Features: Easy to use data collector 2 channels simultaneous sampling & display On-site 400-lines FFT spectrum and waveform display; Transfer function.

Slides:



Advertisements
Similar presentations
S o f t w a r e D e f i n e d R a d i o
Advertisements

AK500N THE ULTIMATE MQS NETWORK AUDIO PLAYER.
THS3000 Product Introduction Market Dynamics  Customers require more flexible solutions  Many test solutions are driven by both measurement needs.
Quickfilter Pro Software Demonstration for QF4A512 The following slides will illustrate how you can design and verify a filter design in minutes! BEGIN.
Workshop 7 of 7 Welcome!. Today's Topics Data Acquisition MAX DAQ Assistant Express VI DAQmx API Create Task Configure Task Configure Trigger Start Task.
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
EE 5340, SMU Electrical Engineering Department, © Carlos E. Davila, Electrical Engineering Dept. Southern Methodist University slides can be viewed.
Tachometers – An Overview
Oscilloscope Watch Teardown. Agenda History and General overview Hardware design: – Block diagram and general overview – Choice of the microcontroller.
MTE´s Portable Product Portfolio
Analog Data Processing with BioProc3 Part Two EMG Analysis Techniques.
Contents 1 GeoDAS, GeoDAS Software of GeoSIG.
Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 OHT 5.1 Signals and Data Transmission  Introduction  Analogue Signals  Digital.
Spectrum analyser basics Spectrum analyser basics 1.
2250 FFT Narrowband Zooming Frequency Analyzer Application BZ7230 Getting the details.
Spectrum Analyzer. Another Oscilloscope??? Like an oscilloscope Oscilloscope in time domain Spectrum analyzer in frequency domain (selectable)
EE 198 B Senior Design Project. Spectrum Analyzer.
Self-Induction Transducers ~ AC Supply v ref Inductance Measuring Circuit x (Measurand) Ferromagnetic Target Object Coil is activated by the supply and.
Typical Steps of field Balancing Illustration with model 907
Magnitude and Phase Measurements
Introduction to the FONIX 7000 Hearing Aid Test System Software version 1.60.
The Function Generator and the Oscilloscope Dr. Len Trombetta 1 ECE 2100.
Vibration & Temperature Sensor. Contents ■ Why monitor vibration? ■ Monitor a wide range of machines ■ Vibration measurements ■ Set alarm levels ■ Mounting.
Metra Mess- und Frequenztechnik Radebeul / Germany Piezoelectric Accelerometers Theory & Application.
Technical Data Electric engine, reduction belt and complete electronics only 5kg Paramotor weight without batteries: 12,5kg One-piece easy assemble (kit.
Handheld Spectrum Analyzer R&S FSH
.
Long Range Pinger Detector PD1102 This presentation describes the function and the technical data of the PD1102 pinger detector amplifier www. etec.dk.
Ni.com Data Analysis: Time and Frequency Domain. ni.com Typical Data Acquisition System.
TPS2000 Series Oscilloscopes Powerful productivity from bench to field Features Featuring:  100 MHz and 200 MHz models  2 or 4 isolated analog channels.
FG Wilson Access 4000 Control Panel
Physics 145 Introduction to Experimental Physics I Instructor: Karine Chesnel Office: N319 ESC Tel: Office hours: on appointment.
Janus Convertible Line – interactive Series UPS
Vibration Data Collector 911D - Economic, Very-easy-to-use Features: Full automatic measurement Automatic diagnosis of machinery faults by time domain.
Distributor URL here  TDS2000 and TDS1000 Series Digital Storage Oscilloscopes Colorful Performance at a Black and White Price Power and precision: with.
TDS 210 BASIC INSTRUCTIONS. Measure 1. Push the MEASURE button to access the automated measurement. 2. capabilities. There are five measurements available.
What it does ? Continuously monitors critical industrial machinery providing information concerning wear and tear as well as the early warning of forthcoming.
Prepared by: Marimuthu Gurusamy Combined vibration analysis (velocity and acceleration envelope) for Prediction of rotating equipment (with rolling element.
TDS2000C Series Oscilloscopes Performance you need at a price you can afford Featuring:  50 MHz to 200 MHz models  2 or 4 analog channels  Up to 2 GS/s.
Power Control System for a Concrete Durability Test Cabinet – Phase 2 Jacob Jameson Madhav Kothapalli Thomas Persinger Andrew Versluys.
IN PARTNERSHIP WITH EVRIKA. IN PARTNERSHIP WITH EVRIKA.
SCAD 508 Strain Measurement System Click Here To Download Complete Information On SCAD Products EXCITATION VOLTAGESelectable from 0.5VDC to 10 VDC in steps.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
TDS3000C Series Oscilloscopes Fact Sheet Performance you need at a price you can afford Features Featuring:  100 MHz, 300 MHz, 500 MHz models  2 or 4.
PRESENTS FALCON A NEW GENERATION IN CONDITION MONITORING.
V.C. - CERN 22/04/021 AUTOMATIC WIRING MACHINE INFN FERRARA STATUS REPORT.
New Features on the FONIX FP35 Hearing Aid Analyzer
Vibration & Temperature Sensor. Contents ■ Why monitor vibration? ■ Health degradation curve ■ Predictive maintenance monitoring ■ Monitor a wide range.
650 VA Power Tree UPS 650VA 100% Stabilized Output Power
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
The labjack. WHAT IS A LABJACK? An interface box that allows a computer to interact with the real world by collecting data and passing out instructions.
Final Year Project Eoin Culhane. MIDI Guitar Guitar with 6 outputs 1 output for each string Each individual string output will be converted to MIDI.
아이알브이테크 1 IRV-TECH 아이알브이테크 May 12, 2015 IRV-65B Light Source.
A Labview based system for condition monitoring of a dry vacuum pump using AR Modelling Techniques Figure 1 – Vibration signals acquired from the pump.
The Function Generator and the Oscilloscope Dr. Len Trombetta and Dr. Dave Shattuck 1 ECE 2100.
© 2007 Data Physics Corporation Data Physics Corporation An Introduction.
SUPERHETERODYNE SPECTRUM ANALYZER. TOPICS Superheterodyne spectrum analyzer – Basic architecture – Frequency resolution – Sweep time – Video section.
Intellectual Insulation Indicator «3i»
DIGITAL SIGNAL PROCESSOR LNR-26 [LINEA RESEARCH]
Powerful Performance from Bench to Field
explosion-proof system for vibration monitoring and 4-plane balancing
I/O INTERFACE DL 231 MIDAS NAME MODEL 제조사
AT-2040 Vibration Sensor test Set.
품 목: SPEAKER PROCESSOR DSP 모델명: NEXIA SP 제조사: BIAMP
Vibration Monitoring System M14
Cableless seismograph Atom
Cableless Seismograph Atom for engineering site investigation
EEG Probe Project Grant G. Connell.
ABC Wireless Vibration Meter
Measurement of Motion.
Presentation transcript:

Features: Easy to use data collector 2 channels simultaneous sampling & display On-site 400-lines FFT spectrum and waveform display; Transfer function analysis; Data storage: point time waveforms and 240 data sets Acceleration envelope demodulation for rolling bearing and gear-box diagnosis On-site spectrum comparison function Inner or external trigger selectable Full featured 1 and 2-planes field balancing (10 sets balancing data storage; balancing process clarified by vector graph; trial weight estimation; can remain or remove trial after balancing; balancing weight decomposition) Balancing report automatic generation. 907 is the same instrument but without communication port for computer nor the software capability. 2-Channel Data Collector/Analyzer/Balancer 904

Sensors connecting Data Collector Screen & Menu Setting Menu Spectrum with cursor Reading P0##…………. Channel: Single A 100 Spectrum: VEL Freq 850 OLD 8 New 7 0 Freq.(Hz) 1000 mm/s 904D Pack List 904 Vibration Data Collector 1 Accelerometer 2 Magnetic Mount 2 Steel Extension Probe 1 Battery Charger 1 Accelerometer Cable 3 RS232c Communication Cable 1 Balancing Module 1 Tacho/Trigger Sensor and cable 1 Reflector Paper set 1 Quick Start Guide 1 MCMe2 Software CD 1 MCMe3 Software (Optional) SDES Software (Optional) Certificates of 904D and sensors 3 Carrying Case 1

Specifications: ·Input signal: accelerometer and voltage, 2 channels ·Amplitude ranges & Frequency Response of overall measurement: Displacement – 5 mm peak-peak Hz Velocity mm/s true RMS Hz Acceleration m/s 2 peak Hz Acceleration Envelope m/s 2 true RMS Hz from KHz Voltage V peak-peak Hz ·Amplitude spectrum analysis: 100 and 400 Lines, hanning windowed ·Frequency span of spectrum analysis: 100, 200, 500, 1k, 2k, 5k, 10kHz(1 channel only) ·Data storage: points time waveforms and 240 data sets ·Notepad: 10 condition codes for visual inspection ·Output: RS232C for communication with PC ·Power: Ni-MH rechargeable battery for 8 hours continuous operation, low battery voltage warning ·Operating Environment: 0 ~ 50 Celsius degree, 90% humidity non-condensing ·Rotating speed measurement range(with laser-aimed tacho sensor): r/min ·Dynamic Range: 60dB with 48dB gain range ·Gain adjustment: both automatic-adjustment or manual- adjustment selectable ·Anti-aliasing filter: 8th order elliptic low-pass ·Dimensions: 21×13×4 cm;weight: 1.2 kg Balancing Process: