Progress on the New High Intensity Cold Neutron Spectrometer, MACS C. Broholm 1,2, T. D. Pike 1,2, P. K. Hundertmark 1,2, P. C. Brand 2, J. W. Lynn 2,

Slides:



Advertisements
Similar presentations
Focusing monochromators/analyzers Asymmetric diffraction geometry of the monochromator Dispersive double crystal monochromator Two wavelength sandwich.
Advertisements

4/13/2017 5:04 PM Diffraction © 2007 Microsoft Corporation. All rights reserved. Microsoft, Windows, Windows Vista and other product names are or may be.
Diffraction of Light Waves
X-ray sources Sealed tubes - Coolidge type common - Cu, Mo, Fe, Cr, W, Ag intensity limited by cooling req'ments (2-2.5kW) Sealed tubes - Coolidge type.
MARS15 Simulations of the MERIT Mercury Target Experiment Fermilab March 18, Neutrino Factory and Muon Collider Collaboration meeting Sergei.
Chapter 25 Optical Instruments.
1 Components of Optical Instruments, Cont… Lecture 7.
Figure 2.1 Block diagram of a generic projection imaging system.
Interim progress summary: ITER Imaging X-ray crystal spectrometer design Sam Davis - UKAEA Robin Barnsley - ITER.
Polarized Beams Using He-3 at the NCNR Triple-Axis Spectrometers Ross Erwin Tom Gentile Wangchun Chen Sarah McKenney.
Conceptual Design: MACS is designed to maximize the efficiency for energy resolved surveys of Q-space in the sub-thermal energy range. Two innovations.
Abstract A time resolved radial profile neutron diagnostic is being designed for the National Spherical Torus Experiment (NSTX). The design goal is to.
Instrument Development Test Station at HFIR CG1 Lowell Crow, May 15, 2009.
R2D2 fast overview Sept version This document is a short description of the R2D2 test beam line at the JEEPII reactor at IFE, Norway. (Contact: Isabel.
HYSPEC HYSPEC INSTRUMENT DESIGN – OUTLINE  The two “models” considered for HYSPEC – inside & outside (Mark)  A breakdown of the components of the two.
Michael Jentschel Institut Laue-Langevin ELI-NP, March 2011, Bucharest.
MACS –a New High Intensity Cold Neutron Spectrometer at NIST February 17, 2003Timothy D. Pike1 Developing MACS A Third Generation Cold Neutron Spectrometer.
PHYS 430/603 material Laszlo Takacs UMBC Department of Physics
Simulations of the double funnel construction for LET. Comparison with a single funnel The aim was to optimise the double funnel configuration to give.
20to2T5m100cm Images Van Graves February 13, 2014.
Choosing the Right Neutron Spectrometer Dan Neumann NIST Center for Neutron Research
Building MACS  Goals of the MACS project  Funding and time line  Technical overview  Possible IDG contributions  Process for IDG involvement in MACS.
X-Ray Measurement Methods From Chapter 6 of Textbook 2 and other references Diffractometer Hull/Debye-Scherrer method Pinhole method Laue Method Rotating.
Assessing Single Crystal Diamond Quality
Motor driven incident slits (define the incident x-ray beam size) Synchrotron x-ray upstream beam aperture CCD camera Video camera Long working distance.
M. Dugger, February Triplet polarimeter study Michael Dugger* Arizona State University *Work at ASU is supported by the U.S. National Science Foundation.
Stability Requirements for Superconducting Wiggler Beamlines
MACS Concept and Project Status Making best use of CW source MACS-imizing incident flux MACS-imizing detection efficiency From concept to reality Collin.
ELECTRON MOVING AT CONSTANT VELOCITY
8 th World Conference on Neutron Radiography  Gaithersburg, MD USA  October Imaging of Neutron Fields with Submicron Resolution R. Gregory Downing.
The NCNR Spin-Polarized Triple-Axis Spectrometer (SPINS) The SPINS instrument is located at the heart of the cold neutron guide hall of the NIST Center.
Shielding Helium Cold neutron source Shutter Cooled filters Radial Collimators Variable Aperture Focusing monochromator on translation stage Focusing monochromator.
1 Fraunhofer Diffraction: Circular aperture Wed. Nov. 27, 2002.
Proposed NSLS X13B Microdiffraction Instrument Source & Optics James M. Ablett National Synchrotron Light Source.
MACS –a New High Intensity Cold Neutron Spectrometer at NIST September 24, 2002Collin L. Broholm Timothy D. Pike 1 Scientific Program and Requirements.
Parameters of the new diffractometer “ARES” Aleksey E. Sokolov PNPI NRC “KI”
Conceptual design and performance of high throughput cold spectrometer : MACS Why MACS Layout and key elements Performance Data collection Scientific program.
Cold Neutron Spectroscopy on MACS  Virtues and limitations of INS  Enhancing INS at the NCNR  Description of MACS  Science on MACS  Integration of.
Past and Future Insights from Neutron Scattering Collin Broholm * Johns Hopkins University and NIST Center for Neutron Research  Virtues and Limitations.
Neutron Scattering Group February, 2001 A High Performance Instrument for the Single Crystal Spectroscopy at the Pulsed SNS. n What is the spectrometer.
MCNSI meeting, February 2006 Contents: People –V. Ryukhtin left for part time only Multichannel focusing benders – continuation –resolution functions.
NMI3 meeting, ISIS, September 26-29, 2005 Contents: Overview of new capabilities of the RESTRAX software Numerical optimizations of TAS parameters Virtual.
A New High Intensity Cold Neutron Spectrometer at NIST J. A. Rodriguez 1,3, P. Brand 3, C. Broholm 2,3, J.C. Cook 3, Z. Huang 3, P. Hundertmark 3, J. Lynn.
Laser Spectroscopy/SJX Chap. 4 Components of Spectroscopic Instruments 1 In this chapter we discuss basic spectroscopic instruments and techniques employed.
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
HYSPEC IDT Introduction to HYSPEC: Overview of the Conceptual Design and Top Level Specifications. Outline Overview of the HYSPEC layout and principal.
Neutron Scattering Group March, 2001 A High Performance Hybrid Spectrometer for the Single Crystal Spectroscopy at the Pulsed SNS  Scientific case and.
By Abdullah Framalawi Aly Abouhaswa Polarized Neutron Spectrometry : Studying nanostructure magnetism with the use of polarized neutron reflectometry.
HYSPEC IDT Polarized Beam Mode for the Hybrid Spectrometer (HYSPEC) at the Spallation Neutron Source. Outline Polarization analysis and the HYSPEC place.
Astronomical Spectroscopic Techniques. Contents 1.Optics (1): Stops, Pupils, Field Optics and Cameras 2.Basic Electromagnetics –Math –Maxwell's equations.
Date of download: 6/3/2016 Copyright © 2016 SPIE. All rights reserved. Propagation of optical rays through a volume Bragg grating in transmitting (dotted.
October, 2001 Hybrid Spectrometer for Single Crystal Studies at the Pulsed SNS: an update. n Principal features of the proposed hybrid spectrometer. n.
Date of download: 7/2/2016 Copyright © 2016 SPIE. All rights reserved. Applying Eq. (1) and a thermal analysis for relating junction temperature (Tj) to.
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
Astronomical Spectroscopic Techniques
© 1997, Angus Rockett Section I Evaporation.
Date of download: 10/14/2017 Copyright © ASME. All rights reserved.
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
LEAD Tutors/Peer Instructors Needed!
