Top 10 Medical Device Citations

Slides:



Advertisements
Similar presentations
CAPA Best Practices Open Discussion
Advertisements

Device Initiatives FY 2005 Karen A. Coleman FDA Device National Expert.
Radiopharmaceutical Production
Annual Product Review (APR) Product Quality Review (PQR)
SOP Melody Lin, Ph.D. Deputy Director, Office for Human Research Protections Director, International Activities Santiago, Chile August.
EPSON STAMPING ISO REV 1 2/10/2000.
Metric, Data and Analysis Biometrics Ricki A. Chase Director, Investigations Branch
MFRPS Lesson Learned North Carolina
FDA Warning Letter CAPA September 2010 Dr. Guido Heinrichs.
How is the Supply Chain Impacted by the FDA Purchasing Controls Regulatory Requirements? Teresa Jimenez Regulatory Expert Consultants, Inc. Oct. 4, 2012.
Environmental Management Systems An Overview With Practical Applications.
Effective CAPA Program, a Valuable Tool in Quality Improvement Dharmi Trivedi.
U.S. Food and Drug Administration Notice: Archived Document The content in this document is provided on the FDA’s website for reference purposes only.
FIELD COMPLIANCE UPDATE CDR Thomas R. Berry, RPh FDA, Investigator RAL-RP / ATL-DO.
Pre-Market and the QSR Presented by: Dawn Fernandes.
Field Investigators: ADE Detectives. Section One Introduction to the Team and Their Roles.
CDRH Software Regulation
External Defibrillators: Recalls, Inspections, and the Quality System Regulation Melissa Torres Office of Compliance December 15, 2010.
Top Tactics for Maximizing GMP Compliance in Blue Mountain RAM Jake Jacanin, Regional Sales Manager September 18, 2013.
Proposed Rules to Help Ensure the Safety of Imported Food 1.
Five Star Quality Consultants Implementing ISO 9001 Corrective and Preventive Action.
FDA Recalls Risk Communication Advisory Committee David K. Elder Director, Office of Enforcement.
© 2009 Michigan State University licensed under CC-BY-SA, original at Corrective Action.
QSIT Management Controls QSIT Workshops. Management Controls u Importance u Assessment u Demonstration of Compliance.
Regulatory Update Ellen Leinfuss SVP, Life Sciences.
POSTMARKETING ADVERSE DRUG EXPERIENCE INSPECTIONAL PROGRAM CDR Thomas R. Berry, RPh FDA, Investigator RAL-RP / ATL-DO.
Center for Veterinary Medicine (CVM) RECALLS.  21 CFR 7.40 provides guidance on the policy, procedures, and industry responsibilities for recalls. 
The Role of the Internal Auditor for Maintaining System Compliance and Promoting Continuous Improvement Wayne M. Uttke
Food & Drug Law Institute Conference on Products Liability For FDA Regulated Products January 26, 2005 Recalls: The First Smoke of A Mass Tort Overview.
FDA Regulatory review in Minutes: What Product Development Executives Need-to-Know. Specifically, frequent causes of recalls and related areas that investigators.
Inspection Issues in the Analytical Laboratory: An FDA Perspective Yvonne McKnight Chemist US Food and Drug AdministrationPhone: x
Patient Safety and Medical Devices Sonia Swayze, RN, MA, C and Suzanne Rich, RN, MA, CT.
Creating a Risk-Based CAPA Process
Device Clinical Trials and More… Michael E. Marcarelli, PharmD Director, Division of Bioresearch Monitoring Office of Compliance Center for Devices and.
Kimberly A. Trautman FDA’s Medical Device Quality System Expert
Research Studies GOTCHA’S By Sally Duffy. Failure to follow protocol, investigator agreements and regulations Did not use device/drug in manner specified.
Proposed Regulations for Foreign Supplier Verification Programs (FSVPs)
PATRICIA KERBY, MPA HUMAN SUBJECTIONS PROTECTION COMPLIANCE OFFICER OFFICE OF RESEARCH COMPLIANCE What are the FDA’s expectations in 2010?
Latham & Watkins operates as a limited liability partnership worldwide with affiliated limited liability partnerships conducting the practice in the United.
ISO NON-CONFORMANCE, CORRECTIVE AND PREVENTIVE ACTION.
This class cannot be shared or copied without the written permission of PracticeWorks Systems, LLC.
Rules for Supporting Part 803 and Part 806 Decision Making Page 1 Establishing Rules for: Medical Device Reports (803) & Correction and Removal Reports.
Copyright FDA Inspections: Where Do Things Go Wrong? Diana Naser RN, MS, CCRP Executive Director Clinical Research Administration Clinical Research.
Module C FDA Regulations Regulatory Documents Patricia E. Koziol 1Module C Final Version 10-apr-2010.
Joel Gerber Zachary Reaver Kurt Schilling.  Provides physical proof of development  Maintains product design knowledge base  Meets government and corporate.
FDA Regulatory and Compliance Symposium
New England District Update MassMEDIC Conference December 1, 2010 Waltham, MA.
Regulatory Decision Making D. Kathleen Wright, Reviewer Division of Microbiology Office of In Vitro Diagnostic Device Evaluation & Safety ( OIVD ) Food.
The Second Annual Medical Device Regulatory, Reimbursement and Compliance Congress Presented by J. Glenn George Thursday, March 29, 2007 Day II – Track.
FDA job description  Regulates about 25% of all consumer purchases  Mission summary: protect and advance public health  Products: food, cosmetics, drugs,
Checking and Corrective Action EPA Regions 9 & 10 and The Federal Network for Sustainability 2005.
FDA Facility Evaluation Douglas Stearn Deputy Director for Policy and Analysis Office of Compliance Center for Drug Evaluation and Research.
Corrective and Preventive Action
Good Manufacturing Practice (GMP) Compliance: GMPs EXPLAINED.
INTRODUCTION Quality System in Medical Devices ©2014 Salt Lake Community College. All rights reserved.
WORKSHOP ON ACCREDITATION OF BODIES CERTIFYING MEDICAL DEVICES INT MARKET TOPIC 9 CH 8 ISO MEASUREMENT, ANALYSIS AND IMPROVEMENT INTERNAL AUDITS.
Complaint Handling Medical Device Reporting May 19, 2016 Rita Harden, Director Customer Relations & Regulatory Reporting.
Device regulations USA Dr Phil Warner. USA Regulations MEDICAL DEVICES Food, Drug & Cosmetics Act Medical Device Amendments of 1976 (and other things)
November 6, 2013 Purchasing Controls & Supplier Quality Best Practices Beyond Compliance for the Medical Device Industry AdvaMed 2013 Bernie Liebler Technology.
KEVIN BEDAL LISA CARLIN MATT CARROLL ERIN NICHOLS Product Safety & Failure Analysis.
FSMA TRAINING Industry Recall Readiness BEST PRACTICES.

Medical Device Regulatory Essentials: An FDA Division of Cardiovascular Devices Perspective Bram Zuckerman, MD, FACC Director, FDA Division of Cardiovascular.
4.5 Checking and Corrective Action Monitoring and Measurement
Overview of FDA Food Inspections
Design Controls and Production & Process Controls
The Quality System Inspection Technique (QSIT)
FDA Quality System Regulation
Radiopharmaceutical Production
Presentation transcript:

Top 10 Medical Device Citations Regina A. Barrell Food and Drug Administration Office of Regulatory Affairs Office of Enforcement and Import Operations Division of Enforcement Good Afternoon! Source of information: Turbo software system Format for talk: - Describe inspectional approach - Brief description of the top 10 citations for 2011 - Show how top 10 have changed over the past 14 years - Examples of language for the top 5 cites - Overview of all enforcement statistics for 2011

QSIT Approach to Inspections Level 1 – Abbreviated – 2 subsystems; Corrective and Preventive Actions (CAPA) plus Production and Process Controls (P & PC) or Design Controls. Level 1 inspections are used for routine surveillance and initial inspections of all firms, other than Class III manufacturers. Initial inspections of Class II manufacturers are typically conducted used Level 2 inspectional guidance. Primarily for firms that have a previously compliant history: The last inspection did not result in any type of administrative or regulatory action.

QSIT Approach to Inspections Level 2 – Comprehensive – 4 major subsystems; Management Controls, Design Controls, CAPA and P & PC. Level 2 Inspections are more complex or in-depth than Level 1: For all initial inspections of Class III device manufacturers and, where possible, Class II device manufacturers By assignment For foreign inspections For training For Accredited Persons audits (PAC 82845P) When an inspection, which started out as Level 1, reveals post market information and/or objectionable conditions which cannot be adequately assessed as a Level 1 inspection.  (Before converting to this more comprehensive level, district management should be informed.) Where district work plan resources permit (Level 2 should be considered for any inspections of Class II and Class III device manufacturers.  The decision to use Level 2 inspections should be based on risk.) The Level 2 QSIT approach was validated using the following inspectional sequence:  Management Controls, Design Controls, CAPA and P&PC.  This inspectional sequence allows the investigator to review design control issues and how the device specifications were established before reviewing the CAPA subsystem. 

QSIT Approach to Inspections Level 3 – Compliance Follow-Up – Special – For Cause – Special – Risk Based Work Plan - As directed by inspectional guidance and elements of QSIT. Level 3 inspections are Compliance Follow-up Inspections. Level 3 inspections are necessary after a firm is found to have Situation I conditions during a previous QS inspection which was classified Official Action Indicated (OAI).     Level 3 inspections will also be performed when directed by assignment. The QSIT Guide should be used for guidance, but the inspectional guidance provided by the assignment, the district compliance branch, and/or CDRH will guide the flow of the inspection. During domestic Level 3 inspections: (A) Verify that adequate correction(s) and corrective action(s) have been implemented to the quality system problems previously identified; and (B) If the correction(s) and corrective action(s) were not implemented or were not implemented effectively, verify that the deficiencies continue to exist and provide adequate evidence to support a possible regulatory action.  (C) Document any additional quality system problems observed during the inspection, and provide adequate evidence to support a possible regulatory action. 

QSIT Approach to Inspections Compliance Follow-Up, For Cause and Risk Based Work Plan are dictated by the previous FDA-483 findings and other regulatory information and may differ from the typical QSIT approach. Some program areas are considered satellites to the four major quality management system subsystems (Management Controls, Design Controls, CAPA, and P&PC): CAPA Satellites: MDR Corrections & Removals Tracking Thus, MDR, Corrections and Removals, and tracking requirements (where applicable) should be covered when covering the CAPA subsystem. So … why did I bring up the types of inspections to start my talk? One thing that should be clear from the QSIT approach is the importance we’ve placed on CAPA and how it is a major factor in developing the inspectional approach. This emphasis can be seen in the 483 citations revealed in the following slides.

2012 820.100(a) – Corrective and Preventive Action (Procedures) 820.198(a) – Complaint procedures 803.17 – Written MDR procedures 820.100(b) – Corrective and Preventive Action (Documentation) 820.50 – Purchasing Controls These citations were taken from our Turbo database, the database that all inspectional results/reports are entered. Here you see the top five most frequently cited 483 items. Inspectional guidance with regards to how inspections are conducted require our investigators under the Compliance Program, as seen in the last 4 slides, to cover CAPA plus 1 major subsystem (P & PC or Design Controls) for Level 1 (Abbreviated inspections) or all 4 of the major subsystems for a Comprehensive or Level 2 inspection. MDR, Corrections and Removals, and Tracking (where applicable) should be covered when covering the CAPA subsystem. So, the association of why we typically see CAPA and MDR procedures appear in the top 5 citations may in fact be related to the emphasis of our inspectional approach. These are very similar to what we have seen historically in the past – which we’ll review in just a minute The second citation – 820.198(a) deals with the establishment and maintenance of complaint procedures. Although found under the Records Subpart, complaint procedures go hand-in-hand with the CAPA system. The third citation – 803.17 deals with developing, maintaining and implementing written MDR procedures. The fourth citation – 820.100(b) again deals with CAPA, however this time the issue is the lack of documentation of actions taken and not issues with the procedures per se. Finally the fifth citation-820.50 deals with control of purchased products or services. 820.50 had not normally shown up in the top five 483 citations when we look at historical data trends. In the past, it had been down a few slots. We are seeing more and more that this is an area that some firms have not really tightened up with regards to their suppliers. We’ll discuss a little more the importance that purchasing controls play in quality systems, especially as they relate to recalls.

2012 820.75(a) – Process validation 820.90(a) – Control of non-conforming product 820.30 (i) – Design change procedures 820.198 (c) – Complaint investigation 820.181 – Device master record not maintained Citations 6 through 10 reveal a little more variability than the first five items. #6 – 820.75(a) deals with Process Validation #7 – 820.90(a) deals with non-conforming product #8 – 820.30(i) deals with Design Change Procedures #9 – 820.198(c) relates to the failure to investigate complaints . #10 – 820.181 is failure to maintain the device master record.

Total Turbo Citations vs. 2012 Citations 803.17 820.198(a) 3 820.100(b) 4 5 820.75(a) 820.50 As we normally have seen over the last few years, the top 4 -5 citations have been fairly consistent. Here I’ve compared the 2012 citations against the cumulative history of citations – roughly from 1998 – 2012. What’s striking here is that the top 4 citations are fairly consistent. You can see some change in position for MDR procedures (803.17) vs. Complaint procedures (820.198(a)), but overall the rest are pretty stable. Again, 820.100(a) – CAPA procedures is #1, whereas documentation of CAPA activities is #4, and process validation activities and documentation, 820.75(a) – has historically been #5. One new difference for 2012 is the appearance of Purchasing Controls - 820.50 – for the first time in the top five. We’ll discuss this requirement further latter on, especially in the context of device recalls.

Total Turbo Citations vs. 2012 Citations 6 820.22 820.75(a) 7 820.90(a) 8 820.30(i) 9 820.50 820.198(c) 10 820.30(a) 820.181 This graph of the bottom five observations really shows some changes and perhaps a change in the emphasis regarding how inspections are conducted and what our investigators are looking at over this time period. #6 – 820.22 Quality Audit (performance are inadequate or not performed); 820.75(a)Process Validation activities and documentation #7 – 820.22 Quality Audit (procedures have not been established or are inadequate); 820.90(a) procedures not (adequately) established (non-conforming product) #8 - 820.30(i) Design change (procedures); both the same #9 – 820.50 Purchasing controls; 820.198(c) complaint failure investigation #10 –820.30(a) Design control (procedures); 820.181 Device Master Record

TOP FIVE FDA 483 CITATIONS FOR MEDICAL DEVICE FIRMS Number One 21 CFR 820.100(a) Procedures for corrective and preventive action have not been [adequately] established. The next few slides represent the types of citations you may see as written on the 483. I’ve included the first five since these are fairly consistent over all the time period from 1998 - 2012. The first slide here is the stock language that is generated by Turbo “Procedures for corrective and preventive action have not been [adequately] established.” The investigator has the option of using the word “adequately” if the firm has procedures but they are lacking in certain respects. If there are no procedures at all, then the investigator would simply leave out the word “adequately”.

21 CFR 820.100(a) For example: Failure to analyze processes, service records, quality audit reports, complaints, returned product, and other sources of quality data to identify existing and potential causes of nonconforming product; The investigator then has to explain what about the firm’s procedures is lacking.

21 CFR 820.100(a) contd. Cause of nonconformities relating to product, processes and the quality system are not investigated; Actions needed to correct and prevent recurrence of nonconforming product or other quality problems are not identified. Some additional examples you may see written for this …

TOP FIVE FDA 483 CITATIONS FOR MEDICAL DEVICE FIRMS Number Two 21 CFR 820.198(a) Procedures for receiving, reviewing, and evaluating complaints by a formally designated unit have not been [adequately] established. This citation is used where an investigator may have observed that complaints were not addressed readily by a firm – they take an inordinate amount of time to do an investigation into the complaint and it remains open for a long period of time or there is no documentation that the complaint was ever investigated. Finally, this also ties back to 803.17, the firm has no documentation to show that they evaluated a complaint for MDR reportablity and this would be where an investigator would cite the observation.

21 CFR 820.198(a) For example: Complaints are not processed in a uniform or timely manner; are not documented; or have not been evaluated for MDR applicability. Some of the examples you may see under 820.198(a) …

TOP FIVE FDA 483 CITATIONS FOR MEDICAL DEVICE FIRMS Number Three 21 CFR 803.17 Written MDR procedures have not been [developed] [maintained] [implemented]. This one is fairly self-explanatory …

21 CFR 803.17 For example: Your firm’s Complaint Handling procedure states that complaints shall be reviewed for MDR reporting per 21 CFR 803, however there are no additional MDR procedures. An example of the type of citation under 803.17 …

21 CFR 803.17 contd. For example: Your procedure does not contain a standardized process for determining when an event meets the criteria for MDR. There are no instructions for how your firm will evaluate information about an event to make MDR reportability determinations in a timely manner. MDR procedures need to give clear instructions which are used in evaluating events. Sometimes we see fairly generic or general descriptions which really doesn’t meet the intent of the regulation. You need to insure that the procedure is explicit enough for your people to make good decisions.

TOP FIVE FDA 483 CITATIONS FOR MEDICAL DEVICE FIRMS Number Four 21 CFR 820.100(b) Corrective and preventive action activities and/or results have not been [adequately] documented. This citation is fairly straight forward and typically this may be what you would see on a 483, followed by examples of some instances specifically where a firm may have told the investigator they took some remedial action but there was no documented evidence of it. We like to say, “If it’s not documented, it wasn’t done.”

TOP FIVE FDA 483 CITATIONS FOR MEDICAL DEVICE FIRMS Number Five 21 CFR 820.50 Procedures to ensure that all purchased or otherwise received product and services conform to specified requirements have not been [adequately] established. 820.50 contains several subparagraphs that include the requirement to evaluate suppliers, contractors and consultants (820.50(a)) and purchasing data (820.50(b)) to assure that the incoming materials/components or services provided meet required specifications or quality. And the evaluation must be documented, as always.

21 CFR 820.50 For example: Of 11 supplier records reviewed, 4 were not evaluated or included on your firm’s approved supplier list. Here are a few examples you can find from some 483’s….

21 CFR 820.50 contd. For example: Your supplier, which was used to fill ampoules, was disqualified due to quality issues but was left on your approved suppliers list because the supplier was still approved for other services.

FDA Enforcement Statistics Summary Fiscal Year 2012 Seizures 8 Injunctions 17 Warning Letters 4,882 Recall Events 4,075 Recalled Products 9,469 Debarments 20 The next section I thought I would give you a quick overview of the enforcement statistics for 2012 – this slide is for all Centers, not just CDRH. That figure for warning letters - 4,882 – seems rather large but in reality, the majority of those warning letters were issued by our newest Center – Center for Tobacco Products. These letters were issued to retailers for sales of tobacco products to minors

CDRH Enforcement Statistics Summary Fiscal Year 2012 Seizures 1 Injunctions 2 Warning Letters 210 Recall Events 1,190 Recalled Products 2,475 This slide however, is just for CDRH in 2012. Shows the total number of seizures, injunctions, warning letters and recalls taken in 2012 strictly for devices.

CDRH Seizures By Fiscal Year This slide shows the number of device seizures the Agency took from 2007 – 2012. Note: we are missing the data for 2009, I specifically didn’t include it on the slide as I didn’t want to give the impression that the value was zero. For information, the total number of seizures for each of these fiscal years for all Centers: FY ’07 = 6, FY ’08 = 8, FY ’09 = 8, FY ’10 = 10, FY ’11 = 15 and FY ’12 = 8

CDRH Injunctions By Fiscal Year This slide shows the number of device injunctions taken for the same time period – 2007 – 2012. (Again, data for 2009 was missing, so that year was intentionally left off). Again to contrast CDRH vs. All Centers – FY ’07 = 12, FY ’08 = 5, FY ’09 = 11, FY ’10 = 17, FY ’11 = 16 and FY ’12 = 17.

CDRH Warning Letters By Fiscal Year Note that the total number of warning letters has stayed fairly consistent over this time period. The number of inspections however has increased, especially with regards to foreign inspections. So this is somewhat interesting given that fact. To compare CDRH to the rest of the Centers, for FY ’12, CDER = 95, CFSAN = 335, CBER = 20, CVM = 76, CTP = 4,146.

Total Recall Events - CDRH Fiscal Year 2007 - 2012 This slide shows total recalled events by year. There has been upward trend in the total number of recall events from 2007 – 2011 where the number of events almost doubled over this time. The number is 2012 dipped slightly from the 2011 number but still shows a trend upward.

Total Recall Products - CDRH Fiscal Year 2007 - 2012 This slide shows total recalled products by year. Also note that there is a correspondingly upward trend in the total number of products affected by the recalls from 2007 – 2011. The number of products affected almost tripled over this time. However in 2012, we see that the number declined back towards what it was in 2008.

CDRH Recalls – All Classes Fiscal Year 2007 - 2012 This slide shows both recall events and products by year. The Events are in bright blue whereas the products appear in the grey column. This is a combination of the last two slides.

Recalls: Definition of Class I Class I recall: a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death. Next we’ll look at the number of recall events and products by classification. This is the definition of a Class I recall. Class 1 – the most serious classification

CDRH Class I Recalls – Fiscal Year 2007 - 2012 This slide shows the number of Class 1 recalls by events and products. Note that the number of recall events has doubled over this time period, the number of products affected has also increased but fallen back considerably in 2012 from 2011. It is uncertain why there has been an increase in Class 1 medical device recalls over the past few years. The standard of “reasonable probability of serious health consequences or death” has remained the same during this time period. The Center is going back through the old data to understand whether the standard has been upheld consistently or perhaps 10 years ago, we were less likely to classify something as a Class 1 – but the standard has not changed at all. 75% of all recalls fall into Cardiovascular, Chemistry, General Surgery, General Hospital, Orthopedics, and Radiology medical specialty areas. Recently, the most frequently seen recalls involve radiology and cardiovascular devices.

Recalls: Definition of Class II Class II recall: a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. Class II recalls – the classification whereby the majority recalls fall.

CDRH Class II Recalls – Fiscal Year 2007 - 2012 Again this slide shows you Class II events and products by year. Again, you see that the trend is moving upward over time. In 2012, there were roughly twice the number of recall events and recalled products as there were in 2007, although the number both dipped slightly in 2012 from 2011.

Recalls: Definition of Class III Class III recall: a situation in which use of or exposure to a violative product is not likely to cause adverse health consequences. Finally Class III – recall least likely to result in adverse health consequences.

CDRH Class III Recalls – Fiscal Year 2007 - 2012 Finally, Class III recall events and products by year….pretty much the number have stayed fairly steady over this time period

Root-Cause Categories FY 2010 – FY 2012 This chart is for Class 1 recalls - Individual root causes were aggregated for review purposes into broader categories related to: Design (includes device, software, packaging, labeling, process or component design) Change Control (includes component, labeling, vendor, process, packaging, software, or finished device change control) Process control (includes process, packaging process or reprocessing controls) Material/Component (includes nonconforming material, contamination, mix-up, removal or release of material prior to testing) and Packaging/Labeling (includes labeling mix-up, expired dating, labeling false and misleading, or error in labeling) 49% of recalls are related to design control – firms need to go back to 820.30 and see what they can do better in the quality system design controls to better prevent these design control-related recalls. To prevent recalls, need better design validation and better testing up front. Additionally, there has been recent uptick with software-related recalls. Firms struggle with releasing high-quality software. Again, perhaps there needs to be better testing or better validation, and maybe more involvement with clinical people upfront in the design of the software so you get the correct algorithms. The increase in component-related recalls could be due to supplier control issues not being as rigorous as they need to be. Again, going back to our top five 483 citations, we saw that this year “Purchasing Controls” had moved up quite a bit in frequency over what had been seen in years past. This observation may be related to the increased number of component-related recalls.

QUESTIONS??