ENTC 4350 Modern Ventilators. Modern Ventillators Ventilation assistance is provided under either of two conditions: (1) breathing initiated by a timing.

Slides:



Advertisements
Similar presentations
Respiratory System Physiology
Advertisements

CPAP/PSV.
Functions of the Respiratory system
Medical Instrumentation Application and Design, 4th Edition
Unit 3 Review.
Basic Refrigeration Cycle
Pneumatics Pneumatik By Clifford Mayhew St Helens College
Using the “Clicker” If you have a clicker now, and did not do this last time, please enter your ID in your clicker. First, turn on your clicker by sliding.
Refrigeration Flow Control
The bird IPPB machine The Bird is pneumatically powered & controlled.
Oxygen Concentrators.
Trigger/Limit/Cycle/Baseline
HVACR312 - Refrigeration Metering Devices.
Medical Instrumentation Application and Design, 4th Edition
RESPIRATION Dr. Zainab H.H Dept. of Physiology Lec.5,6.
Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Chapter 42 Mechanical Ventilators.
By Dr. Ahmed Mostafa Assist. Prof. of anesthesia and I.C.U.
Ventilator.
Actuators.
How Ventilators Work Chapter 3. To care for a ventilator patient, you need to know: The various functions of the ventilator used How the ventilator interacts.
Parts of the Anesthetic Machine
The mechanics of breathing and Respiratory Volumes
Classification of Instruments :
1 Life Products LP-6, LP 6 Plus and LP 10 Home Ventilator By Bryce Younger.
ENGR 8-4, Lesson 2 Hydraulic and Pneumatic Systems
Abs.
Highlights of Unit 3: Classification of mechanical ventilation
Chapter 18 Direct Current Circuits. Chapter 18 Objectives Compare emf v potential difference Construct circuit diagrams Open v Closed circuits Potential.
Lung Volumes and Gas Distribution - Testing Equipment RET 2414L Pulmonary Function Testing Module 3.1.
Without reference, identify principles about volume/pressure and high frequency ventilators with at least 70 percent accuracy.
Results from kinetic theory, 1 1. Pressure is associated with collisions of gas particles with the walls. Dividing the total average force from all the.
Critical Care Ventilation Technology Perspective Fran Hegarty.
CHAPTER 5: Mass and Energy Analysis of Control Volumes
Ventilators Tuesday, 20 April 2004 Bill McCulloch.
These are measured with a spirometer This is estimated, based on
IPPB: Bennett valve tutorial
Lesson 9 COMPRESSION PROCESSES Apply the ideal gas laws to SOLVE for the unknown pressure, temperature, or volume. DESCRIBE when a fluid may be considered.
Presentation title slide
Chapter 9 Lung, Kidney, Bone and Skin. Figure 9.1 The spirometer measures lung capacities and lung volumes. Because the subject cannot make the lung volume.
Parts of the Anesthetic Machine A&A Pages
He3 dilution refrigerator
3 nd LECTURE VENTILATORS Part One. Ventilators One of the major life support systems. Ventilators take over the vital role of the respiratory muscles.
Ventilatory Modes. Volume Controlled Mandatory Breath Gas is delivered at a constant flow until the set tidal volume is reached. Pressure rises to a.
Balances The balance is an instrument which measures the mass of a body or substance using the gravity force which acts on that body At present, there.
Mechanical Ventilator
CHAPTER 5 DC AND AC BRIDGES.
TITLE OF THE PROJECT:- AUTOMOBILE AIR CONDITIONING AIM OF THE PROJECT:- TO STUDY ABOUT AIR CONDITIONING SYSTEM OF AN AUTOMOBILE PRESENTED BY: INAMUL.
MECH1300 Pneumatic Components Topics Pneumatic Cylinders Pneumatic Motors Other Pneumatic Actuators Pneumatic Directional Control Valves Pneumatic Flow.
Copyright © 2003 Pearson Education, Inc. publishing as Benjamin Cummings. RESPIRATORY SYSTEM PowerPoint ® Lecture Slide Presentation by Robert J. Sullivan,
PRESSURE CONTROL VENTILATION
Mechanical Ventilation
James McIntyre VRF Training Manager V5 Key Components.
Engineering II – August 2016
Unit III Class I Pneumatics.
CHAPTER 6 MESB System Modeling and Analysis Hydraulic (Fluid) Systems
Anesthesia Equipment Session 3
Mechanical Ventilator 2
Mechanical Ventilator 1
Mechanical ventilator
Pneumatic schematic of the Dräger Infinity V500 intensive care ventilator. A. Gas-mixture and gas-metering assembly. Gas from the supply lines enters the.
Air Distribution Control
Pneumatics Pneumatik By Clifford Mayhew St Helens College.
Respiratory system Respiration is the process by which the body takes oxygen in and removes carbon dioxide Every cell in our body needs a constant supply.
Sophie Young 21st February 2007
What it Means to Breathe
Prepared by Dr. Mohamed Ahmed Awad
Mechanical ventilator
Ventilation: The Mechanics of Breathing
Active Reciprocating Compressor Valve Assembly P16452
CHAPTER 59 TRANSISTOR EQUIVALENT CIRCUITS AND MODELS
Presentation transcript:

ENTC 4350 Modern Ventilators

Modern Ventillators Ventilation assistance is provided under either of two conditions: (1) breathing initiated by a timing mechanism or (2) patient-initiated breathing.

Automatically timed breathing is usually provided for patients who cannot breathe on their own. It provides inspiration and expiration at fixed rates and durations except for periodic sigh; a sigh is a rest period for the patient.

Patient-initiated breathing may be given to one who has difficulty breathing due to high airway resistance. The patient’s effort to inhale triggers the respirator unit to deliver air at the positive pressure prescribed.

Ventilator Modes of Operation The following definitions are commonly used to describe respirator/ventilator operation: CMVContinuous mandatory ventilation: Once initiated by either the ventilator operator or the patient, the breath is driven to the patient. CPAPContinuous positive airway pressure: Breaths are spontaneous, unless the operator intervenes. The spontaneous breaths are determined entirely by patient effort. However, the air/oxygen mixture is set by the ventilator.

SIMVSynchronized intermittent mandatory ventilation: These breaths are initiated by either the machine, the operator, or the patient. The breaths may be either spontaneous or mandatory. That is, if the patient does not breathe within a preset time period, the ventilator will deliver a breath. PEEPPositive end-expiratory pressure: The pressure maintained by the ventilator that the patient must exhale against.

ApenaThe patient has stopped breathing. SighA breath delivered by the ventilator that differs in duration and pressure from a nominal breath. NebulizerA device for producing a fine spray of liquid or medication into the patient’s air.

The block diagram shows the external flexible tubing and the ventilator unit.

Air from the ventilator during patient inspiration passes through a bacterial filter and humidifier. A nebulizer may spray medication into the air. This air then forces valve 1 up to close off the spirometer and deliver air to the patient.

After the inspiration air is turned off by the ventilator, valve 1 drops and the patient exhales into the bellows, which has its outlet valve held closed pneumatically by the ventilator unit. During the subsequent patient inspiration cycle, that valve will open, causing the bellows to fall and empty.

During patient expiration, the direction of the air in the pneumatic system is determined by the main solenoid, which is switched appropriately by the system electronics. Room air is drawn from the air inlet filter by the main compressor and is directed through the main solenoid to hold closed the upper outlet valve of the bellows located inside the unit.

Next, the weight of the bellows causes the bottom bellows chamber outlet valve to open, as the main solenoid directs air to close the inlet bellows chamber valve. The weight of the falling bellows draws oxygen-enriched air into it in preparation for the patient-inspiration part of the cycle.

The oxygen content of the air flowing into the bellows is controlled by a percentage control valve, which regulates the resistance to room air and oxygen appropriately.

At the end of patient expiration, the system electronics trip the main solenoid, thereby initiating the patient- inspiration part of he cycle.

During patient inspiration, the compressor draws room air through an air filter and then through the main solenoid. It forces the bottom inlet valve of the internal bellows chamber open and forces the bottom bellows chamber outlet valve closed.

The high pressure in the bellows chamber compresses the bellows, forcing open the upper outlet valve set free by the main solenoid. This allows the oxygen-enriched air to pass through the main bacteria filter into the external tubes and then to the patient lungs.

A sensitivity control monitors the negative pressure necessary to initiate inspiration when the respirator is used in the patient-initiated breathing mode called the assist mode. A nebulizer compressor may draw air from the bellows and force it through an aspirator to mix medication into the patient-inspired air.

When inspiration is complete, the main solenoid switches the direction of the pneumatic air to repeat the expiration cycle, and so on.

The black bag at the end of the tubing simulates a compliant lung. This respirator may be operated using compressed air from the hospital air supply.

In that mode, the ventilator can be removed from its internal compressor, thereby decreasing it in size; turning off the compressor also reduces problems in instrument noise control.

To aid patient respiration, hospital air and oxygen enter the pneumatic compartment, where it is filtered. A check valve reduces the pressure to a nominal 10 psi.

A proportional solenoid valve assembly allows the air/oxygen mix to be controlled by the system electronics. A check valve directs air to the patient during the inspiration cycle.

During the subsequent expiration phase, the system electronics opens the check valve, CV5, to provide a vent for the patient exhalation air. In this case, the pneumatically operated valves of older ventilators have been replaced by valves controlled with microprocessor- based electronics.

A small positive-pressure ventilator is illustrated with both front and back views.

PNEUMOTACHOGRAPH AIRFLOW MEASUREMENT Patient airflow may be measured by changes in resistance of a thermistor in the airstream due to the cooling effect of flowing air. But it must be calibrated to compensate for changing ambient temperature.

To eliminate this disadvantage, a strain-gauge wire mesh is often used.

The airflow in either direction puts a strain on the screen and changes the resistance of its strain gauge.

The strain gauge is a component of a Wheatstone bridge.

Here the change in resistance,  R, is proportional to the airflow, F, past the wire mesh.

Voltage divider rule

Getting a common denominator

If R »  R For the diff amplifier with a gain of A D,

Integrator Circuit For the integrator circuit,

Note that the term inside the integral is a constant,

Pneumotachograph Volume Measurement A volume exhaled by a patient is measured with the pneumotachograph by first closing and then opening the reset switch. This sets the initial charge on the capacitor to zero and fixes V out at zero.

The patient is then asked to exhale through the pneumotach mouthpiece. The resulting change in  R creates a voltage V F as a function of time in proportion to flow.

The air volume expired by the patient, beginning at t = 0, when the reset is activated, equals the area under the flow vs. time curve. Mathematically, this area is computed by integration.

The output voltage, V out,is proportional to the volume of air expired from time t = 0 to the time, t, desired. The flow, F, is a function of time that may increase, decrease, or stay constant, so long as it goes in one direction.

This implies that V out is proportional to the total volume of air that is passed through the pneumotach for the time of observation.

THE PLETHYSMOGRAPH The pneumotachograph can be used to measure the rate of airflow during respiration and the vital air capacity of the lung VC. It cannot, however, measure the total lung capacity, TLC.

The reason for this is that the pneumotachograph can only measure the amount of air a person can exchange in respiration, and cannot detect the residual volume of air, RV, left in the lung after a forced exhaling. To measure the TLC, a body plethysmograph may be used.

The plethysmograph consists of an airtight chamber the patient can enter and sit in.

The principle of operation of the plethysmograph depends directly on the gas law for an ideal gas of volume V and pressure P, namely Boyle’s Law where k 1 is a constant and T is the absolute temperature (K). In the chamber, the temperature remains constant.

To measure TLC, the patient enters the chamber. The door is sealed, and the valve on the mouthpiece is closed.

Since the patient cannot breathe with the valve closed, the air pressure in the mouthpiece equals that in the lung, P T. That is, when the flow of air is zero, the pressure drop from mouthpiece to lung is also zero.

With the valve closed, a formula for the thoracic volume is derived as follows. The gas equation for constant temperature holds inside the lung

Using the previous equation, the TLC can be written as:

Boyle’s Law also holds in the chamber, so that Here VOL C is the chamber volume and P C is the chamber pressure.

Because the chamber is closed, any increase in the thoracic volume introduced by breathing motions causes a decrease in the chamber volume of air. That is

Combining the equations with the previous fact:

This yields:

During the test P T = P C approximately, since the changes in pressure induced by breathing motions are small when the patient is resting. Thus,

This equation gives the means for measuring the lung volume, TLC, by the following steps: 1.Close the mouthpiece valve on the patient sealed in the chamber. 2.Ask the patient to make breathing motions. 3.Read the change in pressure dP T on meter 1. 4.Read the change in pressure dP C in the chamber on meter 2. 5.Since the chamber volume VOL C is a known specification of the plethysmograph, use the result in steps 3 and 4 to compute TLC.