David Followill, Ph.D. Radiological Physics Center

Slides:



Advertisements
Similar presentations
Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Advertisements

RapidArc plan verification using ArcCHECK™
Esteban Fabián Boggio 1 Lucas Provenzano 2 Sara Gonzalez 2,3 Sara Gonzalez 2,3 Juan Manuel Longhino 1 1 Bariloche Atomic Center, Atomic Energy National.
Energy deposition and neutron background studies for a low energy proton therapy facility Roxana Rata*, Roger Barlow* * International Institute for Accelerator.
Photon Beam Monitor-Unit Calculations
Algorithms used in heterogeneous dose calculations show systematic error as measured with the Radiological Physics Center’s anthropomorphic thorax phantom.
Maria Skłodowska-Curie Memorial Cancer Centre and Institute of Oncology, Warsaw, Poland 8th ECMP, Athens, Dosimetry audits in radiotherapy.
Evaluation of the characteristics of TLD LiF:Mg.Ti-100 Powder: A Measure of Consistency Between Multiple Batches of Powder Paola Alvarez,Jose Francisco.
MONTE-CARLO TECHNIQUES APPLIED TO PROTON DOSIMETRY AND RADIATION SAFETY F. Guillaume, G. Rucka, J. Hérault, N. Iborra, P. Chauvel 1 XXXV European Cyclotron.
Radiation Exposure, Dose and Relative Biological Effectiveness in Medicine Background Image:
Measurement of Absorbed Dose (6)
Tissue inhomogeneities in Monte Carlo treatment planning for proton therapy L. Beaulieu 1, M. Bazalova 2,3, C. Furstoss 4, F. Verhaegen 2,5 (1) Centre.
At the position d max of maximum energy loss of radiation, the number of secondary ionizations products peaks which in turn maximizes the dose at that.
Electron Beams: Physical Principles and Dosimetry
Photon and Energy Fluence
Beam Therapy Equipment 3 Patient Treatment and Accessories.
Dose Distribution and Scatter Analysis
Results The measured-to-predicted dose ratio criteria used by the RPC to credential institutions is , however for this work, a criteria of
Quality Control in Radiation Therapy, A New Concept: Dosimetry Check
Introduction Ion recombination is approximately corrected for in the Task-Group-51 protocol by P ion, which is calculated by a two-voltage measurement.
Measurement of Dose to Critical Structures Surrounding the Prostate from Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional Conformal Radiation.
Patient Plan Results: Table 3 shows the ratio of the Pinnacle TPS calculation to the DPM recalculation for the mean dose from selected regions of interest.
Test of the proposed method Introduction CCD Controller CCD Illuminator gel Filter 585nm Assembling the phantom before its irradiation. The phantom, ready.
Radiation Protection in Radiotherapy
In vivo dosimetry Eirik Malinen Eva Stabell Bergstrand Dag Rune Olsen.
G. Bartesaghi, 11° ICATPP, Como, 5-9 October 2009 MONTE CARLO SIMULATIONS ON NEUTRON TRANSPORT AND ABSORBED DOSE IN TISSUE-EQUIVALENT PHANTOMS EXPOSED.
Surface dose prediction and verification for IMRT plans using line dose profiles † Ronald E. Berg, † Michael S. Gossman and ‡ Stephen J. Klash † Erlanger.
OSL Albedo Neutron Dosimeter
CT physics and instrumentation
Response of the sensors to different doses from tests in Israel Radiotherapy is used as a treatment in around 50% of cancer cases in the UK. Predominantly,
The RPC Proton Therapy Approval Process
Ye, Sung-Joon, Ph.D. Ove, Roger, M.D., Ph.D.; Shen, Sui, Ph.D.
Application of a 2-D ionization chamber array for dose verification of dynamic IMRT with a micro-MLC Fujio ARAKI, PhD 1, S. TAJIRI 2, H. TOMINAGA 2, K.
