D. Neff, expts done 7-6-2011 This report shows 2rh window origami (two rhodamine labeled staples/origami). Massud annealed and stored this origami at 4.

Slides:



Advertisements
Similar presentations
Toolkit for testing CCD cameras
Advertisements

Good Practices of Fluorescence Spectroscopy
Introduction to Operation of the XL-30 Scanning Electron Microscope Tutorial # 1 Overview of XL-30 Microscope Control Program.
Rachel Klima (on behalf of the MASCS team) JHU/APL MASCS/VIRS Data Users’ Workshop LPSC 2014, The Woodlands, TX March 17,2014 MASCS/VIRS Data Record Structure.
ABRF meeting 09 Light Microscopy Research Group. Why are there no standards? Imaging was largely an ultrastructure tool Digital imaging only common in.
Sergey Kucheryavski Raman spectroscopy Acquisition, preprocessing and analysis of spectra.
For Tim Corrigan - compilation of some spun on qdots in PVA or PMMA and imaged with either of 3 cameras - Nikon D50, EMCCD, or Leica confocal.
Imaging Science Fundamentals
Status of Oxford Setup Matthew Chalk, Erik Devetak, Johan Fopma, Brian Hawes, Ben Jeffery, Nikhil Kundu, Andrei Nomerotski University of Oxford ( 18 August.
Simple Technique for Suppression of Line Frequency Noise in IR Array Systems Bruce Atwood, Jerry A Mason, and Daniel Pappalardo The Ohio State University.
From CCD to EMCCD Scientific imaging for today’s microscopy.
Charge-Coupled Device (CCD)
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
UVP BioImaging Systems Solutions for the Science of Life Digital CCD Cameras 101.
Update on Armor Simulation Experiments At Dragonfire Facility Farrokh Najmabadi, John Pulsifer, Mark Tillack HAPL Meeting August 8-9, 2006 General Atomic.
Copyright : Marconi Applied Technologies Limited. All Rights Reserved. CCDs for Adaptive Optics CfAO Workshop: Nov 1999 By P.
All origami shown in this report is from the same annealing run that Massud showed in his 6/21/2011 weekly report.
Different sources of noise in EM-CCD cameras
Detecting Electrons: CCD vs Film Practical CryoEM Course July 26, 2005 Christopher Booth.
Live Cell Fluorescence Imaging Presented by: Nicholas Beavers – Media Cybernetics, Inc. Welcome to Sponsored by Starting Soon…
AST3 detector properties
Lab report Anu Norton group 02/10/08. Cleaning of fluorescent contamination on glass substrate Procedure that I followed for cleaning: wash glass beaker,teflon.
[1] Reference: QCam API reference manual document version Charge Coupled Device (CCD)
Douglas Jordan 1, Paul Jorden 1, Claude Carignan 2, Jean-Luc Gach 3, Olivier Hernandez 4 A Novel 4k×4k EMCCD Sensor for Scientific Use 1 e2v technologies.
ISUAL Sprite Imager Electronic Design Stewart Harris.
SPECTRUMSPECTRUMSPECTRUMSPECTRUM  Electromagnetic Spectrum.
500um quartz wafer with nominal 200nm deep aluminum lines – these are aligned with the flat at left and have width of 38um and pitch of 40um with 2um gap.
DIC Differential Interference Contrast Kim Peifley 08/14/15.
Low Light Level CCDs (LLLCCD) A new idea from Marconi (EEV) to reduce or eliminate CCD read-out noise.
Sony Machine Vision Line Up 2014 XCG Line up. XCG Series  VGA ~ 5M  High Quality  VGA ~ 5M  High Quality  High resolution  High Speed  High Sensitivity.
What I Did on My Summer Vacation Olympus IX71 Characterization Substrate Comparison Substrate Cleaning Technique Comparison By: Amelia McCready.
FEMTOSECOND LASER FABRICATION OF MICRO/NANO-STRUCTURES FOR CHEMICAL SENSING AND DETECTION Student: Yukun Han MAE Department Faculty Advisors: Dr. Hai-Lung.
