Settings & Adjustments. Settings & Adjustments.

Slides:



Advertisements
Similar presentations
Service Section Technical Training.
Advertisements

Series L Air conditioners for Laboratories.
USER MAINTENANCE.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Daikin Altherma™ Troubling Shooting
Operating Nitrox Systems 11 Presented by Nuvair. Operating Nitrox Systems2 Membrane systems produce nitrox efficiently Compressed air flows through the.
Refrigerators.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
1. 2 Maintenance & Troubleshooting 3 Maintenance Three-monthly checks Carry out the following checks every three months: check the power supply; check.
38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
① The output signal of a room thermostat is ON or OFF according to changes of room temperature ② The power supply to a motorized valve is ON or OFF according.
Wine Cellar Split System Basics. Definitions Split System – A cooling unit that “splits” the cooling coil and the condenser apart into two remote pieces.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
TECHNICAL TRAINING 2008.
Customer Service VICTRIX 90 Central heating only, wall hung condensing boiler.
Sunday, May 17, 2015 Pressure Booster Service. Sunday, May 17, 2015 Booster Service Basics Control Panel Components Setting a pressure switch Setting.
Installation and Initial Start Up by Martin Noska, Service Engineer, Aftersales & Service.
Installation and Initial Start Up Worldwide Manufacturer of PSA Generators by Laco Remias, Service Engineer, Aftersales & Service.
OXYTRONIC 600 CONTINOUS FLOW NITROX SYSTEM
HVACR416 - Design Humidification. Relative Humidity 1.Air in the home is artificially dried out when it is heated. 2.Because warm air expands, this expansion.
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
Product Introduction.
Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
Aqualean Product Presentation 1 By Laurent Domenget Product Manager, Rooftop & Packaged Air Units.
AccuMax Multi-Point Injection Mechanics
STEAM HEATING.
Pool system components - solar collectors - Temperature probes relief pool - Solar pump system - Pump filtration system - Relief valve - air temperature.
Pressure Switches. New modulating and multi-stage furnaces are more complex and require that installation instructions and procedures be followed so that.
Troubleshooting Electric Control Devices
Domina PLUS B WORKING DIAGRAMS TROUBLESHOOTING INTERNAL VIEWS WIRING DIAGRAMS INSTALLATION 03 PREVIOUS MODEL.
1 AFPS. 2 AFPS: Automatic Floor Pressurization System This special application, which modulates the fan speed by means of a differential pressure sensor.
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
I Pag 1 Microchiller 2. I Pag 2 I Pag 3 Information on the display.
Installation Rules. Installation Rules In Leonardo Evolution units, the air flow can be upwards or downwards. Introduction In Leonardo Evolution units,
Air Conditioning Heating Refrigeration
Engineer Training Cooler TJ8300 / TJ8500 Cooler. Engineer Training Cooler TJ8300 / TJ8500 Confidential 2 Introduction.
Vacuum system.
Engineer Training Pneumatic System Overview. Engineer Training Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:  Y Pistons.
Why Maintenance Tasks are Important Produced by Joe Marchese.
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
TECHNICAL TRAINING INVERTER-Y
XAS 375 CD6 Compressors Committed to sustainable productivity
CUE – Make Any Pump an E-Pump
© 2013 Eaton Corporation. All rights reserved. easy Programmable Relay Training Program Exercise 3.
James McIntyre VRF Training Manager V5 Key Components.
E3 HVACR Controls and Devices
MACHINE OPERATION.
Fixed Orifice Tube Cycling Clutch System (FOTCC)
Quick Start Guide for Flex Flow Pump
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
E3 HVACR Controls and Devices
Air Distribution Control
HIGH PERFORMANCE PRESSURE SYSTEMS.
T-6B On-Board Oxygen Generation System (OBOGS)
Roof Top Unit Overview (MAGNUM)
The Safe Use of Electricity
By: JAGDEEP SANGWAN Refrigeration Basics 101.
Refrigeration and Air Conditioning
Refrigeration and Air Conditioning
HYBRID AIR COOLING TECHNOLOGY
HVAC Schematic Symbols
Champion RotorChamp HP
Champion RotorChamp HP
Door Heat Exchanger: Specification
T-6B On-Board Oxygen Generation System (OBOGS)
Presentation transcript:

Settings & Adjustments

Fans Standard voltage levels for Leonardo Evolution units WARNING! In the case of a unit with ducts, the load loss from the exhaust duct must be less than 100 Pa.

