Francisco Salesa Greus IFIC (CSIC–Universitat de València, Spain) Representing the KM3NeT Consortium 4 th International Workshop on Very Large Volume Neutrino.

Slides:



Advertisements
Similar presentations
R.Shanidze, B. Herold, Th. Seitz ECAP, University of Erlangen (for the KM3NeT consortium) 15 October 2009 Athens, Greece Study of data filtering algorithms.
Advertisements

Trigger issues for KM3NeT the large scale underwater neutrino telescope the project objectives design aspects from the KM3NeT TDR trigger issues outlook.
Using HOURS to evaluate KM3NeT designs A.Leisos, A. G. Tsirigotis, S.E.Tzamarias In the framework of the KM3NeT Design Study VLVnT Athens, 15 October.
Kay Graf University of Erlangen for the ANTARES Collaboration 13th Lomonosov Conference on Elementary Particle Physics Moscow, August 23 – 29, 2007 Acoustic.
Status of the ANTARES Neutrino-Telescope Alexander Kappes Physics Institute University Erlangen-Nuremberg for the ANTARES Collaboration WIN´05, 6.–11.
Transmission length measurements: a “multi- wavelength” analysis from the OB data H Yepes IFIC (CSIC – Universitat de València) ANTARES Collaboration Meeting.
H Yepes, C Bigongiari, J Zuñiga, JdD Zornoza IFIC (CSIC - Universidad de Valencia) NEWS ON ABSORPTION LENGTH MEASUREMENT WITH THE OB SYSTEM ANTARES COLLABORATION.
Calibration of the 10inch PMT for IceCube Experiment 03UM1106 Kazuhiro Fujimoto A thesis submitted in partial fulfillment of the requirements of the degree.
AN UPDATE ON ABSORPTION LENGTH MEASUREMENT WITH THE OB SYSTEM ANTARES Collaboration Meeting Paris (France), September 20th-24th H Yepes, J Barrios IFIC.
SUSY06, June 14th, The IceCube Neutrino Telescope and its capability to search for EHE neutrinos Shigeru Yoshida The Chiba University (for the IceCube.
Energy Reconstruction Algorithms for the ANTARES Neutrino Telescope J.D. Zornoza 1, A. Romeyer 2, R. Bruijn 3 on Behalf of the ANTARES Collaboration 1.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
STATUS OF THE ABSORPTION LENGTH MEASUREMENT ANTARES collaboration meeting Clermont-Ferrand (France), May 17th-20th 1 H Yepes, JdD Zornoza, J Zuñiga, C.
AN UPDATE ON ABSORPTION LENGTH MEASUREMENT WITH THE OB SYSTEM ANTARES Collaboration Meeting Paris (France), September 20th-24th H Yepes, J Barrios IFIC.
The ANTARES Neutrino Telescope Mieke Bouwhuis 27/03/2006.
J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.
Measurement of the absolute efficiency,
S. E. Tzamarias The project is co-funded by the European Social Fund & National Resources EPEAEK-II (PYTHAGORAS) KM3Net Kick-off Meeting, Erlangen-Nuremberg,
The ANTARES experiment is currently the largest underwater neutrino telescope and is taking high quality data since Sea water is used as the detection.
VLVnT 09 – Vladimir Zhukov 4-th International Workshop on Very Large Volume Neutrino Telescopes for the Mediterranean Sea LIGHT TRANSMISSION MEASUREMENTS.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Catania VLVnT09 Athens, Greece 1/14 Catania Performances of four super bialkali large area photomultipliers with respect to.
Search for point sources of cosmic neutrinos with ANTARES J. P. Gómez-González IFIC (CSIC-Universitat de València) The ANTARES.
Hanoi, Aug. 6-12, 2006 Pascal Vernin 1 Antares Status report P.Vernin CEA Saclay, Dapnia On behalf of the Antares collaboration P.Vernin
Coincidence analysis in ANTARES: Potassium-40 and muons  Brief overview of ANTARES experiment  Potassium-40 calibration technique  Adjacent floor coincidences.
AN UPDATE ON ABSORPTION LENGTH MEASUREMENT WITH THE OB SYSTEM ANTARES Collaboration Meeting Paris (France), September 20th-24th H Yepes, J Zuñiga IFIC.
Piera Sapienza – VLVNT Workshop, 5-8 october 2003, Amsterdam Introduction and framework Simulation of atmospheric  (HEMAS and MUSIC) Response of a km.
V.Bertin CPPM / ANTARES Coll. - Moriond ANTARES : A deep-sea 0.1 km² neutrino telescope Vincent Bertin - CPPM-Marseille on behalf of the Antares.
Amsterdam 29 March 2011 Fernando Urbano IFIC (CSIC – Universidad de Valencia) KM3NeT Optical Calibration Laser Beacon and Nanobeacon Status.
First data of ANTARES neutrino telescope Francisco Salesa Greus IFIC (CSIC–Universitat de València, Spain) On behalf of the ANTARES collaboration The 3rd.
Neutrino Diffuse Fluxes in KM3NeT Rezo Shanidze, Thomas Seitz ECAP, University of Erlangen (for the KM3NeT consortium) 15 October 2009 Athens, Greece.
