Www.oeko.de Challenges for district heating methodologies Worldbank Workshop on CDM Methodologies 5 December 2005 Lambert Schneider.

Slides:



Advertisements
Similar presentations
Antero Punttila Analyzing most typical energy saving measures Energy Efficiency of Steam and Condensate Systems Antero Punttila, Motiva Oy.
Advertisements

Energy Efficient Steam Systems
Demand Response: The Challenges of Integration in a Total Resource Plan Demand Response: The Challenges of Integration in a Total Resource Plan Howard.
Calculating Efficiency Opportunities in Insulation Workgroup Meeting May 2014 Charlie Schreier, PE Engineer.
Energy Efficiency and Intelligent Power Plants Rameshbabu R S 10 th May, 2006 The Center For Bits And Atoms MIT.
University of Liège Faculty of Applied Sciences Thermodynamics Laboratory Workshop “Commissioning and Auditing of Buildings and HVAC Systems” Use of a.
Energy Efficient Steam Systems. Steam Systems Steam systems most widely used type of process heating Advantages of steam: –Heat carrying capacity of steam.
Summary of Heat Loss Calculations Assessing overall heating requirements for building (E) Component U-ValueAreaHeat Loss Rate (W o C -1 ) Walls U walls.
Yuji MIZUNO Institute for Global Environmental Strategies Baseline for Waste Management Project Regional Workshop in Asia on Capacity Development for the.
ww.neprisoe.org CDM Methodologies Carbon Markets – CDM project development 8. August 2011 Jørgen Fenhann.
IAC Student Meeting February 19, 2004 Using DOE BestPractices Steam Tools And Resources Dr. Anthony L. Wright Oak Ridge National Laboratory
Presented by: Terry Stohs Viessmann Manufacturing Company Inc.
Assessment of Climate Change Impacts on Electricity Consumption and Residential Water Use in Cyprus Theodoros Zachariadis Dept. of Environmental Science.
RETScreen® Energy Efficiency Projects
International Climate Policy Case Study Sven Bode Design of JI projects under the Kyoto Protocol to reduce CO 2 emissions December 12/13, 2002, Zagreb.
EPC: baseline adaption. Berliner Energieagentur GmbH EPC: baseline adaption Yearly accounting of energy savings - overview corrected energy costs costs.
POWER GENERATION TECHNOLOGIES
Cogeneration.
CHANGES IN THERMAL ENERGY CONSUMPTION IN APARTMENT BUILDINGS OF ESTONIA Teet-Andrus Kõiv,
Geothermal Energy Chelsey Haske Taryn Mulienburg Jenny Sobecki Taylor Bourne.
Mr. Jiří Spitz ENVIROS, s. r. o., Prague, Czech Republic Phone: Fax: United.
Methodological Issues Arising Across Different Types of Energy Efficiency Projects QualityTonnes Kevin James Montreal December 3, 2005.
Euroheat & Power Why is there not more combined heat and power?
CLIMATE CHANGE AND SME FINANCING 9 – 10 October 2013, Sofia Greenhouse gases emission assessment in SME and Household sectors – current status and tendency.
World Bank Experience with Power Sector Baselines Workshop on CDM Methodologies for Grid-Connected Power Projects Buenos Aires, 8 December 2004 Fernando.
Calculation of Energy Performance of Buildings - Lithuanian Case. Dr
Energy year 2013 District Heat Wilhelms District heat in Finland year 2013  Heat sales (incl. taxes) 2,31 mrd €  Sold heat energy31,7 TWh.
District Heating Technology Improvement of district heating systems efficiency starts at the consumer New calculation tools help consumer and district.
Boilers By: Jason Ng. Objectives Effectively compare and contrast different types of water heating systems in order to enlighten students about proper.
\ ME 200 L32 Today’s Class 8.3 Exams not picked up this week may be recycled! \ ME 200 L32 Utility Power Generation Self Study Assignment 8.2 Today’s Class.
Plant Utility System (TKK-2210) 14/15 Semester 4 Instructor: Rama Oktavian Office Hr.: M-F
Workshop on CDM Methodologies and Technical Issues Associated with Power Generation and Power Saving Project Activities Review of approved and proposed.
DAC PROJECT Capacity Building in Balcan Countries for the Abatement of Greenhouse Gases Setting priorities for GHG emissions’ reduction George Mavrotas.
Technology details, potential and experiences of Trigeneration
Practical Energy Conservation Tips for Steam Propulsion Ships.
Fig08_01 Goal: Want to generate 1000 MW (1x10 6 kJ/s) of Electricity.
September 21, 2005 ICF Consulting RGGI Electricity Sector Modeling Results Updated Reference, RGGI Package and Sensitivities.
UNEP Collaborating Centre on Energy and Environment Rules for Small-Scale CDM Projects Prepared for the CD4CDM Regional Workshop in Tunis January.
Section 3: Energy Use by Sector & Energy Conservation by Fuel Switching Dr. Congxiao Shang Room No.: 01 37P ENV-2D02 (2006):Energy Conservation – power.
Update on methodological work within UNFCCC and future outlook Workshop on CDM Methodologies and Technical Issues 3 rd December, 2005 Montreal, Canada.
Domestic Demand Victoria Roberts February 24 th 2005.
1 Case study: Sofia District Heating Dr. Venkata R. Putti Team Leader, Carbon Finance Assist The World Bank Minsk / Belarus, March 2007.
Energy year 2014 District Heat.
THERMAL POWER PLANT.
Taina Wilhelms Energy year 2011 District Heat.
SmArt management for RenewAble district Heating and cooling systems SARAH Universidad de Valladolid- Cartif (SPAIN) Javier Rey, 2013 ERRIN Brokerage Event.
Case Study: Gemina Rice Husk Project Nicaragua (Scenario Analysis and Small-Scale Simplified Methodologies) Carbon Finance Unit The World Bank 22 October.
DISTRICT HEATING District heating is an infrastructure which allows heat generated in a centralized location to be distributed to residential homes and.
Case study 1 Review comments on Baseline Methodology Waste heat use project Prepared by Nguyen Van Hanh Vietnam.
Public Name: François Bruggemans Dept: New Business - Heating Carbon footprint of heating systems Lowering GHG emissions by the use of heat pumps.
Contract: EIE/07/069/SI Duration: October 2007 – March 2010Version: July 7, 2009 Calculation of the integrated energy performance of buildings.
Conservativeness in baselines WB workshop for CDM project developers Buenos Aires, 5 December 2004 Lambert Schneider.
A Carbon Footprint Calculator for On-campus Students: Development and Education Jeremy Caves Maiella Leano; Jina Lee; Althea Tupper.
New Ecology, Inc. Boston/Hartford/Providence/Baltimore TDA-JCHE Technical Assistance LISC Community of Practice March 2, 2016 Presented by: Andrew Proulx,
EGEE 102 – Energy Conservation And Environmental Protection Energy Efficiency.
The key to comfort and reduced fuel use for all heating and cooling The key to comfort and reduced fuel use for all heating and cooling.
Baseline approaches and methodologies: interpretation of Para 48(a)-(c) M&P Buenos Aires, – December 5 th, 2004 Johannes Heister – World Bank, Carbon Finance.
Energy year 2015 District Heat.
Presentation title Methodological tool and data for the development of a SB for the emission factor of an electricity system CDM Standardized Baselines:
Dominik Franjo Dominković. , I. Bačeković, D. Sveinbjörnsson, A. S
Hyde Park Central School District
Cogeneration Dr. Haider Ali.
Flo-Direct®.
The key to comfort and efficiency for heating and air-conditioning
The key to comfort and efficiency for heating and air-conditioning
Performance of household heat pump and battery
The key to comfort and efficiency for heating and air-conditioning
Flexible space heating demand for district heating systems
District heating in Finland 2017
Energy Management Introduction Rantharu Attanayake BSc. (Eng), MSc, MBA EE – Energy Management Mobile :
Presentation transcript:

Challenges for district heating methodologies Worldbank Workshop on CDM Methodologies 5 December 2005 Lambert Schneider

District heating – methodological challenges 1.Cogeneration is methodologically more complex  Need to consider both: Power and heat 2.District heat network  Heat losses  Pumping power 3.Multiple baseline scenarios for heat generation  Hot water / heating may be generated differently  Different existing heating devices (stoves, boilers)  Determine baseline scenario for different cases (buildings types, areas) 4.Rebound effects  Increased room temperature due to higher comfort with DH, resulting in increased heating demand due to the project activity

Dealing with cogeneration (1) Backpressure plants Backpressure plants: Relation heat / steam is fixed No power generation at the project site in the absence of the project Power may substitute  Average grid OM / BM?  Power in a similar plant w/o cogeneration? Small plants  Assume OM / BM as default for electricity substitution Large plants  Account for ERs associated with energy savings: Assume similar plant (same fuel and technology) w/o cogeneration

Dealing with cogeneration (2) Steam extraction Heat extraction results in a loss of power generation Determine power loss coefficient β  β = marginal loss of power generation per marginal heat extraction  Typical range β = 0.15 – 0.25 Loss of power generation may be substituted by  additional fuel combustion in the cogeneration plant in condensing operation mode (use emission factor of the plant)  power generation in plants at other sites (use BM/OM) Project emissions PE = Heat extracted * β * EF for power

Baseline emissions Calculate baseline emissions on the basis of heat actually supplied by the DH system  Exogenous factors influencing heating demand are factored out (improvements in buildings insulation, climatic variations, etc)  Heat losses of the DH network are automatically considered Estimate efficiency of baseline heat supply systems (ε)  Sample measurements  Conservative default assumptions Estimate rebound effects Baseline emissions BE = Heat supplied / ε * Rebound factor

Quantifying rebound effects Rebound effects are irrelevant where DH substitutes automatic centralized heating systems (boiler) Important: Substitution of individual stoves or electric heating  Not all rooms may be heated  The average temperature in apartments may be considerably lower than with DH systems  Heating demand may be increased due to the project activity Quantification of rebound effects  Heating demand is nearly proportional to room temperature => Base calculation on differences in room temperature  Use historic fuel consumption data and adjust with degree days

Thank you for your attention! Lambert Schneider Öko-Institut phone: