Homework 1 Interest - HVAC -Lighting -Electrical -Sustainability -Acoustics Concerns.

Slides:



Advertisements
Similar presentations
HEAT LOSS & HEAT GAIN HEAT FLOW. Heat flows from high temperature to low temperature There are 3 types/methods of heat flow/transfer: 1.Conduction- through.
Advertisements

HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Environmental Controls I/IG
Heating and Air Conditioning I
Chilled Beam Presentation
Psychrometric Chart Basics
Psychrometrics.
PSYCHOMETRICS INTRODUCTION INDEXES PSYCHOMETRIC CHART INTRODUCTION:
Agricultural Structures: Insulation and Heat Flow
Pump Affinity Laws. P. 100 of text – section 4: vary only speed of pump P. 100 of text – section 5: vary only diameter P. 106 of text – vary BOTH speed.
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Heat Loss and Gain Heat Loss and Gain
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
Animal Environment & Heat Flow BSE 2294 Animal Structures and Environments S. Christian Mariger Ph.D. & Susan W. Gay Ph.D.
Environmental Systems and Facilities Planning Doug Overhults University of Kentucky Biosystems & Agricultural Engineering University of Kentucky College.
Why we need to calculate heating load ?
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
Conditioning of Moist Air
Objectives Learn basics about AHUs Review thermodynamics - Solve thermodynamic problems and use properties in equations, tables and diagrams.
Ductless Heat Pumps Sizing Example
Important variables Water: Air: Conversion:
Announcements Midterm Project Prepare groups of 3 to 4 students You can submit the list at the end of next class Midterm Exam 03/09/10 - In class Exam:
Update on the SEEM Simulation Program Larry Palmiter and Ben Larson August 4, 2008 Ecotope Inc. Presented at Regional Technical Forum Portland, Oregon,
Objectives Define psychrometric quantities Continuation from previous class Draw psychrometric processes Relate psychometric variables to human comfort.
Class Objectives Stress the importance of HVAC
1)Does ECJ have a larger heating or cooling load? A.Heating B.Cooling.
A Trane Air Conditioning Clinic Psychrometry Air Conditioning Clinic TRG-TRC001-EN © American Standard Inc
Objectives Lean about energy transport by air Calculate Cooling and Heating loads Solve 1-D conduction Design whether condition Use knowledge of heat transfer.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
1) Why do we calculate heating and cooling loads? A)To estimate amount of energy used for heating and cooling by a building B)To size heating and cooling.
0 Load Calculation Manual Output : 1. Screen Outputs (Results, Pareto Chart, Hourly Estimation) 2. Optional Outputs (*CLTD.txt, *TETD.txt) 3.
Objectives Analyze processes in AHU and buildings.
Objectives Finish with Heat transfer Learn about Psychometrics Psychometric chart.
Objectives Heat exchangers Fluid mechanics (ducts and pitot tubes) Introduction to psychrometrics.
EXAMPLE EXERCISE CALCULATING HEAT LOSS & HEAT GAIN  Several exhibits in the class packet are necessary to understand the entries into the Heat Loss /
Objectives Describe psychrometric quantities Given any two psychrometric quantities, calculate any other quantity Use Tables A4 or psychrometric charts.
Announcements 1) Thursday 02/09 In class Midterm Exam - I will be in the classroom at 9:20 AM - Example and solution are posted on the course website 2)
Introduction to Energy Management. Lesson 4 Determining the Loads on the HVAC System.
Introduction to Energy Management. Week/Lesson 5 Psychrometrics: The Properties of Air.
Objectives Ventilation analysis with HOP Human exposure/IAQ Ventilation and energy.
Objectives Psychometrics Psychometrics of AHU.
Chapter 3.4 Notes Thermal Rates.  The amount of heat that is transferred per unit time is the heat flow rate  Equation for heat flow rate = heat / time.
Technical Seminar on Application and Technical Specification June 2016
SECTION 7 AIR CONDITIONING (COOLING) UNIT 35 COMFORT AND PSYCHROMETRICS.
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
RESIDENTIAL HVAC (HEAT LOSS & GAIN)
CONFIDENTIAL Technical Seminar on Application and Technical Specification 21 June 2016 Rezza Arif Bin Mustapa Kamal Senior Engineer Project And Application.
PSYCHOMETRICS INTRODUCTION INDEXES PSYCHOMETRIC CHART INTRODUCTION:  PSYCHOMETRICS IS THE STUDY OF MOIST AIR.  THE PSYCHOMETRIC CHART IS A GRAPHIC REPRESENTATION.
Psychrometric Chart Basics. Basic Concepts Saturation Line.
Heat Loss and Gain Heat Transfer Winter Heat Loss Summer Heat Gain
Conduction Cooling Loads
Introduction – Who am I? Environmental Project Manager – Trident Technical College Mechanical Engineer Licensed Builder South Carolina Accredited Commercial.
Chapter 13B: PSYCHROMETRIC MOIST AIR PROCESSES
Psychrometrics – Lecture 3
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Heat Loss and Gain
Why we need to calculate heating load ?
Heat Loss and Gain Civil Engineering and Architecture
Lecture Objectives Review what we learned about Eclectic Energy Production Learn about Thermal Comfort Introduce Psychrometric Chart.
Lecture Objectives Review: Psychrometrics (chart and quantities)
Lecture Objectives Learn about Psychrometric Chart Quantities
Lecture Objectives Psychrometrics Define Heating and Cooling Loads
Quiz First 10 minutes of the class.
Announcements Exam 1 Next Class (Thursday, March 14th):
Lecture Objectives Learn about Cooling Load Calculation
Objective Revie the Cooling Cycle Learn about air distribution systems
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Heat Loss and Gain
Presentation transcript:

Homework 1 Interest - HVAC -Lighting -Electrical -Sustainability -Acoustics Concerns

Objectives Review Psychrometrics Sensible and latent heat Define thermal comfort in Psychrometric chart Equations for energy transport by air Calculate heat loss and gain due to conduction Use knowledge of heat transfer to calculate heating and cooling loads

Which situation has highest RH? A)Summer day in Austin, TX B)Winter day in Aspen, CO C)The air downstream of a cooling coil D)Summer day in Seattle, WA

sensible latent Sensible vs. Latent Heat

Changing the mass of water in an air sample always A.Causes you to move vertically on the psychrometric chart B.Changes the absolute humidity of the sample C.Changes the relative humidity of the sample D.Causes you to move horizontally on the psychrometric chart E.A. and B.

Example Cooling with a oversized air conditioner How much moisture is removed? A central air conditioner fan blows 1500 CFM of 80 °F 50 % RH through a coil. The thermostat is satisfied when the air coming off the coil reaches 65 °F.

1993 ASHRAE Comfort Zone

1997/2001 ASHRAE Comfort Zone

If you know the dew point temperature (t d ) and the dry bulb temperature (t) for a sample of air A)You can’t get the statepoint because the problem is overspecified (you know the RH = 100%, t and t d ). B)You get the state point by the intersection of the t and t d lines. C)You get the state point by moving horizontally from t d until you intersect the t line D)You get the state point by moving vertically from t d until you intersect the t line

Examples: 1) You heat one pounds of air air A (T=50F, W=0.009 lb W /lb DA ) to point T=80F and humidify it to RH 70%. What is the sensible, latent and total heat added to the one pound of air. 2) One pound of air D(T=90F, RH=30%) is humidified by adiabatic humidifier to 90% relative humidity. What is the temperature at the end of humidification process and how much water is added to the air.

Psychrometric Chart 1.Make sure chart is appropriate for your environment 2.Figure out what two quantities you know 3.Understand their slopes on the chart 4.Find the intersection Watch for saturation

Use the psychrometric chart Pay attention to units in calculations Values for Δh and Δw per mass unit of dry air Differences in nomenclature Homework Assignment 2

Equations for sensible energy transport by air Energy per unit of mass Δh sensible = c p × ΔT [Btu/lb] c p - specific heat for air (for air 0.24 Btu/lb°F) Heat transfer (rate) Q s = m × c p × ΔT [Btu/h] m - mass flow rate [lb/min, lb/h], m = V ×  V – volume flow rate [ft 3 /min or CFM]  – air  density (0.076lb/ft 3 ) Q s = 1.1 × CFM × ΔT (only for IP unit system)

Equations for latent energy transport by air Energy per unit of mass Δh latent = Δw × h fg [Btu/lb da ] h fg - specific energy of water phase change (1000 Btu/lb w ) Heat transfer (rate) Q l = m × Δw × h fg [Btu/h] Q l = 1000 × WaterFloowRate (only for IP units)

Total energy transport calculation using enthalpies from chat Energy per unit of mass Δh=h 1 -h 2 [Btu/lb da ] Heat transfer (rate) Q total = m × Δh [Btu/h] Q total = Q sensible + Q latent

Why do we calculate heating and cooling loads? A)To estimate amount of energy used for heating and cooling by a building B)To size heating and cooling equipment for a building C)Because my supervisor request that Heating and Cooling Loads

