The Science Behind Taxus Advanced Angioplasty 2004 Christian Vander Velde, Boston Scientific Europe, Marketing.

Slides:



Advertisements
Similar presentations
Copyleft Clinical Trial Results. You Must Redistribute Slides PEPCAD II ISR Study Paclitaxel-eluting devices: randomized comparison of the SeQuent™ please.
Advertisements

“Real World”: SVG, De Novo or Restenotic Coronary Artery Lesions Chronic Stable Angina, Silent Ischemia, Acute Coronary Syndromes Vessel Diameters:
M.Unverdorben; ACC March 2008 Martin Unverdorben Rotenburg/Fulda, Germany and Richmond, VA, USA Clinical Research Institute, Center for Cardiovascular.
Pathologic Intimal Hyperplasia as a Response to Vascular Injury and Reconstruction.
The TAXUS™ Paclitaxel-Eluting Stent Program. The safety and effectiveness of the TAXUS ™ Express 2 ™ Stent has not been established in patients with coronary.
PCI Unmet Clinical Needs
Stents Are Not Enough: Statins Keith Channon Department of Cardiovascular Medicine University of Oxford John Radcliffe Hospital, Oxford.
Four Drug Eluting Stent Trials Keith D Dawkins MD FRCP FACC Southampton University Hospital Keith D Dawkins MD FRCP FACC Southampton University Hospital.
Drug Eluting Stents – The Cell Biology Andrew Newby BRISTOL HEART INSTITUTE ?
Martin B. Leon, MD Columbia University Medical Center Cardiovascular Research Foundation New York City SOLACI 2009 June 10-12, Rio de Janeiro, Brazil Sustained.
Angioplasty’s Fight against Restenosis: Drug Eluting Stents & Bare Metal Stents.
Sirolimus Eluting Coronary Stent System with a Biodegradable Polymer
Vascular wall biology with current generation stents Professor Martin Bennett BHF Professor of Cardiovascular Sciences, Cambridge.
Stenting: Function, Problems, and Procedure. Uses for Stents  Peripheral artery disease (PAD)  Renal vascular hypertension  Hemodialysis access maintenance.
The Emerging Paradigm of Stent Biocompatibility: Current Status and Future Directions Dr Miles Dalby Consultant Cardiologist Honorary Senior Lecturer Royal.
BIOSENSORS-CLINICAL UPDATE “LEADERS AND BEYOND” John E Shulze, CTO BIOSENSORS INTERNATIONAL GROUP Jan 29, 2010.
Excessive SMC growth within the vascular wall after trauma -proliferation -apoptosis -migration - accelerated matrix deposition major cause of failure.
Trials of radiation to prevent or reduce in-stent restenosis Clinical Trial Commentary Dr Eric Topol Chairman and Professor, Department of Cardiology Director.
Keith Dawkins MD FRCP FACC FSCAI Chief Medical Officer Senior Vice President Boston Scientific Corporation Why Boston Scientific Persists with the Two-Drug.
TITAX AMI Trial Y. Giraud-Sauveur on behalf of P.Karjalainen, MD, PhD : Principal Investigator BCIS 2009 London, UK A Prospective, Randomized Trial Comparing.
Medtronic CardioVascular Interventional Pipeline 1.
Project #2: Hemodynamic Evaluation of Arteriovenous Fistula
Rapamycin- and Paclitaxel-Eluting Stents With Identical Biodegradable Polymeric Coating and Design Trial Presented at The American College of Cardiology.
TAXUS IV 2-Year Clinical Results The safety and effectiveness of the TAXUS TM Express 2TM Paclitaxel-Eluting Coronary Stent System have been established.
Treatment of In-Stent Restenosis by Paclitaxel Coated PTCA Balloons Presented at The American Heart Association Scientific Session 2006 Presented by Dr.
Upendra Kaul, MD for the TUXEDO INDIA Investigators Paclitaxel Eluting Versus Everolimus Eluting Stents in Patients with Diabetes Mellitus and Coronary.
TAXUS ATLAS Trial Presented at The EuroPCR meeting Paris, France May 2006 Presented by Dr. Mark Turco TAXUS ATLAS 9-Month Results: Evaluation of TAXUS.
Upendra Kaul, MD for the TUXEDO INDIA Investigators Paclitaxel Eluting Versus Everolimus Eluting Stents in Patients with Diabetes Mellitus and Coronary.
Reservoir Based Drug Delivery The CoStar™ System and Beyond Jeff Shanley Founder and Chief Technology Officer.
