Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s Beghelli-Elplast has developed new luminaire Titania, which fully meet valid directives for the equipping of road tunnels. 1
Luminaire Titania has been developed and designed in accordance with the latest edition of RABT 2 Regulations for the equipment and operation of road tunnels This combined escape route and emergency fire light Titania helps to show vehicle passengers the fastest and safest way out of the tunnel in extreme cases. Approved by German Federal Ministry for Traffic, Building and Urban Affairs
According to the German Federal Ministry of Transport For all traffic tunnels that are longer than 400 m must be installed with emergency fire and escape route luminaire Titania 3
Combined escape route and emergency fire luminaires 20 m 1,2 m 4
Titania 1.Second independent power supply from distribution network 2.Independent source of electrical energy (generate by using genset – Engine-generator, a machine used to generate electricity ) and - UPS (Uninterruptible Power Supply Source, to allow time to bring an auxiliary power source on line). T he norm establishes that when a tunnel suffers from a failure of power supply, an emergency power supply system and an emergency lighting system must be at hand. Power supply Operating voltage: 230V 5 Options
Titania The body: Stainless steel Dustproof and waterproof protection type IP 65 protected against water jet cleaning Diffuser: 4 mm safety tempered glass Pictogram size: 300 x 300 mm according to RABT 5 years guarantee 6 Technical features:
Titania Special gasket for IP65 Terminal block 5x2,5mm 2 Higly polished reflector from AL Tube clamps for through wiring 7
Bevelled edges (to avoid injury of running people during accident) 474 mm 594 mm Thickness 60 mm Titania Dimensions according to RABT 8
Titania Weight 8,3 kg Special key for opening Safety and security 9
Titania LED identification lights: There is 6 LEDs Osram Golden Dragon Oval Plus inside of the housing Luminous intensity 75cd/m 2 (RABT) LED emergency fire lights: The internal lighting consists of 2 cool white 6300K high performance LEDs. For additional security, they are linked in such a way that should one LED ever fail, the others remain light. Primary electrical circuit -14,5W Secondary electrical circuit – 9W All LEDs are protected behind safety glass 10 Total – 23,5W
Titania Summary of technical data Energy consumption: 23,5W (14,5W+9W) Degree of protection: IP 65 Shock protection: IK09 (5 Joule) Standards and certificates Vibration test EN Impact resistance EN Change of temperature Class T2 (-25°C / +55°C) IEC Damp heat Class T1/T2/T3 (+40°C) EN Water ingress Class IP65 EN Dust ingress Class IP65 EN Corrosion test (Salt spray test) 11