Contact person: E. Swietlicki, A. Massling NMR – Nordic Aerosol Project 2004-2006 DMPS/SMPS Intercomparison Division of Nuclear Physics, Lund University,

Slides:



Advertisements
Similar presentations
The Care and Feeding of Burets
Advertisements

NANOSH Hunting for Nanoparticles A Year in the Life of an Aerosol Scientist I.L. Tuinman.
Do Now: Choose One 1) List the three major kinematic equations 2) Define displacement, velocity and acceleration using complete sentences.
Operating Nitrox Systems 11 Presented by Nuvair. Operating Nitrox Systems2 Membrane systems produce nitrox efficiently Compressed air flows through the.
Engineering Roles We will be forming groups of 3 students
Yu. I. BARANOV and W. J. LAFFERTY Optical Technology Division Optical Technology Division National Institute of Standards and Technology, Gaithersburg,
Optical Properties of Aerosol Particles Introduction Atmospheric aerosol particles play a significant role in determining Earth's climate, through their.
Stoichiometry Chapter 5. Stoichiometry Quantitative relationships between reactants and products The balanced chemical equation gives us the relationships.
when calibrating the sprayer
1. Aerosol Instrumentation – In Situ Measurement of Particle Size and Number Example of size distribution (Number size distribution with three log- normal.
Aerosol Optical Properties via Cavity Ring-Down Technology Virtual Impactor for Sub-micron Aerosol Particles A. A. Boľshakov, A. W. Strawa, A. G. Hallar.
Control and regulation of boiler operation Heat Engines & Boilers.
ENERGY CONVERSION ES 832a Eric Savory Lecture 11 – A small-scale power plant worked example Department of Mechanical.
Experimental Procedure Lab 406. Overview A gas generator is constructed to collect the CO 2 (g) evolved from a reaction. The masses of the sample in the.
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
ALGALTOXKIT F Test procedure. 1 PREPARATION OF ALGAL CULTURING MEDIUM - VOLUMETRIC FLASK (1 liter) - VIALS WITH NUTRIENT STOCK SOLUTIONS A (2 vials),
This tutorial is a PowerPoint ® file which includes recorded narration. Automatic slide sequencing is coupled to the sound track. For the most effective.
VOLATILITY MEASUREMENTS OFF LABORATORY GENERATED ORGANIC AEROSOLS WITH VOLATILITY TANDEM DIFFERENTIALLY MOBILITY ANALYZER. VTDMA K. Salo*, Å. M. Jonsson,
ACTIVE CONTROL OF A GAS FLOW RATE IN AN ALTERNATING GRADIENT DIFFUSION CHAMBER USING LABVIEW by Max Trueblood & David LeBlanc ME240 Semester Project MS&T,
1 May 6, 2009 C. Lu Continuously Monitoring the RPC Gas Mixture with a Gas Chromatograph C. Lu Princeton University.
Background New 3mm thick optical filter
Chamber background – brand new bag (first day of use)
Parallel aerosol sampling with SMPS and LPI in biomass combustion B. Stojkova, M. Hagström, J. B. C. Pettersson, Department of Chemistry, Physical Chemistry,
1 Motivation Particles are generally regarded as one of the most serious indoor air quality concerns Increasing concern about ultrafine particles Very.
Making Dilutions from Solutions
Concentration and Dilution of Solutions. HOW TO MAKE A SOLUTION “The Procedure” We’ll make a Kool-Aid Solution!!!
¾-1/2” Red. Union 3/8”OD ACSM Inlet Configuration 0.1 lpm to ACSM with PM 1 passing thru aerodynamic lens 2.9 lpm to external Pump* Sheath Flow 6 lpm dry.
DIFFERENTIAL MANOMETER
FUEL INJECTION SYSTEM OPERATION
Pump performance testing living with the lab © 2011 LWTL Faculty Team.
Preparing Solutions LG: I can use formulas for concentration to prepare standard solutions from a solid.
TSI Incorporated Seeding of Flows TSI LDV/PDPA Workshop & Training Presented by Joseph Shakal Ph.D.
Pre-Lab Talk Thompson Rivers University
Experimental Procedure. Overview The supernatant from a saturated calcium hydroxide solution is titrated with a standardized hydrochloric acid solution.
Polymer Nanofibers from Recycling of Waste Expanded Polystyrene Research at The University Of Akron C. Shin and G. G. Chase Polymer Nanofibers from Recycling.
 o (100 nm) Relative Humidity Carrier Gas Stream NaCl Mg/Na Dependence.
ADVANCE IN AUTOMOBILES HYDROGEN FUELLED ENGINES BY C.SUBRAMANIAN, 10MECH50, III-MECH, VCET,MADURAI.
New Measurements of Hygroscopicity- & Size-Resolved Particle Fluxes Brittany Phillips, K. Dawson, T. Royalty, R. Reed, M. D. Petters, and N. Meskhidze.
Exp. 18: Spectrophotometric Analysis: Concentration of a Solution Using Beer’s Law White light violet (400nm) – red (800nm) “visible spectrum” sample (light.
DALTON’S LAW OF PARTIAL PRESSURE
1 Latency and pedestal test Mikko Nykänen
1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1.
Lab Instructions. Materials and Equipment Distilled Water Zinc metal Filter Paper Plastic Wash Bottle Copper II sulfate Tap water Pencil (not a pen) Plastic.
INSTRUMENTATION DMPS – H-TDMA – CCN COUNTER –
Preparing Solutions.
Original CPC Box schematic
EMPIR Workshop – TP Environment Matthias Richter Birte Mull
CHARMEX VHTMA quick look Operational from: 5th July to 12th of July Selected sizes: 40 nm, 80 nm Oven temperature: 120 o C Problems Charging in DMA at.
Progress and hold-ups in CarboEurope intercomparison activities News on sausages, grapefruits, cucumbers Armin Jordan Max-Planck-Institute for Biogeochemistry.
Stratospheric Aerosol Size Distribution Retrievals Using SAGE III Mark Hervig GATS Inc. Terry Deshler University of Wyoming.
© 2009, TSI Incorporated PMP PNC Calibration Recent Experiences Hans-Georg Horn TSI GmbH, Particle Instruments PMP Meeting, London, 30 March 2009.
UT/LS H 2 O validation issues Important issues that remain unresolved:  Establishing the frequency and also temperature dependence of supersaturation.
Experiment: Solutions Preparation, Part 1 1CHE116.
Aerosol Working Group Location: Room 2.16, 2 nd Floor, Williamson Building, Oxford Road, Manchester 11:00 Coffee 11:30 – 13:00Instrument Updates: CCN/CPC/PSAPJamie.
Parameter's Approach to Relative Humidity Control August 25, 2011 by Clay Hile.
Air condition installation
Outline 7-1 Comparing Test Methods 7-2 Review of Filtration Mechanisms
AP Lab Day (Sept 20th) Get out your laptops and lab books!
Date of download: 11/4/2017 Copyright © ASME. All rights reserved.
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
Melting of ice particles:
ANSI/ASHRAE 52.2 A destructive test to measure minimum efficiency reporting value (MERV) Efficiency test aerosol is Potassium Chloride (KCl) particles,
Polymer Nanofibers from Recycling of Waste Expanded Polystyrene
Experiment 2. Inversion of Sucrose
Additional evaluations at AVL
Experiment 2. Inversion of Sucrose
Laura Lund University of Arizona Dr. William Conant
Inter-Laboratory Comparison Exercise CPC CALIBRATION
Particle Size and Size Distributions
Preparing Solutions by Dilution
Presentation transcript:

Contact person: E. Swietlicki, A. Massling NMR – Nordic Aerosol Project DMPS/SMPS Intercomparison Division of Nuclear Physics, Lund University, Lund,

General Information Within the NMR project, an intercomparison of all continuously operated Differential/Scanning Mobility Particle Sizers (DMPS/SMPS) will be done. The Lund University provides the equipment for a set up that can be applied to each system to generate defined particle number size distributions of monodisperse particles. The size and the number concentration of the generated particles should be determined with your DMPS/SMPS and results will be compared. Please do not move your system, you can easily provide our set up in your lab where the system is located. For the intercomparison it is crucial to make the set up as detailed as it is explained on the next slides.

Preparing the set-up Things you have to prepare: Dry, particle and oilfree, pressurized air at 3 hPa Deionized water A computer with a serial port Things we have prepared: A program to log the CPC 3022 A dilution chamber Two nebulizers (both for spheres) Two needle valves Two three way valves Two filters One CPC 3022 (Condensation Particle Counter) Three small flasks containing latex spheres (Dp = 101nm, 277nm, and 420nm)

Additional information It is recommended to do the following work before starting any measurements. 1. Be sure that your system is leaktide. 2. Be sure that your flows within the systems are calibrated nicely. 3. Be sure that the high voltage supply is calibrated. 4. Be sure that the relative humidity in the system is as low as possible (aerosol inlet RH before charger and sheath air RH).

