Tutorial:Mechanic - electrician Topic:Basics of electrical engineering the 2nd. year Protection in electric networks Protection of inanimate parts Prepared.

Slides:



Advertisements
Similar presentations
Educational program: Mechanic – electrician Program title: Technical training II. class Correction amplifier Worked out: Bc. Chumchal Miroslav Projekt.
Advertisements

Training program: Mechanic - electrotechnician Program name: Digital processing - microprocessors III. class Microcontrollers Elaborated by: Vlastimil.
Educational program: Mechanic - electrician Title of program: Technical training II. class Monostable multivibrator Worked out: Bc. Chumchal Miroslav.
Training program: Mechanic - electrotechnician Program name: Digital processing - microprocessors III. class Microcontrollers Elaborated by: Vlastimil.
Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
imnot50 and suite4121 The form of protection provided by the insulation of live parts would be: Protection against direct contact.
Educational program: Mechanic - electrician Title of program: Technical training II. class The loudspeakers Worked out: Bc. Chumchal Miroslav Projekt.
Tutorial: Mechanic - electrician Topic: Basics of electrical engineering the 2nd. year Measuring system 2 Prepared by: Ing. Jiří Smílek Projekt Anglicky.
Tutorial: Engineering technology Topic: Casting – basic definitions Prepared by: Ing. Elena Nová Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Educational program: Mechanic - electrician Title of program: Technical training II. class Oscillators Worked out: Bc. Chumchal Miroslav Projekt Anglicky.
Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Tutorial: Mechanic - electrician Topic: Technical training II. class Printed circuit boards 1 Prepared by: Melichařík Lubomír Projekt Anglicky v odborných.
Tutorial: Engineering technology Topic: Pressed and plunger connections Prepared by: Ing. Elena Nová Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Tutorial: Mechanic – electrician Topic: Electronics II. class RC Filters: RC High Pass Filter Prepared by: Ing. Jaroslav Bernkopf AVOP-ELEKTRO-Ber-008.
Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Tutorial: Mechanic - electrician Topic: Technical training II. class Passive components – condenser Prepared by: Melichařík Lubomír Projekt Anglicky v.
Tutorial: Mechanic - electrician Topic: Technical training II. class Semiconductor devices 2 Prepared by: Melichařík Lubomír Projekt Anglicky v odborných.
Tutorial: Engineering technology Topic: Roller bearings Prepared by: Ing. Jaroslav Hábl Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Educational program: Mechanic - electrician Title of program: Technical training II. class The loudspeaker as a load of the amplifier Worked out: Bc.
Tutorial: Engineering technology Topic: Flat forming - punching, bending Prepared by: Ing. Elena Nová Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Tutorial: Mechanic - electrician Topic:Basics of electrical engineering the 2nd. year Basic characteristics of electric appliances Prepared by: Škarka.
Tutorial: Mechanic - electrician Topic: Basics of electrical engineering the 2nd. year Measurement of resistance Prepared by: Ing. Jiří Smílek Projekt.
Tutorial: Mechanic - electrician Topic: Technical training II. class Passive components – transformers Prepared by: Melichařík Lubomír Projekt Anglicky.
Tutorial: Mechanic - electrician Topic: Technical training II. class Transistors 2 Prepared by: Melichařík Lubomír Projekt Anglicky v odborných předmětech,
Physiological Effects of Electricity on Human Body by Mohd Yusof Baharuddin.
Area of Study 2: Electricity
To bring electric current into a building, an electrician installs wiring. In a house, all of the wires usually come from one main box.
Tutorial: Mechanic - electrician Topic: Basics of electrical engineering the 2nd. year Three-phase current Fuse Prepared by: Škarka Miloš Projekt Anglicky.
What Are Circuits? What is a closed circuit?
Tutorial: Mechanic – electrician Topic: Electronics II. class Operational Amplifiers: Inverting Amplifiers – Part 2 – Derivations Prepared by: Ing. Jaroslav.
Educational program: Mechanic - electrician Title of program: Technical training II. class The powerful amplifiers Worked out: Bc. Chumchal Miroslav Projekt.
Tutorial: Mechanic - electrician Topic: Technical training II. class Transistors 3 Prepared by: Melichařík Lubomír Projekt Anglicky v odborných předmětech,
What makes substation work?
Tutorial: Engineering technology Topic: Castings defects Prepared by: Ing. Elena Nová Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Tutorial: Mechanic - electrician Topic: Basics of electrical engineering the 2nd. year Three-phase current, electrification system Prepared by: Škarka.
Basic Electrical Safety
Tutorial: Mechanic - electrician Topic: Fundamentals of electrical engineering the 2nd. year, RCD Prepared by : Škarka Miloš Projekt Anglicky v odborných.
Tutorial: Mechanic - electrician Topic: Basics of electrical engineering the 2nd. Year Three-phase current Prepared by: Škarka Miloš Projekt Anglicky.
Tutorial: Mechanic - electrician Topic: Electronics II. Class Operational Amplifiers: Comparators – Part 1 - Basics Prepared by: Ing. Jaroslav Bernkopf.
Tutorial: Mechanic - electrician Topic: Electric measurement the 2nd. Year Measuring devices 3 Prepared by: Ing. Jiří Smílek Projekt Anglicky v odborných.
Výukový program: Mechanik - elektrotechnik Název programu: Základy elektrotechniky II.ročník, základní charakteristiky elektrických zařízení Vypracoval.
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/ je spolufinancován Evropským sociálním fondem a státním rozpočtem České republiky. Tutorial:
Tutorial: Engineering technology Topic: Volume forging- drawing of wires and profiles Prepared by: Ing. Elena Nová Projekt Anglicky v odborných předmětech,
Tutorial: Mechanic - electrician Topic: Technical training II. class Transistors 1 Prepared by: Melichařík Lubomír Projekt Anglicky v odborných předmětech,
Tutorial: Mechanic – electrician Topic: Electronics II. class Operational Amplifiers: Non-Inverting Amplifiers – Part 1 - Equations Prepared by: Ing.
Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/ je spolufinancován Evropským sociálním fondem a státním rozpočtem České republiky. Educational.
Tutorial: Engineering technology Topic: Volume forging – Extrusion Prepared by: Ing. Elena Nová Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Practical electricity 2: uses and safety. a battery… a current can only flow when a circuit is complete… 12V 0 V.
Tutorial: Engineering technology Topic: Hot forming Prepared by: Ing. Elena Nová Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/ je spolufinancován.
Tutorial: Mechanic – electrician Topic: Electronics II. class Operational Amplifiers: Integrator Prepared by: Ing. Jaroslav Bernkopf AVOP-ELEKTRO-Ber-006.
Tutorial: Mechanic - electrician Topic: Basics of electrical engineering the 2nd. year Protection in electric networks Prepared by: Škarka Miloš Projekt.
Training program: Mechanic - electrotechnician Program name: Digital processing - microprocessors III. class Microcontrollers Elaborated by: Vlastimil.
Tutorial: Engineering technology Topic: Resistance welding Prepared by: Ing. Josef Martinák st. Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Tutorial: Mechanic – electrician Topic: Electronics II.class Operational Amplifiers: Inverting Amplifiers – Part 1 - Equations Prepared by: Ing. Jaroslav.
What makes substation work?
Electrical Circuits Chapter 20 Section Three. Science Journal Entry #42 Expound upon Ohm’s Law and its relationship to current, resistance, and voltage.
Tutorial: Mechanic -electrician Topic: Electronics II. class Transistors: Transistor CE Amplifier Prepared by: Ing. Jaroslav Bernkopf Projekt Anglicky.
Electrical Safety Basic Electrical Safety. Electrical Safety  Course not designed to teach you to work on electrical equipment. Basic Electrical Safety.
Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Circuit Protection Unit 9.
Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Basic Electrical Safety
Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/
Safety Meeting Topics Standby Generator Safety
Basic Electrical Safety
Basic Electrical Safety
Basic Electric Principles
Presentation transcript:

Tutorial:Mechanic - electrician Topic:Basics of electrical engineering the 2nd. year Protection in electric networks Protection of inanimate parts Prepared by: Škarka Miloš Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/ je spolufinancován Evropským sociálním fondem a státním rozpočtem České republiky.

