ITER In-Vessel Coils (IVC) Interim Design Review Requirements & Design Point C Neumeyer July 26, 2010 July 26-28, 20101ITER_D_353BL2.

Slides:



Advertisements
Similar presentations
Chapter 12 Transformers. Chapter 12 Transformers.
Advertisements

Chapter 30. Induction and Inductance
Inductors and Chokes In Switch mode Supplies
First Wall Heat Loads Mike Ulrickson November 15, 2014.
During fault behavior of circuit breaker
ITER In-Vessel Coils (IVC) Interim Design Review Integration with Interfacing Systems C Neumeyer July 28, 2010 July 26-28, 20101ITER_D_3M3P5Y.
ASIPP Zhongwei Wang for CFETR Design Team Japan-US Workshop on Fusion Power Plants and Related Advanced Technologies February 26-28, 2013 at Kyoto University.
September 24-25, 2003 HAPL meeting, UW, Madison 1 Armor Configuration & Thermal Analysis 1.Parametric analysis in support of system studies 2.Preliminary.
Magnetic Circuits and Transformers
Alternating Current Circuits
First Wall Thermal Hydraulics Analysis El-Sayed Mogahed Fusion Technology Institute The University of Wisconsin With input from S. Malang, M. Sawan, I.
1 Chapter 27 Current and Resistance. 2 Electric Current Electric current is the rate of flow of charge through some region of space The SI unit of current.
CM-18 June Magnet Conductor Parameters and How They affect Conductor Selection for MICE Magnets Michael Green Lawrence Berkeley Laboratory Berkeley.
WINDING LOSSES IN HIGH FREQUENCY TRANSFORMERS
1 THERMAL & MECHANICAL PRELIMINARY ANALYSIS ELM COIL ALTERNATE DESIGN Interim Review July 26-28, 2010 In-Vessel Coil System Interim Review – July 26-28,
COIL WINDING ISSUES P. Fabbricatore INFN Genova LCD - Magnet 13Oct09 1 Coil winding issues Based on experience acquired with CMS coil construction,
Chapter 29 Electromagnetic Induction and Faraday’s Law
BASIC CONSIDERATIONS IN DESIGN  The aim of the design is to completely obtain the dimensions of all the parts of the machine to furnish the data to the.
Chapter 22 Alternating-Current Circuits and Machines.
Chapter 2 Transformers.
Power Electronics and Drives (Version ) Dr. Zainal Salam, UTM-JB 1 Chapter 3 DC to DC CONVERTER (CHOPPER) General Buck converter Boost converter.
Alternating Current Circuits
ELECTRICAL CIRCUIT ET 201 Define and explain characteristics of sinusoidal wave, phase relationships and phase shifting.
Nov PHYS , Dr. Andrew Brandt PHYS 1444 – Section 003 Lecture #20, Review Part 2 Tues. November Dr. Andrew Brandt HW28 solution.
In Engineering --- Designing a Pneumatic Pump Introduction System characterization Model development –Models 1, 2, 3, 4, 5 & 6 Model analysis –Time domain.
ITER In-Vessel Coils (IVC) Interim Design Review PDR Checklist Items C Neumeyer July 28, 2010 July 26-28, 20101ITER_D_3MAZCX.
Motor Testing (Motor Only)
Inner PF Coil Design Updated C Neumeyer 2/2/10. Changes Since Prior Version Added electrical insulation – Account for 3-wire system ground fault – Account.
ASIPP EAST Overview Of The EAST In Vessel Components Upgraded Presented by Damao Yao.
Possible HTS wire implementation Amalia Ballarino Care HHH Working Meeting LHC beam-beam effects and beam-beam interaction CERN, 28 th August 2008.
NSTX OH Coil Optimization Ali Zolfaghari Amir Salehzadeh.
RFQ Thermal Analysis Scott Lawrie. Vacuum Pump Flange Vacuum Flange Coolant Manifold Cooling Pockets Milled Into Vanes Potentially Bolted Together Tuner.
NSTX_U Design Point Study Active H2O Cooling Pulse Length 60 sec C Neumeyer 5/19/6.
Bias Magnet for the Booster’s 2-nd Harmonic Cavity An attempt to evaluate the scope of work based of the existing RF design of the cavity 9/10/2015I. T.
