A Hard X-Ray Coherent Scattering Beamline for NSLS-II Alec Sandy, X-Ray Science Division Argonne National Laboratory & SAXS?

Slides:



Advertisements
Similar presentations
P4 Shutter Review May, 2005 P4 – ID Movable Beam Stop and Integral Shutters Presented by K. Beyer and T. Lutes.
Advertisements

NSLS-II Soft X-ray Undulator Beamlines
NSLS-II Stability Workshop – User Requirements Working Group – Day 1 Stability Requirements for soft x-ray coherent microscopy/imaging -- C. Jacobsen :
1 BROOKHAVEN SCIENCE ASSOCIATES Can the optics get to 1-nm? Hanfei Yan NSLS-II, Brookhaven National Laboratory.
User requirements Session chair K.Evans-Lutterodt Speakers: Jorg Maser N. Simos D.Arena P.Northrup C. Sanchez-Hanke.
Stanford Synchrotron Radiation Lightsource Sources and Optics for XAS Apurva Mehta.
Ultrafast XUV Coherent Diffractive Imaging Xunyou GE, CEA Saclay Director : Hamed Merdji.
1 BROOKHAVEN SCIENCE ASSOCIATES National Synchrotron Light Source II Damping Wiggler Beamline: XAS Preliminary Design Summary Paul Northrup January 16th,
Beam stability requirements: experience from the NSLS X1A STXMs Chris Jacobsen Department of Physics & Astronomy Stony Brook University, NY, USA
Imaging x-ray generation and Scattering Tabletop soft x-ray coherent imaging microscopes.
Bingxin Yang High resolution effective K September 22-23, 2004 High-Resolution Effective K Measurements Using Spontaneous.
ERL & Coherent X-ray Applications
Aymeric Robert XCS 11/12/2008 SLAC National Accelerator Laboratory 1 X -ray C orrelation S pectroscopy Instrument Aymeric.
John Arthur Photon October 27, Photon Systems Overview John Arthur SLAC.
Science Program and Team Leaders Update Brian Stephenson LUSI XCS Scientific Team Leader XCS Final Instrument Design Review June 17, 2009.
John Arthur Photon April 20, 2006 Photon Systems Update John Arthur SLAC Photon Systems Manager.
John Arthur PIXEL Project April 7, 2005 Status of the Proposed PIXEL Project John Arthur SSRL/SLAC Photon Instrumentation.
I. K. Robinson, SSRL Imaging Workshop, October Phasing of Three Dimensional Diffraction Patterns from Finite-Sized Objects Ian Robinson Ivan Vartanyants.
AWAKE Electron Spectrometer Design Simon Jolly 4 th September 2012.
Effective lens aperture Deff
Introduction to Synchrotron Radiation Instrumentation
Ultra-Low Emittance Storage Ring David L. Rubin December 22, 2011.
Environmental Sciences Department BNL Environmental Sciences Dept. and EnviroSuite: from NSLS to NSLS-II Jeff Fitts July 18, 2007 Environmental Research.
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Argonne National Laboratory Office of Science U.S. Department.
1 BROOKHAVEN SCIENCE ASSOCIATES Lonny Berman and Dario Arena, NSLS Summary The present built-out NSLS-II design includes: 30 bending magnet ports, each.
Electromagnetic radiation sources based on relativistic electron and ion beams E.G.Bessonov 1.Introduction 2.Spontaneous and stimulated emission of electromagnetic.
XPCS at the APS: Implementation and Operations
1 BROOKHAVEN SCIENCE ASSOCIATES National Synchrotron Light Source II Nanoprobe Beamline K. Evans-Lutterodt November 8th, 2007.
Recent Progress in X-ray Emittance Diagnostics at SPring-8 S. Takano, M. Masaki, and H. Sumitomo * JASRI/SPring-8, Hyogo, Japan SES, Hyogo, Japan *
BROOKHAVEN SCIENCE ASSOCIATES BIW ’ 06 Lepton Beam Emittance Instrumentation Igor Pinayev National Synchrotron Light Source BNL, Upton, NY.
MACS –a New High Intensity Cold Neutron Spectrometer at NIST February 17, 2003Timothy D. Pike1 Developing MACS A Third Generation Cold Neutron Spectrometer.
Soft Coherent Scattering and Imaging Chris Jacobsen, Stony Brook Cecilia Sánchez-Hanke, NSLS.
1 BROOKHAVEN SCIENCE ASSOCIATES Experimental Facilities John Hill Director, NSLS-II Experimental Facilities Division NSLS-II User Workshop July 17, 2007.
