Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015.

Slides:



Advertisements
Similar presentations
Ultimate performance of relativistic electron cooling at Fermilab A. Shemyakin and L. R. Prost (Fermilab) September 15, 2011 COOL’11 A eulogy (from εὐλογία,
Advertisements

1 Proton Upgrades at Fermilab Robert Zwaska Fermilab March 12, 2007 Midwest Accelerator Physics Collaboration Meeting Indiana University Cyclotron Facility.
Run 2 PMG 2/16/06 - McGinnis Run II PMG Stacking Rapid Response Team Report Dave McGinnis February 16, 2006.
F.Brinker, DESY, July 17 st 2008 Injection to Doris and Petra Fitting the detector in the IP-region Radiation issues Beam optic, Target cell Polarisation.
 An h=4 (30 MHz) RF system will be used for electron operation. For protons, this would correspond to h=56, and the 1 kV maximum gap voltage would only.
ALPHA Storage Ring Indiana University Xiaoying Pang.
The 2nd Tevatron Electron Lens and tests of a new electron gun in the framework of Beam-Beam Compensation project Yu. Alexahin, V. Kamerdzhiev, G. Kuznetsov,
Sergey Antipov, University of Chicago Fermilab Mentor: Sergei Nagaitsev Injection to IOTA ring.
Test of the high voltage strength of Pelletron’s gas insulation (18-Dec-2008) Recycler Meeting January 21, 2009 A. Shemyakin.
Electron Cooling in the Recycler Ring Alexander Shemyakin (Fermilab/AD) May 31, 2005.
Pelletron Battle – Field Report All Experimenters’ Meeting August 15, 2011 L. Prost (for A. Shemyakin)
COULOMB ’05 Experiments with Cooled Beams at COSY A.Lehrach, H.J.Stein, J. Dietrich, H.Stockhorst, R.Maier, D.Prasuhn, V.Kamerdjiev, COSY, Juelich, I.Meshkov,
AAC 2006V.Shiltsev 1 Electron beam generation and control in Tevatron Electron Lenses Vladimir Shiltsev, R.Hively, V.Kamerdzhiev, G.Kuznetsov, H.Pfeffer,
Simulation of direct space charge in Booster by using MAD program Y.Alexahin, N.Kazarinov.
F MI High Power Operation and Future Plans Ioanis Kourbanis (presented by Bruce Brown) HB2008 August 25, 2008.
Eric Prebys, FNAL. USPAS, Knoxville, TN, January 20-31, 2014 Lecture 20 - Cooling 2 Anti-protons are created by hitting a target with an energetic proton.
Recycler Status and Plans Shekhar Mishra MID/Beams Division Fermilab AAC Review 2/4/03 Introduction to the Recycler Ring Recycler Improvements and status.
High Current Electron Source for Cooling Jefferson Lab Internal MEIC Accelerator Design Review January 17, 2014 Riad Suleiman.
AAC February 4-6, 2003 Protons on Target Ioanis Kourbanis MI/Beams.
October 4-5, Electron Lens Beam Physics Overview Yun Luo for RHIC e-lens team October 4-5, 2010 Electron Lens.
Electron cooling at the Recycler: Update and Cooling force characterization October 19 th, 2006 L. Prost, Recycler Dpt. personnel Fermi National Accelerator.
Simulation of direct space charge in Booster by using MAD program Y.Alexahin, A.Drozhdin, N.Kazarinov.
1 EPIC SIMULATIONS V.S. Morozov, Y.S. Derbenev Thomas Jefferson National Accelerator Facility A. Afanasev Hampton University R.P. Johnson Muons, Inc. Operated.
Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004.
Alexei Fedotov, 02/02/12 1 Potentials for luminosity improvement for low-energy RHIC (with electron cooling) February 2, 2012.
Stability of the electron energy Recycler department meeting April 5 th, 2006 A. Shemyakin, M. Sutherland.
Luminosity expectations for the first years of CLIC operation CTC MJ.
1 FFAG Role as Muon Accelerators Shinji Machida ASTeC/STFC/RAL 15 November, /machida/doc/othertalks/machida_ pdf/machida/doc/othertalks/machida_ pdf.
Overview of Electron Cooling Activities at FNAL Thomas Kroc Fermilab – Electron Cooling EIC 2004 March 15-17, 2004 Jefferson Lab.
Paul Derwent 14 Dec 00 1 Stochastic Cooling Paul Derwent 14 Dec 00
Electron energy stability: analysis from snapshot data and temperature stabilization Recycler Departmental Meeting May 21, 2008 A. Shemyakin 1.Analysis.
Overview: Primary Sensitivities Nov S. Childress Page 1 NuMI Overview: NuMI Primary Beamline Sensitivities NuMI requirements are for a very large.
A simple formula for calculating the momentum spread from the longitudinal density distribution and RF form Recycler Meeting March 11, 2009 A. Shemyakin.
Overview of Booster PIP II upgrades and plans C.Y. Tan for Proton Source group PIP II Collaboration Meeting 03 June 2014.
Accumulator Stacktail Cooling Paul Derwent December 18, 2015.
LDRD: Magnetized Source JLEIC Meeting November 20, 2015 Riad Suleiman and Matt Poelker.
1 EMMA Tracking Studies Shinji Machida ASTeC/CCLRC/RAL 4 January, ffag/machida_ ppt & pdf.
Progress of Electron Cooling at the Recycler January 26 th, 2006 L. Prost, Recycler Dpt. personnel f Fermi National Accelerator Laboratory.
The SPS as a Damping Ring Test Facility for CLIC March 6 th, 2013 Yannis PAPAPHILIPPOU CERN CLIC Collaboration Working meeting.
Updated Overview of Run II Upgrade Plan Beam Instrumentation Bob Webber Run II Luminosity Upgrade Review February 2004.
Cooling of Hadrons at Relativistic Energies: Performance of FNAL’s Recycler Electron Cooler BNL – Collider-Accelerator Department Accelerator Physics Seminar.
July LEReC Review July 2014 Low Energy RHIC electron Cooling Jorg Kewisch, Dmitri Kayran Electron Beam Transport and System specifications.
The Introduction to CSNS Accelerators Oct. 5, 2010 Sheng Wang AP group, Accelerator Centre,IHEP, CAS.
Principals of fast injection and extraction R. Apsimon.
Robert R. Wilson Prize Talk John Peoples April APS Meeting: February 14,
F HCP 2007 Performance and Future of the Tevatron Ron Moore Fermilab - Tevatron Dept. Tevatron overview and performance Antiproton source + Recycler overview.
Electron energy stability (observations after the HV regulation repairs) Recycler Meeting April 30, 2008 A. Shemyakin.
Villars, 26 September Extra Low Energy Antiproton Ring (ELENA) for antiproton deceleration after the AD Pavel Belochitskii for the AD team On behalf.
Development of High Current Bunched Magnetized Electron DC Photogun MEIC Collaboration Meeting Fall 2015 October 5 – 7, 2015 Riad Suleiman and Matt Poelker.
6 July 2010 | TU Darmstadt | Fachbereich 18 | Institut Theorie Elektromagnetischer Felder | Sabrina Appel | 1 Micro bunch evolution and „turbulent beams“
Weekly Review of Operation Recycler departmental meeting November 14 th, 2007.
Review of Alignment Tolerances for LCLS-II SC Linac Arun Saini, N. Solyak Fermilab 27 th April 2016, LCLS-II Accelerator Physics Meeting.
From Beam Dynamics K. Kubo
Simulation of Luminosity Variation
Electron Cooling Simulation For JLEIC
LEIR IMPEDANCE AND INSTABILITY MEASUREMENTS
Beam-beam effects in eRHIC and MeRHIC
ELENA Overview and Layout Start of ELENA Commissioning Next Steps
Large Booster and Collider Ring
Jeffrey Eldred, Sasha Valishev
Task E - A0 and related activities
Multiturn extraction for PS2
Task E - A0 and related activities
ELENA Extra Low ENergy Antiproton Ring
Physics Design on Injector I
Update on ERL Cooler Design Studies
Fanglei Lin, Yuhong Zhang JLEIC R&D Meeting, March 10, 2016
Plans for future electron cooling needs PS BD/AC
Optimization of JLEIC Integrated Luminosity Without On-Energy Cooling*
Status of RCS eRHIC Injector Design
Presentation transcript:

Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

Outline Why Fermilab needed it Choice of the scheme Challenges, remedies and cooling optimization Operation 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences2

Tevatron luminosity and antiprotons The Tevatron luminosity is almost linear with respect to the total number of antiprotons available for Tevatron stores. Increase of antiproton production and improvement of the beam quality was the central component of the Tevatron Run II. 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences3 Average initial luminosity as a function of the number of antiprotons injected into the Main Injector. Shown are the stores in 2011.

