SOI detector Geant4-based studies to characterise the tissue-equivalence of SOI and diamond microdosimeteric detectors, under development at CMRP S. Dowdell,

Slides:



Advertisements
Similar presentations
M. Glaser, G. Guatelli, B. Mascialino, M. Moll, M.G. Pia, F. Ravotti Simulation for LHC Radiation Background Optimisation of monitoring detectors and experimental.
Advertisements

Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
The Vin č a Institute of Nuclear Sciences, Belgrade, Serbia * Universita degli studi di Bologna, DIENCA, Italia Radovan D. Ili}, Milan Pe{i}, Radojko Pavlovi}
Energy deposition and neutron background studies for a low energy proton therapy facility Roxana Rata*, Roger Barlow* * International Institute for Accelerator.
Parameterized Shower Simulation in Lelaps: a Comparison with Geant4 Daniel Birt, Amy Nicholson.
S. Guatelli, M.G. Pia – INFN Sezione di Genova Geant4-SPENVIS Workshop 3-7 October 2005 Leuven, Belgium Radioprotection.
S. Guatelli IEEE 2004 – NSS - Rome Dosimetry for Interplanetary Missions: the Geant4 REMSIM application S. Guatelli 1, P. Nieminen 2, M.G. Pia 1 IEEE NSS,
MARS15 Simulations of the MERIT Mercury Target Experiment Fermilab March 18, Neutrino Factory and Muon Collider Collaboration meeting Sergei.
MONTE-CARLO TECHNIQUES APPLIED TO PROTON DOSIMETRY AND RADIATION SAFETY F. Guillaume, G. Rucka, J. Hérault, N. Iborra, P. Chauvel 1 XXXV European Cyclotron.
Radiation Exposure, Dose and Relative Biological Effectiveness in Medicine Background Image:
Brad Oborn G4NAMU, Philadelphia 2010 G4 Applications From Australian Users B. Oborn 1,2, A. Rosenfeld 1, S. Guatelli 1 1 Centre for Medical Radiation Physics.
Reduced Dose of Proton CT Compared to X-Ray CT in Tissue-Density Variation Sensitivity T. Satogata, T. Bacarian, S. Peggs, A.G. Ruggiero, and F.A. Dilmanian.
Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck.
Radiation Dosimetry Dose Calculations D, LET & H can frequently be obtained reliably by calculations: Alpha & low – Energy Beta Emitters Distributed in.
1 M.G. Pia et al. The application of GEANT4 simulation code for brachytherapy treatment Maria Grazia Pia INFN Genova, Italy and CERN/IT
Validation of the Bremsstrahlung models Susanna Guatelli, Barbara Mascialino, Luciano Pandola, Maria Grazia Pia, Pedro Rodrigues, Andreia Trindade IEEE.
TRAINING COURSE ON RADIATION DOSIMETRY: Instrumentation 1 – Gas detectors / Part 1 Anthony WAKER, University of Ontario Instutute of Technology Wed. 21/11/2012,
Geant4-INFN (Genova-LNS) Team Validation of Geant4 electromagnetic and hadronic models against proton data Validation of Geant4 electromagnetic and hadronic.
TRAINING COURSE on radiation dosimetry:
Maria Grazia Pia Systematic validation of Geant4 electromagnetic and hadronic models against proton data Systematic validation of Geant4 electromagnetic.
Budker Inst. of Physics IHEP Protvino MEPHI Moscow Pittsburg University.
Photon and Energy Fluence
Low-energy EM group : validation of low energy EM models Geant Low Energy EM Physics working group January 2009 CERN.
2 nd ANNUAL ARDENT WORKSHOP Quality assessment of hadrontherapy fields with TEPCs Paolo Colautti, INFN 2 nd Annual ARDENT Workshop, Milano, October.
Workshop on Physics on Nuclei at Extremes, Tokyo Institute of Technology, Institute for Nuclear Research and Nuclear Energy Bulgarian Academy.
Centre de Toulouse Radiation interaction with matter 1.
Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation.
Milestones M5 and M6 Mid-Term Review, October 2013M. Silari – ARDENT overview1 M5: comparison of detector technologies (WP1) M6: choice of detector technology.
G. Bartesaghi, 11° ICATPP, Como, 5-9 October 2009 MONTE CARLO SIMULATIONS ON NEUTRON TRANSPORT AND ABSORBED DOSE IN TISSUE-EQUIVALENT PHANTOMS EXPOSED.
Maria Grazia Pia Simulation for LHC Radiation Background Optimisation of monitoring detectors and experimental validation Simulation for LHC Radiation.
A General Purpose Brachytherapy Software Simulation + Analysis (isodose calculation) 2/10/2002 Geant4 Workshop CERN Susanna Guatelli Univ. and INFN Genova.
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
VALSIM status J. Apostolakis, V. Grichine, A. Howard, A. Ribon EUDET meeting, 11 th Sept 2006.
A silicon microdosimeter for radiation quality assessment (1) INFN, Sezione di Milano, via Celoria 16, Milano, Italy. (2) Politecnico di Milano,
Monte Carlo methods in ADS experiments Study for state exam 2008 Mitja Majerle “Phasotron” and “Energy Plus Transmutation” setups (schematic drawings)
Passive detectors (nuclear track detectors) – part 2: Applications for neutrons This research project has been supported by the Marie Curie Initial Training.
Effects of Surrounding Materials on Proton-Induced Energy Deposition in Large Silicon Diode Arrays Christina L. Howe 1, Robert A. Weller 1, Robert A. Reed.
TUDelft-IRI-ST A new Tissue-Equivalent Proportional Counter design M. Farahmand, A.J.J. Bos, J. Huizenga and C.W.E. van Eijk Radiation Technology Group,
Latifa Elouadrhiri Jefferson Lab Hall B 12 GeV Upgrade Drift Chamber Review Jefferson Lab March 6- 8, 2007 CLAS12 Drift Chambers Simulation and Event Reconstruction.
16 October, TRAINING COURSE ON EXPERIMENTAL MICRODOSIMETRY Principle of silicon- based microdosimetry Stefano Agosteo 1,2, Andrea Pola 1,2 1 Politecnico.
1 Background radiation studies in LHCb with GAUSS/Geant4 Giuseppe G. Daquino PH/SFT.
Geant4 User Workshop, Catania, Italy, 15th October, 2009
Determining Radiation Intensity
Improvement of the Monte Carlo Simulation Efficiency of a Proton Therapy Treatment Head Based on Proton Tracking Analysis and Geometry Simplifications.
F. Foppiano, M.G. Pia, M. Piergentili
Recent Studies on ILC BDS and MERIT S. Striganov APD meeting, January 24.
ESTRO, Geneva 2003 The importance of nuclear interactions for dose calculations in proton therapy M.Soukup 1, M.Fippel 2, F. Nuesslin 2 1 Department of.
3/2003 Rev 1 II.2.9a – slide 1 of 25 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Part IIQuantities and.
A silicon microdosimeter for radiation quality assessment (1) INFN, Sezione di Milano, via Celoria 16, Milano, Italy. (2) Politecnico di Milano,
New Geant4 Electromagnetic Physics Developments for Ion Therapy Applications Toshiyuki Toshito 1, Alexander Bagulya 2, Anton Lechner 3,4, Vladimir Ivanchenko.
Implementation of a New Monte Carlo Simulation Tool for the Development of a Proton Therapy Beam Line and Verification of the related Dose Distributions.
1 Giuseppe G. Daquino 26 th January 2005 SoFTware Development for Experiments Group Physics Department, CERN Background radiation studies using Geant4.
Se Byeong Lee, Ph.D Chief Medical Physicist Proton Therapy Center in NCC, Korea.
N_TOF EAR-1 Simulations The “γ-flash” A. Tsinganis (CERN/NTUA), C. Guerrero (CERN), V. Vlachoudis (CERN) n_TOF Annual Collaboration Meeting Lisbon, December.
Monte Carlo methods in spallation experiments Defense of the phD thesis Mitja Majerle “Phasotron” and “Energy Plus Transmutation” setups (schematic drawings)
From Microdosimetry to Nanodosimetry
INTERCOMPARISON P3. Dose distribution of a proton beam
Geant4 REMSIM application
Summary of hadronic tests and benchmarks in ALICE
Development and characterization of the Detectorized Phantom for research in the field of spatial fractionated radiation therapy. D. Ramazanov, V. Pugatch,
Introduction Goal: Can we reconstruct the energy depositions of the proton in the brain if we are able to reconstruct the photons produced during this.
Arghya Chattaraj, T. Palani Selvam, D. Datta
Witold Matysiak (University of Florida Proton Therapy Institute)
Radioprotection for interplanetary manned missions
1. Introduction Secondary Heavy charged particle (fragment) production
Hadronic physics validation of Geant4
Geant4 physics validation: Bragg Peak
The Hadrontherapy Geant4 advanced example
G. A. P. Cirrone1, G. Cuttone1, F. Di Rosa1, S. Guatelli1, A
The Geant4 Hadrontherapy Advanced Example
Presentation transcript:

SOI detector Geant4-based studies to characterise the tissue-equivalence of SOI and diamond microdosimeteric detectors, under development at CMRP S. Dowdell, S. Guatelli, P. Lazarakis, and A. B. Rosenfeld Centre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, NSW, Australia

Silicon microdosimetry Microdosimetry measures energy deposition on a cellular scale Silicon On Insulator (SOI) microdosimeters have been under investigation at CMRP for the past ten years as a possible alternative to tissue equivalent gas counters Applications in radiation protection in space and dosimetry in medical physics Collaboration of CMRP with Australian Nuclear Science and Technology Organisation University of New South Wales, Australia First generation SOI detector Second generation SOI detector

Geant4 for microdosimetry Characterisation of SOI microdosimeter Response of the detector in radiation fields of interest Proton therapy Fast neutron therapy Radiation protection in terrestrial, aviation and space Chord length distribution Tissue equivalence Methodology to convert microdosimetric spectra in silicon to tissue

Geant4 for microdosimetry Advanced capability in physics and geometry modelling Good agreement between experimental and simulated microdosimetric spectra A. B. Rosenfeld, A. J. Wroe, I. M. Cornelius, M. Reinhard, and D. Alexiev, “Analysis of inelastic interactions for therapeutic proton beams using Monte Carlo simulation”, IEEE Trans. Nucl. Sci, vol. 51, no. 6, pp. 3019-3025, 2004. A. B. Rosenfeld, A. Wroe, M. Carolan, and I. Cornelius, “Method of Monte Carlo simulation verification in hadrontherapy with non-tissue equivalent detectors”, Rad. Prot. Dosim., vol. 119, pp. 487-490, 2006. D. A. Prokopovich, M. I. Reinhard, I. M. Cornelius, and A. B. Rosenfeld, “SOI microdosimetry for mixed field radiation protection”, Rad. Meas., vol. 43, pp. 1054-1058, 2008.

Characterisation of SOI microdosimeters by means of Geant4 Chord length distribution Tissue-equivalence of silicon

Chord Length Distribution study H = 2 µm R1 = 3 µm R2 Chord Length Distribution study The detector concept is exposed to a uniform isotropic field of infinite straight lines 2 µm device 10 µm device Mean chord length: (2.103 ± 0.014) µm Mean chord length: (3.36 ± 0.02) µm Geant4 Log scale Log scale Geant4

Characterisation of SOI microdosimeters by means of Geant4 Chord length distribution Tissue-equivalence of silicon S. Guatelli, et al., “Tissue equivalence correction in silicon microdosimetry for protons characteristic of the LEO space environment”, IEEE Trans. Nucl. Sci., vol. 55, pp. 3407-3413, 2008

Geant4 simulation How to convert Si based microdosimetric measurements to tissue Experimental set-up Blue tracks: proton tracks Red tracks: e- tracks Microdosimetric energy deposited spectra along the proton Bragg peak in a simplified model of the Si SV in a cylinder of water Experimental set-up 50, 100, 150, 200 MeV proton pencil beam Electromagnetic and hadronic physics active for primary and secondary particles Calculate the energy deposit per event in the detector Water phantom (size= 10 m) 10 μm 5 μm D Si detector

Geant4 simulation: Physics List Electromagnetic physics: G4 Standard Package Threshold of production of secondary particles: 1 micrometer Hadronic physics for protons, neutrons and pions: Geant4 elastic process Parameterised Elastic Model Inelastic hadronic processes Bertini cascade model Fission and capture processes Inelastic hadronic scattering for deuteron, triton and α particle Low Energy Parameterized model The Binary Ion Model was active in the case of other ions

Proton Bragg peak in water 50 MeV 100 MeV 250 MeV 150 MeV The result of the study is the factor C, corresponding to the best agreement of the energy deposition spectra in the Si and in the water microdosimeter sites. For a water cylinder with height h and diameter d , the required scaling is C∙h, C∙d of silicon.

Results Statistical analysis by means of Kolmogorov- Smirnov test Energy deposition spectra resulting from a 50 MeV at 2 cm depth in the water phantom. (raising part of Bragg curve) Linear coefficient C* = (0.56 ± 0.03) was determined to convert microdosimetric spectra from silicon to water for incident proton energies between a few MeV and 250 MeV For a water cylinder with height h and diameter d, the required scaling is C*·h, C*·d of silicon Energy deposition spectra resulting from a 50 MeV proton beam at 2.1 cm depth in the water phantom. (Bragg peak)

Work in progress We are investigating a general methodology to convert silicon microdosimetric spectra to tissue equivalent spectra in any arbitrary mixed radiation field Study of the tissue equivalency of diamond Diamond proposed as alternative to silicon for microdosimetry because of better tissue-equivalency

Secondary neutrons in proton therapy Secondary neutrons are generated through nuclear interactions of the primary beam with the beamline and inside the patient Neutrons deposit energy through secondary charged particles, often of high LET, and are important for second cancer calculations Accurate determination of secondary neutron dose delivered in tissue is vital Using different phantoms may lead to different secondary neutron doses Geant4-based study of secondary neutron dose in different materials S. Dowdell, et al., “Tissue equivalence of phantom materials for neutron dosimetry in proton therapy”, Med Phys, accepted for publication The materials considered were: A150, brain, cranium, lucite, muscle, water

Geant4 simulations Neutron absorbed dose scored in sensitive volumes (2.5 x 25.0 x 0.5 mm3) throughout different materials Absorbed dose (D) combined with radiation weighting factor (wR) to give dose equivalent H H = wR x D 150 MeV p beam (5 cm x 5cm) Physics list based on previous study by Zacharatou Jarlskog and Paganetti*: G4EmStandard G4BinaryCascade G4UHadronElasticProcess Cut in material = 1mm Cuts in sensitive volume = 1mm * C. Zacharatou Jarlskog, and H. Paganetti, "Physics Settings for Using the Geant4 Toolkit in Proton Therapy", IEEE Trans. Nucl. Sci., 55, 1018- 1025, (2008) Simulation setup

Results Magnitude of secondary neutrons doses out of field is less than along central axis, but larger differences exist between phantom and tissue Secondary neutron dose in proton therapy is sensitive to the materials traversed affecting out of field measurements where neutrons dominate the total dose equivalent Neutron absorbed dose (a) and dose equivalent (b) along the central axis

Next step: in progress How different are microdosimetric spectra obtained by silicon microdosimeter in different phantom materials irradiated with the same proton beam? How similar are phantom materials to tissue of interest for modelling of radiobiological properties of the proton beam?

Geant4 simulation experimental setup 150 MeV and 250 MeV proton beams simulated Energy deposition spectra collected in Si sensitive volume (red sphere), at multiple depths in different phantoms and tissues The energy deposition spectra will be converted to microdosimetry spectra in Si Proton pencil beam Si Phantom R1 = 10m R2 = 3mm R3 = 10mm Geant4 simulation experimental setup Significance of any variation in the spectra will be ascertained using the Kolmogorov- Smirnov statistical test This study will show any effect that the phantom material has on a microdosimetric level

Summary At the CMRP we are intensively using Geant4 as a simulation toolkit to characterise novel detectors in radiation fields of interest for medical physics and radiation protection Thank you