1 2. Focusing Microscopy Object placed close to secondary source: => strong magnification The smaller the focus, the sharper the image! Spectroscopy, tomography.
Advanced Virgo Optical Configuration ILIAS-GW, Tübingen Andreas Freise - Conceptual Design -
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-to-NSLS-II beamline transition plan Outline Reasons, Scope, Criteria, Further input, Timeline Transition plan, Beamline.
SAXS/WAXS Conversion for Beamline Engineering Review.
Coherent X-ray Diffraction (CXD) X-ray imaging of non periodic objects Campi G., De Caro L., Giannini C., Guagliardi A., Margonelli A., Pifferi A.
Introduction to Synchrotron Radiation
1nm R&D plan K. Evans-Lutterodt Contributions from:
Coherent X-ray Diffraction (CXD) X-ray imaging of non periodic objects Campi G., De Caro L., Giannini C., Guagliardi A., Margonelli A., Pifferi A.
Stability Requirements for Superconducting Wiggler Beamlines
1 BROOKHAVEN SCIENCE ASSOCIATES National Synchrotron Light Source II Hard Coherent X-Ray Beamline Lonny Berman EFAC Meeting, October 4 th, 2007 with contributions.
Chris Hall Monash Centre for Synchrotron Science Monash University, Melbourne, Australia.
1 BROOKHAVEN SCIENCE ASSOCIATES The use of fast-modulated elliptically polarized soft x-rays in the detection of small polarization signals Cecilia Sánchez-Hanke.
A users viewpoint: absorption spectroscopy at a synchrotron Frithjof Nolting.
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Overview Satoshi Ozaki Director, Accelerator Systems Division NSLS-II Project March 27, 2007.
ELECTRON MOVING AT CONSTANT VELOCITY
LCLS Brian Stephenson, Materials Science Division, Argonne National Laboratory Steven Dierker, Department of Physics, University of Michigan Simon Mochrie,
Proposed NSLS X13B Microdiffraction Instrument Source & Optics James M. Ablett National Synchrotron Light Source.
Coherent X-ray Diffraction (CXD) X-ray imaging of non periodic objects.
Status of the Diamond Light Source upgrade EuCARD2 topical workshop Barcelona, 23 April 2015 R. Bartolini. A. Alekou, M. Apollonio, R. Fielder, I. Martin,
1 BROOKHAVEN SCIENCE ASSOCIATES Lonny Berman EFAC May 10 th 2007 ID Beamline Optics and Damping Wigglers.
1 BROOKHAVEN SCIENCE ASSOCIATES A Wiggler Beamline for XAS at NSLS-II Paul Northrup NSLS-II Project and Environmental Sciences Department Brookhaven National.
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
Brookhaven Science Associates U.S. Department of Energy Chi-Chang Kao National Synchrotron Light Source Brookhaven National Laboratory Recent Developments.
LEPP, the Cornell University Laboratory for Elementary-Particle Physics, has joined with CHESS to become the Cornell Laboratory for Accelerator-based Sciences.
1 BROOKHAVEN SCIENCE ASSOCIATES Vibrations effect on 1nm focussing K. Evans-Lutterodt NSLS-II VTG Januaury
Highlights of science of USR Yuhui Dong BSRF, IHEP, CAS 2012/10/29.
1 BROOKHAVEN SCIENCE ASSOCIATES 12th International Workshop on Accelerator Alignment September 10-14, 2012 Fermilab, Batavia, Illinois, U.S.A NSLS-II Girder.
APS Upgrades / Changes Higher brightness (~x100) Higher coherent fraction (~x100) Superconducting undulator 3-Pole Wiggler may be used to replace Bending.
Polarization Dependence in X-ray Spectroscopy and Scattering
SLS-2 – Ugrade of the Swiss Light Source
Introduction to Synchrotron Radiation
X-ray Correlation Spectroscopy (WBS 1.4) Aymeric Robert
LUSI XPCS Status Team Leader: Brian Stephenson (Materials Science Div., Argonne) Co-Leaders: Karl Ludwig (Dept. of Physics, Boston Univ.), Gerhard Gruebel.
Optics John Arthur, SLAC & William W. Craig, LLNL April 24, 2002
PIXEL Project Status John Arthur Photon Instrumentation for
Coherent X-ray Imaging Instrument WBS 1.3
X-ray Correlation Spectroscopy Instrument
Presentation transcript:

A Hard X-Ray Coherent Scattering Beamline for NSLS-II Alec Sandy, X-Ray Science Division Argonne National Laboratory & SAXS?