Calibration Methods and Tools for KM3NeT V. Kulikovskiy on behalf of the KM3NeT collaboration.
The ANTARES neutrino telescope is located on the bottom of the Mediterranean Sea, 40 km off the French coast. The detector is installed at a depth of 2.5.
NESTOR SIMULATION TOOLS AND METHODS Antonis Leisos Hellenic Open University Vlvnt Workhop.
KM3NeT Pylos meeting, April, 2007 Some preliminary studies for the positioning calibration of KM3NeT Miguel Ardid Universitat Politècnica de València.
Acoustic Calibration for the KM3NeT Pre-Production Module Alexander Enzenhöfer on behalf of the KM3NeT consortium VLV T 2011 Erlangen, –
CEA DSM Irfu Reconstruction and analysis of ANTARES 5 line data Niccolò Cottini on behalf of the ANTARES Collaboration XX th Rencontres de Blois 21 / 05.
The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.
The ANTARES Project Sino-French workshop on the Dark Universe Stephanie Escoffier Centre de Physique des Particules de Marseille On behalf of the ANTARES.
Time over Threshold electronics for an underwater neutrino telescope G. Bourlis, A.G.Tsirigotis, S.E.Tzamarias Physics Laboratory, School of Science and.
Time calibration system for the KM3NeT deep sea neutrino telescope S. Toscano, IFIC (Instituto de Física Corpuscular)
Time Calibration with Optical Beacons Pylos, Apr 2007 C.Bigongiari IFIC Pylos, Apr 2007 C.Bigongiari IFIC (CSIC – Universitat de València)
Ciro Bigongiari, Salvatore Mangano Results of the optical properties of sea water with the OB system.
R. Coniglione, VLVnT08, Toulon April ‘08 KM3NeT: optimization studies for a cubic kilometer neutrino detector R. Coniglione P. Sapienza Istituto.
Time Calibration of the ANTARES Neutrino Telescope 2 nd International Conference on Technology and Instrumentation in Particle Physics 08 – 14 June 2011.
Sebastian Kuch, Rezo Shanidze Preliminary Studies of the KM3NeT Physics Sensitivity KM3NeT Collaboration Meeting Pylos, Greece, April 2007.
Time and amplitude calibration of the Baikal-GVD neutrino telescope Vladimir Aynutdinov, Bair Shaybonov for Baikal collaboration S Vladimir Aynutdinov,
PMT measurements in Antares Oleg Kalekin on behalf of Antares collaboration VLVnT 2011 Erlangen
ANTARES Status report  Experiment overview  Status of construction  Status of operation  Status of physics analyses Presentation at ICATPP’07. Oct.
Calibration of Under Water Neutrino Telescope ANTARES Garabed HALLADJIAN October 15 th, 2008 GDR Neutrino, CPPM, Marseille.
1 Ciro Bigongiari, Salvatore Mangano Results of the optical properties of sea water with the OB system.
Simona Toscano In the frame of KM3NeT consortium VLV T workshop - Toulon, April 2008.
Isabella Amore VLV T08, Toulon, France April 2008 International Workshop on a Very Large Volume Neutrino Telescope for the Mediterranean Sea Results.
Status and Perspectives of the BAIKAL-GVD Project Zh.-A. Dzhilkibaev, INR (Moscow), for the Baikal Collaboration for the Baikal Collaboration September.
M. Circella, INFN Bari Time-calibration in NEMO VLVnT08 Time calibration in NEMO M. Circella, INFN Bari Time calibration The NEMO Phase 1&2 towers Time.
Umberto Emanuele IFIC (CSIC-UV), Valencia (Spain) Status of Time Calibration System forKM3NeT.
KM3NeT Optical Calibration Umberto Emanuele IFIC (CSIC – University of Valencia, Spain) WPF/L KM3NeT Meeting Nikhef 5 th - 7 th July
Marseille 29 January 2013 Diego Real IFIC (CSIC – Universidad de Valencia) Instrumentation for Optical Calibration: Laser Beacon and Nanobeacon.
Optical calibration from ten to hundreds of meters for the Neutrino Burst Experiment (a poor man’s Km 3 underwater neutrino telescope) NESTOR/NOA Spyridon.
The prototype string for the km3 scale Baikal neutrino telescope VLVnT April 2008 Vladimir Aynutdinov, INR RAS for the Baikal Collaboration for.
KM3NeT P.Kooijman Universities of Amsterdam & Utrecht for the consortium.
White Rabbit in KM3NeT Mieke Bouwhuis NIKHEF 9th White Rabbit Workshop
Measurement of water optical properties in ANTARES
TDR of PMT: Timing issues
ANTARES time calibration
Instrumentation for Colliding Beam Physics 2017
on behalf of the NEMO Collaboration
Department of Physics and Astronomy,
ICRC2011, 32ND INTERNATIONAL COSMIC RAY CONFERENCE, BEIJING 2011
Nanobeacon: A low cost calibration instrument for KM3NeT
Presentation transcript:

Francisco Salesa Greus IFIC (CSIC–Universitat de València, Spain) Representing the KM3NeT Consortium 4 th International Workshop on Very Large Volume Neutrino Telescopes for the Mediterranean Sea (VLVnT09) Athens, Greece, October 2009

The future KM3NeT detector. Time calibration requirements. Time calibration systems for KM3NeT: – Laboratory calibration. – Internal clock calibration. – Optical calibration system: The Nanobeacon. The Laser Beacon. – Cross-check methods: K40 and atmospheric muons. Summary. 10/15/20092F. Salesa - VLVNT09

KM3NeT will be a NT of at least 1 km 3 of sea water (Mediterranean Sea) and a deep-sea infrastructure for earth and sea science. Formed by 41 institutions from 10 countries. To be deployed after /15/2009F. Salesa - VLVNT093   c =43°

The angular resolution is critical in a NT. A good angular resolution provides the needed point spread function to resolve cosmic neutrino sources from the atmospheric background. The angular resolution relies on a good positioning and time calibration. Working within the specifications the attainable angular resolution of KM3NeT is better than 0.1° for E > 100 TeV. absolute time resolution The absolute time resolution (provides a specific time for each neutrino event w.r.t. UT) depends on: GPS timing. Detector electronic paths. In order to obtain correlations with the physics phenomena (e.g. GRB) an accuracy of 1 ms is enough. Relative time resolution Relative time resolution (among OMs) depends on: OM transit time spread (TTS), typically  ~1-1.5 ns. Optical properties of the sea water: light scattering + chromatic dispersion (  ~1-1.5 ns) for light coming from a distance of 50 m. Electronics (  <0.5 ns). All these components give an overall unavoidable time spread of 1-2 ns. The determination of the calibration constants with a  ≤1 ns fulfils the requirements for relative time resolution. 10/15/20094F. Salesa - VLVNT09

Before the deployment the time calibration constants are determined in the laboratory. The calibration consists of two main parts: one to obtain the clock-phase delay, another to obtain the intrinsic OM time offset: – The clock-phase delay is given very precisely by the internal clock calibration. – A special setup should be designed for the intrinsic time offset computation. The special setup can also be used for additional calibrations (e.g. electronics & charge). The internal clock calibration is repeated in situ. 10/15/20095F. Salesa - VLVNT09 Optical fibres Signal splitter Laser STARTSTOP GPS E/O/ E STARTSTOP On-shore Station Time Digital Converter In-situ Echo-based system Junction Box optical splitter Special calibration setup

The experience from the previous projects shows that a system of external light sources with a known emission time ensures the time calibration and provides measurements of the optical water properties (c.f. H. Yepes talk). Decoupling the intra/inter detection unit (DU) calibration seems the best solution: – The calibration in the same storey and in the same DU will be performed by a group of Nanobeacons. – The calibration among DU will be performed by several Laser Beacons. The calibration constants are obtained putting all the information together. 10/15/20096F. Salesa - VLVNT09 Laser LED

One Nanobeacon inside each OM (can be used for TTS monitoring). The OM housing the nanobeacon provides the reference time. Designed to illuminate storeys in the same DU (points upwards). Based on the ANTARES LED Beacon, but with improvements: – Less expensive. – High redundancy. – Avoid cumbersome synchronization process, only one (or two) LED. – Not triggered by the clock which can induce electronic noise. Laboratory tests performed: angular distribution, pulse shape, etc. 10/15/20097F. Salesa - VLVNT09 LED modelRise time (ns) (nm) FWHM (º)Intensity (pJ) CB CB NSPB520S AB

The circuit works at a nominal 24 V. The flashing rate depends on the feeding voltage (no external trigger). It is 25 kHz at 24 V and requires only an on/off interface. One single LED is expected to reach 350 m (90 pJ ~2 x 10 8 photons). In ANTARES one LED reach ~200 m. First tests performed mounting the Nanobeacon in an OM from ANTARES in water. 10/15/2009F. Salesa - VLVNT098 RMS ~ 1 ns Trigger signal w.r.t. OM signal PRELIMINARY

In the peak region (± 10°) the KM3NeT LED emits 1.5 orders of magnitude more than the ANTARES LED. An opening angle of 15° is sufficient to illuminate OMs placed above, even in a perpendicular arrangement (NuONE DU). The pre-selected model is the Avago HLMP-CB30 LED. 10/15/2009F. Salesa - VLVNT099 50m 6m - KM3Net LED model (uncleaved) - ANTARES LED model (cleaved) - KM3Net LED model (uncleaved) - ANTARES LED model (cleaved)

Based on the ANTARES Laser Beacon (diode pumped Q-switched Nd-YAG laser). Some Laser Beacons will be deployed at the bottom of several DU. Alternatively to the previous green ANTARES laser ( = 532 nm). There is the possibility of working with a blue laser ( = 473 nm). The amount of light emitted can be tuned by means of a voltage controlled optical attenuator. An internal photodiode reads the signal and provides its timestamp. 10/15/2009F. Salesa - VLVNT0910 Laser Properties Blue (473 nm)ANTARES Green (532 nm) New Green (532 nm) Average power 20 mW~0.8 mW45 mW RatekHz range Pulse energy 5  J1  J45  J Rise time< 1.5 ns~ 0.6 ns~0.15 ns Liquid Crystal Retarder Polarizing Beam-Splitter Laser Head Polarizing cube beam-splitter Liquid Crystal Head Variable Voltage

10/15/2009F. Salesa - VLVNT0911 Calibration constants correction RMS ~ 0.7 ns Time difference between a LED OB and an OM Electronics contribution less than 0.5 ns RMS ~ 2 ns RMS ~ 0.6 ns Only 15% larger than 1 ns Retuning of feeding HV can be corrected with the OBs 00 0 PRELIMINARY σ ~ 0.4 ns

Background signal can be used to cross-check the time calibration. For configurations with adjacent OMs in the same storey, the K40 present in the salt water can be used for charge and intra-storey time calibration of the detector. Atmospheric muons (both up-going and down-going) can be used for the calibration among and in the same DU. 10/15/2009F. Salesa - VLVNT K 40 Ca  e - (  decay)  Cherenkov Gaussian peak on coincidence plot OM 0 OM 1 OM 2 Taking differences by pairs

The check of the time offsets measured by the K40 shows the improvement using the calibration constants computed by the OB system. The calibration constants computed with intense light sources (OBs) are still valid at lower intensities (K40). 10/15/2009F. Salesa - VLVNT0913 RMS=0.71 ns RMS=0.50 ns Laboratory Calibration constants OB calibration constants

The time calibration of KM3NeT based on the previous NT projects experience. An absolute time calibration of 1 ms is enough and a relative time calibration at the nanosecond level is desirable. A first calibration will be performed in the laboratories. An optical calibration system will be used for the in situ time calibration (results from ANTARES encourages that system). Decoupling of intra/inter DU calibration. Optical and muon background can be used as a cross-check. Thanks to the time calibration systems, KM3NeT will be able to achieve an angular resolution better than 0.1° for E > 100 TeV. 10/15/200914F. Salesa - VLVNT09

This system is used to calibrate the path travelled by the signal starting at the PMT photocathode up through read-out electronics. It can be achieved by using an LED pulser mounted close to the PMT and capable of illuminating the photocathode, or via an optical fibre illuminated with a laser or LED outside the OM. 10/15/200915F. Salesa - VLVNT09 Example of a similar system used in the ANTARES OMs. LED Blue LED

10/15/2009F. Salesa - VLVNT0916 MAXIMUM INTENSITY 24

K40 10/15/2009F. Salesa - VLVNT0917 LED OB LED OB – K40 40 K 40 Ca e - (  decay) Cherenkov light  K40 The offsets calculated with the LED OBs are validated by the K40 (independent calibration procedure) The K40 test is done by pairs because we know neither the position of the source nor the time emission of the light. With the LED Beacon we can reproduce this test with more precision and with a more intense light source. ANTARES line

10/15/2009F. Salesa - VLVNT0918 Without alignment With alignment The laser is fixed on the anchor. Therefore it can be used to check the line movements. If the line is considered rigid and straight, the time difference distribution has a RMS ~ 2.3 ns. Taking into account the shape of the line the values are distributed within RMS ~ 0.6 ns. σ=0.6 ns

10/15/2009F. Salesa - VLVNT0919 NuONE DU MEDUSA DUSeaWiet DU