Designed by Mr. H.K. Schrage - Swedish Engineer in 1911.

Slides:



Advertisements
Similar presentations
Both Speed and p.f. Control
Advertisements

ENERGY CONVERSION ONE (Course 25741)
ELECTRICAL POWER AC MOTOR & DC MOTOR.
It is a particular type of a.c. exciter which is connected to the
Induction Motor •Why induction motor (IM)?
Single Phase Induction
Electric Motors and Generators
DC Motors electrical machine1 J 2006.
Power System Fundamentals
SYNCHRONOUS MACHINES SUBMITTED BY: Ms. APOORVA KANTHWAL
EE 306 DC MACHINES Hatem Al-Ghannam
Lesson 33 AC Generators.
Three-Phase AC machines
MODULE 4.
Introduction to Electrical Machines
DC GENERATOR CHAPTER-9.
Department of Electrical and Computer Engineering
Speed Control of D.C. Motors
PRESENTATION ON INDUCTION MOTOR
Module G1 Electric Power Generation and Machine Controls
Induction Motor Why induction motor (IM)? –Robust; No brushes. No contacts on rotor shaft –High Power/Weight ratio compared to Dc motor –Lower Cost/Power.
Induction Motors Prepared By : PRAGNESH, MEET, SAGAR, SAAVAN, KANISH
Chapter 18 Single-Phase Induction Motors
Induction Motors.
Chapter 5. Electric Machines.
Closed loop control.
Induction Machine The machines are called induction machines because of the rotor voltage which produces the rotor current and the rotor magnetic field.
Chapter 16: Synchronous Generators
STARTING OF 3PH INDUCTION MOTOR
AC Machines Fundamentals. Introduction Synchronous machines: Motors and generators whose magnetic field is supplied by a separate dc power supply. Induction.
Electric Machine Introduction
EET 221 Synchronous Machines Rafiqi.
Electro Mechanical System
DC Machines and Drives . Books
Magnetic field due to an electric current
DC Machines.
INDUCTION MOTOR.
UNIT – II ELECTRICAL MACHINES.
BASIC ELECTRICAL TECHNOLOGY DET 211/3
Prepared by:- Chandan pathak ( ) Utpal rathod( ) Hitendra vyas( )
AC Machines. BOOSTER Basic Function:- -Sometimes when we use electrical power we need different voltage level to main supply. It is provided by Booster.
Induction Motor (Asynchronous Motor)
INTRODUCTION A 3-phase induction motor cannot be operated at variable speed. 1-phase induction motor is not self starting. Thus, A.C. commutator motors.
Synchronous Motors Introduction An alternator may operate as a motor by connecting its armature winding to a 3-phase supply. It is then called a synchronous.
EXPERIMENT NO.: 1. To Study the Variation of Speed and Load Test on Schrage Motor.
Electrical Motor1 3 Phase Induction Motor Mrs R.U.Patil Sr.Lecturer,EPS Dept. V.P.M’s Polytechnic,Thane.
CHAPTER 10 SYNCHRONOUS MOTOR Electrical Machines.
THREE-PHASE INDUCTION MOTOR
CHAPTER 3 DC MOTOR Electrical Machines.
Electric Motors and Generators
Single Phase Induction
DC Generators.
Electric Machine Induction Motor
Unit – III Three phase Induction Motor
Principle of Operation
Electric Machine Introduction
AC and DC motors.
INDUCTION MOTOR.
Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB
Synchronous Motors and Generators
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Advanced Power Systems
Induction Motor (Asynchronous Motor)
Electric braking Powerpoint presentation by:- Poonam sharma
Principle of Operation
Think beyond.
Chapter 36 Single – Phase Motors. Chapter 36 Single – Phase Motors.
Chapter 35 Computations And Circle Diagrams. Chapter 35 Computations And Circle Diagrams.
Induction Motors (Lecture 1&2)
Electric Machine Design Course
Presentation transcript:

Designed by Mr. H.K. Schrage - Swedish Engineer in 1911. SCHRAGE MOTORS Designed by Mr. H.K. Schrage - Swedish Engineer in 1911. It is a ROTOR fed, Shunt type, Brush shifting, 3 Ø Commutator Induction Motor which has built in arrangement both for speed control and p.f. control. Same is an “Inverted Induction Motor” with Slip regulator. CONSTRUCTIONAL DETAILS Motor has three windings: Two in Rotor and One in Stator. Primary wdg: Placed on the lower part of the slots of the Rotor. 3 Ø supply at line frequency is fed through slip rings and brushes. Generates working flux in the machine. DEE_JRN

