Heavy Scintillating Glasses for Future High Energy Particle Physics Experiments Chun Jiang School of Electronic Information and Electrical Engineering.

Slides:



Advertisements
Similar presentations
Experimental Particle Physics
Advertisements

Silvia Franchino Universita' Pavia IFAE09 Bari - 15/04/09 1 Nuovi cristalli per la calorimetria a doppio readout DREAM collaboration (INFN Italy & US)
High Resolution Hadron Calorimetry with Dual Readout Adam Para, Fermilab Trends in Photon Detectors, Trieste, June 3, 2008.
1 Proton detection with the R3B calorimeter, two layer solution IEM-CSIC sept report MINISTERIO DE EDUCACIÓN Y CIENCIA CONSEJO SUPERIOR DE INVESTIGACIONES.
HEP Experiments Detectors and their Technologies Sascha Marc Schmeling CERN.
11 Components of Optical Instruments Lecture Spectroscopic methods are based on either: 1. Absorption 2. Emission 3. Scattering.
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
DREAM Collaboration: Recent Results on Dual Readout Calorimetry. F.Lacava for the DREAM Collaboration Cagliari – Cosenza – Iowa State – Pavia – Pisa –
Dense Scintillating Crystals and Glasses for HEP Dual Readout Calorimeter Tianchi Zhao University of Washington Dec. 4, 2007 Dual Readout Calorimeter Biweekly.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
Fiberless Coupled Tiles for a High Granularity Scintillator-SiPM Calorimeter Rick Salcido Northern Illinois University November 14, 2009 Prairie Section.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
New Calorimeter Technologies for NLC (a) Secondary Emission Calorimeter Sensors (b) Cerenkov Compensated Precision Calorimetry Y.Onel, University of Iowa.
Scintillators.
1 EMCal design MICE collaboration meeting Fermilab Rikard Sandström.
ZEUS Calorimeter (1) At HERA high energetic electrons (e) collide with high energetic protons (P). The ZEUS detector measures the properties of the particles.
Calorimeters A User’s Guide Elizabeth Dusinberre, Matthew Norman, Sean Simon October 28, 2006.
Liquid Helium Scintillation T. Wijnands EN/HDO Candidate for detecting beam losses in the LHC ?
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Proposal for IHEP participation in CBM ECAL
PPARC forum on developments in scintillator technology R M Brown - RAL 1 Scintillating Crystals for Particle Physics Outline  Performance considerations.
Heavy Scitillating Crystals and Glasses for a Combined EM and HCal at ILC Tianchi Zhao University of Washigton Sept. 25, 2007.
1 Scintillators  One of the most widely used particle detection techniques Ionization -> Excitation -> Photons -> Electronic conversion -> Amplification.
ALCPG October 25 th 2007 Hans Wenzel Calorimetry in slic How-to Motivation for dual readout Calorimeter What are our requirements Why did we choose SLIC.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics.
Heavy Scintillating Crystal Fibers for calorimetry
Shower Containment and the Size of a Test Calorimeter Adam Para, September 6, 2006.
Study of Sampling Fractions Shin-Shan Yu, A P, Hans Wenzel, October 18, 2006.
SiD R&D on PFA and Calorimetry -> IDAG guidance. -> Present PFA situation. -> Developing a timeline for PFA development. -> Calorimetry aspects.
서준석, KPS, R&D of Extruded Plastic Scintillator 서 준석 김 동희, 양 유철, 오 영도, 장 성현, 조 기현, KHAN Adil, MIAN Shabeer Ahmad ( 경북대학교 )
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
Experimental Particle Physics PHYS6011 Joel Goldstein, RAL 1.Introduction & Accelerators 2.Particle Interactions and Detectors (2/2) 3.Collider Experiments.
Tungsten as HCal-material for a LC at multi-TeV energies CALICE AHCAL Meeting, DESY 17 July 2009 Christian Grefe for the Linear Collider Detector Group.
Scintillation Detectors
Report from ILC detector working group Tao Hu Institute of High Energy Physics.
Coil and HCAL Parameters for CLIC Solenoid and Hadron-calorimetry for a high energy LC Detector 15. December LAPP Christian Grefe CERN.
The Case for the Dual Readout Calorimetry for SiD Adam Para, December 4, 2007.
E. A. Albayrak, HCAL Meeting, Fermilab, Nov HE CALORIMETER DETECTOR UPGRADE R&D STATUS E. A. Albayrak for The University Of Iowa Fairfield University.
ILC Calorimetry Test Beam Status Lei Xia ANL HEP.
Photon Detector with PbWO 4 Crystals and APD Readout APS “April” Meeting in Denver, CO on May 4, 2004 presented by Kenta Shigaki (Hiroshima University,
DESY Beam Test of a EM Calorimeter Prototype with Extruded Strip Scintillator DongHee Kim Kyungpook National University Daegu, South Korea.
Adam Para, Fermilab, February 16, Who Cares? What is the Problem? 2 Dual Readout Total Absorption calorimeter has very good energy resolution.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
NUMI NUMI/MINOS Status J. Musser for the MINOS Collatoration 2002 FNAL Users Meeting.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
W Prototype Simulations Linear Collider Physics & Detector Meeting December 15, 2009 Christian Grefe CERN, Bonn University.
WP 22 – SciFi Development and Characterisation of Inorganic Scintillating Fibers Made of LuAG:Ce and LYSO:Ce S. Diehl 1, R. Novotny 1, Aubry Nicolas 2.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
Part II: Calorimeter Technologies
J. Musser for the MINOS Collatoration 2002 FNAL Users Meeting
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
An Innovative Approach to Compact Calorimetry in Space, NEUCAL
Recent DHCAL Developments
Calorimeters at CBM A. Ivashkin INR, Moscow.
Where are we? What do we want to do next? Some thoughts
Irina Bavykina, MPI f. Physik
PAN-2013: Radiation detectors
Studies on Heavy Scintillating Glasses
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Calorimeters in HEP Add hermiticity CC event - calibration
Alternative CEPC Calorimeter
Comments on Linear Collider Calorimetry Case for Precision ECAL?
Experimental Particle Physics
Study of electron/hadron discrimination with the NEUCAL detector
Reports for highly granular hadron calorimeter using software compensation techniques Bing Liu SJTU February 25, 2019.
Experimental Particle Physics
Presentation transcript:

Heavy Scintillating Glasses for Future High Energy Particle Physics Experiments Chun Jiang School of Electronic Information and Electrical Engineering Shanghai Jiao Tong University Tianchi Zhao University of Washigton Nov. 6, 2007

Prototype Stack 30 x 30 cm steel absorber plates, 2 cm thick for a 1 cm gap between steel plates CALICE Analog Hadron Calorimeter for ILC Active detector: Plastic scintillator tiles 5 cm x 5 cm, 0.5 cm thick Light collected by Wavelength Shifting Fibers Readout by Silicon photomultipliers Average density of the CALICE analog calorimeter is ~5.5 g/cm 3

Hadron Calorimeter MPPC GLD Calorimeter Design Examples Electromagnetic Calorimeter Tungsten, lead or steel absorber plates plastic scintillator tiles or strips

Our Proposal To replace the structure of metal and plastic scintilaltor plates by scintillating glass blocks that glued together to form homogeneous modules. It will be - A total absorption calorimeter for optimum resolution - Can combine the functions of EM and Hadron Colorimeters A total absorption hadron calorimeter can have excellent energy resolution because it provide several ways to measure energies required to break up nuclei, which is mostly “invisible” in a sampling hadron calorimeter since such energy is mostly absorbed by the inactive metal plates.

Two Options Option 1: A conventional scintillation calorimeter that reads the scintillation light only Hadron energy that is invisible in a sampling calorimeter can be recovered by observing ionization energies from heavy nuclei fragments, spallation protons,  ’s released by fast neutron inelastic scatterings and recoiling nuclei due to fast neutron elastic scatterings, and energies released by thermalized neutrons captured by the calorimeter media Option 2: A dual readout calorimeter that reads the scintillation light and cherenkov light separately. Compensation for the invisible energy can be achieved by this method. See the reference Id=45&confId=1556

Excellent Hadron Energy Resolution Fluka Study by A. Ferrari and P.R. Sala of INFN-Milan for a total absorption calorimeter with four different materials presented in calor2000 Integration time Energy resolution A total absorption hadron calorimeters can potentially achieve excellent energy resolution for both EM and hadron showers Note: It is important to choose the right calorimeter media so that fast neutrons can be absorbed quickly (< ~1  s) and locally and contribute to the energy measurements

Calorimeter Technologies for HEP Historically, only electromagnetic calorimeters are total absorption calorimeters for high energy physics experiments. Hadron calorimeters are sampling calorimeters made of heavy metal absorber plates and active detector layers with very small energy sampling ratio (typically <<10%) A total absorption calorimeter was proposal for the D-zero detector at Fermi National Lab based on scintillating glass bars in the 1980’s. But that proposal was not adopted. Developing an appropriate scintillation material is the key for a total absorption calorimeter to become reality