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
Radiological Physics Center David Followill, Ph.D. and RPC Staff.
Araki F. Ikegami T. and Ishidoya T.
AIR CORE SCINTILLATION DOSIMETER SUMMARY We have shown that Cerenkov light can be reduced to a negligible level in scintillation dosimetry by using an.
Shielding Measurements For A Proton Therapy Facility S. Avery, K. P. Risolo, M. Bartels, C. Ainsley, J McDonough, R. L. Maughan University of Pennsylvania.
Introduction The Radiological Physics Center (RPC) anthropomorphic quality assurance (QA) phantom program is one tool the RPC uses to remotely audit institutions.
Determining Radiation Intensity
F. Foppiano, M.G. Pia, M. Piergentili
Neutron measurement with nuclear emulsion Mitsu KIMURA 27th Feb 2013.
P. Rodrigues, A. Trindade, L.Peralta, J. Varela GEANT4 Medical Applications at LIP GEANT4 Workshop, September – 4 October LIP – Lisbon.
Optimization of Volumetric Modulated Arc Therapy (VMAT) Planning Strategy Using Ring-shaped ROI for Localized Prostate cancer Kentaro Ishii, Masako Hosono,
TLD POSTAL DOSE QUALITY AUDIT FOR 6MV AND 15MV PHOTON BEAMS IN RADIOTHERAPY CLINICAL PRACTICE Sonja Petkovska 1, Margarita Ginovska 2, Hristina Spasevska.
Photoneutron Distributions around 18 MV X-ray Radiotherapy Accelerators using Nuclear Track Detectors Fazal-ur-Rehman, H. Al-Ghamdi, M. I. Al-Jarallah.
24 th ICNTS Design and test of an albedo personal neutron dosemeter based on PADC detectors R. Bedogni a, A. Esposito a, G. Gualdrini b, R. Mishra c, S.
Thickness of CZT detector 110 MeV140 MeV DETECTOR A (1 mm CZT + 5 mm CZT) DETECTOR B (1 mm CZT + 10 mm CZT) DETECTOR C (1 mm CZT + 15 mm CZT) A. Generation.
1 A protocol for the determination of absorbed dose from high energy photon and electron beams AAPM TG-21 Protocol (Med Phys 10: , 1983) 和信治癌中心醫院.
Commissioning of a commercial treatment planning system for IMAT and Dose Painting treatment delivery. G. Pittomvils 1,,L. Paelinck 1, F. Crop 2, W. De.
The Effects of Small Field Dosimetry on the Biological Models Used In Evaluating IMRT Dose Distributions Gene Cardarelli,PhD, MPH.
Measurements of the photon and neutron dose delivered to organs outside the radiation beams for 3DCRT and IMRT radiotherapy A. Kowalik 1, W. Jackowiak.
Adapting A Clinical Medical Accelerator For Primary Standard Dosimetry
AAPM TG-51 Protocol (Med Phys 26: , 1999)
E. Mezzenga 1, E. Cagni 1, A. Botti 1, M. Orlandi 1, W.D. Renner 2, M. Iori 1 1. Medical Physics Unit, ASMN-IRCCS of Reggio Emilia, Italy 2. MathResolution.
Retroactive Calculation of TLD and Film Dose in Anthropomorphic Phantom as Assessment of Updated TPS Performance H. Alkhatib 1, S. Oves 1, B. Tsang 1,
CHAPTER 3 DOSE DETERMINATION FOR EXTERNAL BEAMS
A. Sánchez-Reyes. , N. López Vilanova+, A. Vila. , M. A. Duch+, A
Electron Beam Therapy.
EURADOS Working Group 9: Radiation Dosimetry in Radiotherapy
Very High Energy Electron for Radiotherapy Studies
Absolute Dose Measurement
A system of dosimetric calculations
David Sutton or Colin Martin But Borrowed from Jerry Williams
Arghya Chattaraj, T. Palani Selvam, D. Datta
أجهزة العلاج الإشعاعي Clinical Radiation Generator
Task Group 158 Measurement and Calculation of Doses Outside the Treatment Volume from External-beam Radiation Therapy Treatment Eric E Klein, Ph.D.
Ch 10. A System of Dosimetric Calculations
Innovations in the Radiotherapy of Non–Small Cell Lung Cancer
Hot and cold spots are common problems associated with planning:
Presentation transcript:

