When breaking containment on a process system When hot.
ITX 4-Gas Detector Quick Reference Guide. Case:Type 304 Stainless Steel,.024" (.61mm) thick Dimensions:4.75" X 3.2" X 1.68" (121mm X 81mm X 43mm) Weight:18.5.
Altair® 5X MultiGas Detector Altair® 5X MultiGas Detector The ALTAIR 5X MultiGas Detector is to be used when performing a hazard assessment.
Ultima® X Series Gas Monitors
ALTAIR ® 5X Multigas Detector It’s what’s inside that counts!
ALTAIR ® 4X Multigas Detector It’s what’s inside that counts!
M40M Multi-Gas Monitor. Checking instrument: A. Checking instrument: 1.Turn the instrument on by pressing the power button on the control face panel for.
MULTI-GAS MONITOR FOR CONFINED SPACE APPLICATIONS
Blabo® Automated Tank Cleaning ExxonMobil 2009 Article Electrical standards Designed for operation in hazardous areas. Constructed for zone 1, and some.
Gas Alarm System 4th Floor, Kjemi V If Gas Alarm, What to do? 1.There is 1 min delay before signal goes to the fire brigades (if high alarm) 2.Hurry to.
HazMat Technician Mod 1 Unit 2 Slide 1 Ohio Hazmat & WMD Technician Module 1 Unit 2 Field Survey Instruments.
WELCOME TO Gas Tester Training O2, LEL Monitoring
Infrared Camera Use for VOC Inspections.
Tools Available for Real-Time Exposure Assessment Phil Smith, PhD, CIH CDR MSC, USN
MONITORING SYSTEM EVALUATION. INFORMATION GATHERING  Review previous LFG inspection reports  Identify specific probes to be sampled  Obtain monitoring.
Florida Operations Level Hazardous Materials Training Unit 5.5 MISSION SPECIFIC: Air Monitoring and Sampling.
Ch. 10 Representative Gases
Buildings and Structures 2 Fire Detection Systems.
E VERY L IFE H AS A P URPOSE… Toxgard ® II Gas Monitor.
Chocolate fudge cake Ingredients 100g butter 250g caster sugar 50ml sunflower oil 25g cocoa powder 2 teaspoons vanilla extract 4 medium eggs 80ml milk.
PID Gas Meter/Detector. Introduction Air monitoring data is useful for: *Assessing the health risks to the public and response workers. *Selecting personal.
ORION ®plus IR Detector [ Compact. Durable. Ingenious. ] When you need more versatility….
General Monitoring Practices Sugar Grove Fire Department Training and Education.
PAS-Intro1 Dated 24th Aug Copyright © Siemens AG 1999 All Rights Reserved Siemens Advanced Engineering Pte Ltd Process Analytical Services Division.
Redox and Combustion. Redox and Combustion: At the conclusion of our time together, you should be able to: 1.Identify a basic combustion reaction 2.Balance.
1 Setting Action Levels and Controlling exposure with Air Monitoring A review...
Module 6: Health and Safety Considerations for Ethanol-Blended Fuel Emergencies.
Sampling and Measurement for Inorganic Gaseous Pollutants.
E VERY L IFE H AS A P URPOSE… Ultima ® XI Gas Monitor.
© MSA 2015 Because every life has a purpose… Altair 5X with PID and Xtirpa Fall Protection Solutions 11/9/15 – Airgas Joe Gormley / Andy DeLair– MSA Safety.
5-MINUTE MUG CAKE. PURPOSE Students will: complete a quick lab for displaying safety and sanitation practices and following directions.
Transformer Gas Tester Agenda Application Historical Solutions RKI’s Solution Features & Benefits Marketing.
1 LANDFILL GAS TRAINING. 2 INTRODUCTION  TYPE OF MONITORING -Screening -Specialized  GOALS.
TOWARDS A TEST METHOD FOR HYDROGEN SENSOR PERFORMANCE NATHAN D. MARSH AND THOMAS G. CLEARY Fire Research Division, National Institute of Standards and.
If you can do Dimensional Analysis, you can do stoichiometry 640 Tricycles are made each week How many wheels must be made? Given: 640 Tricycles 640.
Air Monitoring It’s Not Just For Hazardous Materials Anymore Captain Mark J. Schmitt, EFO Greensboro Fire Department.
Bi-Weekly Safety Meeting November 29, The days of using canaries in mines as primitive gas detectors are long gone..they've been replaced by fixed.
1 Emergency and Disaster Response to Chemical Releases Monitoring Module 4.
Environmental Incidents Management Training Programme AN AWARENESS PRESENTATION BY – DAI BOYLE & KEITH MEREDITH (MID & WEST WALES & SOUTH WALES) ASSISTANT.
Misuse of Combustible Gas Meters Supervisor Training 1/11/08.
AIR CLIMATE & ENERGY RESEARCH PROGRAM B U I L D I N G A S C I E N T I F I C F O U N D A T I O N F O R S O U N D E N V I R O N M.
Excavation & Trenching Awareness Plus
Atmospheric Monitoring. ATMOSPHERIC MONITORING INSTRUCTIONAL GOAL The participant will understand the need for atmospheric monitoring and the types, uses,
How to ensure Safety? Calibration vs Functional (Bump)Test Differentiate between calibration and functional (bump) test functional test –the sensors.
Rev. 1 © Chevron 2009 Gas and Vapor Detection Awareness Plus.
Venn Diagrams.
Jim Vermeulen MSA Territory Manager
Principles of Natural Gas
Stoichiometry ICS III Week 6.
Presentation transcript:

Reducing risk with Exposure Monitoring Equipment

What we know What we don’t know What we must assume What we must never assume Components of risk assessment What is the conclusion of risk assessment? The definition of acceptable risk

PID and LEL monitors Do they keep you safe?

These machines are DUMB! The value displayed is a TOTAL concentration of all DETECTED compounds AS IF (selected compound) Indicative at best

Calibrate to Chocolate: Display 500 Chocolate Display Vanilla (response factor 8): 4000 Vanilla Display Cake (response factor 0.002): 1 Cake 300 Chocolate (RF 1) 200 Flour (RF 0.25) 200 Sugar (RF 0.47) 6 Cocoa (RF 1.16) 150 Sunflower oil (RF 0.1) 300 Soured cream (RF 0.08) 2 Egg (RF N/A) 1 Vanilla Extract (RF 8)

PID : Photo Ionisation Detector Broad spectrum Sensitive Non destructive Low cost Cannot see smaller/lighter compounds e.g. methane UV Lamp ionises the gas sample. The free electrons are then counted and this value is converted and displayed as gas concentration (typically in ppm).

LEL and close space monitors Lower Explosive Limit Catalytic diffusion sensor burns available volatiles and converts the energy value to display %LEL Broad spectrum Low cost Can detect smaller/lighter compounds (methane) O 2 H 2 S CO LEL

%VOL - %LEL - PPM EXAMPLE: Pentane 1%VOL―75%LEL―10,000ppm 1%LEL―0.13%VOL―133ppm 1ppm―0.0075%LEL―0.0001%VOL Typical resolution for LEL monitors 1.0%LEL Typical resolution for PID 1ppm Best resolution for PID 1PPB!

Correction factors: Calibration gas and Action alarms Correction factors are not absolute Sensor type/manufacturer Calibration gas:  Pentane/Methane?  Isobutylene? Are alarms preset? Is this arbitrary?

Other factors Weather conditions Sensor inhibitors: Methane, Nitrogen, Carbon monoxide Sensor poisoning: Silicones Sensor reaction time: Pentane/methane Personal proximity

ZERO Nominal drift Who do you trust? Warm up period Ambient or absolute? Carbon filter

Bump testing and Calibration Ensure adequate warm up period Pump stall test Bump test first Potential issues: No gas, blocked regulator, cold machine, contaminated filters, incorrect gas selection When to calibrate? Potential issues: as above Gain?

Are these machines DUMB? It is not the tools we use which make us good, but rather how we employ them. These tools help you to redefine the risk and revaluate your own acceptable risk