Bohm 1 Preliminary Neutronics Analysis of 3x2 Toroidal and Poloidal Legs of ELM Coils Tim Bohm and Mohamed Sawan University of Wisconsin 7/22/2010.
Calorimeter Analysis Tasks, July 2014 Revision B January 22, 2015.
NSTX Center Stack Upgrade Workshop Requirements & Design Point C Neumeyer Jan 22, 2009.
ITER In-Vessel Coils (IVC) Interim Design Review Introduction C Neumeyer July 26, 2010 July 26-28, 20101ITER_D_3F7XHR.
Chapter 29 Electromagnetic Induction and Faraday’s Law
The Heavy Ion Fusion Virtual National Laboratory Pulsed Normal Quadrupoles for a Heavy Ion Fusion Driver Final Focus Section D. Shuman, S. S. Yu, LBNL.
Inductance and AC Circuits. Mutual Inductance Self-Inductance Energy Stored in a Magnetic Field LR Circuits LC Circuits and Electromagnetic Oscillations.
Results Conclusion Methods Samples Peak current limiting properties of SFCL with parallel connected coils using two magnetic paths Objectives Background.
February 13, 2012 Mu2e Production Solenoid Design V.V. Kashikhin Workshop on Radiation Effects in Superconducting Magnet Materials (RESMM'12)
ELECTRICAL TECHNOLOGY EET 103/4
ITER In-Vessel Coils (IVC) Interim Design Review Thermal Structural FEA of Feeders A Brooks July 27, 2010 July 26-28, 20101ITER_D_353BL2.
Scoping Study of RWM on NSTX C Neumeyer 2/21/3. Purpose: 1) identify the design issues, 2) develop the design concepts and 3) outline the tasks GA/PPPL.
NCSX NCSX Trim Coil Peer Review 11/6/07 1 Tom Brown Art Brooks Raki Ramakrishnan Mike Kalish NCSX Trim Coil Peer Review.
ESS | A Preliminary Feasibility Assessment of Power Converters and Magnets for Beam Raster System| | Carlos A. Martins, ESS Preliminary Feasibility.
Monday, April 23, PHYS , Spring 2007 Dr. Andrew Brandt PHYS 1444 – Section 004 Lecture #19 Monday, April 23, 2007 Dr. Andrew Brandt Inductance.
JRA on Development of High Temperature SC Link Motivation Work Packages Partners & resources Amalia Ballarino Esgard open meeting CERN,
Mike Struik / LHC-CRI INSTRUMENTATION FEEDTHROUGH SYSTEM FOR LHC MACHINE ARC QUADRUPOLE MAGNETS. 123rd LHC Vacuum Design Meeting 19 April 1999.
1 QXF / SQXF heater design update M. Marchevsky (12/03/13)
E. Todesco, Milano Bicocca January-February 2016 Appendix C: A digression on costs and applications in superconductivity Ezio Todesco European Organization.
EFFECTS OF VOLTAGE IMBALANCE ON 3-PHASE INDUCTION MOTORS DESIGN TEAM 3.
REQUIREMENTS & ASSUMPTIONS C Neumeyer 4/10/3. FIELD AND CURRENT Base GRD requirement: 3kG at R 0 =0.854m with 4.5 sec flat top, once every 300s
NSTX OH Coil Optimization Ali Zolfaghari. Optimization Parameters: Coolant channel diameter –Larger coolant diameter will lead to coil temp above 100°
Tiina Salmi and Antti Stenvall, Tampere University of technology, Finland FCCW2016 Roma, April 13 th, 2016 Quench protection of the 16T dipoles for the.
Study of the HTS Insert Quench Protection M. Sorbi and A. Stenvall 1 HFM-EuCARD, ESAC meeting, WP 7.4.1CEA Saclay 28 feb. 2013,
RAON LEBT Design Yonghwan Kim Institute for Basic Science Yonghwan Kim Institute for Basic Science.
Chapter 9 CAPACITOR.
Chapter 19 Alternating Current Circuits and Electromagnetic Waves.
A Field Construction Technique to Efficiently Model the Dynamic Vector Forces within Induction Machines Dezheng Wu, Steve Pekarek School of Electrical.
PExprt Modeling Procedure
Circuits description and requirements - Closed Session-
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Induction Motor Drives
Chapter 31 Faraday’s Law 31.1 Faraday’s Law of Induction
Quench calculations of the CBM magnet
Power Leads for Test Stands
F.Pasdeloup, H.Prin, L. Williams
Presentation transcript:

ITER In-Vessel Coils (IVC) Interim Design Review Requirements & Design Point C Neumeyer July 26, 2010 July 26-28, 20101ITER_D_353BL2

Requirements System Req’ts Document (SRD) ITER_D_2MFYMW – CDR version approved Sept 2009 – STAC version approved May 2010 – Major revision ongoing Main design-driving requirements – Physical location and envelope – Current and voltage waveforms – Operability in degraded modes July 26-28, 20102ITER_D_353BL2

Requirements - Physical location and envelope Dictated by IO as part of overall in-vessel design integration July 26-28, 20103ITER_D_353BL2

Requirements - Current and voltage waveforms VS based on physics simulation of VDE Physics simulation of minor VDE with Z 0 = 16.5 cm plus noise Engineering interpretation July 26-28, 20104ITER_D_353BL2

Requirements - Current and voltage waveforms VS (con’t) Zoom Synthesized waveform parameters July 26-28, 20105ITER_D_353BL2

Requirements - Current and voltage waveforms VS (con’t) – I noise_rms chosen such that the ∫i 2 (t)dt taken over the 10 sec period for the synthetic waveform equals that for the reference, namely kAt 2 -sec – At frequency of 30Hz the voltage required to drive the noise current is 50% of the maximum voltage. Note that, for sinusoids the rms value is independent of frequency. – Voltage requirement directly specified in physics document = 575V/turn – Freq and # of occurrences per pulse of the waveform shall be ≤0.1 Hz (10 sec period) and three, respectively. – The total number of events shall be < over the lifetime of ITER. Zoom July 26-28, 20106ITER_D_353BL2

Requirements - Current and voltage waveforms ELM – Each ELM coil shall be designed to carry a current of 90kA-turn over a range from continuous DC to 5Hz sinusoidal – The voltage rating of the ELM coil shall be determined based on the required coil current and circuit impedance at 5Hz July 26-28, 20107ITER_D_353BL2

Requirements – Operability in Degraded Modes Because of the difficulty of repair and replacement, the IVCs shall be designed to operate in degraded modes as follows: – In case of an ELM coil failure which compromises its ability to perform its normal electrical function but does not compromise its ability to withstand the in-vessel electromagnetic and vacuum environment, removal of the coil from the tokamak shall not be required – In case of a VS coil failure which compromises the ability of a single turn to perform its normal electrical function but does not compromise that turn’s ability to withstand the in-vessel electromagnetic and vacuum environment, removal of that turn from the tokamak shall not be required, and the remaining turns shall be capable of delivering the full rated current waveforms July 26-28, 20108ITER_D_353BL2

Design Point Selection of conductor technology Selection of conductor geometry and # turns – #turns – Insulation thickness – Conductor and water channel cross sections Electrical characterization Overall characterization at circuit and system levels – electrical – thermal – hydraulic July 26-28, 20109ITER_D_353BL2

Design Point - selection of conductor technology Mineral insulated conductor (MIC) is the chosen solution – Tolerant of radiation environment (~ 170 Gy/s and 3000 MGy) Use of MIC in magnets operating in high radiation fields was pioneered by accelerator community beginning in late 1960’s (e.g. LAMPF, SIN, TRIUMF meson factories) – Decades of experience in radiation fields ~ 10 – 100x the IVC requirement Use of MIC has been/is being considered for various fusion applications – Magnets for various fusion reactor studies (NET, MARS, FED) – Diagnostics for ITER – JT60-SA internal coils Swelling may occur but not an issue in compacted powder with finite void fraction Flux results in Radiation Induced Conductivity (RIC) but fluence is not an issue Radiation Induced Electrical Degradation (RIED) not likely a concern – Tolerant of thermal environment ( Operation 100 ~ 150 o C, bakeout to ~ 240 o C) MIC is typically used in heating elements and fireproof wiring Commercial cables rated for continuous operation at 250 o C, transient operation up to 1000 o C July 26-28, ITER_D_353BL2

