Spot Filming Cinefluorography Fluoro Room Shielding Radiation Areas.

Slides:



Advertisements
Similar presentations
Advanced Biomedical Imaging Lecture 3
Advertisements

Quality Control in Diagnostic Radiology
X-Ray Beam Restrictors
Digital Radiography.
{ Projection Radiography Chapter 5 (in more detail)
FLUOROSCOPY QUALITY CONTROL Rev 2014.
1 Matakuliah: U0173 / FOTOGRAFI 1 PHOTOGRAPHY 1 Introduction to Manual Camera.
Chapter 17 The Grid So far we have discussed how kVp, patient size and collimation impact scatter radiation. As the part size and kVp increase, scatter.
Radiographic Grids II By Professor Stelmark.
Resident Physics Lectures
MAMMO QC – covered in week 8
Analyzing the Image Density. Density Overall blackening of the image.
X-RAYS IN MOTION “Viewing dynamic studies of the human body”
DESIGNING FOR RADIATION PROTECTION. TUBE HOUSING  REDUCES LEAKAGE TO LESS THAN 100 mR PER HOUR AT A DISTANCE OF ONE METER FROM HOUSING  One meter is.
Digital FLUORO Summer 2008.
Lecture 4 Beam restricting Devices, their Use and Maintenance
Radiation Exposure and Risk John Hamaty. Evaluation of Radiation Exposure Levels in Cine Cardiac Catheterization Laboratories American Association of.
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
Conventional and Computed Tomography
Quality Control Rad T 110.
RAD 350 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion Invented by Thomas Edison.
DIGITAL FLUOROSCOPY.
F luoroscopy. 2 Fluoroscopy system 3 Different fluoroscopy systems  Remote control systems Not requiring the presence of medical specialists inside.
Control of Scatter Radiation
Quality Control.
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
Radiation Monitoring and Protection
Dr Mohamed El Safwany, MD.
Fluoro & Rad Protection Review Questions For WEB RT 255 wk 7/8 1.
Fluoroscopy Equipment. Introduction Fluoro: is dynamic radiographic examination Fluoroscopy is primarily domain of the radiologist The role of radiographer.
Rad Tech 265 More Digital Imaging. Digital Fluoroscopy Radiation dose –Patient dose for DF is significantly less than conventional fluoro At 7.5 pulses/second.
RAD 254 Chapter 15 Radiographic Technique 4 primary exposure factors are: kVp, mA, time, distance.
Fluoroscopy Q&A Robert L. Metzger, Ph.D..
Angiographic facilities Tortorici Chapter 11. Designed around exam table 500 sq feet min. (25 x 20) 60 sq feet in control room Wide doors, (multiple)
Appendix H: Chapter 40: Fluoroscopy
What is being tested? (kVp, mA, mAs, mR?) What is the purpose of the HVL test? If an x-ray tube does not pass the HVL test what is done to correct the.
RHB SYLLABUS on Fluoroscopy & Radiation Protection
Radiation Sources in medicine diagnostic Radiology
Radiographic Equipment
Designing for Radiation Protection. Design Standards for Radiation Protection – Leakage Radiation.
Grids George David Associate Professor Department of Radiology
RAD 150 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic (motion)
RAD 354 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
Gamma Shielding Calculations
Stacy Kopso, M.Ed., R.T.(R)(M).  Xray photon loses energy and changes direction  Responsible for most of the scatter that fogs the image  Related to.
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
Protection1 Radiation Protection. Protection2 BENEFITS VS. ADVERSE EFFECTS.
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
Radiation Protection RTMR 284 CHAPTER 20 PART II.
RADIATION PROTECTION 04/12/2016.
Diagnostic Equipment Quality Control
Ch 36 Radiation Protection Design
Protection of Patients
Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist
Factors Effecting the Production
Fluoroscopy: Dynamic Imaging Systems
Resident Physics Lectures (Year 1)
Fluoroscopy Dynamic Image Recording Systems
Mobile Fluoroscopy Based on:
Mobile Fluoroscopy Based on:
Fluoroscopy Dynamic Image Recording Systems
Resident Physics Lectures (Year 1)
Fluoroscopy Static Image Recording Systems
Fluoroscopy Static Image Recording Systems
Fluoroscopic Image Quality Considerations
Fluoroscopic Image Intensifier Image Production
Fluoroscopy: Static Image Recording Systems
Mobile Fluoroscopy.
Fluoroscopic Image Quality Considerations
Presentation transcript:

Spot Filming Cinefluorography Fluoro Room Shielding Radiation Areas

Spot Filming Spot Film Cassettes Uses conventional radiographic cassettes. Bypasses image intensifier for direct exposure. Uses mA > 100 X that of photofluoro camera.

