Week one Chapters one and two

Slides:



Advertisements
Similar presentations
ELECTROMAGNETIC RADIATION
Advertisements

X-rays and their ability to
Producing an X-ray Exposure
Chapter 11 Prime Factors.
Radiation Safety and Production of X-Rays
The Generation of X-ray:
Physics of X-rays By Dr. Amr A. Abd-Elghany.
Chapter’s 2, 3. & 4 By Garland Fisher
Chapter 7 Radiographic Image Formation and Exposure Factors.
RADIOLOGY. NEXT GENERATION SCIENCE / COMMON CORE STANDARDS ADDRESSED! CCSS.ELA-Literacy.RST Determine the central ideas or conclusions of a text;
Chapter 6 Control of Secondary and Scattered Radiation.
Dental X-ray Machine 118 Radiology.
Electrons The discovery of the electron was a landmark
ACVR Artifacts Artifacts of Diagnostic Radiology
X-radiation. X-rays are part of the electromagnetic spectrum. X-radiation (composed of X-rays) is a form of electromagnetic radiation. X- rays have a.
Radiation Physics II.
Medical Imaging X-Rays I.
Section 25.1 – Properties of Light pp
7.6.a Students know visible light is a small band within a very broad electromagnetic spectrum.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods X-ray Instrumentation Part 1.
Radiography Introduction. Objectives To describe  Properties of x-rays  Production of x-rays  Formation of radiographic image  Components of an x-ray.
Factors affecting the X-Ray output
X-Ray Production & Emission
X-Ray Production & Emission
Reference Reading Chapter 2: pp  X-rays are produced within the dental x-ray machine  The x-ray machine can be divided into 3 study areas.
Reference Reading: Chapter 2, pp 18- end of chapter.
RADIOLOGIC IMAGING EQUIPMENT 1. THE X-RAY ROOM 2.
DMI 261 Radiation Biology AndProtection. Unit 2 RADIATION Electromagnetic Spectrum –The frequency range of electromagnetic radiation and the photon wavelength.
Ch. 2 – Anatomy of the X-ray Machine
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
LIGHT.
Lecture (2). 2 1.Explain how to produce x-rays and discuss its properties 2.List the basic components of the radiographic machine and identify primary.
Fundamentals of X-ray Production
RTEC A - WEEK 3 GENERAL SCIENCE REVIEW & X-RAY PRODUCTION IN THE TUBE.
Prime Exposure Factors 1
Chapter 2 The X-ray Beam.
Introduction to Dental Radiography and Equipment
Basic radiation protection & radiobiology
Photon Tissue Interactions
The electron.  An indivisible quantity of charge that orbits the nucleus of the atom.
Radiographic Equipment
X-rays discovered in 1895 by Wilhem Roentgen Roentgenology – Branch of medicine dealing with x-ray or gamma rays in diagnosis and treatment. Radiology.
Fundamentals of X-ray Production By Professor Jarek Stelmark.
Attenuation As x-rays pays through matter, the exit beam will contain less photons than the entrance beam. This reduction in the quantity of photons is.
Medical Equipment Technology Department 1 Introduction to Biomed. Imaging Systems Lecture No.5-6 Dr. Yousif Mohamed Y. Abdallah.
Chapter: Electromagnetic Radiation Table of Contents Section 1: What are electromagnetic waves? Section 2: The ElectromagneticThe Electromagnetic Spectrum.
RTT 425 Radiation Therapy Physics Radiation Quality, Chapter 4 From Stanton and Stinson: Applied physics for Radiation Oncology.
Tube Exposure Factors Math Technique Contrast and Density
Introduction By Dr. Nimer Khraim DVMS,BVMS,MVSc.
Welcome to Radiology Introduction and Chapter 1. What to Expect You are going to learn a lot in a short period of time. This is a very fast paced class,
RTEC A - WEEK 4 GENERAL SCIENCE REVIEW & X-RAY PRODUCTION IN THE TUBE
X-ray tube.
An early x-ray by Wilhem Rontgen
Radiology. The Cathode… Provides a source of electrons and directs the electrons towards to anode. The cathode has a coiled wire filament that emits electrons.
DR.S.KARTHIGA KANNAN PROFESSOR ORAL MEDICINE & RADIOLOGY.
 Matter is any thing that occupies space & has mass  Present in three states: solid, liquid, & gas  It could be divided into elements & compounds 
8 November 1895, produced and detected electromagnetic radiation in a wavelength range today known as X- rays or Röntgen rays, electromagnetic radiationwavelengthX-
AJADI ADETOLA DEPARTMENT OF VETERINARY MEDICINE AND SURGERY.
Chapter1 & 9 History of Radiology and X-ray Tube
Fundamentals of radiography.
Introduction to Radiography
X-RAY PRODUCTION AND EXPOSURE FACTORS
Characteristics of EM Waves
X-Radiation.
Exposure Factors Chapter 4
Resident Physics Lectures (Year 1)
Radiology Basics Dental Assistant Registration Course
Radiation Safety Dental Assistant Registration Course
Resident Physics Lectures (Year 1)
Presentation transcript:

Week one Chapters one and two Radiology Week one Chapters one and two

Key Terms Please know key terms for quiz on Friday

Properties of x-rays Produced by the conversion of electric energy into radiation Invisible Travel in straight lines Can penetrate opaque tissues and structures Can affect a photographic emulsion or digital sensor Can adversely affect human tissue

History of Dental Radiography 1895 Discovery of x-rays W.C. Roentgen 1896 First dental radiograph O.Walkhoff First dental radiograph in US (Skull) W.J. Morton First dental radiograph in US (live patient) C.E. Kells 1913 First prewrapped dental films Eastman Kodak Company First x-ray tube W.D. Coolidge 1923 First dental x-ray machine Victor X-Ray Corp, Chicago

Atom – a fundamental unit of matter Consists of Two Parts: Nucleus Orbiting Electrons

Made of one atom

Dental x-ray production

Ionization=converting atoms into ions Ion pair

Electromagnetic Radiation Electromagnetic Radiation An x-ray is one type of electromagnetic radiation. Electromagnetic radiation represents the movement of energy through space as a combination of electric and magnetic fields. All types of electromagnetic radiation, which also includes radiowaves, tv waves, visible light, microwaves and gamma rays, travel at the speed of light (186,000 miles per second). They travel through space in wave form.

W F = 3 W F = 2 D The waves of electromagnetic radiation have two basic properties: wavelength and frequency. The wavelength (W) is the distance from the crest of one wave to the crest of the next wave. The frequency (F) is the number of waves in a given distance (D). If the distance between waves decreases (W becomes shorter), the frequency will increase. The top wave above has a shorter wavelength and a higher frequency than the wave below it.

Which of the above has the lowest frequency? Cosmic rays radio waves tv waves visible light x-rays gamma rays cosmic rays Which of the above examples of electromagnetic radiation has the shortest wavelength? Which of the above has the lowest frequency? Cosmic rays Radio waves

Bremsstrahlung/General/Braking Radiation Braking = sudden stopping of high speed electrons when they hit the tungsten target in the anode that causes radiation. 70% (most) x-rays are produced in this manner.

Characteristic Very small amount of x-ray production. Can only be produced at 70 kVp and above. Causes not only radiation but ionization.

Defining terms Primary Radiation – penetrating or useful beam Secondary Radiation – created when the primary beam interacts with matter. Scatter Radiation – a form of secondary radiation that is deflected in all directions. Harmful to patient and radiographer

Interactions of X-radiation What happens after an x-ray exits the tubehead? 1. Can pass through the patient without any interaction 2. X-ray photons can be completely absorbed by the patient 3. X-ray photons can be scattered Compton scatter Coherent scatter

Compton Scatter Compton effect accounts for most of the scatter radiation. Ionization takes place

Coherent Scatter No change in the atom occurs X-ray photon simply undergoes a change in direction.

X-ray Equipment X-ray equipment has three basic components: 2 1 3 X-ray equipment has three basic components: (1) the x-ray tubehead, which produces the x-rays, (2) support arms, which allow you to move the tubehead around the patient’s head and (3) the control panel, which allows you to alter the duration of the x-ray beam (exposure time) and, on some x-ray machines, the intensity (energy) of the x-ray beam.