Fans MODELS WITH AN AUTOTRANSFORMER In the TD*R and TU*R units, the speed of the fan rotation can be varied by using the ATR transformer: To obtain the required prevalence of the plant, it is possible to vary the voltage by selecting one of the following levels: Models 0511-0611: 140V - 160V - 180V - 190V - 200V - 210V - 220V -230V Models 0721-1822: 230V - 250V - 260V - 270V - 280V - 290V - 300V - 310V - 320V - 340V - 360V - 380V - 400V. Models 2222 - 2242 - 2522 - 2542 - 2842 - 3342: 150V - 180V - 200V - 230V - 240V - 260V - 280V - 300V - 320V - 340V - 360V - 380V - 400V.

Fans In these tables the maximum pressure available (expressed in Pa) for each voltage level of the transformer is indicated. The values are given for the maximum air flow (expressed in m3/h).

Fans After having selected the voltage level, carry out the connection in the following way: • with the unit turned off, open the front panels and the door of the electrical panel and the internal protection panels; • select the voltage supply by positioning the main switch to “0” (OFF); • Follow the diagrams displayed on the right and refer to the wiring diagram of each unit to connect the two electric wires found on the fan, or on the connector block, to the corresponding terminals on the autotransformer.

MODELS WITH A PHASE CONTROL VOLTAGE REGULATOR Fans MODELS WITH A PHASE CONTROL VOLTAGE REGULATOR To reach the head required by the system for conditioners with fans carrying a CE marking, the input voltage percentage can be adjusted from the user terminal (A). To select the voltage percentage to be applied, carry out the following procedures: • on the user terminal press the PRG button; • using the UP or DOWN key select SERVICE MENU and confirm using the ENTER key; • enter the password (see the envelope attached to the manual); • using the UP or DOWN key select HARDWARE SETTING and confirm using the ENTER key; • using the UP or DOWN key select EVAPORATING FAN and confirm using the ENTER key; • set the amount and confirm using the ENTER key.

Fans In these table the maximum pressure available (expressed in Pa) for each voltage level of the transformer is indicated. The values are given for the maximum air flow (expressed in m3/h).

Safety Devices After starting up the unit, set the following set points (see the microprocessor control manual): • Room temperature (cooling and heating set point); • Relative room humidity (humidification and dehumidification set-point); • Dirty filter differential pressure switch: see paragraph "Setting the dirty filter sensor". The settings of the safety devices must not be modified.

Safety Devices Setting the pressostatic valve (optional on chilled water cooled models only) The pressostatic valve, by controlling the water flow, prevents the condensing pressure falling too low and at the same time minimizes water consumption. When necessary, set the pressostatic valve by turning the regulation knob (the pressure increases when turning it clockwise) until the condensation pressure stabilizes to recommended value of 16 bar (equivalent to a saturation temperature of approximately 45 °C in the case of R22) checking the pressure with a gauge fitted to the pressure tapping of the compressor discharge valve.

Setting the air flow sensor Safety Devices Setting the air flow sensor The FS differential pressure switch intervenes if the fan (or one of the fans) stops working. The factory set point of the FS differential pressure switch is at 0.8 mbar (= 80Pa). Because the pressure drop between the suction and discharge of the fans depends on the air flow, it may be necessary to calibrate the instruments after installation, checking that the contact closes when the fans are working. To set the FS pressure switch, carry out the following procedure: • simulate a fan fault by stopping a fan; check that the pressure switch intervenes; • if the pressure switch does not intervene, gradually increase the setting until the pressure switch switches off by using an adjustment screw and setting the differential pressure switch on a scale from 0.5 to 4.0 mbar (from 50 to 400 Pa).

Setting the dirty filter sensors Safety Devices Setting the dirty filter sensors The PFS differential pressure switch is set according to the loss of load dependent on the dirt inside the filters and the air flow. The PFS differential pressure switch must be set at 3.5 mbar (=350 Pa). To set the PFS pressure switch, carry out the following procedure: • gradually cover the surface of the air filter and check that the pressure switch intervenes when the filter is about 50-60% covered; • if the pressure switch does not intervene, gradually lower the setting, if it cuts in too soon, increase the setting: using a star screw driver turn the regulation screws of the pressure switch to the desired value.