Filename: C-CR-10-02Rev00Page 1 of 3Record no.: C-CR-10-02Rev00 Appendix 2(a): Water Treatment Equipment and Sampling Points Guideline for Water Treatment.

Slides:



Advertisements
Similar presentations
TZW Karlsruhe Prüfstelle Wasser The Influence of Water Treatment on Corrosion of Materials in Service Lines and Drinking Water Installations Josef Klinger.
Advertisements

Process Of Reverse Osmosis Plant
Australian water filter.
Overview AST Clean water technologies was requested to design and construct an Industrial Waste water Treatment Plant with a capacity of 35 m 3 /h in.
What is dialysis? Dialysis is a treatment for people in the later stage of chronic renal insufficiency (kidney failure). This treatment cleans the blood.
USP/EP Purified Water and Water for Injection Systems – Case Histories
Chemistries and Physics of Water Purification
Common Water Treatment Problems Hard Water -Calcium and Magnesium. Soap Scum, and Scale Build-Up. Iron - Clear (Ferrous), Red (Ferric), & Bacteria Related.
WHO - PSM Water for Pharmaceutical Use Water –part 2 Workshop on GMP and Quality Assurance of HIV products Shanghai, China 28 Feb - 4 March 2005 Maija.
New Developments in Renal Dialysis WH Seto WHO CC, Hong Kong 5, 2012 Hosted by Prof. Lance Jennings University of Otago,
Dialysis Water Treatment Systems
EG Medical Systems Maintenance BU MEDICAL SYSTEMS Service Department Scope  Service Department offers after sales service for products sold by EG Medical.
1 Reminder: Resistivity (ohms) is the reciprocal to conductivity (micro-Siemens)
Membrane Processes For Waste Water Treatment By: Rohit Chaurasia 3 rd B. Tech. Civil Engineering 71/08.
The Maritime Alliance “Promoting the Maritime Community” Symposium on Desalination and Related opportunities Terry D. Smith Toray Membrane USA.
Water for Pharmaceutical Use Water Purification Engineering Md. Saifuzzaman Associate Professor Pharmacy Discipline, KU.
MARKEL Reverse Osmosis Water Purifiers. Markel Unit  There are many people living in rural areas, very worried about the increasing Nitrate levels in.
20,000 Barrel Per Day Produced Water Treatment System
2-PIPE DIRECT RETURN SYSTEM
Cornerstone Engineering Group The Foundation for Your Civil Engineering Needs Camanche Reservoir Water Treatment Plant Project Cecilia Zamora Evangelina.
Water Treatment and Distribution in London. Lake Huron & Elgin Area Water Supply Systems London is supplied treated water through the Lake Huron Primary.
Water Treatment Plant #3 Concentration Utilization at Water Treatment Plant #1.
Key Elements of a Safe Water Supply An Adequate and Protected Water Source A Secondary Supply A Quality Treatment System An Adequate Finished Water Storage.
Information about Purified water Ten steps to Purified Water Photos of Purified water in process Conclusion.
Waupun Utilities Water Treatment Facility. Treatment Processes Source Water Pretreatment System Reverse Osmosis System Post Treatment System Distribution.
Water | Slide 1 of 30 January 2006 Water for Pharmaceutical Use Part 3: Inspection of water purification systems Supplementary Training Modules on Good.
Desalination Using Looped Ion Exchange By Karla Montemayor Mentor: Dr. Wendell Ela University of Arizona Department of Chemical and Environmental Engineering.
Water Purification Systems for Clinical Lab Prepared By Farid Khalaf.
THE BASICS of SFR Spot Free Rinse Systems - working to keep your reputation spotless  Spot Free Rinse water must have less than 40 ppm of TDS. Our preferred.
Transitions to Surveys with New ESRD Regulations
Rural Drinking Water Treatment System. INTRODUCTION Water demand Identification of water source Drinking water Quality Parameters Required treatment system.
Reverse Osmosis Feed Treatment, Biofouling, and Membrane Cleaning
Water Treatment for Dialysis Jeff Kaufhold, MD FACP Nephrology Associates of Dayton Oct 2008.
1 Practical Tips to Emergency Preparedness John Dahlin CHT, CWS-1 Texas ESRD Emergency Coalition.
Water for Pharmaceutical Use Part 2: Water purification engineering
Agenda August 5, Introduction – Natalie Robottom 2.Background and History – Rob Delaune 3.Present Conceptual Engineering Design Proposed Tasks -
Water Treatment Division Wall mounted. Use of an antiscalant with automatic mixture preparation. Water softener only for boiler Production capacity can.
The Importance of Distribution. Manifold Position And Vapor Trail.
Water Treatment for the Recycling of Process Rinse Water
Honda factory, Guangzhou, China Objective: provide drinkable water to 5'000 employees.
Water and Wastewater Treatment
December 10, 2009 TOWN OF PALM BEACH WATER COMMITTEE Discussion of Water Plant Options.
Desalination for Drinking Water Purposes TCEQ Trade Fair David A. Williams, P.E Robert W. Sims, P.E. Austin, Texas May, 2016.
HOUSEHOLD WATER TREATMENT. Water Quality Problems Recommendations New source Pollution control Maintenance + inspection Treatment Explore all of them.
Water Treatment Fundamentals. Agenda MEP Fundamentals (1 st badge): Ion exchange chemistry Softener designs and options Ion exchange capacity calculations.
BIRUNIPHARM LLP, PHARMACEUTICAL COMPANY, WAS ESTABLISHED ON DECEMBER 11, 2009 IN ALMATY AND IS EQUIPPED WITH MODERN TECHNOLOGICAL EQUIPMENT. About Company.
How Reverse Osmosis Water Purification Systems Work.
Phone FREE Pure-Pro USA Corp.|9200 W. 191st Street Unit 5, Mokena, ILLINOIS Welcome to Pure-Pro USA Corp. Website -
Life is Portable Mineral Water Factory Your Life, Your Water!
RAINMAKER and RAINMAKER Enviro
RO and standards Your title can go in a clear space
RO Basics and System set up
Hub 4 Water Media Filters
Hub 4 Water Design, build, installation and servicing of all systems
Fill Add 80 gallons Treat Greywater Rinse Treat Intermediate Treatment
REVERSE OSMOSIS PLANTS 5-35kl/day
Hub 4 Water Hub 4 Water Softener
MAKE THE BEST OUT OF YOUR RO PURIFIER! – HANDY TIPS.
REVERSE OSMOSIS PLANTS kl/day
Boiler System Make-up Water Primary Secondary Pretreatment
Hub 4 Water Carbon Filters
Volume 76, Issue 6, Pages (September 2009)
Streaming Current Detectors
Volume 76, Issue 6, Pages (September 2009)
Reverse Osmosis Water or Tap Water?
1.3 Diffusion and Osmosis Chapter 1.
Sea water Reverse Osmosis
Pure water from RO system Reuse to manufacturing
MIFAB® LifeLine Stainless Steel Dialysis Boxes
2-PIPE DIRECT RETURN SYSTEM
Presentation transcript:

Filename: C-CR-10-02Rev00Page 1 of 3Record no.: C-CR-10-02Rev00 Appendix 2(a): Water Treatment Equipment and Sampling Points Guideline for Water Treatment Equipment (Doc. No.: C-CG-10-02/Rev.00) Pre-treatment System (chapter 5.2) Legend: Optional Equipment Sample Point Guideline chapter (5.2.1) Note 1: items (5.2.1) may be positioned before or after (5.1) Note 2: item (5.2.2) may be positioned after (5.2.3). Recommended position shown. Note 3: use both sampling points if duplicate equipment installed X Feed Water Tank and Pump (5.1) Water Softener (5.2.2) Carbon Filter(s) (5.2.3) Post Carbon Cartridge Particle Filter(s) (5.2.4) 3544 Multi-Media Particle Filter (5.2.1) 1 22 Cartridge Particle Filter (5.2.1) 5 To: Primary RO From: Feed Water Supply

Filename: C-CR-10-02Rev00Page 2 of 3Record no.: C-CR-10-02Rev00 Secondary Reverse Osmosis ( in series) (5.4.1) Ultrafilter (5.4.2) From: Pre-treatment Dialysis Machine 13 Primary Reverse Osmosis (5.3) Diasafe, pre-dialyser Design 1 (chapter 5.0): Direct Feed Reverse Osmosis System Legend: Optional Equipment Sample Point Guideline Chapter (5.4.1) X Central Delivery Acid Concentrate (and/or Bicarbonate - not recommended) Distribution Loop (5.5.2) Page 2 of 3 Appendix 2(b): Water Treatment Equipment and Sampling Points Guideline for Water Treatment Equipment (Doc. No.: C-CG-10-02/Rev.00)

Filename: C-CR-10-02Rev00Page 3 of 3Record no.: C-CR-10-02Rev00 Appendix 2(c): Water Treatment Equipment and Sampling Points Guideline for Water Treatment Equipment (Doc. No.: C-CG-10-02/Rev.00) Legend: Optional Equipment Sample Point Guideline Chapter (5.4.4) Primary Reverse Osmosis (5.3) Ultra Violet Steriliser (5.4.4) Submicron Membrane Filter (5.4.3) Treated Water Tank and Pump (5.5.1) 6 Ultrafilter (5.4.2) Design 2 (chapter 5.0): Reverse Osmosis System with Treated Water Storage Tank Ring Main Return to pre-RO (optional ) 8 From: Pre- treatment X Distribution Loop (5.5.2) Page 3 of 3 10 CDI / Deioniser (5.4.5) Dialysis Machine 13 Central Delivery Acid Concentrate (and/or Bicarbonate - not recommended) 11 12