Jingfneg Jiang1, Kevin Sunderland1, Gouthami Chintalapani2,

Slides:



Advertisements
Similar presentations
Usefulness of velocity profiles based on 3D cine PC MR used as boundary conditions for computational fluid dynamics of an intracranial aneurysm : investigation.
Advertisements

Dynamic model of a drop shot from an inkjet printer.
Validation of Blood Flow Simulations in Intracranial Aneurysms Yue Yu Brown University.
C OMPUTATIONAL F LUID D YNAMIC M ODEL OF A RTERIOVENOUS F ISTULA A NASTOMOSIS TO S TUDY THE E FFECTS OF V ESSEL S IZE AND P RESSURE G RADIENT ON THE P.
Fully Automatic Blood vessel Branch Labeling Lei Chen Supervisors: Ir. Jan Bruijns Prof. Bart M. ter Haar Romeny.
Computational Mechanics & Numerical Mathematics University of Groningen Multi-scale modeling of the carotid artery G. Rozema, A.E.P. Veldman, N.M. Maurits.
Author(s): Johnston, S Claiborne MD, PhD; Dowd, Christopher F. MD; Higashida, Randall T. MD; Lawton, Michael T. MD; Duckwiler, Gary R. MD; Gress, Daryl.
Validation of Blood Flow Simulations in Intracranial Aneurysms Yue Yu Brown University Final-Project Presentation (Registration)‏
Noninvasive Measurement of Intracranial Pressure by MRI (MR-ICP) Overview Noam Alperin, PhD Physiologic Imaging and Modeling Lab Department of Radiology.
© 2011 Autodesk Freely licensed for use by educational institutions. Reuse and changes require a note indicating that content has been modified from the.
AIAA SciTech 2015 Objective The objective of the present study is to model the turbulent air flow around a horizontal axis wind turbine using a modified.
Dr. Daniel Riahi, Dr. Ranadhir Roy, Samuel Cavazos University of Texas-Pan American 34 th Annual Texas Differential Equations Conference Modeling and computation.
1 Dept. of Mechanical Engineering, University of Washington 2 Dept. of Neurosurgery, University of Washington 3 Dept. of Aeronautics, Imperial College.
Nelson Applied Research, Inc – N. 88 th St. Seattle, WA USA aol.com An Electrochemical Etching System for Producing.
1 Predicting and Understanding the Breakdown of Linear Flow Models P. Stuart, I. Hunter, R. Chevallaz-Perrier, G. Habenicht 19 March 2009.
Contrast Agent Transport Simulation using 4D PC-MRI Derived Flow Fields Ali Bakhshinejad, Roshan M. D'Souza, Loic Boussel, Vitaliy L. Rayz
Unsteady hemodynamic simulation of cerebral aneurysms А.А.Cherevko, А.P.Chupakhin, А.А.Yanchenko ( IGiL SB RAS, NSU)
A particle-gridless hybrid methods for incompressible flows
1 Webcam Mouse Using Face and Eye Tracking in Various Illumination Environments Yuan-Pin Lin et al. Proceedings of the 2005 IEEE Y.S. Lee.
Cerebral Haemodynamics and Auto-Regulatory Models of the Circle of Willis K T Moorhead, C V Doran, J G Chase, and T David University of Canterbury Dept.
Multi-scale modeling of the carotid artery
Copyright © 2010 Siemens Medical Solutions USA, Inc. All rights reserved. Hierarchical Segmentation and Identification of Thoracic Vertebra Using Learning-based.
EKF-based Paramater Estimation for a Lumped, Single Plate Heat Exchanger Andy Gewitz Mentor: Marwan Al-Haik Summer, 2005.
Lumped Parameter and Feedback Control Models of the Auto-Regulatory Response in the Circle of Willis World Congress on Medical Physics and Biomedical Engineering.
Constructing Hexahedral Meshes of Abdominal Aortic Aneurysms for Use in Finite Element Analysis Rowena Ong Vanderbilt University Mentor: Kara Kruse Computational.
METHODS CT scans were segmented and triangular surface meshes generated using Amira. Antiga and Steinman’s method (2004) for automatically extracting parameterized.
TUH EEG Corpus Data Analysis 38,437 files from the Corpus were analyzed. 3,738 of these EEGs do not contain the proper channel assignments specified in.
© Copyright ASD GmbH 2006 ASD ASD Advanced Simulation & Design GmbH Virtual product development in medical technology and engineering
CFX-10 Introduction Lecture 1.
MURI Annual Review, Vanderbilt, Sep 8 th, 2009 Heterogeneous Sensor Webs for Automated Target Recognition and Tracking in Urban Terrain (W911NF )
An Extended-State Observer based system of Brushless DC Motor using fuzzy logic Cross Strait Quad-Regional Radio Science and Wireless Technology.
Flowing Matter – COST Action MP1305, , Sofia NUMERICAL ANALYSIS OF THE STENOSIS EFFECTS ON THE BLOOD FLOW IN THE COMMON CAROTID ARTERY BIFURCATION.