 The inanimate part is a conductive part of the electric device, which can be touched and isn‘t usually electrified, but where in case of the malfunction a dangerous contact voltage occurs (for example on the metal casing of the distributor).  The dangerous contact voltage is a voltage (or a variance of potentials), which can cause an injury by the electric current to the person or animal contacting the inanimate part during malfunction. Its size depends on the type of the environment, in which this contact happens (ČSN ).  The inanimate part is a conductive part of the electric device, which can be touched and isn‘t usually electrified, but where in case of the malfunction a dangerous contact voltage occurs (for example on the metal casing of the distributor).  The dangerous contact voltage is a voltage (or a variance of potentials), which can cause an injury by the electric current to the person or animal contacting the inanimate part during malfunction. Its size depends on the type of the environment, in which this contact happens (ČSN ).

 Normal – ordinary; cold; dusty (if the dust is not conductive and not flammable). Its character prevents the injury by the electric current.  Dangerous – hot, wet (even temporarily), dusty (if the dust is conductive and not flammable with the increased corrosive aggression), with shocks, outdoor places with the mechanical wear and the conductive environment. These are those places, where there is a temporary or permanent danger of the injury caused by the electric current because of external effects.  Extremely dangerous – wet, with the extreme corrosive aggression, places, where there is the danger of an injury greatly increased by adverse conditions (water, kettles and metal tanks, narrow spaces with metal materials, healthcare facilities or special regulations for specific protection). The danger of an injury is even more increased because of special conditions and outer effects.

areaspermanently allowed contact voltage of inanimate parts AC DC normal and dangerous50 2)120 extremely dangerous 1)2560 working in water without using tools, narrow spaces )Applies also for toys, some healthcare and other devices that may get in contact with human skin or hair or for premises, where level of danger demands it. 2)Allowed ripple is 10%.

Prevents passing of the electric current through the body of the person or animal, or the current is reduced to the safe amount or the device in case of malfunction automatically disconnects from the source. This objective is assured by:  An automatic disconnection from the source if a malfunction occurs.  Another level of isolation, so called additional isolation, which prevents the current passing, if there happens to be a breakdown of the basic layer of insulation (or rather the passing current is reduced to the safe amount).  Reducing of a malfunction current via the measure on the side of the source  Equalizing of the potential between inanimate parts and the environment, which causes reducing of the current amount passing through a body (applied in exceptional cases while meeting other protection measures).

Prevents passing of the electric current through a body of a person or an animal, or the current is reduced to the safe amount or a device in case of malfunction automatically disconnects from the source. This objective is assured by:  An automatic disconnection from the source if a malfunction occurs.  Another level of isolation, so called additional isolation, which prevents the current passing, if there happens to be a breakdown of the basic layer of insulation (or rather the passing current is reduced to the safe amount).  Reducing of the malfunction current via the measure on the side of the source  Equalizing of the potential between inanimate parts and the environment, which causes reducing of the current amount passing through a body (applied in exceptional cases while meeting other protection measures).

 For TN networks is valid:  The grounding of inanimate parts is carried out by the connection of an inanimate part using a protection conductor with the grounded point of the network, which is usually the node of the source. The principle of the automatic disconnection is described on the picture:

The path of the short circuit current is called the loop. The principle also implies the condition for an automatic disconnection in the TN network. For switching off, the impedance of the loop Zs has to be so small, that the short circuit current exceeds the amount of the current la ensuring an automatic action of the protection element in adequately short time. The short circuit current has the amount Uo/ Zs and has to be bigger than the current Ia. That implies the condition mentioned in ČSN  Zs × Ia < Uo

 What is the inanimate part  The dangerous contact voltage  Protection means for inanimate parts  The impedance loop

according to the picture: the path of the malfunction current and the nature of the automatic disconnection in the TN network

  ka/ochrana-dotyk.pdf ka/ochrana-dotyk.pdf  Elektro v praxi, 1 část, Solid Team