Solar-B SOT/FPP 1 SOT April 2006Ted Tarbell FPP CCD Camera Performance Ted Tarbell 17-Apr-2006.
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
Digital Imaging. Digital image - definition Image = “a two-dimensional function, f(x,y), where x and y are spatial coordinates, and the amplitude of f.
Observation of Bioluminescence in ANTARES J. Brunner.
Development of a Gamma-Ray Beam Profile Monitor for the High-Intensity Gamma-Ray Source Thomas Regier, Department of Physics and Engineering Physics University.
First results from the Biocams J. Brunner. Cameras on floor 1 and floor 5 together with an OM and an ADCP Floor 1 –80m above sea floor Floor 5 –270m above.
IMAGE DATA ACQUISITION
CLS 332 CLINICAL INSTRUMENTAL ANALYSIS. A VISIBLE ABSORPTION SPECTROMETER.
Sensor testing and validation plans for Phase-1 and Ultimate IPHC_HFT 06/15/ LG1.
Quiz (2/20/08, Chpt 3, ECB) 1. A chemical process where there is a net gain of electrons is called _______________. A chemical process where there is a.
Physics 114: Lecture 8 Measuring Noise in Real Data Dale E. Gary NJIT Physics Department.
1 Correct Sampling. What is SAMPLING? Intensity [a.u.] X [µm] 1.
Robo-AO Overview: System, capabilities, performance Christoph Baranec (PI)
The InGaAs IR Array of Chunghwa Telecom Laboratory Chueh-Jen Lin and Shiang-Yu Wang, Optics and Infrared Laboratory In 2006, Advanced Technology Laboratory.
In Video, the shutter remains set Shutter Speed – amount of time the camera shutter is open during the exposure of one frame. (Standard – 1/50 sec.
Quality-evaluation of Cesium Iodide photocathodes for the ALICE/High Momentum Particle Identification detector by means of a VUV-Scanner system Herbert.
Use Snell’s law to determine the angle of total internal reflection in the coverslip (without oil). Oil immersion objectives More light (no total internal.
Date of download: 5/27/2016 Copyright © 2016 SPIE. All rights reserved. (a) Detail of the chip reflectance spectra measured by TM polarized light at 5.
Cyclone System Overview How it works Applications Features & Benefits.
Tools of the Biologist Simple Microscope- Magnifying glass Light Microscope- Using light to produce an enlarged view of the object Magnification- The ratio.
Digital Cameras in Microscopy Kurt Thorn Nikon Imaging QB3/UCSF.
1 Setting Laser Power and PMT Gain Begin with laser power at 20% Set PMT gain to 6.00.
Outline Sample preparation Instrument setting Data acquisition Imaging software Spring 2009AFM Lab.
Topic Report Photodetector and CCD
Bioanalytik detect and identify Over 25 years experience in Imaging Benefits of NightOWL.
1 Topic Report Photodetector and CCD Tuan-Shu Ho.
ISUAL Imager Stewart Harris.
In Video, the shutter remains set Shutter Speed – amount of time the camera shutter is open during the exposure of one frame. (Standard – 1/50.
Astronomy 920 Commissioning of the Prime Focus Imaging Spectrograph
Single Photon Emission Tomography
Volume 84, Issue 6, Pages (June 2003)
György Vereb, Elizabeth Jares-Erijman, Paul R. Selvin, Thomas M. Jovin 
BESIII EMC electronics
Announcements HR Diagram lab will be extended for one week. I’ll talk about it today. Homework: Chapter 9 # 1, 2 & 3 Next week is a Dark Sky Night. If.
Electrophoresis: Movement of a solid phase with respect to a liquid (buffer) Sample is applied to the medium and under the effect of electric field, group.
Volume 93, Issue 9, Pages (November 2007)
Michael Blanchard Imaging Technician
Michael Blanchard Imaging Technician
Presentation transcript:

D. Neff, expts done This report shows 2rh window origami (two rhodamine labeled staples/origami). Massud annealed and stored this origami at 4 deg. C for ~ 1 week before dialysis and deposition shown here.

this annealing run was dialyzed before imaging through a 25nm pore membrane against 1x TAE buffer (30 mins) I am unsure of the staple:plasmid:rhodamine ratios used in origami synthesis all images taken with the ixon3 (photon count capable) CCD and TM AFM AFM and fluor. images are of the very same coverslip, AFM was NOT on fluor microscope stage for spot analysis 9 pixels per spot (a 3x3 pixel area around the spot center) were averaged each frame background plots look smoother because many more pixels were averaged than for spot (point source) analysis

Preparing 2-rhodamine labeled DNA origami sample for fluorescence microscope (Neff proceedure ) Clean glass coverslip Make light scratch on one side of glass coverslip with diamond scribe Sonicate in ethanol for 15 minutes Rinse with UV-treated ddH 2 O and dry with N 2 Irradiate with UV light for 10 minutes Place 1 µL of 2-rhodamine labeled origami and 9µL UV-treated ddH 2 O on coverslip (may have to adjust amount of origami depending on concentration but make sure you have a total of 10µL of liquid) Let stand at room temperature for 10 minutes Rinse coverslip one time with UV-treated ddH 2 O and dry with N 2 Image using fluorescence microscope. Filter set 2 ex max 560, em max Hg lamp 100x oil objective pixel = 129nm imaging params with ixon3 are indicated beside images Preparing 2-rhodamine labeled DNA origami sample for fluorescence microscope (Dawn's original) Clean glass coverslip 1.Make light scratch on one side of glass coverslip with diamond scribe 2.Sonicate in ethanol for 15 minutes 3.Rinse with UV-treated ddH 2 O and dry with N 2 4.Irradiate with UV light for 10 minutes Place 1 µL of 2-rhodamine labeled origami and 9µL UV-treated ddH 2 O on coverslip (may have to adjust amount of origami depending on concentration but make sure you have a total of 10µL of liquid) Let stand at room temperature for 10 minutes Rinse coverslip with UV-treated ddH 2 O and dry with N 2 Image using fluorescence microscope. 1.Filter set x oil objective 3.100msec exposure time and EM gain of 2500 for the Roleramgi camera

33 um total 1090 um 2 48 point sources so here there are ~1 origami / 23um 2 display counts of um time.150 seconds time 180 seconds Filename: 150ms-50em-256x256center.sif Date and Time: Wed Jul 06 16:48: Software Version: Temperature (C): -75 Model: DU897_BV Data Type: Counts Acquisition Mode: Frame Transfer Trigger Mode: Internal Exposure Time (secs): 0.15 Cycle Time (secs): Frequency (Hz): Frame Transfer Mode: Kinetics Number in Series: 1200 Readout Mode: Image {left,right,bottom,top}: 128,383,128,383 Horizontal Binning: 1 Vertical Binning: 1 Horizontally flipped: false Vertically flipped: false Clockwise rotation: false Anti-Clockwise rotation: false Vertical Shift Speed (usecs): 0.5 Pixel Readout Rate (MHz): 10 Baseline offset: 0 Number of prescans: 0 Baseline Clamp: ON Clock Amplitude: Normal Output Amplifier: Electron Multiplying EM Gain level: 50 Serial Number: 5762 Pre-Amplifier Gain: 5 SR163: Wavelength (nm): 500 Grating Groove Density (l/mm):200 Count Convert Mode: Counts Spurious Noise Filter Mode: No Filter Photon counted: false Data Averaging Filter Mode: No Filter

plots for spots indicated in last slide (150ms-50em-256x256center.tif)

first 75 seconds of same plot as last slide (150ms-50em-256x256center.tif)

total 384 um 2 13 point sources so here there are ~1 origami / 30um 2 24 um 16 um display photons of time.120 seconds time 40 seconds 16 um Filename: 120ms-100em.tif Date and Time: Wed Jul 06 16:42: Software Version: Temperature (C): -75 Model: DU897_BV Data Type: Not available Acquisition Mode: Frame Transfer Trigger Mode: Internal Exposure Time (secs): 0.12 Cycle Time (secs): Frequency (Hz): Frame Transfer Mode: Kinetics Number in Series: 330 Readout Mode: Full Resolution Image Horizontal Binning: 1 Vertical Binning: 1 Horizontally flipped: false Vertically flipped: false Clockwise rotation: false Anti-Clockwise rotation: false Vertical Shift Speed (usecs): 0.5 Pixel Readout Rate (MHz): 10 Baseline offset: 0 Number of prescans: 0 Baseline Clamp: ON Clock Amplitude: Normal Output Amplifier: Electron Multiplying EM Gain level: 100 Serial Number: 5762 Pre-Amplifier Gain: 5 SR163: Wavelength (nm): 500 Grating Groove Density (l/mm):200 Count Convert Mode: Photons Sensitivity: Detection Wavelength (nm): 630 Spurious Noise Filter Mode: No Filter Photon counted: false Data Averaging Filter Mode: No Filter background

plots for spots indicated in last slide (120ms-100em.tif)

total area in these 3 scans; 49 um um um 2 =149um 2 total # origami in this area = 11 so we see about one origami / 15um 2 AFM of same coverslip as preceeding slides