Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation.

Slides:



Advertisements
Similar presentations
Harvard Medical School Massachusetts General Hospital.
Advertisements

Advanced GAmma Tracking Array
Faiza Bourhaleb Dipartimento di fisica sperimentale
LCSC - 01 Monte Carlo Simulation of Radiation Transport, for Stereotactic Radio Surgery Per Kjäll Elekta Instrument AB
Energy deposition and neutron background studies for a low energy proton therapy facility Roxana Rata*, Roger Barlow* * International Institute for Accelerator.
Alexander Klyachko, IU Cyclotron, PTCOG51, Seoul, South Korea, May 17-19, 2012 A.V. Klyachko 1, D.F. Nichiporov 1, L. Coutinho 2, C.-W. Cheng 2, 3, M.
D.G.Lewis Department of Medical Physics Velindre Cancer Centre Whitchurch, Cardiff RT-GRID: Grid Computing for Radiotherapy.
Algorithms used in heterogeneous dose calculations show systematic error as measured with the Radiological Physics Center’s anthropomorphic thorax phantom.
Dose Calculations A qualitative overview of Empirical Models and Algorithms Hanne Kooy.
MONTE-CARLO TECHNIQUES APPLIED TO PROTON DOSIMETRY AND RADIATION SAFETY F. Guillaume, G. Rucka, J. Hérault, N. Iborra, P. Chauvel 1 XXXV European Cyclotron.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Kirov A S, MSKCC Overview of Geant4 Use and Issues in Imaging: Emission Tomography (PET and SPECT) Assen S. Kirov Department of Medical Physics Memorial.
Interactions of charged particles with the patient I.The depth-dose distribution - How the Bragg Peak comes about - (Thomas Bortfeld) II.The lateral dose.
J. Tinslay 1, B. Faddegon 2, J. Perl 1 and M. Asai 1 (1) Stanford Linear Accelerator Center, Menlo Park, CA, (2) UC San Francisco, San Francisco, CA Verification.
G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti.
Tissue inhomogeneities in Monte Carlo treatment planning for proton therapy L. Beaulieu 1, M. Bazalova 2,3, C. Furstoss 4, F. Verhaegen 2,5 (1) Centre.
Part 1 Introduction to Radiotherapy and External Beam Radiation Deepak Khuntia, MD Vice President, Medical Affairs Varian Medical Systems.
Introduction Modern radiation therapies such as intensity-modulated radiation therapy (IMRT) and volume modulated arc therapy (VMAT) demand from dose calculation.
Theoretical calculations and simulations of interaction of X-rays with high-Z nanomoities for use in cancer radiotherapy Sara N. Lim, Anil K. Pradhan,
Results The measured-to-predicted dose ratio criteria used by the RPC to credential institutions is , however for this work, a criteria of
TWO FIELD BREAST PLAN VS. OPTIMIZED CONFORMAL BREAST PLAN: COMPARISON OF PLAN PARAMETERS Authors: Borko Basarić, Ozren Čudić, Milan Teodorović, Borislava.
Measurement of Dose to Critical Structures Surrounding the Prostate from Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional Conformal Radiation.
Научно-практический центр протонной лучевой терапии и радиохирургии (Москва-Дубна) A SYSTEM FOR MEASUREMENT OF A THERAPEUTIC PROTON BEAM DOSE DISTRIBUTION.
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
SOI detector Geant4-based studies to characterise the tissue-equivalence of SOI and diamond microdosimeteric detectors, under development at CMRP S. Dowdell,
Preliminarily results of Monte Carlo study of neutron beam production at iThemba LABS University of the western cape and iThemba LABS Energy Postgraduate.
G. Bartesaghi, 11° ICATPP, Como, 5-9 October 2009 MONTE CARLO SIMULATIONS ON NEUTRON TRANSPORT AND ABSORBED DOSE IN TISSUE-EQUIVALENT PHANTOMS EXPOSED.
Surface dose prediction and verification for IMRT plans using line dose profiles † Ronald E. Berg, † Michael S. Gossman and ‡ Stephen J. Klash † Erlanger.
Response of the sensors to different doses from tests in Israel Radiotherapy is used as a treatment in around 50% of cancer cases in the UK. Predominantly,
Ye, Sung-Joon, Ph.D. Ove, Roger, M.D., Ph.D.; Shen, Sui, Ph.D.
