To Meet NPDES Retention and Hydromodification Management Requirements Tom Dalziel Program Manager, Contra Costa Clean Water Program Dan Cloak Dan Cloak.

Slides:



Advertisements
Similar presentations
Review & Update of the Stormwater C.3 Guidebook Dan Cloak, P.E. Principal Dan Cloak Environmental Consulting.
Advertisements

Hydrologic Analysis Dr. Bedient CEVE 101 Fall 2013.
Urban Low Impact Development English + Associates Owner Architect Construction EcoServices Storm-water Tank Contractor General Contractor T&T Construction.
Construction of Facilities Dan Cloak Environmental Consulting Construction Workshop, May 2, 2012.
Permeable Heavy Use Area for Livestock Farms Presentation for Kitsap County DCD, September 28 th, 2006, Lab Test Findings and Calculated Storm Water Performance.
Soils Well-designed systems capture sediment near the entrances Sediment loads vary by facility Regular visual checks are the key City of Portland Environmental.
Operation & Maintenance Requirements: Tips for Keeping Your Agency in Compliance Kristin Kerr, P.E., QSD EOA, Inc. New Development Workshop May 22, 2013.
Infiltration Trenches Dave Briglio, P.E. MACTEC Mike Novotney Center for Watershed Protection.
z = -50 cm, ψ = -100 cm, h = z + ψ = -50cm cm = -150 cm Which direction will water flow? 25 cm define z = 0 at soil surface h = z + ψ = cm.
What’s New in the Fifth Edition Dan Cloak Environmental Consulting May 23, 2011.
Simplified Sizing Tool for LID Practices in western Washington Alice Lancaster, PE Herrera Environmental Consultants.
LID Site Design and Drainage Dan Cloak Environmental Consulting May 23, 2011.
UW LID Workshop Bioretention Flow Control Modeling May 2008
INLAND EMPIRE ASCE & APWA LOW IMPACT DEVELOPMENT (LID) SEMINAR INLAND EMPIRE ASCE & APWA LOW IMPACT DEVELOPMENT (LID) SEMINAR LID FACILITY DESIGN Prepared.
Where are the regulations going? Dan Cloak Environmental Consulting May 23, 2011.
Low Impact Development for Stormwater Treatment and Hydrograph Modification Management in California Dan Cloak, Principal Dan Cloak Environmental Consulting.
Stormwater Management
OKLAHOMA STATE UNIVERSITY Biosystems and Agricultural Engineering Department Hydrology 101 OKLAHOMA STATE UNIVERSITY Biosystems and Agricultural Engineering.
Bioretention Design Getting the Details Right. Coordination of Plans Curb elevations, grade breaks, architectural plans consistent with delineation of.
Continuous Hydrologic Simulation of Johnson Creek Basin and Assuming Watershed Stationarity Rick Shimota, P.E. Hans Hadley, P.E., P.G. The Oregon Water.
Infiltration Infiltration is the process by which water penetrates from ground surface into the soil. Infiltration rate is governed by: rainfall rate hydraulic.
Hydrologic Theory One of the principal objectives in hydrology is to transform rainfall that has fallen over a watershed area into flows to be expected.
Bioretention soil test demonstration Carlton Thompson and Jeff Cowling.
SDHM Hydromodification Overview
Western Washington Hydrology Model Version 3
C.3 in MRP 2.0 What to Expect (as of March 17, 2015) Dan Cloak.
Stormwater Infrastructure for Water Quality Management Dr. Larry A. Roesner, P.E. CE 394K.2 Surface Water Hydrology University of Texas, Austin April 8,
For Stormwater Treatment and Flow Control Dan Cloak Environmental Consulting December 14, 2010 Contra Costa Clean Water Program.
Implementing MRP Provision C.3 Stormwater NPDES Compliance For New Developments.
6 th Edition CCCWP Management Committee February 15, 2012.
Inspecting Construction of Bioretention Facilities Carlton Thompson and Jeff Cowling.
Horsley Witten Group, Inc. Rhode Island Stormwater Design and Installation Standards Manual Public Workshop Design Elements for BMPs January 19, 2011.
Feasibility of Infiltration and Harvesting/Reuse Analysis and Documentation for Stormwater Control Plans.
Bioretention Dave Briglio, P.E. MACTEC Mike Novotney Center for Watershed Protection.
STEP 3: SITING AND SIZING STORM WATER CONTROLS Section 6.
Background and Overview Stormwater NPDES Compliance For New Developments.
Dan Cloak, P.E. 18 September 2007 to achieve water quality benefits in Contra Costa County Implementing Low Impact Development.
New Stormwater Regulations “C.3” Provisions in effect Feb. 15, 2005.
Stormwater Treatment and Flow Control Dan Cloak, P.E. Presentation to the San Diego Region Co-permittees Hydromodification Workgroup December 6, 2006 Contra.
Why are we here today? To discuss the challenges we face in meeting NPDES Phase II minimum requirements for stormwater control. The NPDES program requires.
Stormwater Treatment and Flow Control Dan Cloak Presentation to the Citizens Advisory Committee November 13, 2006 Options for implementing new Phase II.
Stormwater Treatment and Flow-Control Requirements in Phase I and Phase II Municipal NPDES Permits Dan Cloak, Principal Dan Cloak Environmental Consulting.
Hydrograph Modification Management in Contra Costa County Dan Cloak, P.E. Dan Cloak Environmental Consulting.
Regulatory Refresher What Construction Site Inspectors Need to Know about the MRP Kristin Kerr, P.E., QSD EOA, Inc. Construction Inspection Workshop April.
Stormwater and C.3 Overview Tom Dalziel, Assistant Manager Contra Costa Clean Water Program.
Low Impact Development for Compliance with NPDES Treatment and Hydrograph Modification Management Requirements in Contra Costa County Tom Dalziel, Assistant.
For Bioretention Facilities Dan Cloak Environmental Consulting May 23, 2011.
Countywide Model SUSMP July 17, Topics SUSMP Timeline Goals Approach to Compliance NPDES Permit Requirements NPDES Permit Requirements Model SUSMP.
PSGB Ecosystem Conference The Effectiveness of LIDs in Reducing Stormwater Runoff February 9, 2009 Doug Beyerlein, P.E. Clear Creek Solutions, Inc.
Low Impact Development [presenters name] [presentation date] Integrated Management Practices Controlling Stormwater Quality and Quantity using.
Western Washington Hydrology Model 2005 AWRA Annual Conference Doug Beyerlein, P.E. Joe Brascher Shanon White Clear Creek Solutions, Inc.
STORMWATER MANAGEMENT
Sizing Stormwater Control Facilities to Address Stream-Bank Erosion Control Anthony M. Dubin, PE Brown and Caldwell Anthony M. Dubin,
Operation & Maintenance of Permanent Stormwater Controls Overview of Inspection Requirements Laura Prickett, AICP, CPESC EOA, Inc. Construction Inspection.
Surface Water Surface runoff - Precipitation or snowmelt which moves across the land surface ultimately channelizing into streams or rivers or discharging.
Clear Creek Solutions, Inc. LID Hydrology and Hydraulics Doug Beyerlein, P.E. Clear Creek Solutions, Inc.
ASCE LID Conference LID Analysis Considerations in Western Washington November 17, 2008 Doug Beyerlein, P.E. Clear Creek Solutions, Inc.
 Holds water in the landscape so it infiltrates (drain) into the ground.
City of Clarksville Storm Water Management Manual Revisions 2014.
SUBSURFACE INFILTRATION VAULTS: PUTTIN’ WATER IN IT’S PLACE OBJECTIVES Water Flow In Vaults STRENGTH ANALYSIS SEDIMENTATION AND INFILTRATION SLOPE FUNCTION.
Construction of On-Site Stormwater Treatment and Flow Control Facilities Dan Cloak, P.E. Principal Dan Cloak Environmental Consulting.
Modeling Low Impact Development Techniques and Detention Basins in SWMM CEE 6/5460 David Rosenberg.
SPU Modeling & Monitoring
Storm Water Storage and Treatment
Sacramento County Stormwater Quality Program
Northern California LID Hydrology and Hydraulics
Preciptation.
Chapter Four RUNOFF When a storm occurs, a portion of rainfall infiltrates into the ground and some portion may evaporate. The rest flows as a thin sheet.
What we have developed is…
Sacramento County Stormwater Quality Program
Presentation transcript:

To Meet NPDES Retention and Hydromodification Management Requirements Tom Dalziel Program Manager, Contra Costa Clean Water Program Dan Cloak Dan Cloak Environmental Consulting CASQA Conference, September 27, 2011

 21 Copermittees  One million residents  Oldest city incorporated 1876; newest incorporated in 1999  Annual rainfall from 12" to 30"  Mostly clay soils

 Stormwater C.3 Guidebook published 2005  LID approach to treatment  Well received and widely implemented  Continuously improved under direction of municipal staff  Fifth Edition published 10/20/2010  Hydrograph Modification Management Plan (HMP) approved 2006  Uses LID to control flow peaks and durations  Based on computer-modeled performance of bioretention and other LID facilities  HMP requires monitoring 5 locations to validate model

 Bioretention:  What we don’t know  Why we need to know it  Model of Bioretention Performance  Rate and duration of underdrain discharge  Design of Our Experiment to Validate Model  Design and Construction of Bioretention Facilities and Monitoring Instrumentation  Office Building  Residential Townhouse Development

infiltration evapotranspiration biotreatment What proportion of runoff goes where?

One Acre inflow underdrain evapotranspiration infiltration

 A watershed model (HSPF) was adapted to characterize bioretention performance.  Stage-storage discharge relationships for each layer represented within FTABLEs in HSPF.  At each time step, moisture content of the bioretention soil media, matric head within soil pores, and hydraulic conductivity of the soil media are recalculated.  Watershed models are typically calibrated using stream gage data. This model is uncalibrated.

 Pan evaporation was used to calculate evapotranspiration.  Single, textbook values were used for hydraulic conductivity of underlying soils.  Lateral movement of moisture from the bioretention media and gravel layer into the surrounding soil was not accounted for.  The effects of head above the underlying soil surface were not accounted for.

Hour #Flow (cfs) Etc.

Hour #Flow (cfs)Hours exceeded Etc. This flow was exceeded during 2 hours/250,000 hours (0.0008%) This flow was exceeded during 7 hours/250,000 hours (0.0028%)

Facility DesignSoil Group Area A (ft 2 /ft 2 ) Volume V 1 (ft 3 /ft 2 ) Volume V 2 (ft 3 /ft 2 ) Rainfall Adjustment for Surface Area Rainfall Adjustment for Storage Volume Maximum Release Rate Bioretention Facility A No min.Eq. 4-6 No orifice B No min.Eq. 4-7 No orifice C Eq. 4-8 Eq D Eq. 4-9*Eq. 4-9Eq Flow- through Planter ANot permitted in “A” soils BNot permitted in “B” soils C Eq. 4-8 Eq D Eq. 4-9*Eq. 4-9Eq Dry Well A N/AEq. 4-6 No release B N/AEq. 4-7 No release CNot permitted in “C” soils DNot permitted in “D” soils Cistern + Bioretention A N/AEq. 4-13Eq. 4-6Eq B N/AEq. 4-14Eq. 4-7Eq C N/AEq. 4-15Eq. 4-8Eq D N/AEq. 4-16Eq. 4-9Eq Bioretention + Vault A0.04N/A0.096N/AEq. 4-6No release B0.04N/A0.220N/AEq. 4-7Eq C0.04N/A0.152N/AEq. 4-8Eq D0.04N/A0.064N/AEq. 4-9Eq. 4-11

 Collect on-site rain gage data.  Calculate hourly inflow for the real tributary area  Use the model to predict hourly ET, infiltration, and underdrain flow  Measure actual underdrain flow.

 Compare predicted to actual outflow rates (hour by hour).  Tweak the model inputs so that model output more accurately represents actual underdrain discharge (hour-by-hour and storm-by-storm).  Then, use those new model inputs to recalculate sizing factors for bioretention minimum area (A), surface storage volume (V 1 ) and subsurface storage volume (V 2 ).

We can then input 30+ years of rainfall data and use our validated/tweaked model to predict the percent infiltrated + evapotranspirated (annual average).

Within some of the facilities, we will also track saturation level.

Overflow elevation

Native soil, no compaction. Rip to loosen. Class 2 perm (Assume 40% porosity for calculation of V 2 ) Min. 12“ or as needed to achieve V 2 Min. 18“ Specified soil mix 3" max. mulch if specified in landscape plans Min. 6" or as needed to achieve V 1 Curb cut (or curb inlet if needed to ensure runoff capture) 4" min. dia. SDR 35 or equiv. sweep bend and cleanout min. 2" above overflow level 4 " min. dia. SDR 35 or equiv., perforations facing down Top of Gravel Layer TGL Bottom of Gravel Layer BGL Top of Soil Layer TSL Overflow structure 24" min x 36" min. concrete drop inlet or manhole with frame and atrium or beehive grate, ¼ “ openings Schedule 80 (no perforations) seal penetration with grout Male threaded pipe end with cap center- drilled to specified orifice dia. (Omit cap for treatment- only facilities.) 24" 6" To storm drain or approved discharge point Notes: No liner, no filter fabric, no landscape cloth. Maintain BGL. TGL, TSL throughout facility area at elevations to be specified in plan. Class 2 perm layer may extend below and underneath drop inlet. Preferred elevation of perforated pipe underdrain is near top of gravel layer. See Appendix B for soil mix specification, planting and irrigation guidance. See Chapter 4 for factors and equations used to calculate V 1, V 2, and orifice diameter. Install all plantings to maintain TSL at or below specified elevation Cobbles or splash block Adjacent pavement Moisture barrier if needed to protect pavement or structures Bioretention Facility Cross-section Not to Scale Large diameter closed perforated pipes or arches may augment storage to achieve V 2 Walls as needed to establish constant rim elevation around perimeter of facility

Hydro Services TV!LT Tipping Bucket  Required 12” clear from orifice to bottom of catch basin  Installed weir and pump system to prevent storm drain backups from flooding instrumentation

 Development projects completed summer  Instrumentation installed September  Data collection during and rainy seasons.  Analysis of initial data during  Report due to SF Bay Water Board April 1, 2014

 Jolan Longway, City of Pittsburg  Carlton Thompson, City of Walnut Creek  Scott McQuarrie and Mark Boucher, Contra Costa Flood Control District  or search for “Contra Costa Stormwater”