Spot Filming Spot Film Cameras Image the output phosphor of II. Same mA as fluoroscopy (1-3 mA typically). Exposes one frame/exposure. Uses 70, 90, or 100/105 mm film size. As you increase film size, increase image quality and patient dose. Method of choice for spot filming compared to spot film cassettes.

Spot Filming Total Overframing Overframing Exact Framing Underframing Framing (matching II output size to film area) Total Overframing Overframing Exact Framing Underframing

Framing and Patient Dose Reduction Underframing Exact Framing Int. image = small dimension of frame No part of image lost Only 58% of frame used Fluoro image < frame Should be avoided P. 31

Framing and Patient Dose Reduction Total Overframing Overframing Image circle > short film dimension Part of image lost Circular image = diameter of frame All of film used 39 % of image wasted

Cinefluorography The process of recording fluoro images on movie (cine) film. Film sizes 16 and 35 mm The larger the film size, the greater the resolution and greater the patient dose.

Film Size 12.6 mm 30 mm

Cinefluorography Synchronization Framing Frequency Camera shutter timed to the same frequency as the x-ray pulses. Shutter open only during x-ray pulses. Framing Frequency Number of exposed frames/second. Divisions or multiples of 60 Hz line rate. Examples: 7.5, 15, 30, 90, 120 frames/second.

35 mm Cine Camera

Shutter Synchronization

Cinefluorography, cont’d Framing Frequency Patient Exposure Directly proportional to framing frequency. P. 30

Cinefluorography, cont’d Framing Frequency Patient Exposure Conversions 2000 mR/frame X 1 mR/1000 mR = 2 mR/frame 2 mR/frame X 30 frames/second X 60 seconds/minute = 3,600 mR/minute 3,600 mR/minute X 1 R/1000 mR = 3.6 R/minute P. 30

Cinefluorography, cont’d F-number Number indicating the ratio of the focal length of the camera lens to the diameter of the lens. F-number = Focal Length of Lens/Diameter of Lens The smaller the f-number = more light into the camera and less patient exposure. P. 30

Focal length of lens

Focal length of lens Lens Diameter F-num = 50 mm / 20 mm = F 2.5

F-numbers Iris diaphragm The smaller the f-number - the larger the aperture opening. The larger the f-number - the smaller the aperture opening.

Depth of field

QA Concerns Spot Film and Cine Cameras Beam and image size match within 3 % of SID A small aperture (large f-number) will require greater patient exposure but result in low noise image. Patient entrance exposures of 50 - 150 rads or more. P. 110

Structural Fluoro Room Shielding Provisions Barriers Primary A barrier to attenuate the useful beam to the required degree. Secondary Used to attenuate stray (scattered and leakage) radiation to the required degree. Useful Beam Radiation that passes through window, aperture, or cone. Stray Radiation Leakage and secondary radiation. No useful purpose. p. 121

Primary/Secondary Barriers Exception would be in R/F room where all walls would be a primary barrier. (Source: Principles of Imaging Science and Protection. Thompson, Hattaway, Hall, Dowd, 1994)

Structural Fluoro Room Shielding Provisions Tube Leakage Maximum exposure @ 1 meter is 0.1 R/hour. Half-Value Layer (HVL) Thickness of material that reduces beam exposure rate by half of original value. Tenth-Value Layer (TVL) Thickness of material that reduces beam exposure rate to 1/10 of original value.

Tube Leakage 1 meter Maximum permissible = 0.1 R/hr. @ 5 mA

Radiation Areas Radiation Area High Radiation Area Controlled Area Any area where whole body dose could be = or > 0.005 rem/1 hr. at 30 cm from source. High Radiation Area Any area where whole body dose could be = or > 0.1 rem/1 hr. at 30 cm from source. Controlled Area Any area where radiation safety rules enforced. Unrestricted Area An area in which access is neither limited nor controlled.

Radiation Areas, cont’d. Restricted Area Any area where access is limited by the licensee to protect individuals against undue risks from radiation exposure.

Unrestricted/Controlled Areas

Unrestricted Area Controlled Area

QC-Semi-annual checks Spot film Film Cine Processor Cameras Flare Exposure Timer Image Lag Film-Screen Contac t QC-Semi-annual checks mAs Linearity Image Quality Grid Exposure Reproducibility Alignment Phototimers Linearity Cine Film Processor Spot Film- Cine Image Camera Exposures Cine Film Exposure Spot Film Beam Limitation Resolution – Distortion Film

Video Recording of Fluoroscopic Image Video Tape Video Disc Laser Disc CD Electronic Radiography DVD

Video Tape Advantages Instant Replay No increase in patient exposure Disadvantages Poor image quality Fixed framing rate- 30 frames/sec.

Video Disc (Electronic Radiography) Advantages Last image freeze “sticky fluoroscopy” Instantaneous imaging Short exposure times 95% dose reduction during fluoro Variable framing rates – 1-30 frames/sec. Multiple image storage Random access of images Disadvantages None significant

The End