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
Wolfgang Enghardt Technische Universität Dresden, Germany OncoRay – Center for Radiation Research in Oncology and Forschungszentrum Dresden-Rossendorf,
1 Radiotherapy, hadrontherapy and treatment planning systems. Faiza Bourhaleb INFN-Torino University Med 1er-Morocco  Radiotherapy  Optimization techniques.
TPS & Simulations within PARTNER D. Bertrand, D. Prieels Valencia, SPAIN 19 JUNE 2009.
Chapter 5 Interactions of Ionizing Radiation. Ionization The process by which a neutral atom acquires a positive or a negative charge Directly ionizing.
Improvement of the Monte Carlo Simulation Efficiency of a Proton Therapy Treatment Head Based on Proton Tracking Analysis and Geometry Simplifications.
Comparison of MC and TP Dosimetry Simulations for Cancer Treatment Raymond Mumme May 12, 2014 Supervisor: Thiago Lima (PhD student) Head Supervisor: Dr.
ESTRO, Geneva 2003 The importance of nuclear interactions for dose calculations in proton therapy M.Soukup 1, M.Fippel 2, F. Nuesslin 2 1 Department of.
Karolina Kokurewicz Supervisors: Dino Jaroszynski, Giuseppe Schettino
Interaction of x-ray photons (and gamma ray photons) with matter.
Radiation Therapy Trials - Quality Assurance:  patient safety  adherence to protocol constraints  uniformity of patient treatments  efficient review.
Experimental Cave at Trento CPT: status update Francesco Tommasino RDH/IRPT Meeting – Roma, 1 Feb 2016.
Thickness of CZT detector 110 MeV140 MeV DETECTOR A (1 mm CZT + 5 mm CZT) DETECTOR B (1 mm CZT + 10 mm CZT) DETECTOR C (1 mm CZT + 15 mm CZT) A. Generation.
Dae-Hyun Kim Dept. of Biomedical Engineering The Catholic University of Korea Department of Biomedical Engineering Research Institute.
한양대학교 원자력공학과 김 찬 형 제44회 춘계의학물리학회 & Geant4 Workshop (충무, 마리나 리조트, ) Monte Carlo 원리 및 응용.
MCS overview in radiation therapy
Development of elements of 3D planning program for radiotherapy Graphical editor options  automated enclose of contour  correction of intersections 
E. Mezzenga 1, E. Cagni 1, A. Botti 1, M. Orlandi 1, W.D. Renner 2, M. Iori 1 1. Medical Physics Unit, ASMN-IRCCS of Reggio Emilia, Italy 2. MathResolution.
12 C fragmentation measurements for hadrontherapy applications Introduction Status French program Japanese-French collaboration.
Achim Stahl RWTH Aachen Hadron Therapy, Jülich Oct, Workshop Nuclear Models for Use in Hadron Therapy October 8./ Achim Stahl – RWTH Aachen.
Characterization of proton-activated implantable markers for proton range verification using PET J. Cho1, G. Ibbott1, M. Kerr1, R. A. Amos2, F. Stingo1,
J Cho, G Ibbott, M Kerr, R Amos, and O Mawlawi
Methods & Materials (continued)
J Cho, G Ibbott, M Gillin, C Gonzalez-Lepera, U Titt and O Mawlawi
Proton beam range verification using proton activated fiducials and off-site PET AAPM Best in Physics, Indianapolis, August 7, 2013 Cho J1, Ibbott G1,
EURADOS Working Group 9: Radiation Dosimetry in Radiotherapy
Proton range verification with PET: 68Zn, Cu and polycarbonate activation SNMMI Young Investigator Symposium, Vancouver, June 9, 2013 Cho J1, Ibbott.
Press release Release of ISOgray Proton Treatment Planning System
Very High Energy Electron for Radiotherapy Studies
International Workshop on radiosensitization
Development and characterization of the Detectorized Phantom for research in the field of spatial fractionated radiation therapy. D. Ramazanov, V. Pugatch,
M. D. Anderson Cancer Center Houston, TX
AAPM Annual Meeting, Anaheim, California July 13, 2015
Reducing Treatment Time and MUs by using Dynamic Conformal Arc Therapy for SBRT Breath-Hold Patients Timothy Miller, Sebastian Nunez Albermann, Besil Raju,
PET-utilized proton range verification using 13N signals
Feasibility of using O-18 for PET proton range verification
Function and Structure in
Geant4 at IST Applications in Brachytherapy
Nanoparticles for enhancing the effectiveness of proton therapy
Presentation transcript:

Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation Physics U.T. M.D. Anderson Cancer Center Houston TX, USA

Uses of Monte Carlo Clinical Uses in Radiation OncologyClinical Uses in Radiation Oncology - X-ray radiotherapy - Proton beam radiotherapy Research ActivitiesResearch Activities - Proton radiotherapy Current “challenges” for Geant4Current “challenges” for Geant4

Clinical Workflow of Radiotherapy CT images imported to Treatment Planning System (TPS) All parameters for dose delivery determined by TPS All parameters sent to proton delivery system for patient treatment.

Applications of Monte Carlo in Radiotherapy Treatment Planning System Monte Carlo X-Ray Therapy

Applications of Monte Carlo in Proton Therapy Use Monte Carlo to model treatment delivery equipment and calculate dose delivery (protons + secondary particles) Clinical Magnetic Scanning Delivery System Geant4 model Proton beam

Applications of Monte Carlo in Radiotherapy Simple Calculations of Dose in water Clinical calculations of dose in patient

Use Monte Carlo (Geant4 and MCNPX) to verify proton dose distribution calculated using TPSUse Monte Carlo (Geant4 and MCNPX) to verify proton dose distribution calculated using TPS Clinical Uses: Proton therapy TPS Monte Carlo

Use Monte Carlo (Geant4 and MCNPX) to verify proton dose distribution calculated using TPSUse Monte Carlo (Geant4 and MCNPX) to verify proton dose distribution calculated using TPS Clinical Uses: Proton therapy TPS Monte Carlo

Use Monte Carlo (Geant4 and MCNPX) to verify proton dose distribution calculated using TPSUse Monte Carlo (Geant4 and MCNPX) to verify proton dose distribution calculated using TPS Clinical Uses: Proton therapy Dose difference = TPS – Monte Carlo

Clinical Uses: Proton Therapy Calculation of secondary neutron exposure for Pediatric treatmentsCalculation of secondary neutron exposure for Pediatric treatments Taddei PJ et al. Phys Med Biol. 54(8): (2009)

Clinical Uses: Proton therapy Calculation of secondary neutron exposure for Pediatric treatmentsCalculation of secondary neutron exposure for Pediatric treatments Proton Dose Secondary neutron exposure

Research applications at MDA Treatment System DesignTreatment System Design Development of verification methodsDevelopment of verification methods New techniques for beam deliveryNew techniques for beam delivery

Research: Treatment Nozzle Design Improvements to existing treatment nozzles

Research: Treatment Nozzle Design If initial beam size changes? If we Remove RMW? Proton Dose Neutron fluence

Research: New Imaging Techniques In-vivo Dose verification with Post treatment PET imaging (1) Measure post treatment PET activation (2) Monte Carlo calc of post treatment PET activation (3) Estimate in vivo Dose distribution Parodi K et al. (2007) Med. Phys. 2007a;34: Parodi K et al. (2007) Int. J. Radiat. Oncol. Biol. Phys

Research: New Imaging Techniques In-vivo Dose verification with Prompt Gamma ray Imaging Measure Prompt Gamma Ray Emission Measure Prompt Gamma Ray Emission - Inelastic scattering [A(p, p’  )A] - Inelastic scattering [A(p, p’  )A] - i.e. – “real-time” signal - i.e. – “real-time” signal - each element emits characteristic - each element emits characteristic gamma-rays with different energies gamma-rays with different energies - gamma rays only emitted where - gamma rays only emitted where dose is deposited dose is deposited (a) (b) (c) Hypothesis: By properly measuring prompt gamma ray emission, we can images dose deposited and of elemental concentration and composition of irradiated tissues.

Beam pipe Phantom (Lucite or bone eq. plastic) Lead shielding Ge detector Lucite Bone eq. plastic - Measurements (symbols) - Geant4 Monte Carlo calculations (lines) - tally energy dep. from Photo-electric, Compton, Pair Production in detector [Polf et al, Phys. Med. Biol., 54: in-press, (2009)] Research: New Imaging Techniques In-vivo Dose verification with Prompt Gamma ray Imaging

Proton Beam

Prompt gamma imaging studies: Compton Camera Design target stage 1 stage 2 stage 3 Design studies to optimize efficiency: - triple scatters/proton - Compton scattering - detector material - detector shape Research: New Imaging Techniques

Research: New Treatment Techniques Feasibility studies of in-vivo magnetic steering Steering magnets Proton beam Magnetic field patient

patient Research: New Treatment Techniques Feasibility studies of in-vivo magnetic steering

Challenges and Limitations of Monte Carlo in Radiation Oncology Clinical Issues - Calculations in patient CT data Research issues - Disagreement with measured data - modeling of nuclear processes

Challenges and Limitations: Clinical Issues Clinical TPS: - calculate patient dose < 1 min - uses Analytical calculation algorithms algorithms -MC calcs too slow in CT data - greater than 5 hrs to calculate a full patient treatment plan!! a full patient treatment plan!! Why not Monte Carlo?

Challenges and Limitations: Clinical Issues Magnetic Beam Scanning: Dose calculation accuracy Monte Carlo

A proton pencil beam (spot)…... A few pencil beams together…. Some more… A full set, with a homogenous dose conformed distally and proximally Pedroni, PSI Challenges and Limitations: Clinical Issues Magnetic Beam Scanning: Dose calculation accuracy

Challenges and Limitations: Clinical Issues Monte Carlo 1 spot: Difference < 0.1 percent 10,000 spots: Difference > 5 percent

Challenges and Limitations: Clinical Issues Prompt gamma ray emission spectra

Nuclear Doppler Broadening Of the 4.44 Mev 12 C peak. - Excellent modeling of Doppler Broadening for low energy x-rays - However, no modeling for Nuclear Broadening Nuclear Broadening Challenges and Limitations: Clinical Issues

Conclusions on Monte Carl in Proton Therapy Geant4 is integral part in Clinical activitiesGeant4 is integral part in Clinical activities - treatment planning and verification Integral in research activitiesIntegral in research activities - equipment design - new treatment techniques Still some challengesStill some challenges - calculations in CT datasets - proton-nuclear interaction models?

Thank You! Questions?