The Growing Interdependence of the Internet and Climate Change Scientific Computing and Imaging (SCI) Institute Distinguished Lecture University of Utah.

Slides:



Advertisements
Similar presentations
© Technical University of Catalonia - Second University of Naples - Barcelona Supercomputing Center (BSC)1 Chapter x: Green Datacenter Infrastructures.
Advertisements

Three Disruptive Leadership Opportunities for Washington State to Live in the Future Keynote Talk Washington Innovation Summit: New Decade, New Partnerships,
Calit2 " Talk Nortel Visiting Team December 12, 2005 Dr. Larry Smarr Director, California Institute for Telecommunications and Information.
Calit2: Experiments in Living in the Virtual/Physical World Pat Ledden Memorial Luncheon Faculty Luncheon Seminar UC San Diego Faculty Club February 24,
Calit2: a SoCal UC Infrastructure for Innovation Welcoming Talk Visit to Calit2 by The Trusteeship April 24, 2010 Dr. Larry Smarr Director, California.
Coupling Australias Researchers to the Global Innovation Economy Fourth Lecture in the Australian American Leadership Dialogue Scholar Tour Swinburne University.
How PRAGMA Can Help Save the Planet Banquet Keynote Speech Pacific Rim Applications and Grid Middleware Assembly (PRAGMA) 18 Birch Aquarium, Scripps Institution.
Calit2: The Path Forward Energy Technical Working Group Energy Technical Working Group Kick-Off October 13, 2009 Dr. Larry Smarr Director, California Institute.
High Performance Cyberinfrastructure Enabling Data-Driven Science Supporting Stem Cell Research Invited Presentation Sanford Consortium for Regenerative.
The Growing Interdependence of the Internet and Climate Change Dr. Larry Smarr Director, California Institute for Telecommunications and Information Technology.
The Growing Interdependence of the Internet and Climate Change Invited Talk MITRE Innovation Speaker Series McLean, VA September 16, 2009 Dr. Larry Smarr.
Calit2: Past, Present, and Future University Librarians Advisory Board Luncheon Seminar UC San Diego Library January 4, 2012 Dr. Larry Smarr Director,
High Performance Cyberinfrastructure Enabling Data-Driven Science in the Biomedical Sciences Joint Presentation UCSD School of Medicine Research Council.
Digital Infrastructure in a Carbon-Constrained World SciPM 2009 Workshop on the Science of Power Management Arlington, VA April 9, 2009 Dr. Larry Smarr.
The Strongly Coupled LambdaCloud Tour TTI-Vanguard February 20, 2009 Dr. Larry Smarr Director, California Institute for Telecommunications.
High Performance Cyberinfrastructure Required for Data Intensive Scientific Research Invited Presentation National Science Foundation Advisory Committee.
Can a Greener Internet Help Us Moderate Climate Change? Invited Talk Computational Research in Boston Seminar Series MIT Boston, MA April 15, 2009 Dr.
Uses of the OptIPortal Presentation to the Minority Serving Institutions Cyberinfrastructure Empowerment Coalition June 10, 2010 Dr. Larry.
Calit2-Living in the Future " Keynote Sharecase 2006 University of California, San Diego March 29, 2006 Dr. Larry Smarr Director, California Institute.
Supercomputers and Supernetworks are Transforming Research Invited Talk Computing Research that Changed the World: Reflections and Perspectives Washington,
What Ive Learned About Green Invited Presentation to the ON*VECTOR International Photonics Workshop February 23, 2009 Dr. Larry Smarr Director,
Bringing Mexico Into the Global LambdaGrid Dr. Larry Smarr Director, California Institute for Telecommunications and Information Technology Harry E. Gruber.
The OptIPlanet Collaboratory -- a Global CineGrid Testbed Invited Presentation CineGrid International Workshop 2008 December 8, 2008 Dr. Larry.
Introduction to the UCSD Division of Calit2" Calit2 Tour NextMed / MMVR20 UC San Diego February 20, 2013 Dr. Larry Smarr Director, California.
High Performance Cyberinfrastructure Enables Data-Driven Science in the Globally Networked World Keynote Presentation Sequencing Data Storage and Management.
Energy Leadership Lecture The Institute for Energy Efficiency
Overview of Photonics Research at Calit2: Scaling from Nanometers to the Earth UCSD-NICT Joint Symposium on Innovative Lightwave, Millimeter-Wave and THz.
PRESENTATION TITLE Presenter Name | Date. Abstract Greenhouse gas (GHG) emissions continue their relentless rise, even though the global CO2 level is.
Limiting Global Climatic Disruption by Revolutionary Change in the Global Energy System Keynote Opening Talk Xconomy Forum: The Rise of Smart Energy
Science is Not Enough: The Need for Planetary Design of Geopolitics Invited Talk-Panel on Planetary Data, Planetary Governance DESIGNING GEOPOLITICS An.
The Disruptive Transition to Intelligent, Secure, Low Carbon, and Climate Adaptive Infrastructure Smart Infrastructure Panel Talk American Australian Leadership.
High Performance Cyberinfrastructure Discovery Tools for Data Intensive Research Larry Smarr Prof. Computer Science and Engineering Director, Calit2 (UC.
Calit2: Experiments in Living in the Virtual/Physical World Invited Talk Cultivating Networked Centers of Excellence CineGrid International Workshop 2010.
Why Optical Networks Are Emerging as the 21 st Century Driver Scientific American, January 2001.
Can a Greener Internet Help Us Moderate Climate Change? Calit2 / Institute for the Future Strategic Planning Retreat on Green IT April 25, 2009 Dr. Larry.
"The OptIPuter: an IP Over Lambda Testbed" Invited Talk NREN Workshop VII: Optical Network Testbeds (ONT) NASA Ames Research Center Mountain View, CA August.
The First Year of Cal-(IT) 2 Report to The University of California Regents UCSF San Francisco, CA March 13, 2002 Dr. Larry Smarr Director, California.
The OptIPuter and Its Applications Invited Talk IEEE/LEOS Summer 2009 Topicals Meeting on Future Global Networks July 27, 2009 Dr. Larry Smarr Director,
INTERNATIONAL ENERGY AGENCY AGENCE INTERNATIONALE DE LENERGIE Energy Technology Policy Progress and Way Forward Fridtjof Unander Energy Technology Policy.
ICT Infrastructures and Climate Change Chaesub Lee Chairman of ITU-T SG 13 (ETRI, Korea)
© 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Better business outcomes equal better.
The UCSD/Calit2 NSF GreenLight MRI Tom DeFanti, PI.
Introduction Build and impact metric data provided by the SGIG recipients convey the type and extent of technology deployment, as well as its effect on.
Project GreenLight Measuring the Energy Cost of Applications, Algorithms, and Architectures CENIC Awards Presentation Long Beach, CA March 10, 2009 Larry.
CS : Creating the Grid OS—A Computer Science Approach to Energy Problems David E. Culler, Randy H. Katz University of California, Berkeley August.
Restructuring Campus CI -- UCSD-A LambdaCampus Research CI and the Quest for Zero Carbon ICT Invited Presentation to the Campus Cyberinfrastructure.
Presentation for the 7th ITU Symposium on ICTs, the Environment and Climate Change Greening ICT Infrastructures Session 5/30/12 Dr. Gregory Hidley California.
The Role of University Energy Efficient Cyberinfrastructure in Slowing Climate Change Talk to MGT166 Class Business Ethics and Corporate Social Responsibility.
© 2009 IBM Corporation Let’s Build a Smarter Planet Thongchai Watanasoponwong – Country Manager Power Systems, STG September 15 th, 2009 Green IT เทคโนโลยีสีเขียวเพื่อสิ่งแวดล้อม.
Source: Jim Dolgonas, CENIC CENIC is Removing the Inter-Campus Barriers in California ~ $14M Invested in Upgrade Now Campuses Need to Upgrade.
Green Cyberinfrastructure on a Carbon-Constrained Planet Invited Talk Institute for the Future Board Meeting July 27, 2009 Dr. Larry Smarr Director, California.
Developing a North American Global LambdaGrid Dr. Larry Smarr Director, California Institute for Telecommunications and Information Technology Harry E.
Cal-(IT) 2 : A Public-Private Partnership in Southern California U.S. Business Council for Sustainable Development Year-End Meeting December 11, 2003 Institute.
Introduction to Calit2 Visit by NASA Ames February 29, 2008 Dr. Larry Smarr Director, California Institute for Telecommunications and Information Technology.
Innovative Research Alliances Invited Talk IUCRP Fellows Seminar UCSD La Jolla, CA July 10, 2006 Dr. Larry Smarr Director, California Institute for Telecommunications.
Using Photonics to Prototype the Research Campus Infrastructure of the Future: The UCSD Quartzite Project Philip Papadopoulos Larry Smarr Joseph Ford Shaya.
A High-Performance Campus-Scale Cyberinfrastructure For Effectively Bridging End-User Laboratories to Data-Intensive Sources Presentation by Larry Smarr.
Geosciences - Observations (Bob Wilhelmson) The geosciences in NSF’s world consists of atmospheric science, ocean science, and earth science Many of the.
Project GreenLight Overview Thomas DeFanti Full Research Scientist and Distinguished Professor Emeritus California Institute for Telecommunications and.
Digital Infrastructure in a Carbon-Constrained World Invited Presentation to the Committee on Science, Engineering, and Public Policy (COSEPUP) National.
The Role of Energy Efficient Cyberinfrastructure in Slowing Climate Change Community Alliance for Distributed Energy Resources Scripps Forum, UCSD La Jolla,
“ Collaborations Between Calit2, SIO, and the Venter Institute—a Beginning " Talk to the UCSD Representative Assembly La Jolla, CA November 29, 2005 Dr.
“The UCSD Big Data Freeway System” Invited Short Talk Workshop on “Enriching Human Life and Society” UC San Diego February 6, 2014 Dr. Larry Smarr Director,
“ OptIPuter Year Five: From Research to Adoption " OptIPuter All Hands Meeting La Jolla, CA January 22, 2007 Dr. Larry Smarr Director, California.
Southern California Infrastructure Philip Papadopoulos Greg Hidley.
High Performance Cyberinfrastructure Discovery Tools for Data Intensive Research Larry Smarr Prof. Computer Science and Engineering Director, Calit2 (UC.
“OptIPuter: From the End User Lab to Global Digital Assets" Panel UC Research Cyberinfrastructure Meeting October 10, 2005 Dr. Larry Smarr.
“ Building an Information Infrastructure to Support Microbial Metagenomic Sciences " Presentation to the NBCR Research Advisory Committee UCSD La Jolla,
Green cloud computing 2 Cs 595 Lecture 15.
The OptIPortal, a Scalable Visualization, Storage, and Computing Termination Device for High Bandwidth Campus Bridging Presentation by Larry Smarr to.
Presentation transcript:

The Growing Interdependence of the Internet and Climate Change Scientific Computing and Imaging (SCI) Institute Distinguished Lecture University of Utah April 30, 2010 Dr. Larry Smarr Director, California Institute for Telecommunications and Information Technology Harry E. Gruber Professor, Dept. of Computer Science and Engineering Jacobs School of Engineering, UCSD Twitter: lsmarr

Abstract Greenhouse gas (GHG) emissions continue their relentless rise, even though the global CO2 level is already considerably higher than it has been on earth for over two million years. The Information and Communication Technology (ICT) industry currently produces ~2-3 % of global GHG emissions and will nearly triple, in a business as usual scenario, from 2002 to On the other hand, the Climate Group estimates that transformative application of ICT to electricity grids, logistic chains, intelligent transportation and building infrastructure, and other social systems can reduce global GHG emissions by ~15%, five times ICT's own footprint! I will discuss three campus testbeds for exploring these complex tradeoffs. The first testbed is the NSF-funded GreenLight Project deployed at UCSD, which creates an instrumented data center that can guide users who wish to lower the energy cost of computation and storage. The second testbed is the campus itself, in which the move to centralized computing and storage can greatly reduce the GHG emissions of the current distributed set of clusters and storage. The third testbed is the global set of dedicated optical networks (operating at 10,000 Mbps), coupled to large tiled wall OptIPortals (with fractions of a billion pixels) and high definition (2 Mpixel/frame) or digital cinema (8Mpixel/frame), to create next generation "telepresence" systems for "sewing remote rooms together" as a way to reduce the need for transportation for national or global collaboration.

ICT Could be a Key Factor in Reducing the Rate of Climate Change Applications of ICT could enable emissions reductions of 15% of business-as-usual emissions. But it must keep its own growing footprint in check and overcome a number of hurdles if it expects to deliver on this potential.

Rapid Increase in the Greenhouse Gas CO 2 Since Industrial Era Began Little Ice Age Medieval Warm Period 388 ppm in 2010 Source: David JC MacKay, Sustainable Energy Without the Hot Air (2009) 290 ppm in 1900

Global Average Temperature Per Decade Over the Last 160 Years

Atmospheric CO 2 Levels for 800,000 Years and Projections for the 21 st Century /us-impacts/download-the-report Source: U.S. Global Change Research Program Report (2009) (MIT Study) (Shell Study)

Global Climatic Disruption Example: The Arctic Sea Ice Mean of all records transformed to summer temperature anomaly relative to the 1961–1990 reference period, with first-order linear trend for all records through 1900 with 2 standard deviations A pervasive cooling of the Arctic in progress 2000 years ago continued through the Middle Ages and into the Little Ice Age. It was reversed during the 20th century, with four of the five warmest decades of our 2000-year-long reconstruction occurring between 1950 and The most recent 10-year interval (1999–2008) was the warmest of the past 200 decades. Science v. 325 pp 1236 (September 4, 2009)

Arctic Summer Ice Melting Accelerating Relative to IPCC 2007 Predictions Source:

Global Climatic Disruption Early Signs: Area of Arctic Summer Ice is Rapidly Decreasing "We are almost out of multiyear sea ice in the northern hemisphere-- I've never seen anything like this in my 30 years of working in the high Arctic. --David Barber, Canada's Research Chair in Arctic System Science at the University of Manitoba October 29, sc_nm/us_climate_canada_arctic_1

Summer Arctic Sea Ice Volume Shows Even More Extreme MeltingIce Free by 2015? Source: Wieslaw Maslowski Naval Postgraduate School, AAAS Talk 2010

The Latest Science on Global Climatic Disruption An Update to the 2007 IPCC Report

The Global ICT Carbon Footprint is Significant and Growing at 6% Annually! the assumptions behind the growth in emissions expected in 2020: takes into account likely efficient technology developments that affect the power consumption of products and services and their expected penetration in the market in 2020

Reduction of ICT Emissions is a Global Challenge – U.S. and Canada are Small Sources U.S. plus Canada Percentage Falls From 25% to 14% of Global ICT Emissions by

The Global ICT Carbon Footprint by Subsector The Number of PCs (Desktops and Laptops) Globally is Expected to Increase from 592 Million in 2002 to More Than Four Billion in 2020 PCs Are Biggest Problem Data Centers Are Rapidly Improving

Making University Campuses Living Laboratories for the Greener Future

Increasing Laptop Energy Efficiency: Putting Machines To Sleep Transparently 16 Peripheral Laptop Low power domain Network interface Secondary processor Network interface Management software Management software Main processor, RAM, etc Main processor, RAM, etc Somniloquy Enables Servers to Enter and Exit Sleep While Maintaining Their Network and Application Level Presence Rajesh Gupta, UCSD CSE; Calit2

Desktops: Power Savings with SleepServer: A Networked Server-Based Energy Saving System –Power Drops from 102W to < 2.5W –Assuming a 45 Hour Work Week –620kWh Saved per Year, for Each PC –Additional Application Latency: 3s - 10s Across Applications –Not Significant as a Percentage of Resulting Session 17 StatePower Normal Idle State102.1W Lowest CPU Frequency97.4W Disable Multiple Cores93.1W Base Power93.1W Sleep state (ACPI State S3) Using SleepServers 2.3W Dell OptiPlex 745 Desktop PC Source: Rajesh Gupta, UCSD CSE, Calit2

PC: 68% Energy Saving Since SSR Deployment kW-Hours: kW-H Averge Watts:55.80 W Energy costs:$63.54 Estimated Energy Savings with Sleep Server: 32.62% Estimated Cost Savings with Sleep Server: $28.4 kW-Hours: kW-H Averge Watts:55.80 W Energy costs:$63.54 Estimated Energy Savings with Sleep Server: 32.62% Estimated Cost Savings with Sleep Server: $28.4 energy.ucsd.edu

Blueprint for the Digital University--Report of the UCSD Research Cyberinfrastructure Design Team Focus on Greener Data Storage and Data Curation –These Become the Centralized Components –Other Common Elements Plug In research.ucsd.edu/documents/rcidt/RCIDTReportFinal2009.pdf April 24, 2009

Source: Jim Dolgonas, CENIC Campus Preparations Needed to Accept CENIC CalREN Handoff to Campus

Current UCSD Prototype Optical Core: Bridging End-Users to CENIC L1, L2, L3 Services Source: Phil Papadopoulos, SDSC/Calit2 (Quartzite PI, OptIPuter co-PI) Quartzite Network MRI #CNS ; OptIPuter #ANI Lucent Glimmerglass Force10 Enpoints: >= 60 endpoints at 10 GigE >= 32 Packet switched >= 32 Switched wavelengths >= 300 Connected endpoints Approximately 0.5 TBit/s Arrive at the Optical Center of Campus. Switching is a Hybrid of: Packet, Lambda, Circuit -- OOO and Packet Switches

UCSD Campus Investment in Fiber Enables Consolidation of Energy Efficient Computing & Storage DataOasis (Central) Storage OptIPortal Tile Display Wall Campus Lab Cluster Digital Data Collections Triton – Petadata Analysis Gordon – HPC System Cluster Condo Scientific Instruments N x 10Gbe CENIC, NLR, I2DCN Source: Philip Papadopoulos, SDSC, UCSD

The GreenLight Project: Instrumenting the Energy Cost of Computational Science Focus on 5 Communities with At-Scale Computing Needs: –Metagenomics –Ocean Observing –Microscopy –Bioinformatics –Digital Media Measure, Monitor, & Web Publish Real-Time Sensor Outputs –Via Service-oriented Architectures –Allow Researchers Anywhere To Study Computing Energy Cost –Enable Scientists To Explore Tactics For Maximizing Work/Watt Develop Middleware that Automates Optimal Choice of Compute/RAM Power Strategies for Desired Greenness Partnering With Minority-Serving Institutions Cyberinfrastructure Empowerment Coalition Source: Tom DeFanti, Calit2; GreenLight PI

GreenLights Data is Available Remotely: Virtual Version in Calit2 StarCAVE Source: Tom DeFanti, Greg Dawe, Jurgen Schulze, Calit2 Connected at 50 Gb/s to Quartzite 30 HD Projectors!

Research Needed on How to Deploy a Green CI Computer Architecture –Rajesh Gupta/CSE Software Architecture, Clouds –Amin Vahdat, Ingolf Kruger/CSE CineGrid Exchange –Tom DeFanti/Calit2 Visualization –Falko Kuster/Structural Engineering Power and Thermal Management –Tajana Rosing/CSE Analyzing Power Consumption Data –Jim Hollan/Cog Sci Direct DC Datacenters –Tom Defanti, Greg Hidley MRI

New Techniques for Dynamic Power and Thermal Management to Reduce Energy Requirements Dynamic Thermal Management (DTM) Workload Scheduling: Machine learning for Dynamic Adaptation to get Best Temporal and Spatial Profiles with Closed-Loop Sensing Proactive Thermal Management Reduces Thermal Hot Spots by Average 60% with No Performance Overhead Dynamic Power Management (DPM) Optimal DPM for a Class of Workloads Machine Learning to Adapt Select Among Specialized Policies Use Sensors and Performance Counters to Monitor Multitasking/Within Task Adaptation of Voltage and Frequency Measured Energy Savings of Up to 70% per Device NSF Project Greenlight Green Cyberinfrastructure in Energy-Efficient Modular Facilities Closed-Loop Power &Thermal Management System Energy Efficiency Lab (seelab.ucsd.edu) Prof. Tajana Šimunić Rosing, CSE, UCSD CNS

Application of ICT Can Lead to a 5-Fold Greater Decrease in GHGs Than its Own Carbon Footprint Major Opportunities for the United States* –Smart Electrical Grids –Smart Transportation Systems –Smart Buildings –Virtual Meetings * Smart 2020 United States Report Addendum While the sector plans to significantly step up the energy efficiency of its products and services, ICTs largest influence will be by enabling energy efficiencies in other sectors, an opportunity that could deliver carbon savings five times larger than the total emissions from the entire ICT sector in Smart 2020 Report

Real-Time Monitoring of Building Energy Usage: UCSD Has 34 Buildings On-Line

Comparision Between UCSD Buildings: kW/sqFt Year Since 1/1/09 Calit2 and CSE are Very Energy Intensive Buildings

Power Management in Mixed Use Buildings: The UCSD CSE Building is Energy Instrumented 500 Occupants, 750 Computers Detailed Instrumentation to Measure Macro and Micro-Scale Power Use –39 Sensor Pods, 156 Radios, 70 Circuits –Subsystems: Air Conditioning & Lighting Conclusions: –Peak Load is Twice Base Load –70% of Base Load is PCs and Servers –90% of That Could Be Avoided! Source: Rajesh Gupta, CSE, Calit2

Contributors to the CSE Base Load IT loads account for 50% (peak) to 80% (off-peak)! –Includes machine room + plug loads IT equipment, even when idle, not put to sleep Duty-Cycling IT loads essential to reduce baseline 31 Source: Rajesh Gupta, UCSD CSE, Calit2

HD Talk to Australias Monash University from Calit2: Reducing International Travel July 31, 2008 Source: David Abramson, Monash Univ Qvidium Compressed HD ~140 mbps

Linking the Calit2 Auditoriums at UCSD and UCI with LifeSize HD for Shared Seminars September 8, 2009 Photo by Erik Jepsen, UC San Diego Sept. 8, 2009

First Tri-Continental Premier of a Streamed 4K Feature Film With Global HD Discussion San Paulo, Brazil Auditorium Keio Univ., Japan 4K Transmission Over 10Gbps-- 4 HD Projections from One 4K Projector 4K Film Director, Beto Souza Source: Sheldon Brown, CRCA, Calit2

The OptIPuter Project: Creating High Resolution Portals Over Dedicated Optical Channels to Global Science Data Picture Source: Mark Ellisman, David Lee, Jason Leigh Calit2 (UCSD, UCI), SDSC, and UIC LeadsLarry Smarr PI Univ. Partners: NCSA, USC, SDSU, NW, TA&M, UvA, SARA, KISTI, AIST Industry: IBM, Sun, Telcordia, Chiaro, Calient, Glimmerglass, Lucent Scalable Adaptive Graphics Environment (SAGE)

On-Line Resources Help You Build Your Own OptIPortal OptIPortals Are Built From Commodity PC Clusters and LCDs To Create a 10Gbps Scalable Termination Device

the AESOP Nearly Seamless OptIPortal Source: Tom DeFanti, 46 NEC Ultra-Narrow Bezel 720p LCD Monitors

High Definition Video Connected OptIPortals: Virtual Working Spaces for Data Intensive Research Source: Falko Kuester, Kai Doerr Calit2; Michael Sims, NASA NASA Interest in Supporting Virtual Institutes LifeSize HD Enables Collaboration Without Travel NASA Ames Mountain View, CA San Diego

Providing End-to-End CI for Petascale End Users Two 64K Images From a Cosmological Simulation of Galaxy Cluster Formation Mike Norman, SDSC October 10, 2008 log of gas temperature log of gas density

3D Stereo Head Tracked OptIPortal: NexCAVE Source: Tom DeFanti, Array of JVC HDTV 3D LCD Screens KAUST NexCAVE = 22.5MPixels

3D CAVE to CAVE Collaboration with HD Video Calit2s Jurgen Schulze in San Diego in StarCAVE and Kara Gribskov at SC09 in Portland, OR with NextCAVE Photo: Tom DeFanti

For Technical Details On OptIPuter Project and OptIPortals OptIPlanet: The OptIPuter Global Collaboratory – Special Section of Future Generations Computer Systems, Volume 25, Issue 2, February 2009

Follow My Talks and Tweets at lsmarr.calit2.net