2 Acknowledgements Design to be discussed today represents work primarily performed by: –Scott Coburn, Brookhaven National Laboratory –Simon Mochrie, Yale University –Ian Robinson, University College London Many helpful conversations with: –Larry Lurio, Northern Illinois University –Brian Stephenson, Argonne National Laboratory –Mark Sutton, McGill University

3 Outline Beamline Mission Supported Techniques Lay of the Land NSLS-II Strengths Beamline Requirements Design Philosophy Conceptual Design Possible Discussion Items

4 Beamline Mission Application of hard (7–12 keV) coherent x-rays to the study of nanoscale dynamics and structure of complex materials –Equilibrium dynamics and fluctuations about the evolution to equilibrium in colloids, polymers, membranes, concentrated proteins, glasses, … –3-D imaging of microscopic non-crystalline objects such as catalytically active materials, cavities within steel, defect structures in magnetic multilayers, cellular imaging Mark A. Pfeifer, Garth J. Williams, Ivan A. Vartanyants, Ross Harder, and Ian K. Robinson, “Three-dimensional mapping of a deformation field inside a nanocrystal,” Nature 442, 63 (2006)Nature 442, 63 (2006) O. G. Shpyrko, E. D. Isaacs, J. M. Logan, Yejun Feng, G. Aeppli, R. Jaramillo, H. C. Kim, T. F. Rosenbaum, P. Zschack, M. Sprung, S. Narayanan, and A. R. Sandy; "Direct measurement of antiferromagnetic domain fluctuations," Nature 447, 68Nature 447, 68

5 Supported Techniques Techniques to be employed –X-ray photon correlation spectroscopy (XPCS) or x-ray intensity fluctuation spectroscopy (XIFS) X-ray analog of dynamic light scattering –Coherent x-ray diffraction (CXD) Coherent x-rays and intensity over-sampling to determine the nanoscale structure of micron sized crystals via phase retrieval and inversion –Coherent x-ray diffraction imaging (CXDI) Coherent x-rays and intensity over-sampling to determine the nanoscale structure of non-periodic objects via phase retrieval and inversion – Lensless imaging, ptychography, CXDI –SAXS –Imaging Phase contrast imaging Diffraction enhanced imaging

6 Lay of the Land ESRF (6 GeV) –General purpose beamline evolving to XPCS and CXD(I) specialization Small Q XPCS, considerably less large Q XPCS and CXDI: ID-10 APS (7 GeV) –Dedicated XPCS beamline but not (yet) CXD/CXDI Small Q XPCS and considerably less large Q XPCS: 8-ID CXD (large Q) but limited GU program: 34-ID CXDI (small Q): ? SPRing 8 –Little activity SLS (2.4 GeV) –SAXS, XPCS, CXDI: cSAXS Sophisticated and advanced detector program but lower energy ring and shorter beamlines Petra III (6.0 GeV) –Tandem endstations: large Q XPCS, CXD and XPCS and CXDI Planning phase: 2009–2010 completion—long straights and beamlines Diamond (3.0 GeV) –USAXS/XPCS branch, CXDI/CXD multiplexed with full-field imaging: I m beamline length Planning phase: 2010–2011 completion

7 NSLS-II Strengths Unprecedented brightness –Both XPCS and CXD remain signal starved techniques CXD “improves” linearly with brightness – Measurement times from hours to minutes XPCS “improves” quadratically with brightness – 30× more incident intensity → 1,000× faster dynamics Existing strong community in soft condensed matter science and a relatively local XPCS community Soft and hard x-ray coherent x-ray scattering Existing, innovative detector program coupled to activities on the experiment floor –Leverage for XPCS and CXD detector development Learn from others’ mistakes and capitalize on several years of operational experience at other 3 rd generation coherence-based beamlines –ESRF ID10 (XPCS) and APS 8-ID (XPCS) both originally built to satisfy broad scientific mission

8 Beamline Requirements Coherent flux! Stability –Parasitically fluctuating signals contaminate XPCS time autocorrelation analysis –Parasitically fluctuating signals significantly complicate phase retrieval Beamtime –Brilliance-hungry techniques so maximize the beamtime delivered to experimental stations Long beamline –High demagnification focusing for CXD and large Q XPCS –Reduced flux density for radiation sensitive samples Long small angle XPCS station –“Smart” detectors likely to have larger pixels than today’s Minimal energy tunability –Above energy of large resonant enhancements