X-ray Tubehead PID (cone) degrees The x-ray tubehead is attached to the support arms so that it can rotate up and down (vertically;measured in degrees) and sideways (horizontally) to facilitate proper alignment of the x-ray beam. The PID (Position Indicating Device) is attached to the x-ray tubehead where the x-ray beam exits and it identifies the location of the x-ray beam. Some people refer to the PID as a “cone”; the PID’s on very old x-ray machines used to be coneshaped.

mA control exposure time kVp control The control panel, like the one above left, allows you to change exposure time but nothing else. Some machines, like the one above right, have controls for changing the mA and kVp settings in addition to exposure time. The individual controls will be discussed more later.

X-ray Tube X-rays are produced in the x-ray tube, which is located in the x-ray tubehead. X-rays are generated when electrons from the filament cross the tube and interact with the target. The two main components of the x-ray tube are the cathode and the anode.

Cathode Focusing cup Filament (tungsten) side view (cross-section) front view (facing target) The cathode is composed of a tungsten filament which is centered in a focusing cup. Electrons are produced by the filament (see next slide) and are focused on the target of the anode where the x-rays are produced. The focusing cup has a negative charge, like the electrons, and this helps direct the electrons to the target (“focuses” them; electrons can be focused, x-rays cannot).

Thermionic Emission When you depress the exposure button, electricity flows through the filament in the cathode, causing it to get hot. The hot filament then releases electrons which surround the filament (thermionic emission). The hotter the filament gets, the greater the number of electrons that are released. (Click to depress exposure button and heat filament). x-section of filament hot filament electrons

Electron Cloud

side view front view Anode Target Copper stem Target The anode in the x-ray tube is composed of a tungsten target embedded in a copper stem. When electrons from the filament enter the target and generate x-rays, a lot of heat is produced. The copper helps to take some of the heat away from the target so that it doesn’t get too hot.

X-ray Tube Components 1. focusing cup 6. copper stem 4 6 3 5 2 7 1 8 9 1. focusing cup 6. copper stem 2. filament 7. leaded glass 3. electron stream 8. x-rays 4. vacuum 9. beryllium window 5. target (for description, see next slide)

X-ray Tube Components (continued) 1. Focusing cup: focuses electrons on target 2. Filament: releases electrons when heated 3. Electron stream: electrons cross from filament to target during length of exposure 4. Vacuum: no air or gases inside x-ray tube that might interact with electrons crossing tube 5. Target: x-rays produced when electrons strike target 6. Copper stem: helps remove heat from target 7. Leaded glass: Keeps x-rays from exiting tube in wrong direction 8. X-rays produced in target are emitted in all directions 9. Beryllium window: this non-leaded glass allows x-rays to pass through. The PID would be located directly in line with this window.

Photo of an X-ray Tube Leaded glass Beryllium Window Target Photo of an X-ray Tube Leaded glass Beryllium Window Target Focusing cup (filament located inside)

X-ray Energy The energy of a wave of electromagnetic radiation represents the ability to penetrate an object. The higher the energy, the more easily the wave will pass through the object. The shorter the wavelength, the greater the energy will be and the higher the frequency, the greater the energy will be.

A B C Which of the above x-rays has the highest energy? A B C Which of the above x-rays has the highest energy? A: It has the shortest wavelength, highest frequency

The quality, or average energy, of the x-ray beam is increased with an increase in kVp or an increase in filtration. The quantity, or number of x-rays, is increased with an increase in time, mA setting and kVp setting. Quality Quantity kVp (primarily) mA no change Time no change Filtration Collimation does not change the energy or number of x-rays in the x-ray beam that reach the film; it just limits the size and shape of the beam.

Filtration Low-energy x-rays do not contribute to the formation of an x-ray image; all they do is expose the body to radiation. Therefore, we need to get rid of them. The process of removing these low-energy x-rays from the x-ray beam is known as filtration. Filtration increases the average energy (quality) of the x-ray beam. There are two components to x-ray filtration. The first of these, called inherent filtration, results from the materials present in the x-ray machine that the x-rays have to pass through. These include the beryllium window of the x-ray tube, the oil in the tubehead and the barrier material that keeps the oil from leaking out of the tubehead. This removes very weak x-rays.

Filtration (continued) The second component is the addition of aluminum disks placed in the path of the x-ray beam (added filtration). These disks remove the x-rays that had enough energy to get through the inherent filtration but are still not energetic enough to contribute to image formation. Disks of varying thicknesses, when combined with the inherent filtration, produce the total filtration for the x-ray machine. Federal regulations require that an x-ray machine capable of operating at 70 kVp or higher must have total filtration of 2.5 mm aluminum equivalent. (The inherent filtration is “equivalent” to a certain thickness of aluminum). X-ray machines operating below 70 kVp need to have a total filtration of 1.5 mm aluminum equivalent.

Filtration Total oil Added Inherent beryllium window barrier material Aluminum filter (s) Added Total beryllium window of x-ray tube Oil/Metal barrier Inherent beryllium window barrier material PID oil collimator filter

PID The filter is usually located in the end of the PID which attaches to the tubehead. filter

Collimation Collimation is used to restrict the area of the head that the x-rays will contact. We want to cover the entire film with the x-ray beam, but don’t want to overexpose the patient. Also, when x-rays from the tubehead interact with the tissues of the face, scatter radiation is produced (see below). This scatter radiation creates additional exposure of the patient and also decreases the quality of the x-ray image. (Scatter will be discussed in greater detail in the section on biological effects of x-rays). primary x-ray scattered x-ray

Collimation The collimator, located in the end of the PID where it attaches to the tubehead, is a lead disk with a hole in the middle (basically a lead washer). The size of the hole determines the ultimate size of the x-ray beam. The shape of the hole will determine the shape of the x-ray beam. You are looking up through the PID at the collimator (red arrows), which is a circular lead washer with a circular cutout in the middle. This will produce a round x-ray beam. The light gray area in the center is the aluminum filter

Collimation The shape of the opening in the collimator determines the shape of the x-ray beam. The size of the opening determines the size of the beam at the end of the PID. PID’s come in varying lengths; longer PID’s have a smaller opening in the collimator. round rectangular

Collimation The x-ray beam continues to spread out as you get further from the x-ray source (target). More surface is exposed on the exit side of the patient than the entrance side. By collimating the beam, less overall surface is exposed and as a result, less scatter radiation is produced. Both of these things reduce patient exposure. 2.75 inches (7 cm) is the maximum diameter of a circular beam or the maximum length of the long side of a rectangular beam at the end of the PID. collimated beam collimator target (x-ray source)

Collimation 7 cm 6 cm 7 cm round If you switch from a 7 cm round PID to a 6 cm round PID, the patient receives 25% less radiation because the area covered by the beam is reduced by 25%. Rectangular collimation (dotted line at left) results in the patient receiving 55 % less radiation when compared to what they would receive with a 7 cm round PID. 6 cm round film (4.5 cm long) entrance entrance exit exit area covered at skin surface (6 cm round PID) area covered as beam exits (6 cm round PID) area covered at skin surface (7 cm round PID) area covered as beam exits (7 cm round PID)

X-ray Beam Modifiers The following slides identify the various ways of changing the energy of the x-ray beam and the number of x-rays produced during an x-ray exposure.

Exposure Factors The energy of the x-ray beam and the number of x-rays are primarily regulated by the kVp control, the mA setting and the exposure time. One, two or all three of these exposure factors may need to be adjusted, depending on the size of the patient’s head, the likelihood of patient movement due to tremors or the inability to hold still, etc.. If the exposure factors are not set properly for the current patient, the resultant film may be too light or too dark (see next slide).

Exposure factors too high (too dark) Correct exposure factors Exposure factors too low (too light)

In the following situations, would you expect the x-ray film to be (A), overexposed, (B) correctly exposed or (C) underexposed? (No change in patient size). Recommended kVp, mA, exposure time (e.t.) Increase mA; no change in kVp, e.t. Decrease e.t.; no change in kVp, mA Increase kVp; no change in mA, e.t. Double mA, halve e.t.; no change in kVp B A C A B A B C overexposed correct exposure underexposed