Regulating Wdg: Placed on the upper part of the slots of the Rotor. Connected to commutator segments in a manner similar to that of d.c. machine. Also known as tertiary wdg / auxiliary wdg / commutator wdg. Secondary winding: Same is Phase wound & located on Stator. Each Wdg connected to a pair of brushes arranged on the commutator. Brushes mounted on brush rockers. Designed to move in opposite directions, relative to the center line of its stator phase. Brushes A1 , B1 & C1 move together and are 1200 E apart. Brushes A2 , B2 & C2 also move together and are 1200 E apart. DEE_JRN

DEE_JRN

Transformer action occurs between primary and regulating wdgs. WORKING OF SCHRAGE MOTOR Primary energized with line frequency voltage. Transformer action occurs between primary and regulating wdgs. Induction motor action occurs between primary and secondary wdgs. Commutator acting as a frequency converter converts line frequency voltage of reg. wdg to slip frequency voltage and feeds the same to secondary wdg on the stator. Voltage across the brush pairs A1 - A2, B1 - B2 & C1 - C2 increases as brushes are separated. Magnitude of voltage injected into the secondary wdg depends on the angle of separation ‘θ’ of the brushes A1 & A2, B1 & B2 , C1 & C2. (‘θ’ – Brush separation angle) DEE_JRN

direction is set up in the rotor core. When primary is energized synchronously rotating field in clockwise direction is set up in the rotor core. Assume that the brushes are shortcircuited through commutator seg. i.e. the secondary is short circuited. Rotor still at rest, the rotating field cuts the stationary secondary wdg, induces an e.m.f. The stator current produce its own field. Stator field reacts with the rotor field thus a clockwise torque produced in the stator. Since the stator cannot rotate, as a reaction, it makes the rotor rotate in the counter clockwise direction. DEE_JRN

Suppose that the rotor speed is Nr rpm. Rotor flux is rotating with NS relative to primary & regulating wdg. Rotor flux will rotate at slip speed (NS - Nr ) relative to secondary wdg in stator / with reference to space. SPEED CONTROL Speeds above and below Synchronous speed can be obtained by changing the Brush position. i.e. changing “ θ “ . Fig (a) – Brush pair on the same commutator segment. i.e. the secondary wdg short circuited. Injected voltage Ej = 0 and the m/c operates as an INVERTED Induction Motor. Nr < NS . DEE_JRN

DEE_JRN

corresponding secondary phase, then E2 and Ej are in phase opposition. Fig. (b) – Brushes parted in one direction - produces sub-synchronous speed. Injected voltage Ej , is obtained from the section of the regulating wdg between them. If the center line of this group of conductors is coincident with the centre line of the corresponding secondary phase, then E2 and Ej are in phase opposition. Neglecting impedance drop, sE2 must be equal and opposite to Ej. “β” – angle between E2 and Ej. β=1800 & Nr < NS . Fig. (c) – Brushes parted in opposite direction - produces super-synchro. speed. Ej is reversed relative to E2. i.e. β=00 & sE2 must also be reversed. Same occurring only because ‘s’ becoming negative . i.e. The speed is thus above synchronous speed. Nr > NS . The commutator provides maximum voltage when the brushes are separated by One pole pitch. i.e. ‘θ’ = 1800 E. DEE_JRN

POWER FACTOR IMPROVEMENT Same obtained changing the phase angle of the injected voltage into the secondary winding. In this case one set of brushes is advanced more rapidly than the other set. Now the two center lines do not coincide, have an angle ‘ρ’ between them. (“ρ” – Brush shift angle) Fig (d) : Brush set is moved against the direction of rotation of rotor. In this case Speed decreases, the p.f. is also improved. Fig (e) : Brush set is moved in the same direction of rotation of rotor. In this case Speed increases, the p.f. is also improved. Both p.f. and speed can be controlled by varying ‘θ’ & ‘ρ’. ‘Ej Cos ρ’ and ‘Ej Sin ρ’ effect the speed and p.f. respectively. DEE_JRN

DEE_JRN

Speed Torque Characteristics Same reveals that the Schrage Motor is almost a constant speed motor. (SHUNT CHARACTERISTICS) Applications Can be applied to any individual drive requiring Variable speed. Especially in Hoisery knitting & Ring spinning m/cs. Cranes & Hoists Fans & Centrifugal Pumps Printing Machinery Conveyors, Packing machinery & Paper Mills DEE_JRN

High p.f. for high speed setting. ADVANTAGES Good Speed Regulation. High p.f. for high speed setting. High efficiency at all speeds except NS. DRAWBACKS Operating voltage has to be limited to 700V because the power is to be supplied through slip rings. Low p.f. at low speed settings. Poor commutation. High Cost. DEE_JRN

Variation of no load speed with Brush Separation K= Turns Ratio= No: of Secondary turns / No: of tertiary turns DEE_JRN