TECH TALK - SAE J1772 and OpenEVSE Presented by: Christopher Howell

Slides:



Advertisements
Similar presentations
SAE J1772™ Gery J. Kissel Engineering Specialist General Motors
Advertisements

Design for Prius C Plug-In Conversion
Electric Vehicle Charging
What is Arduino?  Arduino is a ATMEL 168 micro-controller kit designed specially for small projects  User friendly IDE(Integrated Development Environment)
Smart lighting control Done by : Haya Salah Esraa Nabulsi Eman Dwikat Under the supervision of: Dr. Kamil Subhi.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
2014 NEC Code Changes Ted “Smitty” Smith E Light Electric.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Lecture 1: Safety and Protection. 1. A robot may not injure a human being or, through inaction, allow a human being to come to harm. 2. A robot must obey.
Electrical and Computer Engineering iLights Nick Wittemen, EE Chris Merola, EE José Figueroa, EE Matt Ryder, EE Comprehensive Design Review.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
The Association of Electrical and Medical Imaging Equipment Manufacturers Understanding GFCIs Developed by the NEMA 5PP Personnel Protection Technical.
NEPTUNE Power System Low Voltage Circuit Preliminary Design Review Tim McGinnis Dec 4-5, 2003.
© 2011 Ericson Manufacturing, Willoughby, Ohio
Basic Electricity.
Chapter 8 Output Modules.
Pulse Width Modulation (PWM) LED Dimmer Circuit
Pulse Width Modulation (PWM) LED Dimmer Circuit
Chapter 8 Electrical and RF Safety Basic Safety Have a master on/off switch for your station. Don’t work on “live” equipment. Check with a meter first.
Model Continuous Workstation Monitor, Dual Wire ©Copyright 2003 DESCO INDUSTRIES INC.
Electrical Electricity Fuses Relays Solenoids Electrical Testing
Prof. David R. Jackson ECE Dept. Fall 2014 Notes 5 ECE 2317 Applied Electricity and Magnetism Notes prepared by the EM Group University of Houston 1.
Electrical Fundamentals
NFPA ELECTRIC VEHICLE SAFETY FOR EMERGENCY RESPONDERS Module II : Basic Electrical Concepts And Hazards Module II : Basic Electrical Concepts And Hazards.
What to Expect in New Connectors New Connectors are Coming J (AC) CHADEMO (sometimes spelled CHΛdeMO) Protocol with the JARI Connector.
Group Members: -Adam Lint -Chris Cockrell -Dan Hubbard Sponsors: -Dr. Herb Hess -Dr. Brian Johnson HydroFly: Fuel Cell Project.
© 2011 Pearson Education, Inc. All Rights Reserved Automotive Technology, Fifth Edition James Halderman COMPUTER FUNDAMENTALS 71.
MUEV Phase III By: Kevin Jaris & Nathan Golick. Introduction Petroleum is a finite resource. Demand for clean energy is driving the increase in the production.
EPack relaunch. Schneider Electric 2 -Industrial – Eurotherm – 16/12/2015 ●1. Reduce your equipment costs.
CONTENTS: 1.Abstract. 2.Objective. 3.Block diagram. 4.Methodology. 5.Advantages and Disadvantages. 6.Applications. 7.Conclusion.
NEPTUNE Power Low Voltage Circuit Fall 2003 Quarterly Meeting Tim McGinnis Sept 11-12, 2003.
C-12 ELECTRICAL CW3 RIESE 18 APRIL DC SYSTEM -24V, 34 AMP HOUR NICKEL CAD BATTERY A 30V DC STARTER/GENERATORS -AN EXTERNAL DC POWER SYSTEM.
PRESENTATION ON THE TOPIC By: Rahul agarwal. INTRODUCTION  Overload protection circuit are required in inverters and uninterrupted power supplies to.
Computer Fundamentals 14 © 2013 Pearson Higher Education, Inc. Pearson Prentice Hall - Upper Saddle River, NJ Advanced Automotive Electricity and.
Submitted by:.  Project overview  Block diagram  Power supply  Microcontroller  MAX232 & DB9 Connector  Relay  Relay driver  Software requirements.
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
Auto turn off battery charger Auto turn off battery charger.
Electrical Testers Basic test equipment used in today’s shops may include an analog type meter, a VAT (Volt-Amp-Tester), DMM (Digital Multimeter),
Programmable Logic Controller & Distributed Control System Yoon-Je Choi 17 th June 2006.
PROJECT ON FAULT ANALYSIS AND DETECTION GUIDED BY:: SUBMITTED BY:- MS. SHUBRA GOEL.
Series and Parallel Circuits
IR OBSTACLE DETECTION TO
E Control Devices have a wide range of Latching Relays. The range of latching includes Relays, 16 Amp Latching Relays, 30Amp Latching Relays, 80 Amp Latching.
SUBMITTED BY EDGEFX TEAM
EKT 314/4 WEEK 6 : CHAPTER 3 SIGNAL CONDITIONING EKT 314 Electronic instrumentation.
ARDUINO BASED UNDERGROUND CABLE FAULT DETECTION
Circuit Protection Unit 9.
SUBMITTED BY EDGEFX TEAM
ABSTRACT The microcontroller receives the Infrared Signal from the TV remote, the code of which is identified by the IR receiver depending on which it.
Different Types of Relays.
IR OBSTACLE DETECTION TO
Notes 5 ECE 3318 Applied Electricity and Magnetism Fall 2017
GROUND-FAULT GROUND-CHECK MONITOR
Charging Stations.
MICROCONTROLLER BASED LAMP LIFE EXTENDER BY ZVS USING THYRISTOR
ECE 445 Senior Design, Spring 2018
PLC Hardware Components.
Chapter Six Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and.
ELECTRONICS II 3rd SEMESTER ELECTRICAL
Series 5300 Lithium Cell Formation System
(Shock Absorber Tester)
Applications of Basic Electronics Components
EPRI Truck & Bus Meeting SAE Medium and Heavy Duty Vehicle
Automotive Technology Principles, Diagnosis, and Service
Computer Fundamentals
Presentation transcript:

TECH TALK - SAE J1772 and OpenEVSE Presented by: Christopher Howell

Electric Vehicle Supply Equipment SAE J1772 Recommended Practice TECH TALK - SAE J1772 and OpenEVSE Electric Vehicle Supply Equipment SAE J1772 Recommended Practice Open Source Hardware - OpenEVSE Technology Development TMC Connect 2015 | Santa Clara, CA

Electric Vehicle Supply Equipment (EVSE) The EVSE provides several safety features: Smart Power Cord… Power pins not hot until negotiation Graceful start-up/shut-down Ground verification Protection against shock Plug rated for many plug-in /disconnect cycles TMC Connect 2015 | Santa Clara, CA

Safety – SAE J1772, UL 2231-2 and NEC The EVSE provides safety features and verification of critical features: Charge Circuit Interruption Device (CCID) Welded Contact Detection (verification for CCID) Ground Fault Circuit Interrupt (GFCI) GFCI Self Test (verification for GFCI) Pilot Signal Level and Duty Cycle Ground Monitor Interrupter (GMI) verification for ground TMC Connect 2015 | Santa Clara, CA

Electric Vehicle Supply Equipment (EVSE) The J1772 Pilot is a 1khz +12V to -12V square wave, the voltage defines the state. The EV adds resistance pilot to Ground to vary the voltage. The EVSE reads the voltage and changes state accordingly. State Pilot High Pilot Low Frequency EV Description State A +12V N/A DC Not Connected State B +9V -12V 1000hz 2.74k EV Connected (Ready) State C +6V 882 EV Charge State D +3V 246 Vent. Required State E 0V Error State F Unknown/Error TMC Connect 2015 | Santa Clara, CA

6A - 51A 51A - 80A Electric Vehicle Supply Equipment (EVSE) Amp The J1772 Pilot Duty cycle (time ratio high state vs low state) determined the maximum available current. The EVSE sets the duty cycle the EV must comply to original setting or changes to the duty cycle. Amp Duty Cycle 6A 10% 40A 66% 12A 20% 48A 80% 18A 30% 65A 90% 24A 40% 75A 94% 30A 50% 80A 96% 6A - 51A Amps = Duty cycle x 0.6 Duty cycle = Amps / 0.6 51A - 80A Amps = (Duty Cycle - 64) 2.5 Duty cycle = (Amps / 2.5) + 64 TMC Connect 2015 | Santa Clara, CA

OpenEVSE OpenEVSE is a open source Electric Vehicle SAE J1772 Charging Station for DIY builders and OEMs. Hardware, Firmware and documentation fully Open Source (commercial use allowed) Fully supports SAE J1772 Recommended Practice Software adjustable pilot (6A – 80A) Built in GFCI with 20ma trip point Ground verification and Stuck Relay detection Supports all J1772 states including “ventilation required and Diode check” AC L1 – L2 auto-detect current setting for each TMC Connect 2015 | Santa Clara, CA

OpenEVSE MPU OpenEVSE is based on the ATMEL AVR: 8-bit microprocessor 16mhz @ 5v Compatible with Arduino IDE TMC Connect 2015 | Santa Clara, CA

OpenEVSE Pilot The OpenEVSE pilot uses a 1w DC/DC converter to generate +12v and -12v. The Opamp takes the 1khz pilot from the microprocessor 0 – 5v and switched -12v to +12v. The pilot is read by the microprocessor, R5 – R6 – R7 scale the -12v - +12v signal to 0 – 5v. TMC Connect 2015 | Santa Clara, CA

OpenEVSE GFCI GFCI measures the difference of current going in vs. current going out. The circuit “trips” if an imbalance of > 20ma. The output of the fault line is monitored by the microprocessor as an interrupt. A self test loop runs through the coil 5 times to run self test on boot and every time before closing the contactor. TMC Connect 2015 | Santa Clara, CA

OpenEVSE AC Detect 1 2 L L2 H L1 Bad Ground OpenEVSE uses 2 Optical Isolators to detect the presence of voltage on each AC line. A small current is sent from each hot to ground. The AC_Test leads are connected load side to allow welded relay detection as well as GMI and L1/L2 auto-detection. 1 2 L L2 H L1 Bad Ground TMC Connect 2015 | Santa Clara, CA

Temperature Monitoring and Throttling OpenEVSE Temperature Temperature Monitoring and Throttling OpenEVSE monitors internal temperature Ambient and infrared sensors supported over i2c As temperature increases current is reduced by 25% - 50% - 75% - Shutdown Starts throttling at 57°C (135°F) TMC Connect 2015 | Santa Clara, CA

Based on Open Energy Monitor OpenNRG Energy Monitoring Based on Open Energy Monitor OpenEVSE records current, temperature and state OpenNRG records voltage, current and temperature Data fusion with EVSE, EV, utility be obtained from EV WiFi – http://data.openevse.com TMC Connect 2015 | Santa Clara, CA

OpenEVSE Dynamic Current Infrastructure is expensive, Smart EVSEs share a circuit and share load. J1772 allows for dynamic current settings Vehicles with low current requirement of those finished can give capacity to those who need it Example: 8 - 30A EVSE sharing 100A circuit TMC Connect 2015 | Santa Clara, CA

UL listed 80A Dual and Single Liquid Sky - WattZilla WattZilla DUO is the world’s first dual 80-amp electric vehicle charging station capable of charging two electric vehicles at 80 AMPS simultaneously. UL listed 80A Dual and Single Developed with OpenEVSE components and UL listed by Liquid Sky LLC. Stainless Steel Construction - Made in USA - Built to last! TMC Connect 2015 | Santa Clara, CA

TECH TALK - SAE J1772 and OpenEVSE