Out-of-field Dosimetry for Secondary Cancer Studies: Past Experience and Future Needs David Followill, Ph.D. Radiological Physics Center U. T. M. D. Anderson Cancer Center

Introduction As we have all known for a long time: Patients undergoing radiation therapy are exposed to secondary radiation (radiation out of the treatment field). Secondary radiation is composed of photons, and at high treatment energies (above 8 MV), neutrons, which are produced in the accelerator head.

Introduction - Photons Secondary photon radiation composed of scatter and leakage. Scatter from within patient and off of collimators is dominant source near the treatment field. Leakage through the accelerator head is the dominant source away from the treatment field.

Introduction - Neutrons Neutrons are produced primarily by photons striking the primary collimator, jaws, and target. Neutrons are important because of their high RBE. ????????

Why all this Concern? There are now new treatment techniques and devices being used: Proton machines Tomotherapy units CyberKnife units IMRT delivery The new treatment techniques and/or devices are designed to deliver high dose gradients such that the target gets a high dose and the surrounding normal tissues get a lower dose. The great dose distributions sometimes come at a cost!

Why all this Concern? Amount of secondary radiation is a function of the amount of beam-on time. Some IMRT treatments may require up to 4 times as many MU’s to deliver as conventional treatments. For deep treatment sites, low energy treatments typically require more MU’s than high energy treatments. High energy x-rays and protons produce neutrons Bottom Line: More MU’s mean more secondary radiation.

Why are we Concerned? LNT – BEIR VII Linear Exponential (Gray 1965, Schneider et al. 2005) model suggested from human, animal, and in vitro data Linear Plateau (Ron 1998) derived from human epidemiological studies of radiation-induced breast, bladder, and stomach cancers Hall 2006

This is what started it ALL Likelihood of Secondary Fatal Malignancy (%) Calculated Risk estimates Followill et al (1997)

Where are we Concerned? Secondary radiation in the “Patient Plane”!!

Let’s First Worry about Photons Early measurements – early 80’s Ion chambers in large water phantoms Large volume ion chambers (0.3 – 30 cc) Scanning tanks

More Measurements Phantoms began to more closely approximate actual patient geometry Using cylindrical ion chambers

More Measurements Solid geometric phantoms also used Using TLD, diodes and 0.6 cm3 ion chambers Mutic et al (1998)

More Measurements Solid geometric phantoms also used Using cylindrical small volume ion chambers Klein et al. (2006)

Most Recent Measurements Anthropomorphic Rando phantom with TLD -100 and 700 depending on x-ray energy at 10 specific organ sites. 3 TLD at each location. Kry et al (2005)

Adult Procedure Adult Prostate Treatment with TomoTherapy and CyberKnife units Same prescription for all treatment devices Common TLD placement in phantom organ locations (2 TLDs) Starting with the adult prostate treatment.. 2 TLD at each organ location Pinnacle used for IMRT plans, HI-ART TPS was used to develop the tomo plans Tried to limit variables to come up with the most comparable tx plans: -Same Rx -Similar dose objectives -Same CT and contours

Pediatric Procedures Pediatric TomoTherapy Cranio-Spinal Irradiation (CSI) and CyberKnife GBM treatment Same prescription for 3D and Tomotherapy treatment plans IMRT and CyberKnife treatment plans TLD and EBT film placement in pediatric phantom Organ doses from TLD-100 EBT film validation of TPS calculations Because of helical delivery, many organs in primary beam -> need whole organ average -> EBT film used to verify TPS so that I could use the TPS’s DVH tool later for whole organ average Pinnacle used for 3D HI-ART TPS used for tomo

Photon Measurement Cautions Biggest issue: low doses = very low rdgs. Increase in uncertainty of measurements Long exposure times Need for multiple rdgs. at each point. Rdg. location (air vs. phantom) or at what depth? Point vs. volume measurements. Neutron component for high X-ray energies

Photon Dose Equivalent as a percent of dose at dmax vs. Distance

Neutron Measurements Neutron fluence measured with gold foils. 197Au(n,g)198Au Count the g,b emissions of the foils, convert to neutron fluence by NIST traceable conversion factor: Gold foils detect thermal neutrons. Bare gold foils measured the thermal neutron fluence. Fast neutrons are thermalized by moderators. Gold foils placed in moderators thereby measure the fast neutron fluence.