9 Design Philosophy KISS – Keep it simple, stupid! –Coherent flux Select the coherent portion of the x-ray beam as far upstream as possible to eliminate power mitigation issues downstream – Secondary source/pinhole Preserve the coherence delivered by the undulator and reduce parasitic scattering – Minimize the number of beamline optics –Stability – Minimize the number of beamline optics –Beamtime Beam comprised of many horizontal coherence lengths—split the beam and feed independent end stations –Limited/infrequent energy tunability Compatible with split beam operations

10 Conceptual Design-Secondary Source/Pinhole Secondary source or pinhole –Extract, in the horizontal, only a coherent fraction of the x-ray beam Undulator S1S1 S2S2 D1D1 D2D2 Sample Secondary Source (  27 m) Pixel size = p

11 Conceptual Design-Secondary Source/Pinhole Coherent diffraction over-sampling –λD 2 /S 2 > 2p Far field –S 2 /D 2 > λ / S 2 Coherent illumination –S 2 < λD 1 /S 1 Use entire source –2σ x < (S 1 + S 2 ) D 0 / D 1 Undulator S1S1 S2S2 D1D1 D2D2 Sample Secondary Source (  27 m) Pixel size = p ItemCXD, large Q XPCS Value XPCS, CXDI Value Max. sample to detector distance 3 m10 m S2 size  100 µm  30 µm Maximum S1 secondary source size  80 µm Pixel resolution  20 µm  80 µm

12 Conceptual Design-Beam Splitting 2 secondary sources or pinholes in the FOE –Multiplexed operation creates twice as much beamtime –Small horizontal-bounce mirrors used to extract coherent fraction of the beam (in the horizontal) –2× mirror deflections and long beamline creates sufficient horizontal clearance CXS FOE Beam Splitting Concept-Plan View Hi-pass filter Slit Mirrors = secondary source or pinhole ½ Slit WB Stop Shutter White beam (WB) Power- reducing aperture Pink beam 12 mrad

13 Conceptual Design-Optical Layout Simplified version of the optical layout –Undulator Future upgrade to tandem devices (rather than canted) –Standard operating energy goal 12 keV Low K value → less power Less sample radiation damage –High demagnification optics Kinoform lenses or KB mirrors

14 Conceptual Design-Floor Layout Stations –Large Q XPCS and CXD station High demagnification optics Diffractometer –Small Q XPCS and CXDI station Pinhole “SAXS” Vertically focusing optics –SOE Monochromators × 2 Optics? –FOE

15 Conceptual Design-Small Q XPCS and CXDI Station Requirements –  50 m from the source and 15 m long × 4 m wide –Pinhole SAXS set-up –3 or more heavy-duty motorized support tables 1.High demagnification optics and collimating/guard apertures –Vertical focusing to reduce the vertical coherence length –Collimating and guard apertures –All in vacuum where possible 2.Sample environment –Flow cells –In vacuum positioning 3.Long flight path and detector support assembly –Smart detectors –On-the-fly compression, on-board correlation

16 Conceptual Design-Large Q XPCS and CXD Station Requirements –  100 m from source and 6 m long × 6 m wide –Optics table High demagnification nanofocusing optics – KB mirror, kinoform lens, zone plate –Large load capacity precision diffractometer and/or large load hexapod with ≤ 3 m detector arm –Optical microscopy/fluorescence detectors for sample alignment and registration –Small pixel, high dynamic range direct detection area detector Alio Industries Silicon kinoform lens K. Evans-Lutterodt et al., Opt. Express

17 Some Possible Issues for Discussion Long beamline –Conceptual design only but significant rethinking required if not allowed Mirrors or crystals for beam splitting Split beam vis-à-vis operational support –Canted versus split beam beamlines Which “imaging” techniques, if any, belong as part of the beamline? –Lensless imaging/ptychography/coherent diffractive imaging –Phase contrast imaging –Diffraction enhanced imaging Vertical focusing further upstream –Large vertical correlation can not be used so eliminate from the start? Energy gap –≥ 7 keV for hard coherent x-ray scattering versus ≤ 2 keV for soft x-ray coherent scattering/imaging Sample radiation damage Detectors, detectors, detectors! –Now is the time to worry about detectors