1 Mathematical modeling of blood flow in translational medicine (1) Moscow Institute of Physics and Technology (2) Institute of Numerical Mathematics Workgroup.
COMPUTER SIMULATION OF BLOOD FLOW WITH COMPLIANT WALLS  ITC Software All rights reserved.
A Non-iterative Hyperbolic, First-order Conservation Law Approach to Divergence-free Solutions to Maxwell’s Equations Richard J. Thompson 1 and Trevor.
Modeling and Visualization of Combustion Using Fluid Simulator and Particle Systems Ing. Marek Gayer (supervised by prof. Pavel Slavík) Computer Graphics.
 ARTreat Veljko Milutinovi ć Zoran Babovi ć Nenad Korolija Goran Rako č evi ć
Laboratory for Product and Process Design Computer Assisted Design of Transport Processes in the Human Brain Laboratory for Product and Process Design,
Patient-specific Cardiovascular Modeling System using Immersed Boundary Technique Wee-Beng Tay a, Yu-Heng Tseng a, Liang-Yu Lin b, Wen-Yih Tseng c a High.
Venous Hypertension and Intracranial Aneurysm Rupture Fong Y Tsai,* Andrew Yen*, Wan-You Guo**Chin C Wu** *UC Irvine Medical Center, Orange,Ca ** Taipei.
The financial support of the European Commission is gratefully acknowledged. Material in this presentation reflects only the author’s views and the Commission.
Detection of nerves in Ultrasound Images using edge detection techniques NIRANJAN TALLAPALLY.
A NEW ALGORITHM FOR THE VISUAL TRACKING OF SURGICAL INSTRUMENT IN ROBOT-ASSISTED LAPAROSCOPIC SURGERY 1 Interdisciplinary Program for Bioengineering, Graduate.
Date of download: 6/9/2016 Copyright © ASME. All rights reserved. From: Cerebral Blood Flow in a Healthy Circle of Willis and Two Intracranial Aneurysms:
Understanding your FLOW-3D simulations better with EnSight June 2012.
Date of download: 7/8/2016 Copyright © ASME. All rights reserved. From: Effect of Inlet Velocity Profiles on Patient-Specific Computational Fluid Dynamics.
Combined Use of Color Duplex Ultrasonography and B-flow Imaging for Evaluation of Patients with Carotid Artery Stenosis AJNR Am J Neuroradiol 25: ,
ME 7980 Cardiovascular Biofluid Mechanics
Date of download: 10/9/2017 Copyright © ASME. All rights reserved.
Disturbed flow in a patient-specific arteriovenous fistula for hemodialysis: Multidirectional and reciprocating near-wall flow patterns  Bogdan Ene-Iordache,
Ultra-Low Contrast Volumes Reduces Contrast-Induced Nephropathy in Patients With Chronic Kidney Disease Undergoing Neurointerventional Procedures eP-150.
CFD Analysis of a Single-Stage Suborbital Rocket
Warren Chang, MD/MBA, Pablo Villablanca, MD, and Aichi Chien, PhD
Date of download: 10/21/2017 Copyright © ASME. All rights reserved.
Prepared BY: Helwan University Faculty Of Engineering
Date of download: 10/30/2017 Copyright © ASME. All rights reserved.
Alice Invernizzi Tutorial: matplotlib Alice Invernizzi
Arterial bifurcation with wide-mouthed saccular aneurysm.
Curved artery with aneurysm bleb.
Development of Cerebral Aneurysms. A Prediction Model
A, Left internal carotid artery (ICA) angiogram showing a left middle cerebral artery (MCA) bifurcation aneurysm and an additional distal MCA aneurysm.B.
Real-Time Cineangiography Visualization of Cerebral Aneurysm Rupture in an Awake Patient: Anatomic, Physiological, and Functional Correlates  Tasha L.
Computer Vision in Cell Biology
Patient 1 with a 4.4-mm residual aneurysm of the initial posterior inferior cerebellar artery segment close to its origin from the V4 segment of the left.
Parallel Feature Identification and Elimination from a CFD Dataset
A 29-year-old man with sudden neck pain followed by right-sided muscle weakness and difficulty in swallowing. A 29-year-old man with sudden neck pain followed.
Single-frame images from left common carotid rotational angiography before (A) and after (B) endovascular treatment demonstrate correction of the arterial.
62-year-old woman with incidentally discovered bilateral cavernous sinus aneurysms. 62-year-old woman with incidentally discovered bilateral cavernous.
MR examination and flow measurement procedures for a representative case (23-year-old woman).A, Lateral view of 3D time-of-flight MR angiography. MR examination.
Giant infrasupraclinoid aneurysm of the right ICA
Presentation transcript:

Jingfneg Jiang1, Kevin Sunderland1, Gouthami Chintalapani2, How might Flow Vortex Analysis Help in Characterization of ICA Aneurismal Flow: A Case Study Using Siemens CFD Prototype Software and VTK Jingfneg Jiang1, Kevin Sunderland1, Gouthami Chintalapani2, Kevin Royalty2 and Charles M Strother3 1Michigan Technological University 2Siemens Medical Solutions (USA), Inc. 3University of Wisconsin-Madison Who is the person from University of Erlangen? There is no corresponding number at one of the names? ASNR 2015

Disclosure J. Jiang and K. Sunderland are supported by a research contract from Siemens Medical Solution (USA), Inc. G. Chintalapani and K. Royalty are employed by Siemens Medical Solution (USA), Inc.

Introduction Hemodynamics plays a vital role in the origin, growth and rupture of aneurysms A growing body of literature indicates computational fluid dynamics (CFD) simulations could potentially provide insight into clinical management of cerebral aneurysms1,2

What is CFD? CFD produces results of mathematical models (i.e. Navier-Stokes equations) that researchers postulate capture the basic laws governing the physics of fluid flows.  Widely used and valued for industrial applications such as airplane design Image-based CFD simulations3 are under a rapid development “Patient-specific” vessel geometry is currently used Patient-specific physiological data could potentially further enhance the predictions

Clinical Utility of CFD? Significant anatomical and hemodynamic variations make interpretation of aneurismal dynamics difficulty Viewing time-resolved 3D hemodynamic (hundreds of) images may become a time-consuming and difficult task for physicians Jiang and Strother, ICS, 2009

Purpose Objective: To improve potential clinical utility of CFD, automated flow analysis may be useful Vortex core may provide relevant information related to flow physics The usefulness of vortex core analysis was demonstrated through a pilot study using 5 sets of ICA tandem (closely-space) aneurysms Study Design: 10 lateral ICA aneurysms in 5 patients; two closely spaced aneurysms in each patients CFD simulations of those six aneurysms were performed using Siemens CFD prototype software Automated vortex core analysis was performed using in-house software derived from Visualization ToolKit (VTK, Kitware Inc., NY)

Workflow

Step 1: CFD Simulations

CFD Simulation Conditions Typical waveforms (transient flow rates) were selected based on averaged Phase-contrast MR measurements6,7 For instance, averaged flow rate at the ICA was 280 ml/min Transient CFD simulations were performed for 2 cardiac cycles A voxel-based method8 (i.e. Siemens CFD prototype solver) was used to solve the Navier-Stokes equations Time steps were sufficiently fine and were adaptively chosen by the Siemens CFD solver 18 phases/steps of the second cardiac cycles were analyzed

Step2: Isolate Aneurismal Flow This algorithm was based on an published aneurysm extraction algorithm10 and implemented in the VTK

Vortex Analysis The well-known Lambda2 method by Jeong and Hussain9 was used to define the vortex core areas Two negative eigenvalues from a matrix derived from local velocity gradients A simple Marching-cube algorithm was used to segment out the vortex core volumes Implemented in the VMTK5 11

Temporal Flow Stability Flow stability was assessed by tracking changes of the vortex core(s) over time Calculate a temporally –averaged velocity field Calculate the time-averaged vortex core(s) from the time-average velocity field (purple colored vortex core below) Compare the (volume) overlap between the time-averaged vortex core(s) and the instantaneous vortex core(s) The (temporal) flow stability assessment is between 0 and 1 and there, is easy to interpret Low overlap means low (temporal) flow stability 12

Results The extracted vortex cores were visually consistent with velocity Vector plot Vortex Cores Velocity Plot Purple and green colors represent two vortex cores of the proximal and distal aneurysms, respectively

Results The calculate overlap value was consistent with visual assessments of temporal flow stability Overlap = 0.57 Overlap = 0.87

Mean Overlap of Vortex Cores Summary Results Mean Overlap of Vortex Cores Proximal Aneurysms 0.90 ± 0.06 Distal Aneurysms 0.78 ± 0.08 Temporal flow stability in proximal aneurysms were greater as compared to that in distal aneurysms (p = 0.03 [rank-sum test]) in data investigated Flow instability in the distal aneurysm might be induced by disturbed flow coming out from the proximal aneurysm

Study Limitations Vortex analysis results are yet to be verified with imaging measurements (e.g. Phase-contrast MR angiography) Only 10 aneurysms were studied

Conclusion and Future Work Preliminary results demonstrate that vortex-core analysis can potentially provide relevant information to characterize aneurismal hemodynamics Assessment of temporal flow stability through vortex core analysis might be an independent variable Future work is to verify results and explore its use in a clinical setting

References [1] J. R. Cebral, F. Mut, M. Raschi, E. Scrivano, R. Ceratto, P. Lylyk, and C. M. Putman, "Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment," AJNR Am J Neuroradiol, vol. 32, pp. 27-33, Jan 2010. [2] J. Xiang, V. M. Tutino, K. V. Snyder, and H. Meng, "CFD: computational fluid dynamics or confounding factor dissemination? The role of hemodynamics in intracranial aneurysm rupture risk assessment," AJNR Am J Neuroradiol, vol. 35, pp. 1849-57, Oct 2014. [3]D. A. Steinman, J. S. Milner, C. J. Norley, S. P. Lownie, and D. W. Holdsworth, "Image-based computational simulation of flow dynamics in a giant intracranial aneurysm," AJNR Am J Neuroradiol, vol. 24, pp. 559-66, Apr 2003. [4] N. M. Kakalis, A. P. Mitsos, J. V. Byrne, and Y. Ventikos, "The haemodynamics of endovascular aneurysm treatment: a computational modelling approach for estimating the influence of multiple coil deployment," IEEE Trans Med Imaging, vol. 27, pp. 814-24, Jun 2008. [5] L. Antiga and D. A. Steinman, "Robust and objective decomposition and mapping of bifurcating vessels," IEEE Trans Med Imaging, vol. 23, pp. 704-13, Jun 2004. [6] M. D. Ford, N. Alperin, S. H. Lee, D. W. Holdsworth, and D. A. Steinman, "Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries," Physiol Meas, vol. 26, pp. 477-88, Aug 2005.

References [7] M. Zhao, S. Amin-Hanjani, S. Ruland, A. P. Curcio, L. Ostergren, and F. T. Charbel, "Regional cerebral blood flow using quantitative MR angiography," AJNR Am J Neuroradiol, vol. 28, pp. 1470-3, Sep 2007. [8] V. Mihalef, P. Sharma, A. Kamen, and T. Redel, “An immersed porous boundary method for computational fluid dynamics of blood flow in aneurysms with flow diverters,” in Proceedings of the ASME Summer Bioengineering Conference, 2012. [9] J. Jeong and E. Hussain, “On the identification of a vortex”, J. of Fluid Mechanics, vol. 285, pp. 69-95, 1995. [10] J. Jiang and C. M. Strother, "Interactive decomposition and mapping of saccular cerebral aneurysms using harmonic functions: its first application with "patient-specific" computational fluid dynamics (CFD) simulations," IEEE Trans Med Imaging, vol. 32, pp. 153-64, Feb 2013.