Introduction to Heat Transfer Conduction Components Convection Air flows (sensible and latent) Radiation Solar gains (cooling only) Increased conduction (cooling only) Phase change Water vapor/steam Internal gains (cooling only) Sensible and latent

1-D Conduction Qheat transfer rate [W] k conductivity [W/(m °C)] l length [m] 90 °F 70 °F l k A U = k/l ΔTtemperature difference [°C] Asurface area [m 2 ] U U-Value [W/(m 2 °C)] Q = UAΔT

Material k Values Materialk [W/(m K)] 1 Steel Soil0.52 Wood Fiberglass Polystyrene At 300 K Table 2-3 Tao and Janis (k=λ) values in [Btu in/(h ft 2 F)]

90 °F 70 °F l1l1 k1k1 k2k2 l2l2 R = l/k Q = (A/R total )ΔT Add resistances in series Add U-values in parallel R1R1 R2R2 T out T in T mid Wall assembly

T out T in R1R1 R2R2 RoRo T out RiRi T in Surface Air Film h - convection coefficient - surface conductance [W/m 2, Btu/(h ft 2 )] Direction/orientation Air speed Table 2-5 Tao and Janis R total = ΣR i R surface = 1/h

l1l1 k 1, A 1 k 2, A 2 l2l2 l3l3 k 3, A 3 A 2 = A 1 What if more than one surface? Q3Q3 Q 1,2 Q total = Q 1,2 + Q 3 U 1,2 = 1/R 1,2 =1/(R 1 +R 2 ) Q 3 = A 3 U 3 ΔT Q 1,2 = A 1 U 1,2 ΔT

U 1 A 1 U 2 A 2 U 3 (A 3 +A 5 ) U 4 A 4 U 5 A 5 Q total = Σ(U i A i )·ΔT Relationship between temperature and heat loss A1A1 A5A5 A4A4 A3A3 A2A2 A6A6 T in T out

Which of the following statements about a material is true? A)A high U-value is a good insulator, and a high R-value is a good conductor. B)A high U-value is a good conductor, and a high R-value is a good insulator. C)A high U-value is a good insulator, and a high R-value is a good insulator. D)A high U-value is a good conductor, and a high R-value is a good conductor.

Example Consider a 1 ft × 1 ft × 1 ft box Two of the sides are 2” thick extruded expanded polystyrene foam The other four sides are 2” thick plywood The inside of the box needs to be maintained at 120 °F The air around the box is still and at 80 °F How much heating do you need?

The Moral of the Story 1.Calculate R-values for each series path 2.Convert them to U-values 3.Find the appropriate area for each U-value 4.Multiply U-value i by Area i 5.Sum UA i 6.Calculate Q = Σ(UA i )ΔT

Heat transfer in the building Not only conduction and convection !

Infiltration Air transport Sensible energy Previously defined Q = m × c p × ΔT [BTU/hr, W] ΔT= T indoor – T outdoor or Q = 1.1 BTU/(hr CFM °F) × V × ΔT [BTU/hr]

Latent Infiltration and Ventilation Can either track enthalpy and temperature and separate latent and sensible later: Q total = m × Δh[BTU/hr, W] Q latent = Q total - Q sensible = m × Δh - m × c p × ΔT Or, track humidity ratio: Q latent = m × Δw × h fg

Ventilation Example Supply 500 CFM of outside air to our classroom Outside 90 °F61% RH Inside 75 °F40% RH What is the latent load from ventilation? Q latent = m × h fg × Δw Q = ρ × V × h fg × Δw Q = lb air /ft 3 × 500 ft 3 /min × 1076 BTU/lb × ( lb H2O /lb air lb H2O /lb air ) × 60 min/hr Q = 26.3 kBTU/hr

What is the difference between ventilation and infiltration? A)Ventilation refers to the total amount of air entering a space, and infiltration refers only to air that unintentionally enters. B)Ventilation is intended air entry into a space. Infiltration is unintended air entry. C)Infiltration is uncontrolled ventilation.

Where do you get information about amount of ventilation required? ASHRAE Standard 62 Table 2 Hotly debated – many addenda and changes Tao and Janis Table 2.9A

Ground Contact Receives less attention: 3-D conduction problem Ground temperature is often much closer to indoor air temperature Use F- value for slab floor [BTU/(hr °F ft)] Note different units from U-value Multiply by slab edge length Add to ΣUA Still need to include basement wall area Tao and Janis Tables 2.10 and 2.11 More details in ASHRAE handbook -Chapter 29

Conclusions Conduction and convection principles can be used to calculate heat loss for individual components Convection principles used to account for infiltration and ventilation Readings: Tao and Janis