Crystal and X-ray Diffraction
The “Roll and Lock” Mechanism of Force Generation in Muscle
The “Roll and Lock” Mechanism of Force Generation in Muscle
Ruitian Zhang, Rosangela Itri, Martin Caffrey  Biophysical Journal 
Volume 74, Issue 5, Pages (May 1998)
Monte Carlo simulations for the ODIN shielding at ESS
Optics John Arthur, SLAC & William W. Craig, LLNL April 24, 2002
Scope Setting Meeting MIRACLES
Volume 106, Issue 5, Pages (March 2014)
Alexander Spaar, Christian Münster, Tim Salditt  Biophysical Journal 
Volume 91, Issue 4, Pages (August 2006)
Presentation transcript:

Progress on the New High Intensity Cold Neutron Spectrometer, MACS C. Broholm 1,2, T. D. Pike 1,2, P. K. Hundertmark 1,2, P. C. Brand 2, J. W. Lynn 2, D. J. Pierce 2, J. Moyer 2, J. G. LaRock 2, S. A. Smee 1, G. Scharfstein 1, R. Hammond 1, and J. Orndorff 1 1 Department of Physics and Astronomy, Johns Hopkins University, Baltimore, MD NIST Center for Neutron Research, Gaithersburg, MD Figure 7. Flux on sample versus incident energy calculated using Monte Carlo Simulation (MCSTAS). Fig. 4. Image of the MACS doubly focusing monochromator mounted with mirrors for optical testing. The device contains 357 pieces of 1 o mosaic PG(002) for a total area of 1428 cm 2. Each of the 21 vertical aluminum blades rotates independently by individual stepping motors thus providing full flexibility for horizontal focusing. Vertical focusing is achieved through compression. The blades have been profiled so the front blade surface assumes a circular shape in compression. Figure 5. Isometric view of the MACS cold neutron spectrometer. Shutter Collimators Variable aperture Fig. 6. top view of MACS. The detector system is shown in a single setting while the monochromator is indicated in three different positions. Horizontal monochromatic focusing requires that the monochromator is tangent to the dashed Rowland circle. kiki kiki kfkf kfkf Q Q Figure 8. The region of Q-space mapped by MACS for Ef=3.7 meV and ħ  =1 meV. The ellipses show the areas probed in one setting. Focusing Monochromator System Multi-channel Detector System Fig. 1. A helium filled cask contains all items associated with converting a divergent white neutron beam to a monochromatic beam that converges on the sample. Fig. 2. Energy resolution is controlled by a segmented radial collimating system. The blades of the device converge at the center of the cold source. Two in-line segments A and B are available. Segment A provides 60’ divergence of radiation incident on a volume element of the monochromator. Segment B alone reduces this divergence to 40’. Segments A and B together provide 24’ divergence. Fig. 3. Wave vector resolution is controlled by a variable beam aperture. It defines the envelope of the neutron beam. The fully open aperture subtends Sr to the source. There are two degrees of freedom: Beam Width and beam height. The shutters are 10 cm thick and made from high density poly-ethylene followed by Hot Pressed B 4 C. Radiation hardened motors and resolvers are used. Be, PG, Al 2 O 3 Cryo filters Be, PG, Al 2 O 3 Cryo filters Fig. 9. The detection system consists of 20 identical channels separated by 8 o for a total of 160 o coverage in one setting. Each channel contains: (a) Cooled Be, BeO, or PG filter (b) 20’-40’-60’ or open collimation. (c) Double Crystal analyzer (see below) (d) Diffraction detector (e) Spectroscopic detector Fig. 10. Sample positioning system to rotate, translate, and tilt a large cryo- magnet. Fig. 11. The internal frame work of the MACS post sample cryo-filter system. It will cool 3× 20 filters to <77 K using a closed cycle compressor system. Fig. 12. One of the 20 vertically focusing double crystal analyzer systems in the MACS detector. A single stepping motor operates each device from below. The range of analyzer scattering angles is 40 o to 140 o. The PG(002) graphite from GE has an average mosaic of 1.4 o. The area of a single vertically focusing blade is 108 cm 2. The total solid angle of the detection system is approximately 0.15 Sr.