Gamma-ray efficiency of a HPGe detector as a function of energy and geometry of energy and geometry Mohsen B. Challan Physics Department, Faculty of Education.

Slides:



Advertisements
Similar presentations
Instruments for Radiation Detection and Measurement Lab # 4.
Advertisements

NUCP 2371 Radiation Measurements II
Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Advanced GAmma Tracking Array
GEANT4 Simulations of TIGRESS
Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
Detector systems 1) Anti-Compton spectrometers 2) Pair spectrometers 3) Crystal spheres, walls, complex set-ups of semiconductor and scintillation detectors.
Cooling water for solar cold store using water-hyacinth. *Nagwa Ibrahim Physics department Majmaah University Zulfi College of education International.
Experimental Determination of Neutron Cross Sections of Yttrium by Activation Method by Barbara Geier Supervisors: Assoc. Prof Dr. Wolfgang Sprengel RNDr.
Evaluation the relative emission probabilities for 56 Co and 66 Ga Yu Weixiang Lu Hanlin Huang Xiaolong China Nuclear Data Center China Institute of Atomic.
GAMMA RAY SPECTROSCOPY
Radioactivity – inverse square law, absorption, and rates presentation for Apr. 30, 2008 by Dr. Brian Davies, WIU Physics Dept.
Anthony Sweeney Position Sensitive Detectors 9 Aberystwyth 2011.
Radiation Sensors Zachariadou K. | TEI of Piraeus.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Gamma Spectroscopy HPT TVAN Technical Training
X-Ray Fluorescence Analysis by Gergana Hristozova Project supervisor: s. eng. M. Gustova FLNR.
Instruments for Radiation Detection and Measurement Lab # 3 (1)
Gamma ray spectrum, its acquiring and analysis
Ch. 5 - Basic Definitions Specific intensity/mean intensity Flux
Characterization of CF 4 primary scintillation Andrey Morozov.
Measurements of cross-sections of neutron threshold reactions and their usage in high energy neutron measurements Ondřej Svoboda Nuclear Physics Institute,
Data processing in the Activation technique experiment. Making stacked or sandwiched in the repeated order of Al-Cu-Mo. Irradiation of the samples Using.
Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh). 1 Spectrum if all energy is captured in detector. Allows identification.
A Comparison of a Mean Field Theoretic Approach to Ferromagnetism with Experimental Results Patrick Yarbrough- Department of Physics and Engineering The.
Decay Data in View of Complex Applications Octavian Sima Physics Department, University of Bucharest Decay Data Evaluation Project Workshop May 12 – 14,
1 Lecture 5 Overview on the Analytical Procedures (  ) Lecture 5 Overview on the Analytical Procedures (  ) Moncef Benmansour Moncef Benmansour CNESTEN,

Accurate gamma-ray spectrometry of environmental samples: a challenge O. Sima - Bucharest University D. Arnold - PTB Braunschweig C. Dovlete - ERL Bucharest.
GERMANIUM GAMMA -RAY DETECTORS BY BAYAN YOUSEF JARADAT Phys.641 Nuclear Physics 1 First Semester 2010/2011 PROF. NIDAL ERSHAIDAT.
Chapter 32 Radiochemical Methods. Introduction… Radiochemical methods tend to be labor intensive and generate liquid waste due to the chemical separations.
DDEP 2012 | C. Bisch – Study of beta shape spectra 1 Study of the shape of  spectra Development of a Si spectrometer for measurement of  spectra 
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
Studies of neutron cross-sections by activation method in Nuclear Physics Institute Řež and in The Svedberg Laboratory Uppsala and experimental determination.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
Stopped Muon/Pion Measurements Jim Miller, BU May 2012 UW Test Beam Meeting.
Digital analysis of scintillator pulses generated by high-energy neutrons. Jan Novák, Mitja Majerle, Pavel Bém, Z. Matěj 1, František Cvachovec 2, 1 Faculty.
Octavian Sima Physics Department Bucharest University
Duncan Weathers Department of Physics University of North Texas.
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 Principles of Spectrometry.
Lawrence Livermore National Laboratory Nicholas Scielzo Lawrence Fellow Physics Division, Physical Sciences LLNL-PRES Lawrence Livermore National.
Development of X-ray Spectrometry for Nuclear Decay Data Applications at IFIN-HH Aurelian Luca Horia Hulubei National Institute of Physics and Nuclear.
Cross-sections of Neutron Threshold Reactions Studied by Activation Method Nuclear Physics Institute, Academy of Sciences of Czech Republic Department.
Production & Measurement of Thermal Neutron at RCNP Chhom Sakborey Nguyen Thi Duyen An Tran Hoai Nam Li Chunjuan Wang Mian.
DEVELOPMENT OF BETA SPECTROMETRY USING CRYOGENIC DETECTORS M. Loidl, C. Le-Bret, M. Rodrigues, X. Mougeot CEA Saclay – LIST / LNE, Laboratoire National.
Stellenbosch University
Neutron production study with the thick lead target and uranium blanket irradiated by 1.5 GeV protons Filip Křížek, ÚJF AV ČR.
Experiment TGV II Multi-detector HPGe telescopic spectrometer for the study of double beta processes of 106 Cd and 48 Ca For TGV collaboration: JINR Dubna,
Determination of activity of 51 Cr source on gamma radiation measurements V.V.Gorbachev, V.N.Gavrin, T.V.Ibragimova, A.V.Kalikhov, Yu.M.Malyshkin,A.A.Shikhin.
Development of a Segmented Planar Germanium Imaging Detector
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 In the figure: Photoelectric suppressed. Single Compton (effect of crystal dimensions).
Session II.3.5 Part II Quantities and Measurements
Why Accelerator Mass spectrometry (AMS) The determination of the concentration of a given radionuclide in a sample can be done in 2 ways: a) measure the.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Radiopharmaceutical Production Radionuclidic identity STOP.
Steven Moon, A.J. Boston, H. Boston, J. Cresswell, L. Harkness, D. Judson, P.J. Nolan PSD9, Aberystwyth, Wales th September 2011 Compton imaging.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
ArgonneResult_ ppt1 Comparison of data and simulation of Argonne Beam Test July 10, 2004 Tsunefumi Mizuno
Equalization of Medipix2 imaging detector energy thresholds using measurement of polychromatic X-ray beam attenuation Josef Uher a,b, Jan Jakubek c a CSIRO.
ESS Detector Group Seminar Edoardo Rossi 14th August 2015
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
Calculation of efficiency for a high-resolution gamma-ray spectrometer used for environmental radioactivity measurements Ileana Radulescu, Marian Romeo.
Monte Carlo methods in spallation experiments Defense of the phD thesis Mitja Majerle “Phasotron” and “Energy Plus Transmutation” setups (schematic drawings)
Investigation of the proton-induced reactions on natural molybdenum.
Full characterization of an old HPGe detector (GEROS)
M.I. Abbas - Alexandria University - EGYPT.
The experiment on JINR Dubna Nuclotron
p0 life time analysis: general method, updates and preliminary result
O. Svoboda, A. Krása, A. Kugler, M. Majerle, J. Vrzalová, V. Wagner
Radioactivity – inverse square law, absorption, and rates
Presentation transcript:

Gamma-ray efficiency of a HPGe detector as a function of energy and geometry of energy and geometry Mohsen B. Challan Physics Department, Faculty of Education in Zulfi, Majmaah University, P. O. Box. 66, Al-Zulfi 11932, Kingdom of Saudi Arabia. Abstract The concept of a double point detector model (DPDM) approach is developed as a procedure to find the full energy peak efficiency of the coaxial 120 cm3 closed HPGe detectors. Usually in the experimental work that involves using gamma-ray spectrometry the full energy peak efficiency (FEPE) function must represents adequately the HPGe detector response. In the current work the gamma-ray energy in the range from 59.5 to keV and gamma-ray intensity changes by changing source to detector distance from 10 to 800 mm. The detector was characterized using a number of point–like standard sources. The calculated efficiencies obtained by (DPDM) are in good agreement with experimental data. DOUBLE POINTS MODEL APPROACH In the present work a procedure is suggested to solve the above mentioned difficulties. In (3) a point-detector approximation was first proposed, in this point-detector approximation, the detector is considered to act as a point located along the detector axis at an effective distance behind the external window several authors latter (4-7) used techniques to calculate efficiencies at different distances. In the double points approximation, the detector is considered to act as a point of a definite active volume, the standard source as a point of infinitesimal size as well, both are located along the detector axis at an effective distance separate them. Then, the solid angle subtended by detector will equal to unit Steradian (Sr), if the distance increase than the solid angle will be less than unity, if the distance decreased than the solid angle will be more than unity. We then multiply the intrinsic detector efficiency by a factor to complete the whole solid angle surrounding the point source. We could write down the absolute efficiency as: (1) and Substituting from eq. (1) (2) The function which adequately represents the efficiencies between keV and distances between mm has the form: (3) Results 1. J. M. Maia, J. M. F. Dos Santos and C. A. N. Conde, Applied Radiation and Isotopes 48 (10-12), (1997). 2. P. M. Grant, Nuclear Instruments and Methods 127 (3), (1975). 3. P. R. Bevington and D. K. Robinson, Data reduction and error analysis for the physical sciences. McGraw-Hill, Boston, (2010). 4. M. B. Challan, M. N. H. Comsan, and M. A. Abou-Zeid, Thin target yields and Empire-II predictions on accelerator production of Technetium-99m, Journal of Nuclear and Radiation Physics, 2(1), 1-13 (2007). 5. K. Debertin and R. G. Helmer, Gamma- and x-ray spectrometry with semiconductor detectors. North-Holland, Amsterdam; Oxford, (2001). 6. A. Sanchezreyes, M. Febrian, J. Baro and J. Tejada, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 28 (1), (1987). 7. M. A. Hammed, P. W. Gray, A. H. Naboulsi and T. C. Mac Mahon, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 334 (2–3), (1993). References 1. Experimental Set-up: The detector used in these measurements was ORTEC hyper pure Germanium Detector. The germanium crystal was nominally 55 mm in diameter and 60 mm long. It was mounted inside a protective aluminum end, with its axis vertical, on a liquid nitrogen Dewar, with an energy resolution of 2.0 keV for a -ray energy of keV. The source holder was made of cylindrical hard paper with seven slots to accommodate the point sources which are at the center of a polyethylene dish. The detector active volume was estimated to be (120 6) cm 3. The detector was biased to V using an ORTEC-459 power supply. Pulses from the pre-amplifier were amplified and shaped by Canberra 2021 spectroscopy Amplifier before being fed into a Trumf 8192 buffered analog-to-digital converter controlled by an IBM-Compatible computer. Methods and Materials The full energy peak efficiencies were calculated in the energy range from 59.5 to keV and in distance between 10 and 800 mm. A new theoretical function has been proposed which adequately represents the experimental points. The advantage of using a function of this type is that it is possible to determine the efficiency at point where experimental measurements do not exist. It is worthwhile mentioning that the coincidence summing effects must be taken into account while carrying out measurements at short distances from detector window, using radioisotopes emitting gamma-rays in cascades. Conclusions Introduction The quantitative γ-ray spectrometry at different geometries is a commonly encountered problem. Accurate relative intensity calibration of photon emitted is usually performed by counting a sample and standard sources in the same geometry. It is therefore important to have available method to correct measurement taken with HPGe detectors from the effects of geometry change, hearing in mind that HPGe detector efficiency curves are most often and conveniently determined using point-like standards. In general, one or two efficiency curves are obtained at different distances. This is usually done in order to minimize the detector’s dead time and to maximize the area under full energy peak, a higher uncertainty in the photo-peak area is found due to the spectral distortion. Hence, changing counting geometry is a mandatory for comparison between measurements, introduces a need for solid angle geometry corrections as well as for coincidence summing if applicable. Many authors commented of the importance of measurement geometries (1, 2). 2. The gamma-ray Sources For the point-like sources we used -ray reference standard sources from the Oak-Ridge, The Tennessee, U.S.A. These take the form of ion- exchange beads 2 mm in diameter held in clear plastics cases fitted with polyethylene windows 0.5 mm thick. The radionuclides used were 241 Am, 137 Cs, 54 Mn, 65 Zn, 60 Co and 109 Cd these span the energy range from keV. 3. Efficiency calculation Once the full energy peak area is obtained the intrinsic efficiency can be calculated by the following equation: (1) Where: is the intrinsic peak efficiency, is defined as the probability that a photo striking the detector will produce a pulse residing in the full energy peak of the spectrum. is the corrected net peak area in counts/s is the activity of the source at the time of standardization in (Bq), is the absolute -ray emission probability is the decay constant. (lamda) t is the elapsed time since standardization is the duration of the count (sec). Fig.1: Full Energy Peak Efficiency of the HPGe Detector vs Energy Fig. 2: Typical plots for determining using a coaxial close-ended HPGe detector. Fig.3: Shows the absolute full energy peak detection efficiency of the HPGe detector for point sources on axis as a function of γ–ray energy and separation, this functions fitted to the experimental points.