Stephen Schuh Vacuum Controls Hardware 27 February 2006 LCLS Vacuum Controls Hardware Meeting 27 February 2006.

Slides:



Advertisements
Similar presentations
RavensNest 60 Channel Intelligent Video Solution The RavensNest is an enhanced video command and control platform that transforms any centralized analog.
Advertisements

26/2704 Vacuum Feature What is vacuum Vacuum in industry
Sputter Stand Safety Specifics Electrical Hazards High Voltage : Electrical power is required for the high voltage supply, gauging, system controller and.
Henrik Loos LCLS FAC Meeting 27 October RF Gun Status LCLS Facility Advisory Committee Meeting October 26, 2005 Mechanical.
BCAL Interlock System US BCAL Chiller US BCAL MPOD 1 US BCAL PLC Pulsed Output from Flow meter to PLC From US BCAL cooling loop US BCAL MPOD 1 RS485 from.
TMS Co., Ltd Vacuum GAUGE Vacuum Gauge Selection.
Module 4: Analog programming blocks. Module Objectives Analyze a control task that uses analog inputs. Connect a potentiometer to LOGO! controller and.
File/ 1 Primary colours Secondary colours Remember to change file name 28pt Ariel bold 18pt Ariel bold l Distributed PID Control and I/O What is.
6/2/2015EIFast Workshop Hamburg, May A Klystron Interlock for the XFEL RF Stations Holger Leich DESY Hamburg and Zeuthen  Joint project: DESY Hamburg.
20 Feb 2002Readout electronics1 Status of the readout design Paul Dauncey Imperial College Outline: Basic concept Features of proposal VFE interface issues.
1. Pump down the chamber from the atmosphere pressure 2. Using RHEED to obtain diffraction images 3. Open the RHEED chamber or venting from high vacuum.
Stewart Shen October 27, LCLS-XTOD Gas Attenuator LCLS FAC Meeting October 27, 2005 Stewart Shen, Keith Kishiyama and Marty Roeben.
Chapter 8 Output Modules.
ION PUMP HVFT / Connectors
ANNEX. WP 1.04, Michael Ebert2MAC PETRA-III Review Meeting, DESY,29th November 2006 Sandblasted Center Conductor of a Cavity Input Coupler R a =
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
High-Vacuum Technology Course
Stephen Schuh Vacuum Controls Final Design 6 April 2006 Injector Vacuum Controls Hardware Final Design Review 6 April 2006.
ISOLDE Vacuum Controls (CERN-GSI WS), S. Blanchard TE-VSC-ICM UNICOS Vacuum Objects Specifications Review Sebastien Blanchard TE/VSC Interlocks,
2500 Series ® Compact I/O System. Where does Compact I/O fit? – When 2500 Series ® “Classic” system is too large to fit the application – When fewer I/O.
Steve Lewis XTOD Controls FDR 13 March 2008 XTOD Vacuum Controls Final Design Review Steve Lewis/Keith Kishiyama 13 March 2008.
Digital measurement system for the LHC klystron high voltage modulator D. Valuch, A. Mikkelsen, G. Ravida, O. Brunner.
A* candidate for the power supply Wiener MPOD-LV crate w/ remote control only (except for local on/off switch) Type “EC LV” Front or rear connections (reverse.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
MICE CM February 08Jean-Sébastien GraulichSlide 1 Detector DAQ Hardware Status o Introduction o Preliminary list o Plan for action o Summary Jean-Sebastien.
Rd 3 - Electronics 1.Ohm’s Law 2.Potential Divider 3.Resistor in Series and Parallel - Application of Ohm’s Law 4. Operational Amplifier (Comparator and.
AdV Vacuum system changes, 04Mar2010, NDRC option Preliminary Cryotrap_NI Link or tube? Cryotrap_NE Link Cryopump SR? Cryopump PR? Zeolites/27K/77K (or.
PWC Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
LHC ARC Commissioning report during LS1 Agenda: VRGPE documentation (former VRJGE) Active Penning modification By-Pass Valves modification LHC ARC commissioning.
Technical Training. 1 Configuration: 2558 Analog Input Module 1. Select voltage or current input mode for each channel 3. Select digital filtering, offset.
LKr Calorimeter Control and monitoring R. Fantechi 19/02/2010 R. Fantechi.
Storing and Organizing Data. Why Do I Need to Understand How Data Is Represented? In order to install, program,maintain, and troubleshoot today’s PLCs,
Stephen Schuh Vacuum Controls SCR and 16 November 2005 Vacuum Controls System Concept Review and Preliminary Design Review.
RAD hardening Half of dual HV supply or quarter of quad HV supply w breakout Output connector Input connector Ion Pump: RAD area Standard cable RAD-hard.
Polarized Injector Status QWeak Collaboration Meeting February 1, 2010 P. Adderley, J. Clark, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman, R. Suleiman,
Vacuum Workshop on Vacuum Systems for Synchrotron Light Sources, Barcelona, Vacuum Technology, 12 th and 13 th September 2005 L. Schulz Introduction Pumps.
Accelerator Laboratory 1 CFS Review of Asian Region (S. Fukuda) June 1/ Hz Operation in DRFS HLRF System KEK S. Fukuda.
Adapting Muon Endcap UF/PNPI HV system for GEM V. Barashko, A. Korytov, A. Madorsky, G. Mitselmakher University of Florida/Physics N. Bondar, V. Golovtsov,
AdV Vacuum system changes, 23Feb2011 Central area vacuum equipment SVC 2 (mini) towers 1 new HV tower (Inj) DT,IB from HV->UHV towers (with additional.
OD HV Upgrade Hans Berns Jeff Wilkes U. of Washington 10/14/01.
Steve Lewis Gas Attenuator 11 December Instrumentation & Controls Steve Lewis 11 December 2006 LCLS Gas Attenuator Preliminary.
Kévin Pepitone 1CLIC project meeting, CERN, December 1st, 2015 Kevin PEPITONE, BE-RF Drive Beam Injector Gun.
Laser Heater Controls Overview 21 August 2008 Matt Boyes Laser Heater Controls Design Overview EPICS IOC Team Meeting Matt Boyes.
1394b Gigabit Ethernet The transmitter Group (G8) Design Proposal Mubin Ansari Zubair P. Siddiqui February 14, 2002.
NSLS Vacuum Experience Eugene J. Hu National Synchrotron Light Source Brookhaven National Laboratory Upton, NY USA September 12-13, 2005 (prepared.
Managed by UT-Battelle for the Department of Energy SCL Vacuum Control System Upgrade Derrick Williams
Steve Lewis Controls: Vacuum 5 April, 2005 UCRL-PRES LCLS Week 5 April, 2005 Steve Lewis Vacuum Standards.
New product introduction:
DC photogun vacuum characterization through photocathode lifetime studies Marcy L. Stutzman, Philip Adderley, Joseph Grames, Matthew Poelker, Ken Surles-Law.
Magnum Chiller Plant Manager
MRDA Wiring diagram S-BUS Module ID setting button ballast L N DC0-10V dimming voltage Control DC Maximum current :100mA 6 relay switch 16A 6 channel.
AdV Vacuum system changes, Feb2010 ‘New stations’ generic Layout preliminary Cryotrap_NICryotrap_NE Cryotrap_WI Cryotrap_WE Cryotrap_DT ? Cryotrap_IB ?
April 2005OLAV Workshop Diamond Vacuum Controls Hugo S Shiers.
Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.
Design summary Status of the development & production - test run with S3a and S3b prototype - performance tests To do list for production & development.
Danish Ali Nawaz 1CLIC workshop 2016 Danish Ali NAWAZ, BE-ABP LEETCHI: Drive Beam Electron Source Automation Control.
Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
2500 Series® Compact System Components
More performance in more applications
Tunnel Magnetic system power supply №1 HVM+Heat Power supply HVT SM
XFEL Vacuum System Commissioning
NI Data Acquisition (DAQ) Wiring and Connections
PLC Hardware Components.
Undulator Vacuum System
RF Local Protection System
Power Supply Control for BEPCII
Undulator Vacuum System
DOE Review 11 May 2005 Stephen A. Lewis
724 Temperature Calibrator
DOE Review 11 May 2005 Stephen A. Lewis
Presentation transcript:

Stephen Schuh Vacuum Controls Hardware 27 February 2006 LCLS Vacuum Controls Hardware Meeting 27 February 2006

Stephen Schuh Vacuum Controls Hardware 27 February 2006 Outline Gamma Ion Pump Power Supply Configuration of supply MKS Cold Cathode / Pirani Gauge Controller Configuration of controller Granville-Philips Hot Filament / Pirani Gauge Controller Which controller should we use? New or old?

Stephen Schuh Vacuum Controls Hardware 27 February 2006 Ion Pump Power Supply: Gamma MPC

Stephen Schuh Vacuum Controls Hardware 27 February 2006 Gamma MPC Configuration – page 1 Two independent high voltage channels Each channel has two King’s connectors; total of four 5.6 kV output Positive polarity Positive polarity for noble diode type pumps (Note: StarCell pumps would require negative polarity) Medium HV module Starting capacity of 200W, 100mA Full operation of 10 l/s to 200 l/s Larger pumps if well roughed or under high vacuum

Stephen Schuh Vacuum Controls Hardware 27 February 2006 Gamma MPC Configuration – page 2 Power source: US 110V No TSP or NEG option Remote control and status: Relay input for HV on/off (High Voltage Enable connector) Analog outputs for pump voltage and current (analog connector) Relay outputs for four process control set points RS232 commands for all other settings: view or modify set point configuration, view power supply status, etc.

Stephen Schuh Vacuum Controls Hardware 27 February 2006 Cold Cathode / Pirani Gauge Controller: MKS 937A

Stephen Schuh Vacuum Controls Hardware 27 February 2006 MKS 937A Configuration – page 1 Power source: 120VAC, 60Hz Measurement unit: Torr Gauge configuration: Four gauges Base: Cold cathode, fast response (15 msec) Slot 1: Cold cathode, fast response (15 msec) Slot 2: Dual convection-enhanced Pirani

Stephen Schuh Vacuum Controls Hardware 27 February 2006 MKS 937A Configuration – page 2 Remote control and status: Turn cold cathode gauges on/off Relay outputs for four process control set points (1 per gauge) Each gauge has 2 analog outputs for pressure, buffered and logarithmic Each cold cathode / Pirani pair has 1 combined analog output for pressure

Stephen Schuh Vacuum Controls Hardware 27 February 2006 Hot filament gauge controller Two hot filament gauges located near gun More hot filament gauges may be installed in x-ray end stations; nobody knows how many Question: Buy two more of the standard SLAC controllers, or buy a newer model?

Stephen Schuh Vacuum Controls Hardware 27 February 2006 Hot filament gauge controller: Two options Granville-Philips 307: SLAC standardGranville-Philips 370: newer controller $2550~$3500 Special SLAC configuration for gauge on/off: Two inputs for gauge on and gauge off, rather than one toggle input Can be ordered with or without SLAC gauge on/off modifications No gauge-specific calibration Accuracy ~10% Gauge-specific calibration Accuracy ~5% Switch filaments by rotating plug in tunnel Switch filaments from controller Spares exist at SLACNo spares at SLAC