Please provide the set up exactly how it is shown in the sketch on the next slide. The set up is thought to investigate the sizing of your DMPS/SMPS system. Please use dry, particle and oilfree, pressurized air for the set up. The following flowrates should be adjusted: Nebulizer: 2.0 lpm Dilution air: lpm CPC 3022: 2.0 lpm Please note: The dilution rate depends on the aerosol flowrate of your system since all other flows are defined. The dilution chamber must have slightly overpressure in comparison to atmosphere. Preparing the set up (sizing experiment)

DMPS/SMPS intercomparison set up Mixing Chamber DMA Micro-Neb Nebulizer CPC Reference 2.0 lpm Pressurized Air Supplied by Lund PSL monodisperse particles Bipolar Charger Drier Your system operated at defined flowrates One inlet open to atmosphere (additional inlets closed) Needle valve Three way valve Filter 2.0 – 4.0 lpm 2.0 lpm

The intercomparison will include two different experiments comparing size and number concentration of particles measured by your DMPS/SMPS. The first experiment will give information about the sizing of your system. Please be sure that you also log the data of the CPC. Experiment 1a (101nm spheres): Prepare a solution of four to eight droplets of 101nm latex spheres and 20ml of deionized water. Use the nebulizer to spray the particles. Measure the particle number size distribution with your DMPS/SMPS and log the data for at least four scans. Run 1a: Sizing of 101nm latex spheres: You will see a high noise level below the particle number size distribution. You have to adjust the mixture (droplets of latex solution and deionized water) so that you can at least see the peak of the spheres around 101nm on top of the noisy distribution. Measurement and preparation

Example: size calibration with latex spheres (Dp = 101nm)

This experiment is the same as the last one. This time you will investigate 277nm spheres with your DMPS/SMPS system. Please clean the nebulizer carefully with deionized water before you start Run 1b. Please be sure that you also log the data of the CPC Experiment 1b (277nm spheres): Prepare a solution of four to eight droplets of 277nm spheres and 20ml of deionized water. Use the nebulizer to spray the particles. Measure the particle number size distribution with your DMPS/SMPS and log the data for at least four scans. Run 1b: Sizing of 277nm latex spheres: You will see a small noise level below the particle number size distribution. You have to adjust the mixture (droplets of latex solution and deionized water) so that the signal to noise ratio is best. You should be able to identify the singly, doubly, and triply charged particles in the raw (non-inverted) particle distribution. Measurement and preparation

Example: size calibration with latex spheres (Dp = 277nm)

This experiment is the same as the last one. This time you will investigate 420nm spheres with your DMPS/SMPS system. Please clean the nebulizer carefully with deionized water before you start Run 1c. Please be sure that you also log the data of the CPC Experiment 1c (420nm spheres): Prepare a solution of four to eight droplets of 420nm spheres and 20ml of deionized water. Use the nebulizer to spray the particles. Measure the particle number size distribution with your DMPS/SMPS and log the data for at least four scans. Run 1c: Sizing of 420nm latex spheres: You will see a small noise level below the particle number size distribution. You have to adjust the mixture (droplets of latex solution and deionized water) so that the signal to noise ratio is best. You should be able to identify the singly, doubly, and triply charged particles in the raw (non-inverted) particle distribution. Measurement and preparation

Example: size calibration with latex spheres (Dp = 420nm)

Please provide the set up exactly how it is shown in the sketch on the next slide. The set up is thought to make a comparison of the measured number concentration of atmospheric particles between your system and the CPC 3022 with well-known efficiency. You can use the inlet system that is used for your continuous measurements also. Plug your inlet for atmospheric particles to the dilution chamber and close all inlet connections of the dilution chamber. Connect your DMPS/SMPS together with the CPC 3022 to the dilution chamber. Preparing the set up (number concentration)

DMPS/SMPS intercomparison set up Mixing Chamber DMA CPC Reference 2.0 lpm Supplied by Lund Bipolar Charger Drier c Your system operated at defined flowrates Flowrate = DMPS/SMPS + CPC Aerosol inlet for atmospheric particles All inlets closed c Your aerosol inlet

The following experiment will give information about the number concentration your system is measuring. Please be sure that you also log the data of the CPC. Experiment 2: Measure the particle number size distribution with your DMPS/SMPS and log the data over a period of at least two days. Run 2: A typical particle number size distribution is shown for atmospheric aerosols. The calculated total particle number after inversion should match the measured value of the CPC 3022 for periods when the particle number beyond the size range of your system and the CPC 3022 (7nm – 10μm) is negligible small. Measurement and preparation

Please prepare two EXCEL files for each run. One file should contain the raw data giving the measured concentration for each mobility channel. The second file should contain the inverted particle number size distribution in dN/dlogdp. Please provide the data format as shown in the example files. Please provide one info file for the raw data (which corrections are already done?) and one info file for the inverted data (which corrections are finally done?). Additionally, please fill in the provided excel sheet giving the system parameters like size range, scan time, etc. So far, so good. Have fun with our fictive intercomparison DMPS/SMPS workshop! Data format