Design Point - selection of conductor geometry and # turns Increasing #turns Decreasing #turns Higher voltage (bad for insulation) Thicker insulation (difficult for manufacturing) Lower packing fraction (reduced performance) Longer cooling path length (reduced performance, difficult hydraulics) Higher current (bad for PS and bus bar) Larger conductor (difficult for manufacturing) NOTE: scheme was already developed for VS based on 4 turns with each turn penetrating a port and routed to PS area allowing option to abandon failed turn(s) and operate others - Additional VS turns and bus bars considered highly unattractive, therefore n_VS = 4 # Turns July 26-28, ITER_D_353BL2

Design Point - selection of conductor geometry and # turns Insulation thickness – a complex and critical issue – Electrical breakdown Basic dielectric strength limitation Thermal runaway – Ohmic resistance highly dependant on RIC and operating temperature – Current through insulation depends on resistance and capacitive displacement currents » High frequency chopper power supply may cause substantial AC component – Ohmic heating could cause breakdown due to thermal runaway – Thermal conductivity Removal of nuclear heat deposited on structures – Structural behavior – Ground fault detection Low stray resistance due to RIC and temperature will limit sensitivity detection – Manufacturing feasibility Limited prior experience with large size MIC – Winding feasibility (minimum bend radius) Maintain adequate thickness at bends Starting point: set ELM ~ same thickness as Pyrotenax 500MCM, 600V cable, VS to 2x – Largest commercial product and insulation thickness – Assume processes can be adapted via R&D to produce 2x thickness July 26-28, ITER_D_353BL2

Design Point - selection of conductor geometry and # turns Trade study performed using XL solver – Compute water temperature rise based on ohmic + nuclear heat input to flowing water Neglect film resistance and delta T between water and Cu Assume copper and water properties based on average of T_inlet and T_outlet Manual inputs – Conductor shape (rectangular or circular) – Conductor material (100% IACS Cu, 80% IACS CuCrZr (ELM only)) – # turns – Coolant inlet temperature (100 o C) – Allowable coolant temperature rise (30,40,50 o C) – Allowable water flow rate (4,6,8 m/s) Solver variables – Fraction of overall coil envelope taken by conductor + insulation + jacket – Cooling hole diameter and straight for racetrack (rectangular only) – Coolant flow rate Constraints – Flow rate ≤ allowable – Cooling hole dimension ≤ 2/3 conductor width, height (rectangular) or diameter (circular) Fixed – Coil cross section envelope 128 x 193 mm (ELM), 158 x 173 mm (VS) – Length per turn 10m (ELM), 48m (VS) – 2 turns across width (allowing central “backbone”) – 2mm jacket thickness, 2.5mm insulation thickness (ELM), 5mm thickness (VS) – 96kA-turn continuous and rms ELM), 27kA-turn continous VS* – nuclear heating (over entire coil envelope) 0.5 watt/cc (ELM), 0.2 watt/cc (VS) Optimization criteria – Minimize fraction of coil envelope taken by conductor + insulation + jacket (maximize fraction for structure) July 26-28, ITER_D_353BL2

Design Point - selection of conductor geometry and # turns ELMVS SS OD54 mm59 mm SS ID50 mm55 mm Cu OD45 mm Cu ID30 mm Mineral Insulation thickness 2.5 mm5.0 mm After considering range of options settled on design with common inner Cu conductor size, different insulation thicknesses July 26-28, ITER_D_353BL2

Design Point - selection of conductor geometry and # turns ELM Nominal Alt July 26-28, ITER_D_353BL2

Design Point - selection of conductor geometry and # turns VS Nominal Degraded July 26-28, ITER_D_353BL2

Design point – electrical characterization Electrical – DC bus bar – DC bus bar needs to be sized to determine total circuit impedance – Lengths from feeder terminals to power supply area specified by IO – Utilize conductor cross section of 50 mm x 100 mm with 17.5 mm circular hole similar to the largest cross section made by Luvata* based on their billet limit (250kG) allows for individual sections of 6m length. – Considered two options: 2 parallel conductors per pole with 1 water loop which goes from the PS area through one pole to the VV interface and then back through the other pole to the PS area – set water flow to limit water dT to 10C to limit thermal stresses between the poles in case they are bundled 1 conductor per pole with 2 water loops, one water loop per pole. – set the water flow to limit dT to 25C – additional piping would be needed to return the water to the PS area from the VV interface – Selected first option * July 26-28, ITER_D_353BL2

Design point – electrical characterization ELM DC Bus VS DC Bus July 26-28, ITER_D_353BL2

Design point – electrical characterization Coil and bus bar inductance estimates in XL – ELM Self-inductances of coils and bus bar estimated using analytic formulae from Grover – VS Self-inductances of coils estimated using elliptic integral solutions in XL format Mutual inductances estimated using Maxwell’s coax filament formula Self-inductances of bus bar estimated using analytic formulae from Grover Voltages – ELM V min = I *Z, I=15kA, Z = R+j  L,  =2  f, f=5Hz = 128V Chose 180V to include margin and cover for mutual inductance effects – Confirmed adequate based on full R +  M*dI/dt calculation – VS V is specified based directly in physics requirement – 2.3kV based on same coil geometry but slightly different (higher impedance) bus bar Chose 2.4kV to include margin July 26-28, ITER_D_353BL2

Design point – electrical characterization Electrical summary Notes: 1)Resistance at operating temperature 2)For VS, “coil” values include upper and lower coil in anti-series 3)For ELM, “coil” values are maximum of upper, midplane, and lower coils July 26-28, ITER_D_353BL2

Design Point – electrical characterization Insulation Electrical Stress – Pyrotenax Engr Guide data quotes 5kV AC breakdown voltage Extrapolates to peak electric field (accounting for geometry) = 3kV/mm Can predict breakdown voltage (RT and no radiation field) of ELM and VS geometry – Operating stresses < 100V/mm for ELM 266V/mm for VS (one interleaf), < 150V/mm (two interleaves) – Overall stresses on insulation are close to the guidelines suggested by Vayakis et al for mineral insulated cables used for ITER diagnostics < 100 Gy./sec (peak ELM = 170 Gy/s, should be much less for VS TBD) < 473 o K (max ELM ~ 140 o C = 413 o K during electrical operations, ~ 200 o C = 473 o K during bakeout) < 150V/mm (133V/mm with two VS interleaves and symmetric grounding) – Note that above are peak values and most of the coil conductor sees less flux and voltage July 26-28, ITER_D_353BL2

Design point – circuit and system characterization Power supply information Total system power input, water flow, heat loss, etc. ELM July 26-28, ITER_D_353BL2

Design point – circuit and system characterization Power supply information Total system power input, water flow, heat loss, etc. VS Current waveform specifications July 26-28, ITER_D_353BL2

Issues and Resolution Plan IssueResolutionPre/Post October Change ELM to CuCrZr if req’d by structural/fatigue considerations or other Reconsider optimization of flow, delta T, and cross section based on CuCrZr Pre Erosion issue due to high water flow velocity Reduce 15kA DC continuous requirement to 15kA DC pulsed w/duty cycle spectrum, or switch to CuCrZr, or adopt variable speed pumps Pre Update nuclear heating termObtain more accurate nuclear heating data for both ELM and VS Pre Refine thermal/hydraulic calculations Run transient thermal analysis using FCOOL or equivalentPre Optimization of conductor geometry (copper and jacket) Obtain feedback from R&D prototyping and analysis and determine if adjustments needed Pre Optimization of insulation thickness and VS interleaving Develop better understanding of breakdown, RIC, etc., through literature, gain experience with R&D prototyping and tests, adjust thickness accordingly, possibly use single VS interleaf Pre/Post (tests on proto not avail) Confirmation of SSMIC behavior in radiation field at temperature Perform tests on final proto conductor samples in radiation field, at temperature and voltage Post July 26-28, ITER_D_353BL2

Summary Requirements are defined including traceability to suitable IDM documents SS jacketed Mineral Insulated Cable (SSMIC) is the appropriate technology choice Design point analysis provides coordinated basis for selection of conductor geometry and parameters of interfacing electrical and cooling water systems Design point details are accessible on web site July 26-28, ITER_D_353BL2