A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, 21-24 Sept. 1999 Eleventh.

Slides:



Advertisements
Similar presentations
Ramesh Gupta, BNL D1 Dipole Design / IR Magnet Study LARP Collaboration Meeting, Oct 5-6, D1 Dipole Design Task (terminated in 2005) IR Magnet Study.
Advertisements

Field measurements of QEA magnets at KEK Mika Masuzawa May 30, 2006.
Laser Design Review, CERN, 27 Jan 2003Børge Svane Nielsen, NBI1 TPC Laser system  Functions of the system  Basics of the design  Construction tolerances.
Motors and Automatic Target Recognition Motors... l Motorized Instruments have 2 Motors: –One to Rotate the Alidade Horizontally –A Second to Rotate.
MICE- AFC Unit Mechanical Design of the Cold Mass Support System Oxford University Rohan Senanayake.
PXIE: SSR1 Section Focusing Lens 1.Requirements table 2.Developed at FNAL 3.Available from vendors 4.Used at ANL 5.Layout of the SSR1 cryomodule 6.Case.
Magnet Measurement Device for MICE F. Garnier, P-A. Giudici, F.Bergsma CERN MICE Collaboration Meeting No July 2011 Oxford technical drawings by.
Zachary Wolf Undulator Tuning June 17, 2008 Undulator Tuning Status Z. Wolf, S. Anderson, R. Colon, S. Jansson, S.Kaplunenko,
Enhancement of Single Stretched Wire Measurements of LHC Short Straight Sections Guy Deferne, Nikolay Smirnov, CERN Joe DiMarco, FNAL 14th International.
Coil Manufacture, Assembly and Magnetic Calibration Facility for Warm and Cold Magnetic Measurements of LHC Superconducting Magnets CERN AT-MTM 1 / 21.
Boring MEEG 217 Suraj Pandey. Introduction One of the most versatile machine tools; used to bore holes in large and heavy parts as engine frames, machine.
DELTA Quadrant Tuning Y. Levashov, E. Reese. 2 Tolerances for prototype quadrant tuning Magnet center deviations from a nominal center line < ± 50  m.
19 Nov 08,ILC08Cherrill Spencer Rotating Coil System Description 1 Short description of the SLAC rotating coil system used to measure the CIEMAT-made prototype.
1 / 19 M. Gateau CERN – Geneva – CH 14th International Magnetic Measurement Workshop September 2005, Geneva, Switzerland.
Rotating Coils - Giordana Severino – Rotating Coils PACMAN meeting Printed Circuit Coils – Future developments.
S. Russenschuck, CLIC-Workshop, WP2-Pacman, R&D projects on rotating coil probe and stretched wire techniques for CLIC / PACMAN Stephan Russenschuck.
US CMS DOE/NSF Review: May 8-10, Endcap Alignment Dick Loveless DOE/NSF Review 9 May 2001.
1 / 17 Author CERN – Geneva – CH 14th International Magnetic Measurement Workshop September 2005, Geneva, Switzerland Title.
MCAO Adaptive Optics Module Mechanical Design Eric James.
MARS 2 Design Review-Optomechanical Review 07 Nov 2002 GLW1 MARS 2 Mechanical Design Review.
1 LHC IR Quadrupole Alignment Experience at Fermilab T. Beale, J. DiMarco, J. Nogiec, P. Schlabach, C. Sylvester, J. Tompkins, G. Velev 28 September 2005.
Author CERN – Geneva – CH Jacques.Dutour 14th International Magnetic Measurement Workshop September 2005, Geneva, Switzerland 1 / 16 MQW magnets:
OPTODYNE Argonne National Laboratory Applicazioni dell'interferometria laser ad alta risoluzione Applications of high-resolution laser interferometry Gianmarco.
SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo.
Tuning. Overview Basic Tuning Difference between commutation methods Use of digital filters Vertical axis – no brake Overview 2.
F. Garnier, P-A. Giudici, F.Bergsma CERN MICE Collaboration Meeting No. 28 Absorber Systems & MICE Magnets Session 6 October 2010 technical drawings by.
Magnet Measurement Device for MICE F. Garnier, P-A. Giudici, F.Bergsma CERN MICE Collaboration Meeting No. 29 RAL technical drawings by O.Jamet.
Bnl - fnal- lbnl - slac US LHC Accelerator Research Program A Quadrupole Design for Crab Cavity Optics Ramesh Gupta Brookhaven National Laboratory Upton,
1 BROOKHAVEN SCIENCE ASSOCIATES Storage Ring Commissioning Samuel Krinsky-Accelerator Physics Group Leader NSLS-II ASAC Meeting October 14-15, 2010.
MM planning for HiLumi-LHC L. Fiscarelli M. Buzio, O. Dunkel, T. Zickler 4 March 2015.
Oct 17, 2001SALT PFIS Preliminary Design Review1 Southern African Large Telescope Prime Focus Imaging Spectrograph Mechanical Mechanism Design Michael.
Control systems KON-C2004 Mechatronics Basics Tapio Lantela, Nov 5th, 2015.
The Stripping Foil Test Stand in the Linac4 Transfer Line
1 Magnetic measurements proposal of the FAIR magnets Magnetic Measurements of Super-FRS dipoles: budgets 1 Budget for dipoles ( ) document FAIR-SFRS-magnetic_measurement_EVM.xls.
SPS UA9 data taking run with LHC-type Goniometer 31/07/2015 – Collimation Upgrade Specification Meeting #60 Roberto Rossi Daniele Mirarchi, Stefano Redaelli,
CLIC Workshop th -17 th October 2008 Thomas Zickler AT/MCS/MNC 1 CLIC Main Linac Quadrupoles Preliminary design of a quadrupole for the stabilization.
The VIRGO Suspensions Control System Alberto Gennai The VIRGO Collaboration.
Magnetic Metrology of SOLEIL Synchrotron S.R. Multipoles IMMW 14, A. Madur Magnetic Metrology of SOLEIL Synchrotron Storage Ring Multipoles A. Dael, P.
Magnetic Measurement Systems for the LHC Dipole Assembly Companies A. Rijllart, J. Billan, J. Garcia-Perez, D. Giloteaux, A. Raimondo, V. Remondino, H.
CLIC Stabilisation Day’08 18 th March 2008 Thomas Zickler AT/MCS/MNC/tz 1 CLIC Quadrupoles Th. Zickler CERN.
Magnetic Field Stability Measurements Joe DiMarco 23Oct07.
Presentation 7/05/2015 Giordana Severino ESR2.2, WP2 CERN Supervisors Marco Buzio Academic supervisor Prof. Pasquale Arpaia.
SL/BI 16/05/1999DIPAC’99 -- JJ Gras -- CERN SL/BI -- Adaptive Optics for the LEP 2 SR Monitors G. Burtin, R.J. Colchester, G. Ferioli, J.J. Gras, R. Jung,
Beam-beam Simulation at eRHIC Yue Hao Collider-Accelerator Department Brookhaven National Laboratory July 29, 2010 EIC Meeting at The Catholic University.
Warm-Cold Changes in the Sextupole Harmonic in the Quadrupole Magnets for the BEPC-II Luminosity Upgrade Animesh Jain Brookhaven National Laboratory Upton,
Measurement of LHC Superconducting Dipole and Quadrupole Magnets in Ramp Rate Conditions G.Deferne, CERN Aknowledgements: M. Di Castro, S. Sanfilippo,
Ladder Mount R&D T. Tsuboyama (KEK) 2 Oct T. Tsuboyama (KEK) 2 Oct
1 Magnetic measurements of the Super-FRS magnets 1 Overview: - Measurement systems for dipoles - requirements - Measurement systems review - Open points.
CERN –GSI/CEA MM preparation meeting, Magnetic Measurements WP.
Expected field quality in LHC magnets E. Todesco AT-MAS With contributions of S. Fartoukh, M. Giovannozzi, A. Lombardi, F. Schmidt (beam dynamics) N. Catalan-Lasheras,
Midterm Review 28-29/05/2015 Progress on wire-based accelerating structure alignment Natalia Galindo Munoz RF-structure development meeting 13/04/2016.
Integrated Hands-On Mechanical System Laboratories Arif Sirinterlikci, Ph.D., Professor of Engineering Tony Kerzmann, Ph.D., Assistant Professor of Mechanical.
Rotating Coil Measurement Errors* Animesh Jain Superconducting Magnet Division Brookhaven National Laboratory, Upton, NY 11973, USA 2 nd Workshop on Beam.
1 / 1 IMMW August 2007, Fermilab, Batavia, IL, USA CNAO R. Chritin CERN - Geneva Curved fluxmeter for static and dynamic characterization of pulsed.
Sardana/IcePAP Based Control System for elliptically polarized Undulator at Max IV 30th Tango Collaboration meeting
Wenjie Yang, Shaofei Han, Jing Yang
24/11/2017 Performance of the room temperature Systems for Magnetic Measurements of the LHC Superconducting Magnets at CERN J. Garcia-Perez, J. Billan,
Tutorial On Fiducialization Of Accelerator Magnets And Undulators
NEW UPGRADE TO THE APS MAGNETIC FIELD INTEGRAL MEASUREMENT SYSTEM
ALIGNMENT OF THE NEW TRIPLETS
Mechanical Design Review February 25, 2008 Université de Montréal
Procurement, Measurement and Installation of 2 Octupoles for ATF
UNIT-I SLOTTING MACHINES
Mechanical Design Review February 25, 2008 Université de Montréal
Recent developments on micro-triangulation
Geometric and Magnetic Measurements
POWER TRANSMISSION with BELTS & CHAINS
Towards a common mechanical interface
Brookhaven National Laboratory Upton, New York , USA
Magnetic measurements at ambient temperature on the MQXFBP1
Presentation transcript:

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Eleventh International Magnet Measurement Workshop September , 1999 Brookhaven National Laboratory, Upton, New York, USA A Mole for warm magnetic and optical measurements of LHC dipoles 1 Thursday, 23 Sept.1999 Berkner B 10:50-11:20 L Bottura 1, M Buzio 1, G Deferne 1, H Jansen 2, C Glöckner 2, A Köster 2, P Legrand 1, A Rijllart 1, P Sievers 1, F Villar 1 1 CERN, European Organization for Nuclear Research Geneva 23, Switzerland 2 Frauenhofer Institut IPT, Aachen, Germany 1 Also published in the proceedings of the 16 th International Conference on Magnet Technology, Ponte Vedra Beach, IL, 26 Sept- 2 Oct 1999

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept  Introduction  Mechanical layout  VR Demo 1  Magnetic performance  Optical performance  Conclusions A Mole for Warm Magnetic and Optical Measurements of LHC Dipoles 1

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Introduction  Why use a mole ?  Why use a mole ?  Purpose: measure magnetic axis  Cold measurements done for max. efficiency with 15 m long coil shaft, obstructing line-of-sight to the coil center  travelling probe is needed  Additional duties: warm field quality of all dipoles, cold field of samples  Requirements for series measurements  Requirements for series measurements  Coil center position: precision better than 0.1 mm  Warm measurements:  50 mm, B  25mT  Rugged, quick and simple to setup and operate  As many off-the-shelf components as possible

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Mole test bench overview rear reference bench (transport motor, cable connections) magnet front reference bench (telescope)

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Front reference bench CCD camera Telescope mole support shell (closed) Sliding support focusing system

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Rear reference bench Transport motor Cable receptacle Axis transfer jig Mole

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Front reference bench Laser for alignment measurement optical alignment targets (  4) axis transfer carbon fiber jig Telescope/CCD/DSP unit transport belt granite table

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Status  Warm Mole  Warm Mole  First unit accepted and under commissioning  Two more units to come, will perform warm test of all LHC dipoles  Can be readily adapted to warm quadrupole tests  Cold Mole  Cold Mole  Order started, last design details now being finalized  Will perform cold tests for a sample populations of LHC dipoles to get warm-cold axis correlation  Further units may be slightly modified for cold quadrupole tests

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Mechanical layout  Main features  Main features  three  mm  long radial coils  coil drive: Shinsei travelling-wave ultrasonic piezo motor  4096 CPR Heidenhein angular encoder  On-board feedback auto-leveling system  Spring-loaded roller system  Motorized traction belt drive  Two granite benches to establish reference positions  LED+lens system to create virtual light-spot in the coil centre  Telescope + CCD camera + DSP to measure light-spot position  All functions remotely controlled via RS232  Auxiliary optical system to transfer axis to magnet fiducials

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Main components Coil Elastic coupling (with helical groove for the cable) Ball-bearing support flange Piezo motor Wyler encoder Potentiometer 3:1 reduction gearbox

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Longitudinal transport  closed-loop pre-tensioned Inconel transport belt  feedback-controlled DC motor drive  referencing given by optical barriers at both ends of the magnet (self- calibration at the end of each trip)  max. velocity about 1 m/s  precision of positioning better than 0.5 mm  mole must be switched manually between apertures

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Longitudinal reference position lower half-shell support Optical barrier (receptor) spring-loaded roller LED viewing aperture front transport belt attachment

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Safety  interlock system: mole will stop if covers are removed, transport cable gets tangled, transport motor drains overcurrent  reduced velocity close to the edges  longitudinal position cross-checked with two independent measurements (angular encoder + linear potentiometer)

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Autoleveling  Why autoleveling ?  Why autoleveling ?  imperfections of beam pipe/rollers  rotation of container during travel  observed rotation up to 2~3°/m  transport belt & cable may be twisted  coil must be level prior to measurement  How does it work ?  DC motor engaged in container to rotate coil+encoder+piezo motor  feedback system using wide-range level meter  precision achieved better than 4 mrad  time needed less than 5 s  autoleveling done at the end of each longitudinal movement

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Auto-leveling mechanism Motor shaft gear Wide-range level meter Roller (fixed tangentially by friction) Inner gear (linked with container)

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Auto-leveling mechanism Final configuration Start End of travelling travelautolevel

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Optical measurement  Telescope  Telescope  accurately leveled and aligned wrt magnet  mounted on rails to serve both apertures  CCD camera  CCD camera  752  pixel, 6.00  mm size  self-aligned to telescope via reference marks  DSP image processor  DSP image processor  threshold filtering + center of gravity calculation  measurements internally averaged over multiple takes  software calibration map

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Virtual lightspot LED the virtual image remains in the coil center even when the mole rotates Magnifying lens

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Optical measurement  Performance  Performance   mm  mm  20 m range  total error  60  m  measurement time  4 s at closest range

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Optical system calibration

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Optical system calibration

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Example: optical measurement

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Focusing system  How does it work  How does it work  no autofocus needed  longitudinal position sent to the camera at the end of each movement  focusing motor follows a software calibration table  total error if out-of-focus  1  m/mm

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Magnetic performance  Harmonic Coils  Harmonic Coils   mm fiberglass/epoxy coil support  3 radial coils with 400 turns, 3.4 m 2 area  1 coil for main dipole, 1 for dipole compensation + 1 spare  System precision  System precision  Main dipole: better than  Dipole angle: better than 0.2 mrad  Multipoles: generally better than 2·10 -6 relative to B 1  bucking factor  2000

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Example: multipoles

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Example: calibrated dipole angle

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Axis Transfer  Why transfer the magnetic axis ?  Why transfer the magnetic axis ?  harmonics, and hence magnetic axis, are measured in the coil reference frame  the center of the coil is measured in the telescope reference frame  the magnetic axis is needed in the reference frame of the magnet fiducials  How the transfer will be done  How the transfer will be done  the granite tables establish two reference positions per aperture, vertically and laterally reproducible within 20  m  reference positions are measured by the telescope  relative position of magnet fiducials and granite tables is measured by means of an auxiliary laser system  relative position of coil center wrt magnet fiducials can thus be computed

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Axis Transfer Telescope frame   Mole coil position along magnet Granite table jig     Granite table reference line Magnet fiducial line Granite jig reference line Auxiliary alignment laser beam

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Axis Transfer Telescope reference frame  Mole coil position Magnetic center (z)    Marble table jigs line Magnet fiducial line Marble table reference line  Y Z

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Problems encountered  Unsteady velocity of piezo-motor, getting worse with motor heating  Micro cables and connectors delicate and difficult to handle  Fine alignment of the lens  Image distortion due to thermal gradients in the magnet

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Piezo motor rotation speed  Rotation speed quality  Rotation speed quality  encoder detects low-frequency rotation speed oscillations up to  8%  oscillation amplitude gets larger as motor heats up  oscillations interfere with measured harmonics (errors in b 2 up to 0.5 units observed)  Improvements under way  Improvements under way  optimization of stiffness and damping of the coil/motor link to minimize response  fine tuning of motor speed map  (t) to minimize excitation  enhanced motor cooling  automatic off-line filtering of spurious harmonics

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Piezo motor rotation quality Backward run Forward run average

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Piezo motor rotation quality

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Piezo motor rotation quality

A mole for warm magnetic and optical measurements of LHC dipoles IMMW XI, Brookhaven National Laboratory, Sept Conclusions  Magnetic and optical performance generally exceeding specifications  Well suited for industrial-type test environment  Test bed for further technological improvements (piezo-motor, remote encoders, etc.)  Software integration under way  Minor improvements under way: smoother velocity control, better optics alignment