ONYX® Series Fire Alarm Control Panels

Slides:



Advertisements
Similar presentations
EST3 Life Safety Platform
Advertisements

California Access Controls Inc Exciting features that are extremely easy to use Exciting features that are extremely easy to use Access Control.
Multi-Loop PID Controllers All Watlow® multi-loop time/temperature controllers offer auto-tuning which automatically sets PID control parameter for optimum.
Quest Web-Browser Interface. Home Page This is the Home Page of the Quest Browser Interface. This page will show the site information, and any active.
CERTIFICATON EN Wireless Fire Detection.
Industry Leading Audio Products. ClearOne’s installed and tabletop audio products deliver in-person sound quality Precision-Engineered Audio Products.
June 2010 At A Glance The Room Alert Adapter software in conjunction with AVTECH Room Alert™ devices assists in monitoring computer room environments as.
Security Systems BU Communication Systems Slide 1 Plena Voice Alarm System Commercial Presentation.
Remote Monitoring and Management Solutions ®
Leaders in Life. Safety. Technology. Interactive Firefighter’s Display.
ONYX Digital Voice Command
ProducTVity Station ™ October 2011.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
1 Fox Valley Fire & Safety’s Wireless Radio Network Our customers experience reduced monitoring costs; normally 25% or more. Eliminates expensive phone.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
1 ASPIRATING SYSTEMS TRAINING e-series. 2 Overview e-series model range ASD Software  NetTracer  Detector Monitor  PipeTracer.
Network Management Overview IACT 918 July 2004 Gene Awyzio SITACS University of Wollongong.
 A system consisting of a number of remote terminal units (or RTUs) collecting field data connected back to a master station via a communications system.
JADE™ Economizer Efficiency is simply a breeze. 2 Customer Requirements for Economizers Difficult to determine if the economizers are working Checkout.
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
ONYX Product Overview.
Iris Range : «Unconventional» conventional detectors.
Addressable Fire Alarms
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
Overview Presentation. Introduction Familiar package with enhanced functionality Bringing ‘NetVu Connected’ technology and advanced functionality to Digital.
SCADA and Telemetry Presented By:.
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
RP-2000 Series Deluge & Agent Releasing Panels
Fire Detection Presentation
G650 Generator Protection & Control System
Networking & Integration
JADE™ Economizer Efficiency is simply a breeze Use the player controls to advance.
NOTIFIER® ONYX® Series Overview
ENVIROTRAC: A Premier Chamber Monitoring and Data Acquisition System Envirotrac A Guided Tour.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
Atrium Fire Protection
DIGITAL VOICE COMMAND (DVC)
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
HP900 (ESP Protocol) Analogue Addressable Control Panels
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment, Enhanced Chapter 11: Monitoring Server Performance.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
Intelligent Control Panel SLC
KIDDE FIRE PROTECTION Vega Peer to Peer Networking.
NFS System Components & Installation.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment, Enhanced Chapter 11: Monitoring Server Performance.
Net Optics Confidential and Proprietary 1 Bypass Switches Intelligent Access and Monitoring Architecture Solutions.
1 Internal | ST/PRM2-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of.
Leaders in Life. Safety. Technology. ONYX ® Intelligent Sensing Introduction.
The Next Generation HSSD HART XL. Why Hart XL Aspirating Smoke Detection? l Earliest detection to enable business continuity l Extra time is required.
Flexible intelligent solid video management software.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Europe & Africa More Than.
Service Section Technical Training December 2005.
New product introduction:
PROGRAMMABLE LOGIC CONTROLLER
What can the Aerospace Industry Contribute to Very Early Fire Detection? Presented by: Stephen Lederer Marketing Manager, Honeywell, Inc.
EC-NetAX Supervision EC-BOSAX Web Building Controllers
Flame & Smoke Detection System Flame & Smoke Vision Detection is an intelligent vision-based analytics system which can timely detect suspicious fire or.
Overview Presentation MKT-DSRV-P- 001E. Product Overview Network based video transmission product with on-board digital recording Allows analogue fixed/PTZ.
C1300 advanced circular chart recorder
ABB i-bus® KNX The new Room Master RM/S 3.1 and RM/S 4.1
Fire Alarm Systems for Emergency Operations of Elevators
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
Programmable Logic Controllers (PLCs) An Overview.
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.

Honeywell Fire Systems Group RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks.
Presentation transcript:

ONYX® Series Fire Alarm Control Panels NOTIFIER Annual Distributor Conference October 3-6, 2004 ONYX® Series Fire Alarm Control Panels

NOTIFIER Annual Distributor Conference October 3-6, 2004 ONYX Series NFS-640 and NFS-3030 A family of fire alarm control systems Common options and accessories Common look and feel Backward compatible Upgrades are easy! The use of common modules including such items as panel modules, annunciators and network cards, between the ONYX panels will reduce cost for Notifier as fewer parts need to be manufactured. It will reduce cost for distributors since fewer parts need be stocked both in local warehouse and on service trucks Training time will be reduced for User’s including firefighters Existing customers are not left behind. A significant effort is put into maintaining backward compatibility. Back boxes

ONYX Series VeriFire Tools NOTIFIER Annual Distributor Conference October 3-6, 2004 ONYX Series VeriFire Tools PC-based offline programming tool Create and backup programs in the office or field Integrates with Excel Ability to create programs quickly

NOTIFIER Annual Distributor Conference October 3-6, 2004 NFS-640 One SLC, expandable to two FlashScan™ - 159 detectors/159 devices CLIP Protocol – 99 detectors/99 devices Isolated Loops for greater noise immunity Ground fault detection for each loop Integrated 6 amp power supply Four fully programmable NACs with sync

NOTIFIER Annual Distributor Conference October 3-6, 2004 NFS-640 Three display options 80 character 640 character No display Built-in network protocol 103 nodes supported Wire or fiber combinations

NOTIFIER Annual Distributor Conference October 3-6, 2004 The ONYX NFS-3030 NOTIFIER flagship panel Designed for medium to large systems. Up to ten SLC loop cards FlashScan™ - 159 detectors/159 devices CLIP Protocol – 99 detectors/99 devices

Adapts…To Any Situation Built-in expandability Modular design meets any application The NFS-3030 will grow to meet your expanding business needs

NOTIFIER Annual Distributor Conference October 3-6, 2004 Key Features Response times exceed worldwide code requirements ( < 3 sec ) Network compatible – 103 nodes

Key Features ONYX Intelligent Sensing algorithms Enhanced Walk Test options Supports the widest range of specialty sensors in the industry Auto-Program

Key Features Isolated SLC loops Supports up to 12 panel circuit modules Multiple suppression options Expanded software zones 4000 event non-volatile history file

Advanced Technology Flash memory...no need to change EPROM's Customers can receive upgrades via modem or web Reduces cost of labor and parts Database signature protection Prevents accidental data loss

NOTIFIER Annual Distributor Conference October 3-6, 2004 Display Options CPU-3030 display QWERTY keypad and 640-character LCD CPU-3030ND (no display Service LEDs for annunciation Switches for control Network only Visual would be nice. CPU3030D does not display network events (at this time).

160-Character Event Format ACKNOWLEDGED FIRE ALARM MAIN ELEVATOR LOBBY EAST WING FIFTH FLOOR Z005 SMOKE(PHOTO) 9:55:24A FRI SEP 06, 2002 L01D126 9:56:12A FRI SEP 08, 2000 • Up to 40 characters describe the event without abbreviations • Up to 52 custom characters plus type ID to aid in pinpointing the location of events • Variable time format with one second accuracy

Scroll Display Switches Provide the ability to view clearly events by type. Fire Alarm Security Supervisory Trouble Other

NOTIFIER Annual Distributor Conference October 3-6, 2004 History Features 4000 event non-volatile history file Protects against data loss Separate 1000 fire alarm event history Alarms are not overwritten by other events Advanced history filters allow sorting by event, time, date or address

NOTIFIER Annual Distributor Conference October 3-6, 2004 Reports Detector maintenance report. Cleanliness and existing condition of detection devices Installed point report. Provides quick lookup information Allows printing functions without need for attached PC Detectors, Modules, Panel Circuits, Zones, etc.

FlashScan® (US Pat 5,539,389) A high-speed digital polling protocol Maintains sensor data for analysis and trending Support new panel features with no need to replace sensors

NOTIFIER Annual Distributor Conference October 3-6, 2004 FlashScan Enhanced Walk Test options Basic/One-man test reduces labor Advanced test bypasses detector initialization saving time between tests Multicolor LEDs LEDs indicate device address and testing status LEDs flash Address: Input Modules and Detector in red; Output Modules in green Steady green for Tested devices Basic Inhibits CBE Adv performs CBE

Programming Options Fully keypad programmable Changes can be made without a PC Auto-Program learns devices and assigns default parameters New installations are protected in minutes

Programming Options VeriFire Tools Create programs in the office Test and compare programs Communicate with all network panels from any network location

NOTIFIER Annual Distributor Conference October 3-6, 2004 Software Zones 1000 General zones Simplified linking of inputs to outputs 1000 Logic zones Allows conditional I/O linking such as AND, OR, NOT, ANYx 100 Trouble zones Alter programming parameters based on specific fault conditions Explain new Boolean functions.

NOTIFIER Annual Distributor Conference October 3-6, 2004 Suppression Options Multiple Releasing zones Protect against ten independent hazards Three sophisticated Cross-zone options Allows flexibility for any application Four Abort options Designed to comply with all jurisdictions Explain three cross-zone options and abort options.

Optional Annunciators

NOTIFIER Annual Distributor Conference October 3-6, 2004 Expanded ACS Protocol 96 pts / address Reduces cost per annunciator point Enable / disable Provides faster access to daily or repetitive tasks Selectable LED colors Meets any local code requirements Programmable LED color Red/green/yellow Speaker control option Matches XPIQ groupings On-board EOL resistors Compatible with existing annunciators

Supports Smoke Control NOTIFIER Annual Distributor Conference October 3-6, 2004 Supports Smoke Control FSCS mode NFPA-92A, 90B HVAC mode NFPA 90A

NOTIFIER Annual Distributor Conference October 3-6, 2004 Smoke Control Station Up to four modules/group Three position toggle switches On / Off / Auto Control On Control Off Monitor On Monitor Off SCS-8

ONYX Digital Voice Command

System Definition ONYX Digital Voice Command [DVC] is NOTIFIER's new digital audio system with: Audio evacuation Paging Firefighter's telephone Eight channels of quality audio for: Live emergency paging Simultaneous broadcasting of multiple stored messages

System Definition ONYX DVC broadcasts simultaneous, unique messages throughout your entire facility or select designated areas ONYX DVC provides critical information or instruction in an emergency ONYX DVC ensures the right people have the right information at the right time during the following: Smoke Fire Intrusion Chemical spill Weather event

True Digital for Unparalleled Clarity From message storage to amplifier, everything is digital to eliminate distortion Up to 32 Digital Audio Amplifiers can be connected to a DVC center Each DAA is configurable as a primary or backup amplifier DAA is a powerful 50 Watts in either 25 Volt or 70 Volt versions with four outputs per amplifier.

Large Number of Audio Zones Larger applications can be accommodated with additional DVC centers Each networked DVC adds support for another 32 DAA series amplifiers Applications requiring hundreds of zones can be created by networking additional DVC centers over NOTI•FIRE•NET™

Network for Survivability and Scalability Multiple DVC centers can be networked together with seamless integration into NOTI•FIRE•NET NOTI•FIRE•NET with DVC provides: Added survivability and scalability Multiple command center support System expansion

Paging Over the Fire Alarm Network Every DVC has an interface with NOTI•FIRE•NET One channel audio over NOTI•FIRE•NET allows for network-wide live paging Allows one DVC center to page over the whole system when multiple DVC centers are networked.

Multiple Paging Options Preprogrammed multiple paging groups are standard with DVC New Group Paging Options Page Active EVAC areas Page Active ALERT areas Page Inactive areas All Call Option to page Inactive Areas to simply notify occupants of a potential emergency. Each group of occupants receives customized information

DVC Keypad for Simple Group Paging

Firefighter’s Telephone Up to five channels of simultaneous Firefighter's Telephone operation Crucial scene assessment information can be gathered more quickly for: Improved response efforts Increased safety of both building occupants and fire service personnel

Large Memory Capacity Memory capacity of up to 1000 audio sequences storage 16 minutes standard of stored audio messages expandable to 32 minutes Store customized audio sequences for any potential emergency/evacuation messages.

Customized Audio Messages Comes with a standard library of messages Message library speeds installation and simplifies maintenance Record, edit, and distribute your own custom messages or tones as standard .WAV format audio files No more locked-down libraries and no need to change memory chips

Microphone Options Local paging microphone option and Remote Microphone (RM-1) option. Flexibility to page on site or from remote location to further enhance communications and life safety.

Backup Alarm Alarm Bus backup activation in the event of communication loss between (DAA) and DVC center. Two minute backup message storage Alarm Bus initiates backup Emergency Message

ONYX® Intelligent Sensing

ONYX® Intelligent Sensing Solves the most challenging and unique detection problems Offers the best protection from incipient fires by integrating: Sophisticated sensor technology Powerful fire alarm control panel processing ONYX Intelligent Sensing benefits: Minimized nuisance alarms Rapid, intelligent response Substantially reduced the cost of downtime due to false alarms or fire related damage High-sensitivity without compromising stability or reliability

ONYX Intelligent Sensing Defined Technologies Detector Sensitivity Adjust Maintenance Warnings Self-optimizing Pre-alarm Cooperative Detection Supervisory Smoke ID Sensors VIEW Acclimate Plus HARSH

ONYX Intelligent Sensing NOTIFIER Annual Distributor Conference October 3-6, 2004 ONYX Intelligent Sensing Programmed into every NOTIFIER ONYX Series Panel Unique panel intelligence exclusive to NOTIFIER For enhanced protection, use specialty sensors like VIEW Acclimate HARSH

Detector Sensitivity Adjust NOTIFIER Annual Distributor Conference October 3-6, 2004 Detector Sensitivity Adjust Ability to program each and every detector’s settings, choosing from nine sensitivity levels Nine sensitivity settings Provides options for controlling sensitivity levels to meet various environmental conditions. Can be programmed manually or can alternate automatically between daytime and night-time settings Nine distinct pre-alarm levels, based on pre-determined levels of alarm In any room there is a “back-ground” level of airborne particulate detected by any sensor. Transient signals: dust, steam, pollen, lint, humidity etc. Sensitivity Settings Part of the building fire system design challenge is to match the sensor threshold to the ambient “back-ground” level. Therefore, the designer is given the option of sensitivity settings based on the threshold of various backgrounds.

NOTIFIER Annual Distributor Conference October 3-6, 2004 Sensitivity Levels “Clean” vs. “Dirty” Environments DIRTY Alarm Too Quickly 9 - (Process Plant) 8 - (Laundry) 7 - (Industrial) 6 - (Mercantile) 5 - (Residential) 4 - (Office) CLEAN Sensitivity Settings The labels used for sensitivity settings of 1-9 suggest these settings are set by building type, or use. However, the real application is to use settings for different environments within a building based upon the back-ground levels. 3 - (Theater) 2 - (Schools) 1 - (Hospital) Alarm Too Slowly

Self-Optimizing Pre-Alarm NOTIFIER Annual Distributor Conference October 3-6, 2004 Self-Optimizing Pre-Alarm A unique mode where the detector ‘learns’ its normal environment by measuring peak analog readings over a period of time ONYX panel intelligence sets the Pre-Alarm levels just above these normal peaks. Extremely sensitive pre-alarm capability with protection against nuisance alarms Reduce false pre-alarms due to spikes

Three Maintenance Alerts NOTIFIER Annual Distributor Conference October 3-6, 2004 Three Maintenance Alerts Determines when dust accumulation reaches an unacceptable level that can compromise detector performance Control panel indicates one of three maintenance warning levels: Low Threshold Maintenance Required Maintenance Urgent All sensors react to build up of dust, lint, grime, humidity and aging electronics. This change in chamber value over time is called “drift.” Devices become more sensitive or less sensitive over time.

Three Maintenance Alerts NOTIFIER Annual Distributor Conference October 3-6, 2004 Three Maintenance Alerts Precise report on detector condition Upper Chamber Threshold Lower Chamber Threshold Maintenance Alert Low Chamber Value Maintenance Urgent

NOTIFIER Annual Distributor Conference October 3-6, 2004 Cooperative Sensing Exclusively from NOTIFIER Combination of up to three sensors in reaching the alarm decision Fire alarm control panel looks at the values from adjacent devices rather than input from only one device

NOTIFIER Annual Distributor Conference October 3-6, 2004 Cooperative Sensing There are three generally accepted fire signatures; heat, smoke and light Only NOTIFIER looks at a fourth signature: uniform smoke spread Adds “distance” to the equation Smoke acts like a gas and will evenly disperse Increased response to uniformly distributed smoke Sampling over a wider area is more stable Reject isolated sources of false signals the panel looks at the values from adjacent devices rather than within one housing. The advantage to this approach is that it adds the element of distance into the decision making process. This acts to reduce response to spurious nuisance smoke, but reacts more quickly to uniform smoke spread.   In extensive testing it was learned that smoke acts like a gas and will spread uniformly in an area if it is not physically contained. This creates a better response signal in two ways. First, spurious nuisance smoke, for example from a cigarette, dilutes as it spreads. By the time it reaches the next sensor, it is too insignificant to be detected. On the other hand, smoke from a fire will spread evenly and the presence of smoke at adjacent devices is a strong indicator of a real fire situation.

Supervisory Smoke ID: Commercial Applications NOTIFIER Annual Distributor Conference October 3-6, 2004 Supervisory Smoke ID: Commercial Applications Shift to Preventative Approach Where the probability of unwarranted alarms is high Where smoke sensitivity is set to an extremely low level for use as a maintenance alert. Allows smoke sensors to quickly sense overheating equipment prior to serious damage occurring. Can be annunciated at an indicator panel in just the maintenance department Will not sound general alarm Supervisory smoke provides the ability to use the most sensitive settings on sensors to create a maintenance intervention, without causing general alarm and without summoning the fire department. The main concept in applying this approach is to “close the gate before the horse gets out.” By sensing the problem in the very early stages, maintenance people can be alerted to adjust, repair or replace the equipment before the fire occurs. High sensitivity smoke sensing is becoming more main-stream, combined with supervisory mode. Local area servers, telephone equipment, lab equipment and dozens of other areas are being provided high sensitivity supervision in order to allow the operator to intervene before serious damage is sustained. There is substantial return on investment just from reduced downtime when systems start to overheat.

VIEW Very Intelligent Early Warning NOTIFIER Annual Distributor Conference October 3-6, 2004 VIEW Very Intelligent Early Warning VIEW laser system has an advanced laser light source and patented optical design. Addressable, spot detector Replaces complex and expensive aspirating systems in critical environments. Sensitivity that is 10 to 50 times higher than present photoelectric technology. Adjustable sensitivity of pre-alarm and alarm levels from 1.0%/ft. to .03%/ft.. VIEW offers: very early warning individual point annunciation total supervision simplified maintenance.

VIEW Very Intelligent Early Warning NOTIFIER Annual Distributor Conference October 3-6, 2004 VIEW Very Intelligent Early Warning VIEW is ideal for critical applications where even a trace of undetected smoke is unacceptable: Network server rooms Telephone facilities Cleanrooms Mission critical areas Museums and archives Records Storage Equipment Rooms Archives

HARSH Hostile Area Smoke Head NOTIFIER Annual Distributor Conference October 3-6, 2004 HARSH Hostile Area Smoke Head Replaces heat detectors in hostile environments (e.g. dirty & non-direct water spray) A small fan draws air and smoke into a photoelectric sensing chamber Filter removes unwanted particulates and water mist without removing smoke. Helps protect the detection chamber and electronics in damp and moisture-rich environments. Easy-to-replace filter Zoos, Mechanical rooms, Processing plants, etc.

HARSH Hostile Area Smoke Head NOTIFIER Annual Distributor Conference October 3-6, 2004 HARSH Hostile Area Smoke Head No longer compromise on detection in critical areas that are dirty or wet. Paper, lumber and textile mills Food processing plants Packaging areas (corrugated dust) Laundry facilities Zoos, stables, barns Zoos, Mechanical rooms, Processing plants, etc.

NOTIFIER Annual Distributor Conference October 3-6, 2004 Acclimate Plus Acclimate Plus constantly monitors ambient conditions Adjusts detection parameters and alarm thresholds automatically Provides maximum detection and reduced nuisance alarms Combines thermal and photoelectric technologies to maximize detection across a broad range of fire types. Photo-Thermal design Chamber sensitivity increases with heat. Heat only option. Freeze warning. Ideal Acclimate Plus Applications: Office areas Schools Healthcare facilities, Hospitals Hospitality – Hotels/Motels Restaurants

Thank you