Korean Research Results “Fire resistance test” June 2, 2015 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute (KATRI)

Slides:



Advertisements
Similar presentations
Task Force 3: Electrolyte leakage Last update- 12/05/
Advertisements

Draft Deliberative Document1 of 15 Hydrogen Fuel Cell Vehicle Safety Research to Support Rulemaking/GTR Objectives September 2008 SGS
Lesson 17 HEAT GENERATION
Korea Research Results “Fire resistance test” Nov 17, 2014 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute (KATRI)
AN-NAJAH NATIONAL UNIVERSITY FACULTY OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING Prepared by: Wajdi abu-muhsen Khaled aamer Ahmad Al-Hunate Nabeel.
Proposal of Fire Resistance Test
MVFRI 1 Fire Safety of Hydrogen-Fueled Vehicles: System-Level Bonfire Test by R. Rhoads Stephenson Motor Vehicle Fire Research Institute
0 Copyright; 2007 IAE. All rights reserved. 2nd ICHS 11-13/9/2007 Spain Study of Hydrogen Diffusion and Deflagration in a Closed System Yuki Ishimoto 1,
EVS-GTR TF5 Update Progress TF5 task force – thermal propagation 2015/6/4.
Determination of Powertrain Performance of Hybrid Electric Vehicles Presented by: Germany, Korea EVE-15 meeting June 8, 2015.
Progress report of TFG 7 “Fire resistance test” June 5, 2015 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute (KATRI)
Progress report of TFG 7 “Fire resistance test” Mar 18, 2015 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute (KATRI)
Gas Furnace Planned Maintenance
Gas Turbine Power Plant
Progress Report, EVS SOC-TF May 2014 U.S. DOT Head Quarter 1200 New Jersey Avenue, SE Washington, DC
Transposition of GTR No.13 “Hydrogen and fuel cell vehicles” into UN Regulation - Explanatory material - 20/September/2013 The European Commission and.
Fire resistance tests at SP RESS-4-10 Rev.01. Three sets of tests were conducted –Mock-up chassi, varying fuel, pre-heating time, direct exposure time.
Korea opinion for “Fire resistance test” Sep. 15, 2015 Korea Transportation Safety Authority (TS) Korea Automobile Testing & Research Institute (KATRI)
Progress report of TFG 7 “Fire resistance test” May 14, 2014 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute (KATRI)
Transient Thermal Analysis Winter Semester
for Thermal Propagation
DEVELOPING FIRE TESTS FOR FCV AND HYDROGEN VEHICLES Glenn Scheffler Consultant for the US Department of Energy August 2010 DEVELOPING FIRE TESTS FOR FCV.
TF5 – Status report on thermal propagation EVS-GTR 9 th IWG meeting Changchun, China 2015/9/17.
Worldwide Harmonized Heavy Duty Emissions Certification Procedure UNITED NATIONS 57th GRPE, Geneva, 15 January 2009 Informal document No. GRPE (57th.
Experimental and numerical studies on the bonfire test of high- pressure hydrogen storage vessels Prof. Jinyang Zheng Institute of Process Equipment, Zhejiang.
Progress report of TFG 7 “Fire resistance test” Mar 19, 2015 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute (KATRI)
Background Numerous FAR’s mandate fire protection in aircraft powerplant fire zones Parts 23, 25, 27, 29, 33… FAR Part 1 Section 1.1 – Definitions and.
1 Discussion paper on Current Status on TF5 test items Xiao Chengwei.
Progress report of TFG 7 “Fire resistance test” (rev.1) Nov 19, 2014 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute.
GTR-EVS TF-6 SOC – OICA Discussion Paper Jan 21 st, OICA Discussion Paper for TF-Mtg1 EVSTF-06-32e.
OICA observation on venting The 7 th all TF F2F Meetings EVS in Tokyo JAPAN 1.
Progress report of TFG 7 “Fire resistance test” Mar. 3rd, 2016 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute.
Manoj kumar 2009JE0406 Mining machinery engineering.
EVS GTR – TF3 Presentation on EVSTF-07-12e "JRC proposal for a 60 minutes observation time for electrolyte leakage – post-crash" V. Ruiz, N. Lebedeva,
OICA TF8 drafting annex Mar. **, 2016 TF8 OICA pilot 1 EVSTF-08-25e.
Korea Automobile Testing & Research Institute Korea Transportation Safety Authority 1 1 정 혁 책임연구원 Korea Automobile Testing and Research Institute(KATRI)
Progress report of TFG 7 “Fire resistance test” Sep. 17th, 2015 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute.
Task Force 8: Heavy Duty Vehicles
Federal Aviation Administration COMPOSITE MATERIAL FIRE FIGHTING Presented to:International Aircraft Materials Fire Test Working Group Köln, Germany Presented.
10th EVS-gtr IWG Progress Report TF6 - SOC 2nd March
Electric Vehicles Safety Global Technical Regulation
Co-Sponsors: China, Japan, EU and US 59th Session GRSP May 9-13, 2016
Fire Study in Multiple Compartments
Status report / Activity Plan of Evap Task Force
Electric Vehicles and the Environment (EVE IWG)
Structural Fire Engineering, October 2015, Dubrovnik, Croatia
HOMOGENEOUS HYDROGEN DEFLAGRATIONS IN SMALL SCALE ENCLOSURE
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
‘Proposal of Fire resistance test’
The Candle Flame Measuring the temperature of a flame according to the “three zones model”
Japan research of thermal propagation test
JASIC Japan ______ 61st GRSP Session May 2017
Task Force Outline Submitted by an expert from the Republic of Korea
Korea Research Results “Fire resistance test”
Conditions and procedures of Japan research
“Fire resistance test”
Informal document GRE-79-04
Japan research of thermal propagation test
Proposal for amendment GTR No.6
The Analysis of Fire Test for the High Pressure Composite Cylinder
Korea Research Results “Fire resistance test”
EVS-06-10e Progress Report on TF5 Nov. 3rd, 2014.
Japan’s response to Action item 2 EVS-GTR IWG#17.
IWG-DPPS/4/04 Proposal for System Information Requirement with regard to Deployable Pedestrian Protection Systems 4th meeting, March 2019 OICA, Paris.
Chair: Jin Seop Park, Republic of Korea Secretary: Thomas Kinsky, OICA
8th all TF F2F Meetings EVS Washington DC
Dr. Hans Holdik Dongseok CHOI / Ph.D.
Informal document GRE-79-xx
TF1 Meeting content Open issues of EVS 10th meeting
Presentation transcript:

Korean Research Results “Fire resistance test” June 2, 2015 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute (KATRI) Seulki Lee Senior Researcher UN ECE / WP29 / GRSP/ 8 th EVS Informal Meeting in Washington D.C (4 th TFG-7 F2F Meeting) EVS TF-03-XXe

1 Part 1. Short Term Fire Resistance Test 1. Adopting test(A) with being optional or replacement of test(B) (~ 8 th EVS meeting) 2. Reviewing the GTR draft text proposed by Korea ☞ Korea will take members’ additional opinions by (~ 30 th April) ☞ Korea will review if the position of thermo has to be defined (~ 8 th EVS meeting) ☞ Korea will suggest the detailed description for temperature (~ 8th EVS meeting) 3. Investigating if test facilities exists that could conduct the test(A) ☞ Assistance needed from IWG secretary to ask contracting parties(~ 30 th April) 4. Submitting the GTR draft improved regarding to short term test (~ 8th EVS meeting) 5. Need to get US’s opinion on Korean proposal as short term (~ 8th EVS meeting) Open issues & Future work

2 Part 2. Long Term Fire Resistance Test 1. Basic issues of the fire resistance test such as purpose, definition of long term, exposure time, etc. 2. A long term fire resistance test ☞ US and Canada will suggest the detailed working plan and timeline with regard to long term test (~ 8th EVS meeting) Open issues & Future work

3 rd face to face meeting Proposed draft text on test(A) needs to be reviewed. - Authority to choose the test either test(A) or test(B) must to be defined in current GTR draft - Position of thermo sensors must be defined to make sure repeatability - Korea will review if and how thermo sensor location has to be defined - The necessity of upper limit 1100℃ must to be reviewed - Detailed description such as temperature profile is to be needed TF7 need to investigate for contracting parties if test facilities exists that could conduct the test(A) proposed by Korea. 3 Open issues & Future work

4 Structure (1)-OICA’s proposal Opinion of KATRI for EVS GTR draft proposal Structure (2)-KATRI’s opinion Purpose Installation Procedure General Condition Test procedure Vehicle based test Component based test Gasoline pool fire test LPG burner fire test Purpose General Condition Installation Procedure Vehicle based test Component based test Gasoline pool fire test LPG burner fire test General condition goes up to upper level The procedure of Gasoline and LPG test are included in a component test (In vehicle based test, such as “detailed test procedure shall be followed by component test” should be mentioned in

5 Opinion of KATRI for EVS GTR draft proposal Position of thermo sensors ① ② ③ ④ ⑤ ① ② ③ ④ ⑤ ① ② ③ ④ ⑤ ① ② ③ ④ ⑤ (×) (O)  Japan comment  Position of thermo sensors must be defined to make sure repeatability  KATRI Opinion  As a result of KATRI test, all the position of temperature satisfy the requirement, but temp. at the center is relatively lower than that of side  We can not assure that which 5 points represent the REESS due to indeterminate shape and size of REESS  So, without defining the position of thermo sensors, the 5 points can be determined with a common sense as described below Position of thermo sensors At least [5] temperature sensors which can represent whole area of the Tested-Device shall be installed 25mm±10mm from the bottom of the Tested-Device’s external surface along its longitudinal axis. Each temperature sensors should satisfy the temperature conditions.

6 Opinion of KATRI for EVS GTR draft proposal  Japan comment  The necessity of upper limit 1100℃ must to be reviewed  JARI research memo (EVS 7 th meeting in Paris)  JARI recommended to use LPG burner with not air pre-mixed LPG which can cause red flame (imcomplete combustion area) The necessity of upper limit 1100℃ Pre-mixture LPG flame LPG flame (not Pre-mixed) Red flame Blue flame Flame temperature Radiation High Low High Heat flux [W/m 2 ] Red flame  KATRI comment  We should make flame in the “Incomplete combustion area” which consist of sufficient LPG flow rate and low air rate  Yellow flame is not suitable for fire test due to low temperatuer.

Complete combustion(Blue flame)Incommplete combustion(Red flame) 1015℃662℃864℃678℃ 7 Opinion of KATRI for EVS GTR draft proposal  KATRI test  The shape & temperature of flame with different air rate condition in a single Bunsen burner  KATRI opinion  In case of LPG burner proposed by KATRI, the maximum temperature of flame can be higher than single Bunsen burner influenced by such as a radiation  Upper limit 1100 ℃ means not to reach complete combustion area  Need to regulate upper temperature

8 Opinion of KATRI for EVS GTR draft proposal  Vehicle based exposure temperature comparison test (EVS 7 th meeting in Paris) Review of vehicle based test using LPG burner Test configurations Test(A)-KMVSSTest(B)-GTR Draft Descriptions * DUT : PRIUS Body & REESS Case - Body : Remove the combustible material in body - REESS : Remove the battery cell and sub systems - DUT setting Height ㆍ TEST(A) : 31.5 cm (Nozzle to bottom of vehicle body) ㆍ TEST(A’) : Actual mounting condition ㆍ TEST(B) : Actual mounting condition * DAQ get 8 temp. channel - Measurement height : 25±10mm from the bottom of DUT’s external surface by the vertical direction - REESS Case : 4 points - Vehicle body: 4 points - K-Type Thermocouple : ∅1.6mm Temp. measuring 8 points ①② : Inside temp. (Case) ③④ : Bottom temp. (Case) ⑤ : Inside temp. (Body) ⑥⑦⑧ : Bottom temp (Body) ⑦ ⑧ ⑥ ① ② ③ ④ ⑤ Mar. 2015

9 Progress Report of KATRI Research Test Result MeasurementTEST(A)TEST(A’)TEST(B) Avg. Temp.(For 150 sec) (For 130 sec) - REESS Inside109 ℃64 ℃37 ℃ - REESS Bottom122 ℃66 ℃38 ℃ - Body inside141 ℃125 ℃35 ℃ - Body Bottom(High)693 ℃617 ℃570 ℃ - Body Bottom(Low)872 ℃813 ℃537 ℃ Max. Temp.976 ℃939 ℃887 ℃ Comment  The temperature of Test(A) is about 100℃ higher than the Test(A’)  The temperature of Test(B) is lower than others due to its small exposure area  The temperature of Test(A) around the bottom are irregular because the shape of vehicle’s body frame is not flat at the bottom  The temperature of vehicle bottom at the longitudinal position where REESS is mounted is 690 ℃ in Test(A), 620 ℃ in Test(A’), 570 ℃ in Test(B)

10 Opinion of KATRI for EVS GTR draft proposal  Vehicle based exposure temperature test Test configurations Test(A)-31.5cmTest(A’)-Actual mounting Descriptions * DUT : PRIUS Body & REESS Case - Body : Remove the combustible material in body - REESS : Remove the battery cell and sub systems - DUT setting Height ㆍ TEST(A) : 31.5 cm (Nozzle to bottom of vehicle body) ㆍ TEST(A’) : Actual mounting condition * DAQ get 6 temp. channel - Measurement height : 25±10mm from the bottom of DUT’s external surface by the vertical direction - REESS inside : 1 points - Vehicle body : 5 points(Bottom) - K-Type Thermocouple : ∅1.6mm ⑥ May ⑥ ①②③④⑤ ⑤ ④ ② ③ ① Temp. measuring 6 points 64 cm 31.5 cm Fire resource

11 Test Result KATRI Opinion  The average temperature of vehicle bottom at the longtitudinal position where REESS is mounted is 760 ℃ in Test(A) and 732 ℃  In the vehicle based test, it is difficult to meet the test requirement of temperature(800℃) and reaching time(30 sec.)  Most of REESS in HEV will be installed similar positioni to PRIUS, so similar result might be expected  To apply LPG burner to vehicle based test, it is necessary to adjust the temperature and vehicle height as the test requirement temperature : 800 ℃ → 600 ℃ height of vehicle installed : actual mounting condition → can be variable from actual mounting condition Test Result Temp. distribution - Total Avg. Temp. : ℃ ☞ REESS inside : ℃ (Ignition after 30 sec ~ Fuel cut) - Max. Temp. : ℃ ℃ reaching time : 30 sec Temp. distribution - Total Avg. Temp. : ℃ ☞ REESS inside : ℃ (Ignition after 30 sec ~ Fuel cut) - Max. Temp. : ℃ ℃ reaching time : 40 sec Opinion of KATRI for EVS GTR draft proposal

12 Opinion of KATRI for EVS GTR draft proposal  Purpose  The existing test-equipment has no problem for performing short duration fire test, but when operating for a long time continuously, it is a little difficult to keep same condition due to the latent heat of vaporization which can cause decrease of gas flow rate and temperature. To solve this problem, an improvement of LPG supply was necessary.  Solution  Installing a vaporizer(electric heated water type) so that the gas flow rate and the temperature could be kept constant. Improvement of LPG supply

1,000×1,000×200 mm, Floor area : 1 ㎡K-Type ∅1.6mm / 25±10mm from the bottom of DUT 13 Opinion of KATRI for EVS GTR draft proposal Performance test for improved LPG burner ① ② ③ ④ ⑤ ⑥  Purpose  To adjust the fire condition as we had improved the LPG supply  As the supplied gas temperature increase, the pressure of gas gets increase, and the shape of flame become bigger than before even the gas flow rate keeps same  Performance test  Confirm the optimum gas flow rate and height of Tested-Device installed

14  Test scene and result LPG mass flow rate Per 1 Burner module : 30 kg/h → 35 kg/h Total (5 Modules) : 150 kg/h → 175kg/h Supplied LPG Temp. : 0 ℃ → 35~45 ℃ Increase the pressure of LPG Test Result Opinion of KATRI for EVS GTR draft proposal Temp. distribution - Total avg. Temp. : 914 ℃ (Ignition after 30 sec ~ Fuel cut) - Max. Temp. : 1009 ℃ ℃ reaching time : 27 sec - Height of flame : about 60 cm - DUT setting Height : 40 cm (Nozzle to Bottom of DUT)

15 Test Result Opinion of KATRI for EVS GTR draft proposal Temp. distribution - Total Avg. Temp. : 914 ℃ (Ignition after 30 sec ~ Fuel cut) - Max. Temp. : 1009 ℃ - Height of flame : about 60 cm - DUT setting Height : 40 cm (Nozzle to Bottom of DUT) Temp. distribution - Total Avg. Temp. : 881 ℃ (Ignition after 30 sec ~ Fuel cut) - Max. Temp. : 955 ℃ - Height of flame : about 50 cm - DUT setting Height : 31.5 cm (Nozzle to Bottom of DUT)  Comparison BEFORE & AFTER improving LPG supply condition The entire scale of flame gets bigger due to increase of gas flow rate The average temperature gets increased about 70 ℃ through 5 points. The thermal energy of LPG type possibly gets closer to that of gasoline pool type The thermal energy per unit area of gasoline pool test is 16% higher than LPG burner test for the large mock-up condition(EVSTF-02-23e-Simulation result)

16 Investigation on test facilities CountryOrganizationpossessioncapabilityTest Facility US, Texas △ O Two different test setup 1.Utilize plate burner that introduce a propane air mixture : obtain 800℃ quickly 2.Manifold system that supplies propane to nozzles : around 1000℃ US, Texas △ OLPG pan burner CanadaCNRC.NRC △ O Propane Sand Burner Canada △ O TÜV SÜD has performed similar tests of approximately the same physical footprint. The proposed hardware is different and would require some development efforts Japan?? No facilities to perform the proposed test method. but have experienced tests with LPG burner (from JARI memo) Sweden △ O SP Technical Research Institute of Sweden could conduct test according to the proposed test method. China △ O To be Have a similar device, but not satisfy the requirement. The device is being improved by August.

Thank you!