NANS I 3 Steve Adler December 6, 2012. Indications for Use U.S. –Infumorph Europe –Morphine and Baclofen.

Slides:



Advertisements
Similar presentations
IB Portfolio Tasks 20% of final grade
Advertisements

Key Performance Indicators KPI’s
Using Information Technology and Community-based Research to Improve the Dental Health Care System Kathryn A. Atchison, DDS, MPH Professor, Division of.
Public Health Issues Related to Mutually Conforming Labeling: CDRH Perspective Miriam C. Provost, Ph.D. Office of Device Evaluation Center for Devices.
Syringe Pumps. Topics  Diagrams  Principles of Operation  Applications  Safety  Operation  Preventive Maintenance  Common Failure Modes  Troubleshooting.
Electronic Medication Management (eMM) Concepts and Definitions Dr Stephen Chu.
Role of Pharmacoeconomics in a Developing country context Gavin Steel for Anban Pillay Cluster Manager: Health Economics National Department of Health.
Math Review & Basic Pharmacology Math
Hydraulics.
Safety and Precision of Implanted Intrathecal Pumps December
An Alternative Method for Aerosolized Prostacyclin Administration during Mechanical Ventilation Harborview Medical Center Seattle,Washington Travis J Leistiko.
INTRODUCTION TO ICD-9-CM
ETIM-1 CSE 5810 CSE5810: Intro to Biomedical Informatics Mobile Computing to Impact Patient Health and Data Exchange and Statistical Analysis Presenter:
Project Control Farrokh Alemi, Ph.D. Lee Baliton.
Clinical Pharmacy Basma Y. Kentab MSc..
Health, Medicine and Biotechnology Opportunity Accurate Measurement of OPA Concentration for Disinfection Applications Benefits: An analytical process.
Use of the Personal Therapy Manager With Prialt® (Ziconotide Intrathecal Infusion) for Patient-controlled Analgesia: Case Series Gladstone C. McDowell,
Background to Adaptive Design Nigel Stallard Professor of Medical Statistics Director of Health Sciences Research Institute Warwick Medical School
Responsibilities and Principles of Drug Administration
INTRODUCTION TO MEASUREMENT
The Disposable Infusion Pump Instruction Basal + PCA Bolus Model.
Preventing Surgical Complications Prevent Harm from High Alert Medication- Anticoagulants in Primary Care Insert Date here Presenter:
Biomedical Research.
Blood Fluid Warmers Purpose Body temperature
LECTURER PROF.Dr. DEMIR BAYKA AUTOMOTIVE ENGINEERING LABORATORY I.
Quality Control Lecture 5
Monthly Journal article review: Vimmi Kang PGY 2
Quality Assurance How do you know your results are correct? How confident are you?
The USP Performance Test Dissolution Systems Suitability Studies Walter W. Hauck, Ph.D. USP Consultant Presentation to Advisory Committee for Pharmaceutical.
Pharmacists Perceptions of the Development of Herbal Medicines in Iran
NANS I3 Technology Gaps in Intrathecal Drug Delivery Systems
Intrathecal Pumps Thomas Yeargin Biomedical Engineering BME 281 Section 1.
ELECTRICITY COST OF CHILLER AND COOLING TOWER PUMPS KILLING YOU? We Have The RIGHT Solution just for YOU! + =
How To Design a Clinical Trial
RESEARCH & DATA ANALYSIS
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Organization of statistical research. The role of Biostatisticians Biostatisticians play essential roles in designing studies, analyzing data and.
10 May Understanding diagnostic tests Evan Sergeant AusVet Animal Health Services.
BIOSTATISTICS Lecture 2. The role of Biostatisticians Biostatisticians play essential roles in designing studies, analyzing data and creating methods.
Course: Research in Biomedicine and Health III Seminar 5: Critical assessment of evidence.
TLD POSTAL DOSE QUALITY AUDIT FOR 6MV AND 15MV PHOTON BEAMS IN RADIOTHERAPY CLINICAL PRACTICE Sonja Petkovska 1, Margarita Ginovska 2, Hristina Spasevska.
Quality Control Internal QC External QC. -Monitors a test's method precision and analytical bias. -Preparation of quality control samples and their interpretation.
L ABORATORY Q UALITY C ONTROL. INTRODUCTION _A major role of the clinical laboratory is the measurement of substances in body fluids or tissues for the.
Calculation of Basic IV Drip Rates
INTRODUCTION TO SYNDROMIC MANAGEMENT OF STIs
EKT 314/4 WEEK 1 : CHAPTER 1 INTRODUCTION TO EI ELECTRONIC INSTRUMENTATION.
Safe use of HYDROmorphone
Cindy Tumbarello, RN, MSN, DHA September 22, 2011.
Taper DPI FeatureImpact Efficacy Safety Compliance Cost High Efficiency  Equivalent lung dose achieved in- vitro with approximately 50% lower delivered.
Ventricular Assist Device Test Loop Client: Minnetronix, Inc. Advisor: Kristyn Masters Team: Joe Bothwell, Dan Carlson, Kayla Ericson, and David Ugai.
Introduction to Lab Techniques Measurements and Calibration.
Total Parenteral Nutrition
How To Design a Clinical Trial
Microchips Biotech Technology
Mary Alexander, MA, RN, CRNI®, CAE, FAAN Chief Executive Officer
This program will include a discussion of off-label treatment and devices and investigational agents and devices not approved by the FDA for use in the.
Aiying Chen, Scott Patterson, Fabrice Bailleux and Ehab Bassily
Annals of Internal Medicine • Vol. 167 No. 12 • 19 December 2017
Y10 Triple Scientists Biology ISA
PROGRAMMABLE MEDICATION INFUSION PUMP Non-Confidential Overview
Introduction To Medical Technology
Module 6 Part 3 Choosing the Correct Type of Control Chart Limits
Objectives Chapter 9 Name the parts of drug labels
CRITICAL CARE NURSES CHAPTER----QUALITY IN CRITICAL CARE.
Chapter 5 Calculations for Sterile Compounding.
EC 217 MEASUREMENTS AND INSTRUMENTATION
Introduction to IV Therapy
Presentation transcript:

NANS I 3 Steve Adler December 6, 2012

Indications for Use U.S. –Infumorph Europe –Morphine and Baclofen

Accuracy Definition: Accuracy refers to the correctness of a single measurement. Accuracy is determined by comparing the measurement against the true or accepted value. For our purposes, the true or accepted value is the programmed dose

Examples of Poor Accuracy

Introduction Product development process for accurate pump –Requirements –Solutions – valve gated technology –Bench or verification tests Clinical study results Clinical significance, next steps

Design Considerations for Accurate (Precise, Durable) Pump Prior pumps had shortcomings Important design considerations –Accuracy of drug delivery –Accuracy of reported volume in reservoir –Consistency of amount received by the patient over time –Limit any variation in flow rate due to programmed dose, battery age, reservoir volume, temperature or pressure –Ability to accurately deliver micro-doses –No variation in device performance over a wide range of concentrations and compounds

Product Development New technology was required to design a pump with a an accurate dosing mechanism –The challenges were to design A completely different flow regulating mechanism Electronics that would allow precise timing and provide redundant safety checks A power supply with exceptional longevity Communication capabilities that were insusceptible to interference and able to prevent programming errors

Dose Accuracy 98% No temp, pressure, reservoir volume effects Longevity >10 years Designed to deliver any compound Can deliver micro- doses Prometra Pump

Dose Regulation Valve-Gated Dosing Chamber

Bench Testing Extensive bench testing was performed to confirm overall accuracy, as well as accuracy under a variety of conditions. –Pressure extremes –Temperature extremes –Various programmable rates –Various reservoir fill levels –Various environmental exposures Temperature cycling Electric shock exposure Vibration testing Multiple sterilization cycles –Drug flow accuracy was within specification in each testing scenario.

Bench Testing Results

Ongoing Life Testing

PUMP Clinical Study: Accuracy Results Accuracy was calculated as the delivered (volumetrically determined) to programmed (DP) drug volume ratio –Numerator: sum of delivered drug volumes over all (scheduled and unscheduled) valid fill/refill sessions per patient –Denominator: sum of programmed drug volumes over all (scheduled and unscheduled) valid fill/refill sessions per patient Overall accuracy is calculated by averaging the per patient DP ratios Accuracy Results (%) Number of Refills = 2,073 Number of Patients = 148 Mean98.4 Standard Error0.5 90% Confidence Interval(97.6 – 99.2)

Accuracy by Flow Rate Flow rate range: mL/day No statistically significant differences between flow rate categories

Accuracy by Months Post-Implantation No statistically significant differences between any of the time-points

Accuracy by Residual Volume ( ] was lower than [ ] (p=0.0119) ( ] was lower than all other categories (p<0.0001) Mean accuracy was 100% in the lowest residual volume category (0.0, 4.0].

Accuracy by Concentration Morphine concentration range: 1-50 mg/mL No significant differences between concentration categories No pump failures or other complications occurred related to drug concentration

Ongoing Continued Evaluation LSU Health Science Center

Durability and Longevity The only moving parts are the valves Fewer moving parts and a simpler design mean less opportunity for complications The valves require very little energy Promotes longer battery life, requiring fewer replacement surgeries over the course of a patient’s IT therapy.

Accuracy With Other Drugs? Proper function of pumps can be affected by the drug being delivered. –Concentration, molecular size, and corrosion of pump materials can have serious effects Clinical trial results indicate that the Prometra Pump is very accurate when delivering morphine sulfate –Experience with both Infumorph ® and compounded morphine at a wide range of concentrations What about other drugs? –Accuracy should be unaffected by the type of drug in the pump. 1 –The titanium dosing chamber of the Prometra Pump simply measures the exact volume of the fluid to be delivered. This measurement is unaffected by type of fluid in the chamber 1 Yearwood, T. Results of Secondary Pain Medications to Improve Pain Outcomes in The Prometra Programmable Infusion Pump. Poster Presentation at the 11th Annual ASRA Pain Medicine Meeting, November 2012

Clinical Significance? Scheduling of refill visits Possibly avoiding overdose/underdose, withdrawal symptoms Drug dependent Micro-dosing Future applications

Intraparenchymal (IPa) Intracranial Drug Administration ICV IT Intracerebroventricular (ICV)

Clinical Need for Accuracy in Drug Delivery to the Brain limit exposure to other organs deliver complex dosing pattern greatly reduce effective drug dosage

Conclusions Achieved design goals –98% accurate, independent of external factors Confirmed in bench tests Validated in clinical trials Clinical significance depends on disease/drugs