WHY TITAN WORKS AGAINST RESTENOSIS?. INTRODUCTION THE CELL MODEL THE HUMAN THE ANIMAL MODEL CONCLUSION WHY TITAN WORKS AGAINST RESTENOSIS ?
Slow-rate release polymer-based paclitaxel- eluting stent compared with bare stent in patients with single complex coronary lesions TAXUS V Presented at.
A Prospective, Randomized Trial Evaluating a Paclitaxel-Eluting Balloon in Patients TReated with Endothelial Progenitor Cell CapTuring Stents for De Novo.
1 Efficacy of a novel anti-inflammatory drug-eluting balloon coated with genistein before stent implantation in porcine coronary arteries I. Sheiban, C.
Boston Scientific Drug eluting stent program A Scientific Approach Identify therapeutic agent Identify appropriate polymer carrier Evaluate a broad range.
Journal Club Julie Shah, MD Milton S Hershey Medical Center Penn State University.
The REVA Tyrosine-Derived Polycarbonate Bioresorbable Scaffold: Long-term Outcomes Using Multimodality Imaging Greg L. Kaluza, MD, PhD, FACC Director of.
Learning Objectives Drawbacks of traditional POBA
DES arena THE CURRENT APPROACH TO DES MARKET IS BASED ON DRUG
Date of download: 7/6/2016 Copyright © The American College of Cardiology. All rights reserved. From: Vascular Inflammation and Repair: Implications for.
Real-world clinical experience with an everolimus eluting platinum chromium stent with an abluminal biodegradable polymer – a report from the Swedish Coronary.
Bare Metal Stent Self Expandable Stent Balloon Expandable Stent
DRug Eluting Bbsorbable Metal Scaffold (DREAMS)
Boston Scientific Corporation: DES Bioabsorbable Technologies
Josiah N. Wilcox, Ph.D. Chief Scientific Officer
Regulatory Challenges for Bioabsorbable Stent Approval
Kinesyx™ Oligomer Technology for Drug Delivery:
Abbott Vascular Bifurcation Program
Regulatory Considerations for Coronary Drug Coated Balloons (DCBs)
From: Paclitaxel-Eluting Stents vs Vascular Brachytherapy for In-Stent Restenosis Within Bare-Metal StentsThe TAXUS V ISR Randomized Trial JAMA. 2006;295(11):
One DES Eluting Two Drugs: Is it Feasible? Robert Falotico, PhD
Date of download: 10/27/2017 Copyright © ASME. All rights reserved.
Bioabsorbable DES and Biodegradable Polymers – FDA View
One DES Eluting Two Drugs: Is it Feasible?
Harmonized Assessment by Randomized Multicenter Study of OrbusNEich’s COMBO StEnt Japan-USA HARMONEE: Primary Report of A Randomized Trial of a Bioabsorbable.
Greg L. Kaluza, MD, PhD, FACC Cardiovascular Research Foundation
DES Bioabsorbable and DCB Technologies
TAXUS IV Trial Slow-rate release polymer-based paclitaxel-eluting stent compared with bare stent in patients with single de novo coronary lesions Presented.
Insights from the IMPERIAL and MAJESTIC SFA Studies
Mouse Carotid Artery Ligation Induces Platelet-Leukocyte–Dependent Luminal Fibrin, Required for Neointima Development by Tomihisa Kawasaki, Mieke Dewerchin,
Stenting of Coronary Arteries in Non Stress/Benestent Disease
The OrbusNeich EPC Capture Biodegradable Polymer Sirolimus-eluting Stent Program Michael JB Kutryk, MD, PhD St Michael’s Hospital, Toronto.
AcoArt I Trial design: Patients with femoropopliteal artery disease were randomized to paclitaxel-coated balloon angioplasty (n = 100) vs. standard peripheral.
TAXUS II and IV: two-year follow-up
FAIR Trial design: Patients with SFA in-stent restenosis (ISR) were randomized to either a paclitaxel-coated balloon (DCB) (dose 3.5 μg/mm2) or routine.
BASKET-PROVE II Trial design: Subjects with stable or unstable coronary artery disease undergoing stent implantation were randomized to a biodegradable-polymer.
Presented at ACC 2003 Late Breaking Clinical Trials
Fig 6.1 Drug released by diffusion
Inhibition of experimental neointimal hyperplasia and neoatherosclerosis by local, stent- mediated delivery of everolimus  Hugh Q. Zhao, PhD, Alexander.
Boston Scientific, MN, USA Travis Schauer and Ismail Guler
Drug-eluting coronary stent market overview
Presentation transcript:

The Science Behind Taxus Advanced Angioplasty 2004 Christian Vander Velde, Boston Scientific Europe, Marketing

TAXUS Technology Binds tubulin Microtubular dynamics Multifunctional Binds tubulin Microtubular dynamics Multifunctional Uniformity Durability Biphasic Controlled Release Kinetics Uniformity Durability Biphasic Controlled Release Kinetics Express ™ Stent Tandem Architecture Flexibility Maverick ™ Balloon Deliverability Express ™ Stent Tandem Architecture Flexibility Maverick ™ Balloon Deliverability Paclitaxel Polymer Platform

TAXUS Technology - Paclitaxel Restenotic Cascade The Ideal Pharmaceutical Should Control The Ideal Pharmaceutical Should Promote Inflammatory Cells SMC Proliferation SMC Migration ECM 0–2 Days 2–4 Days 4–10 Days 10–14 Days 2–4 Weeks Platelet Aggregation Endothelialization Table adapted from the experimental models by Ferns et al.

– Paclitaxel is a multi-functional drug which effectively: Inhibits proliferation Inhibits migration Inhibits inflammation Inhibits secretion – Paclitaxel is a multi-functional drug which effectively: Inhibits proliferation Inhibits migration Inhibits inflammation Inhibits secretion TAXUS Technology - Paclitaxel Promotes Endothelialization Restenosis Prevents Paclitaxel selectively impacts smooth muscle cells, platelets, and white blood cell activity without affecting endothelial cells – Paclitaxel enables healing by selectively impacting the cells that cause restenosis while allowing healthy healing of endothelial cells TAXUS shows similar healing between control bare metal stent and paclitaxel Endothelialization of a paclitaxel-eluting stent in a porcine coronary artery Axel et al, AHA 1997, Karsch et al, SIC 1998

Polymer Carrier Considerations Chemical/Physical and Biological Formulate/process CoatingIntegrity Sterilization Drug Loading Drug release Biocompatible Vascularcompatible

Smooth, Uniform Coverage Smooth, Uniform Coverage No Cracking, Flaking or Delaminating No Cracking, Flaking or Delaminating Coating Integrity BSC Carrier- Translute TM 200x 40x Coated, Loaded, Sterilized, Expanded

Uniform PTx Content Along Stents of Different Lengths (15, 24, 32 mm stents -- 1ug/mm 2 )

Uniform PTx Release From Express TM Stents of Different Lengths 1.0 ug/mm 2, Slow release 16 mm 1.0 ug/mm 2, Slow Release 24 mm 1.0 ug/mm 2, Slow Release 32 mm