Neutron Measurements Determining neutron dose equiv. comprises several steps Obtain NIST traceable calibration Measure neutron fluence Calculate neutron dose equivalent at dmax Calculate neutron dose equivalent at depth

Neutron Measurements Bonner sphere system to measure the fluence from which the neutron spectrum is deconvolved. Howell et al (2006)

Neutron Measurements Bubble detectors or neutron meters

Neutron Contribution (%) to Secondary Dose Data from S. Kry

Neutron Fluence Fast neutron fluence measured on CAX and out of field. Fast neutron fluence out of field varied by less than the uncertainty in the dosimeter. Fast neutron fluence assumed constant out of field. For each distance from central axis, the neutron fluence was broken down into 12 components to account for energy and geometry. Neutron fluence was examined at the same 10 points as where the photon dose was measured.

Neutron Measurement Cautions Gold foil activation – not for everyone. NIST traceability Still the “gold” standard Low doses = very low rdgs. Increase in uncertainty of measurements Long exposure times Need for multiple rdgs. Along patient plane. Measurement variability among the different neutron dosimeters Difficulty measuring the neutron dose at depth in a patient

Dose Equivalent per Complete Prostate Treatment (photon and neutron) Data from Kry et al, S. Lazar, M. Bellon

Risk (%) of Secondary Cancer per Complete Prostate Treatment (photon and neutron) Data from Kry et al, S. Lazar, M. Bellon

Dose Equivalent to Edge of Stomach

Dose Equivalent and Risk (%) per Complete Pediatric GBM Treatment New optimization and tuning tools as well dose homogeneity

Now let’s include Proton Treatments Seems that every other day there is a new proton facility being built

Is there any Secondary Radiation to worry about? YES! Proton beams generate neutrons by interacting with the scattering systems, range modulator wheel, collimators and even the patient

How significant can this be? Slide coutesy of J Fontenot Hall (2006)

Neutron Measurements Measured and calculated data is sparse Results are not consistent Measurement techniques are not consistent Many different factors affect neutron production Machine type (synchrotron vs cyclotron) Proton energy Range modulation Field size Lateral scattering technique

Bonner Sphere Extension The BSS and BSE response function from thermal to 15 MeV is verified and corrected using AmBe & Cf-252 source at Georgia Tech. The response function from 15 MeV up to 800 MeV is corrected using the 800 MeV neutron beam at LANSCE Slide courtesy of Rebecca Howell

Experimental Setup Head Hip 23.5 cm 23 cm Shoulder

Neutron Measurement Cautions Neutron energies much higher than observed around electron accelerators Is your neutron calibration technique calibrated appropriately for these “neutrons”? Long exposure times Moderators used on electron accelerators are not adequate.

Comparison of the doses in the pediatric CranioSpinal case treated by 3D-conventional, tomotherapy, and proton therapy Organ site 3D 6 MV (cGy) TomoTherapy (cGy) Proton (120-180 MeV) (cSv) Thyroid 2797 (12) 362 (12) 22 Lt. Breast Bud 152 (9) 437 (6) Heart center 2957 (41) 865 (16) 21.8 Heart edge 2345 (18) 438 (16) Lt. Lung center 226 (13) 907 (43) Lt. Lung Edge 242 (33) 446 (9) Liver Center 2583 (18) 1107 (124) Liver edge 217 (14) 545 (16) Lt. Kidney 221 (6) 748 (83) Bladder 195 (11) 77 (2) 17.7 Pelvic 86 (4) 528 (30) Lt. Ovary 322 (60) 135 (22) Data from S. Lazar and Z. Wang, MDACC

Summary No consensus as to the best measurement technique. Calculations will play a larger role in the future. Increases in the secondary dose is highly dependent on the number of MUs and photon energy. Measurement of the secondary dose requires an established NIST traceable technique and characterization of the dosimeters at the appropriate energies. New treatment planning software with better optimization routines have reduced the number of MUs per treatment reducing the secondary doses. Neutron dose may play less of a role than previously thought.

I believe this risk to be small regardless of the treatment technique Take Home Message Measurement techniques are maturing. Patient models and dose calculations are more sophisticated and accurate. Biggest uncertainty is the RISK estimate There are many factors to be considered in the treatment of a patient and the risk of a secondary cancer is only one of many. I believe this risk to be small regardless of the treatment technique