SEEM 94 Calibration to RBSA Data Progress Report on Phase 2 (Digging a Little Deeper) Subcommittee Regional Technical Forum March 20, 2013.

Slides:



Advertisements
Similar presentations
Autocorrelation and Heteroskedasticity
Advertisements

New MT Houses with Ground Source Heat Pumps Energy Savings and Costs June 2 nd, 2009 Regional Technical Forum 1.
Chapter 5 Multiple Linear Regression
SEEM Calibration: Revisited Revising the regression to use continuous heat loss variable Regional Technical Forum December 17, 2013.
New Construction Calibration Research Results and Request for Decision Regional Technical Forum March 18, 2014.
Irwin/McGraw-Hill © Andrew F. Siegel, 1997 and l Chapter 12 l Multiple Regression: Predicting One Factor from Several Others.
Residential Single Family Weatherization and HVAC Measures Progress Reports: 1.Estimating Electric and Supplemental Fuels Savings 2.Estimating Value of.
SEEM 94 Calibration to Single Family RBSA Data Analysis and proposed actions RTF SEEM Calibration Subcommittee May 7, 2013.
The Saga Continues: Measure Interactions for Residential HVAC and Wx measures Regional Technical Forum April 23, 2014.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Statistics: Unlocking the Power of Data Lock 5 STAT 101 Dr. Kari Lock Morgan Multiple Regression SECTION 10.3 Categorical variables Variable selection.
Class 16: Thursday, Nov. 4 Note: I will you some info on the final project this weekend and will discuss in class on Tuesday.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
© 2000 Prentice-Hall, Inc. Chap Multiple Regression Models.
Multiple Regression Models. The Multiple Regression Model The relationship between one dependent & two or more independent variables is a linear function.
Regression Model Building Setting: Possibly a large set of predictor variables (including interactions). Goal: Fit a parsimonious model that explains variation.
Estimating Heating Energy from Utility Bills More on the “Phase 2” Adjustment Ecotope, Inc.
Electric “Grid” Savings and Non-Electric Benefits for Residential HVAC-effected UES Measures Regional Technical Forum March 20, 2013.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
SEEM 94 Calibration to Single Family RBSA Data Regional Technical Forum January 23, 2013 Analysis Performed ByAdam Hadley Cursory Reviews By Tom Eckman,
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
Managed by UT-Battelle for the Department of Energy Weatherization Assistant: What’s New in Versions 8.4 and 8.5 Mark Ternes Mike Gettings Oak Ridge National.
Objectives of Multiple Regression
SEEM Tool Overview Regional Technical Forum Member Orientation January 22, 2013.
Inference for regression - Simple linear regression
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF MH Calibration Subcommittee February 27, 2015.
SEEM 94 Calibration to Single Family RBSA Data Analysis and proposed actions Regional Technical Forum May 21, 2013.
Manufactured Homes Calibration: Existing and New Homes Josh Rushton & Mohit Singh-Chhabra RTF Update June 16, 2015.
© 2004 Prentice-Hall, Inc.Chap 15-1 Basic Business Statistics (9 th Edition) Chapter 15 Multiple Regression Model Building.
© 2002 Prentice-Hall, Inc.Chap 14-1 Introduction to Multiple Regression Model.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Northwest Ductless Heat Pump Pilot Project Impact & Process Evaluation: Billing Analysis Ecotope, Inc. February.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
SEEM Calibration: Phase-2 Adjustments for Failed VBDD Fits Regional Technical Forum August 12, 2014.
Chap 14-1 Statistics for Business and Economics, 6e © 2007 Pearson Education, Inc. Chapter 14 Additional Topics in Regression Analysis Statistics for Business.
Analysis of Weatherization Measures Options for Savings Methodology and Presentation of Costs from 6 th Plan Regional Technical Forum May 4 th, 2010.
SEEM Input Variables for RBSA Calibration Manufactured Homes RTF Subcommittee on SEEM MH Calibration May 9, 2013.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum September 17, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum August 20, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum November 19, 2013.
SEEM Calibration for Manufactured Homes Regional Technical Forum July 15, 2014.
SEEM Calibration: Phase-2 Adjustments for Failed VBDD Fits RTF Calibration Subcommittee July 31, 2014.
Residential Duct Insulation New Deemed Measure Proposal – A Second Look Regional Technical Forum May 4 th, 2010.
Goodbye, “Last Measure In” Hello, “Option X”? Staff Proposal for how to deal with the last measure in conundrum Regional Technical Forum October 15, 2013.
CROSS-VALIDATION AND MODEL SELECTION Many Slides are from: Dr. Thomas Jensen -Expedia.com and Prof. Olga Veksler - CS Learning and Computer Vision.
Statistics: Unlocking the Power of Data Lock 5 STAT 101 Dr. Kari Lock Morgan Multiple Regression SECTION 10.3 Variable selection Confounding variables.
REM as a Compliance Tool Infiltration Trade-off REMRate vs. SEEM February 19th,
SEEM Calibration for Manufactured Housing Regional Technical Forum December 13, 2011 Analysis Performed ByAdam Hadley Cursory Reviews ByTom Eckman, Ben.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Analysis of Weatherization Measures Savings Methodology and Costs: Updated from 6 th Plan Regional Technical Forum June 1 st, 2010.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
Electric “Grid” Savings and Non-Electric Benefits for Residential HVAC-affected UES Measures Regional Technical Forum March 20, 2013.
Statistics for Managers Using Microsoft Excel, 4e © 2004 Prentice-Hall, Inc. Chap 14-1 Chapter 14 Multiple Regression Model Building Statistics for Managers.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
New Construction Calibration Preliminary Research and a Request for Guidance on Issues Raised in December Regional Technical Forum January 22, 2013.
Basic Business Statistics, 10e © 2006 Prentice-Hall, Inc. Chap 15-1 Chapter 15 Multiple Regression Model Building Basic Business Statistics 10 th Edition.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Chapter 11: Linear Regression and Correlation Regression analysis is a statistical tool that utilizes the relation between two or more quantitative variables.
Statistics for Managers Using Microsoft Excel, 4e © 2004 Prentice-Hall, Inc. Chap 14-1 Chapter 14 Multiple Regression Model Building Statistics for Managers.
Where did it go? Lost savings found in real-world data SEEM Calibration for the Northwest Power and Conservation Council’s Regional Technical Forum (RTF)
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
Extra Slides to Accompany: SEEM 94 Calibration to Single Family RBSA Data Analysis and proposed actions Regional Technical Forum May 21, 2013.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
Inference for Least Squares Lines
Presentation transcript:

SEEM 94 Calibration to RBSA Data Progress Report on Phase 2 (Digging a Little Deeper) Subcommittee Regional Technical Forum March 20, 2013

Background Ran SEEM on 289 RBSA houses. Full RBSA sample (n = 1404) whittled down due to – Presence of non-gas / non-electric heat, – Poor billing fits, – More than one foundation type, – Other… T-Stat “Calibration” by heat source only  – Aligns SEEM with PRISM kWh averages for each heating-system group. RTF requested further research: – Assess calibration needs related to other variables (climate, measure parameters, etc) in addition to heating system. See January 23, 2013 presentation and minutes for more detailspresentationminutes 2

Research Objectives Identify and quantify any systematic patterns (trends) in the differences, ∆ kWh = SEEM kWh ‒ PRISM kWh. – “Systematic” means “explained by known variables.” (Example: SEEM kWh tends to exceed PRISM kWh in cooler climates.) – Problem is multivariate. A single underlying trend (for example, ∆ increasing with heating costs) may be apparent in multiple guises (∆ increases with HDD, or with U-value, or fuel type.) Develop calibration procedure to remove systematic differences. – Express calibration in terms of T-stat adjustments. – Understand calibration impact on measure-related parameters. 3

General Approach Regression analysis – Compare PRISM output with SEEM output when SEEM is run at with a constant T-stat setting. All 289 SEEM values generated with T-stat = 68°F. – Y-value is the percent difference between SEEM kWh and PRISM kWh. – X-values are parameters known through RBSA. (Discovering explanatory variables is part of the goal.) Assumptions: – Billing (PRISM) results are generally unbiased (excepting obvious errors) 4

Data Issues Heteroskedasticity. – The SEEM/PRISM differences generally increase in magnitude in proportion to SEEM kWh (or PRISM kWh) Measurement error (random noise). – As estimates of heating kWh, SEEM and PRISM both have substantial standard errors. 5

6 Heteroskedasticity…

Regression Step 0: The y-variable 7

Regression Step 1: The x-variables Goal: Identify variables having systematic influence on y-values. – Substantial random noise in both y-values and x-values, so “influence” is only seen in rough trends (think: correlation). Prominent x-variable candidates: – Measure-related parameters (U-values, duct tightness, infiltration, …) – Heating system type – Climate parameters (esp. HDDs) – Others? Model development is iterative. – A variable may be weakly correlated with raw y-values but strongly correlated with y’s that have been adjusted to account for some other variable’s influence. Need a single regression model that includes all important x- variables at once (different models for separate calibrations okay). 8

Limitations to keep in mind… Multicollinearity. When a potential x-variable closely tracks some combination of variables that are already included. – This redundancy leads to unstable model fits. – Threshold for “tracks too closely” gets low when the usual suspects are around: High noise / faint signal / small sample. Parsimony. General principle: Don’t over-fit the data (by including too many explanatory variables). Some variables aren’t known for many houses. 9

10

Current Status There are substantial systematic patterns (in the y-values) related to U-value and heating system type. Final model must account for these. – Each variable’s influence persists after controlling for the other variable. – Wall-, ceiling-, and floor- U-values are too strongly correlated to separately include in one model. (Must combine into one or two coarser variables). Several other variables are influential too, but we can’t include them all. Still developing variables and comparing models. We present a particular linear model with variables for: Insulation, Heating System Type, and Heating Degree Days Purpose is to convey trade-offs and solicit input. 11

Insulation Variable(s) Model uses an indicator variable to capture “Poor Insulation”. – Definition: Insulation is “poor” if: (Wall u-value > 0.25) OR (Ceiling u-value > 0.25) OR both. – Judgment call in choosing this indicator variable versus the (continuous) weighted-average u-value, U 0. – Still checking options for floor- and window u-values. Floor-u variable is tricky because of different foundation types. 12

13

Heating System Variable Four distinct heating systems in the sample: Electric zonal Electric FAF Gas FAF Heat pump After controlling for insulation, heating system effect mostly captured with just two groups: “Electric Resistance” = Electric zonal / Electric FAF “Gas/HP” = Gas FAF / Heat Pump Parsimony: two is better than four! 14

15

16

17 Regression fit for this model

18

19 Interpreting the fitted model

Interim Calibration Results (for this example) 20

And Finally, Translate percent kWh adjustments into adjustments in daytime t-stat setting (from 68 °F). Do we interpret t-stat calibrations literally (as in, homes like this tend to maintain lower winter temps)? (Refer to morning session!) No data limitations here: we can directly observe SEEM’s sensitivity to t-stat settings. – Just run SEEM multiple times, with a different setting on each. 21

22

23 Calibration Results (for this example) There were no cases of poor insulation in heating zone 3 within the filtered sample (289).

Discussion Is this the correct approach? Keep in mind we’re still working on incorporating other variables into the model Duct tightness Infiltration Floor u-value Window u-value 24