Polymer-based Clinical Data TRIAL DOSE OF PTx LATE LOSS mm TAXUS I 1.0ug/mm2 SR / TAXUS II 1.0ug/mm2 SR / TAXUS II 1.0ug/mm2 MR / TAXUS IV 1.0ug/mm2 SR / Confirmed by IVUS analysis (TAXUS II - Circulation January 20, 2004) TRIAL DOSE OF PTx LATE LOSS mm TAXUS I 1.0ug/mm2 SR / TAXUS II 1.0ug/mm2 SR / TAXUS II 1.0ug/mm2 MR / TAXUS IV 1.0ug/mm2 SR / Confirmed by IVUS analysis (TAXUS II - Circulation January 20, 2004)

In Vivo Considerations for Polymers and Drugs Animal Model Animal Model – Rat – Rabbit – Swine – Canine Implant Time Implant Time Implant Location Implant Location – Sub Q – IM – Iliac – Coronary Other Other In Vivo Studies, !!!!

Polymer Carriers Vascular Compatibility Bare Stent Polyurethane-coated Stent (2 months) In Collaboration w/Drs. Rogers and Edelman,MIT Sub-optimal drug carriers can cause severe inflammatory response Failed candidates (normal porcine coronary model)

Effect of Animal Model and Implant Site Rat Subcutaneous Implant Model Bare Stent Polyurethane-coated Stent 28 day Implant - H&E Staining

Effect of Animal Model and Implant Site Bare Stent Polyurethane-coated Stent In Collaboration w/Drs. Rogers and Edelman,MIT Porcine Coronary 28 day

28 day PLA/PCL coated stent 56 day PLA/PCL coated stent In Collaboration w/Drs. Rogers and Edelman, MIT Rabbit Iliac Artery Effect of Animal Model and Implant Site

35 day PLA/PCL In Collaboration w/Drs. Rogers and Edelman, MIT Porcine Coronary Artery Effect of Animal Model and Implant Site

Vascular Compatibility Translute TM 180D Bare control 180D polymer coated 90D polymer coated 90D Bare control In collaboration with Dr. Rob Schwartz Mayo Clinic and Dr. Greg Wilson Sick Children’s-Toronto

180 day Translute only Express stent Good safety profile Good safety profile Polymer similar to control Polymer similar to control Reproduced from lot to lot Reproduced from lot to lot Translute Polymer Long term (180 days) vascular compatibility In collaboration with Dr. Rob Schwartz Mayo Clinic and Dr. Greg Wilson Sick Children’s-Toronto

Inflammation (CD45, 0-4) Endothelial coverage (PECAM 1, 0-5) Bare Polymer-coated % Luminal Stenosis No significant differences Vascular Compatibility Translute TM In Collaboration w/Drs. Rogers and Edelman,MIT

TAXUS Technology - Translute™ Polymer Polymer-based matrices provide: ease of handling ease of handling uniform dose along stent and dosing in a controlled manner = consistency uniform dose along stent and dosing in a controlled manner = consistency a matrix by which drug release can be manipulated to achieve a desired biological response a matrix by which drug release can be manipulated to achieve a desired biological response Polymer-based matrices provide: ease of handling ease of handling uniform dose along stent and dosing in a controlled manner = consistency uniform dose along stent and dosing in a controlled manner = consistency a matrix by which drug release can be manipulated to achieve a desired biological response a matrix by which drug release can be manipulated to achieve a desired biological response With greater opportunities come greater challenges

Translute TM Polymer stability  Translute TM coating integrity was maintained in 10-year equivalency tests*  The Translute TM polymer has shown remarkable stability out to two years in an animal model*  Harsh conditions (alcohol storage, mild heat, agitation) fail to degrade the polymer*  Tests have shown that following physical abrasion of the polymer, the release is not markedly increased* * data on file

Thank You !