Basic Requirements Calorimeter total volume : on the order of 100 m 3 High density Short radiation length Short interaction length Scintillation light properties compatible with the readout method ATLAS hadron calorimeterCMS hadron calorimeter

Scintillating Glasses as a Calorimeter Media for High Energy Physics Scintillating glass is inexpensive compared to crystal scintillators Light yield is normally less than 1% of NaI light yield of scintillating glass can be several times higher than the light yield of PbWO 4 crystal used by CMS experiment

Scintillating Glasses SCG1-C Scintillating glass: SCG1-C with modest density was developed in early 1980’s by Ohara Optical Glass Company in Japan Major components: BaO 44% and SiO 2 42% with 1.5% Ce 2 O 3 It is easy to fabricated and have good scintillation properties SCG1-C glass was considered for the EM and hadron calorimeter of the D-zero experiment at Fermilab in the 1980’s, but was not adopted SCG1-C was used in several HEP experiments as EM calorimeters Density 3.5 g/cm 3 is too low for our purpose No thermal neutron isotopes, not good for hadron calorimeters

Fluorohafnate Scintillating Glasses Attempts were made to develop Fluorohafnate Scintillating Glasses for CMS EM calorimeter by CERN’s Crystal Clear Collaboration in the 1990’s (HfF 4 -BaF 2 -CeF 3 ) + (5% Ce 2 O 3 doping) Density is quite high 5.95 g/cm 3 Low scintillation light yield ~0.5% NaI in near UV region Expensive and very difficult to make into sufficiently large size No thermal neutron isotopes, not good for hadron calorimeters Not good for our purpose

B 2 O 3 -SiO 2 -Gd 2 O 3 -BaO 30:25:30:15 doped with Ce 2 O 3 or other dopants Chun JiangChun Jiang, QingJi Zeng, Fuxi Gan, Scintillation luminescence of cerium-doped borosilicate glass containing rare-earth oxide, Proceedings of SPIE, Volume 4141, November 2000, pp QingJi ZengFuxi Gan Density 5.4 g/cm 3 is sufficient for an ILC calorimeter Contains a large amount of thermal neutron isotopes boron and gadolinium Will capture thermalized neutrons in a short time and in close proximity to hadron showers providing a mean for recovering invisible energies in hadron showers Our Proposed BSGB Scintillating Glass

BSGB Glass Density g/cm 3 Light yield ~500  ’s/MeV (?) Decay time ns Scintillation wavelength460 nm Radiation length1.8 cm Interaction length cm (estimate) Some Properties of the BSGB Glass

14 Transmission Spectrum of GSGB Glass A: Base glass without doping B: GSGB glass with 5%Ce C: After radiation

15 Fluorescence Spectrum of GSGB:Ce Glass

16 BSGB Glass Scintillation Light Yield (80 keV X-ray excitation)

17 Manufacturing Issues of Gadolinium Oxide Glasses 1. Conventional melting method with resistance furnace, reduction agents or reduction gases 2. Cost: Gd 2 O 3 is more expensive than PbO, Bi 2 O 3, Ce 2 O 3, La 2 O 3, etc, but cheaper than Yb 2 O 3, Lu 2 O 3, Ga 2 O 3, GeO 2, TeO 2, etc. 3. Large block of Gd 2 O 3 based scintillation glass with density of over 5.0g/cm 3 can be fabricated.

18 Future Plans (1) Make samples for testing by Fermilab (Dr. A. Para), University of Washington and Italian groups 5 cm x 5 cm and 10 cm x 10 cm, 1 cm to 2 cm thick If successful, supply ~ 20 liters of glass blocks for a EM calorimeter module to be tested in the beam at Fermilab

19 Future Plan (2) Scintillating Glass for a Dual Readout Calorimeter Investigate different doping for BSGB glass - The Ce +3 doping is used to general fast short wavelength scintillation light that is not necessary for an ILC calorimeter. - Ce +3 doping must be made in a reducing atmosphere and is difficult to control - Longer and slower scintillation light is required for a dual readout caloriemter For dual read design (readout scintillation and Cherenkov light separately), the scintillating glass must have Scintillation light spectrum peak > ~500 nm and/or Scintillation light decay time > ~100 ns

20 Future Plans (3) Investigate PbO-Bi 2 O 3 scintillating glass with high density of over g/cm 3 and high transmission at shorter wavelength.

21 The BSGB scintillating glasses with Ce 2 O 3 is an excellent candidates for total absorption calorimeters for colliders at very high energies that can achieve good EM and hadron energy resolution Further studies are necessary to make samples for testing BSGB scintillating glass with different doping with improved properties and suitable for the dual readout calorimeter can be developed Conclusions