Fermilab’s antiproton production chain Electron cooling in the Recycler Ring eliminated a bottleneck in the antiproton production chain. 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences4 Nickel target Proton beam 8  protons every 2.2 sec 120 GeV Debuncher (stochastic cooling) Accumulator (stochastic cooling) 8 GeV 1 TeV Tevatron 150 GeV Main injector 8 GeV Recycler (stochastic and electron cooling) 3   = 1    = 4   10 8  = 1 1  10 8  = 300 until  10 12

COOLER DESIGN SCHEME 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences5

Cooler’s features 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences6 Electrostatic accelerator –4 MeV  0.5 A = 2 MW DC Energy recovery; very low beam losses; overcoming high voltage discharges Novel transport scheme –Longitudinal magnetic field in the cooling section and in the gun with lumped focusing in between –100 G in cooling section; 10 solenoids The solution allowed building the cooler with a modest budget and in time for Run-II Design parameters of the RR ECool Energy4.3 MeV Beam current (DC)0.5 Amps Angular spread0.2 mrad Effective energy spread 300 eV RR = Recycler Ring Primarily for longitudinal cooling –Required cooling times were many minutes

Transport with interrupted longitudinal magnetic field Longitudinal magnetic field in the cooling section and in the gun with lumped focusing in between 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences7 Cathode Cooling section Beam line B z = 0 R = mm (normalized) B c z = 90 G R cath = 3.8 mm ( normalized) B c z = 105 G R beam = 3.5 mm ( normalized) The transverse velocities in the cooling section can be low only if the magnetic fluxes through the emitter and the beam in the cooling section are equal. Outside of the field, the beam behavior is dominated by an effective emittance proportional to the magnetic flux through the emitter

Applicability When is the scheme with interrupted magnetic field applicable? –The figure of merit is the magnetic flux through the beam in the cooling section and the energy –The scheme can work when the required beam radius and the magnetic field in the cooling section are low and the energy is high Cooling time required from RR Ecool is many minutes –Cooling is adequate without effects of strong magnetization Typical rms radius of the antiproton beam is 1-2 mm –Electron beam size can be similar Outside of the magnetic field, the (non-normalized) effective emittance is tolerable, ~4  m 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences8

Cooler in the Recycler Ring 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences9 Portion of the Main Injector tunnel containing the cooling section and the “return” line. The Pelletron and beam “supply” and “transfer” lines 20 m February, 2005 beginning of commissioning

Some useful decisions Long off-line testing Nominally “round” optics in the supply line Zero dispersion in the cooling section High dispersion after the cooling section to measure energy drifts Placement of elements with tuning convenience in mind –Each solenoid is followed by dipole correctors and, after a drift space, by a BPM right upstream of the next solenoid Data logging of all parameters Well–thought procedure of energy tuning Initial transverse tuning with round orifices in the cooling section (“scrapers”) 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences10

CHALLENGES, REMEDIES & COOLING OPTIMIZATION 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences11

Difficulties Magnetic fields from the Main Injector –Compensation of bus currents, additional magnetic shielding –Changes in optics that made the system more tolerable to the beam motion First energy matching –Absolute energy calibration of the electron beam by measuring the electron Larmor wave length in the magnetic field of the cooling section –A special wide energy distribution of antiprotons to observe the first interaction between beams Full discharges, stability of operation –Lots of work but not discussed here Energy stability –Temperature stabilization –Feedback from e-position in a high-dispersion region –“Peakiness” of the Schottky distribution after cooling Tuning, life time –See in following slides 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences12 Δp/p=3% One of the first indications of interaction between antiprotons and electrons. More later on

Drag rates and cooling rates 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences13

Drag rate measurements Coasting “pencil” antiproton beam (N p ~1×10 10 ); changes in average momentum are recorded after a jump of electron energy; drag rate = time derivative of the average momentum Drag rate ≈ longitudinal cooling force for an “average” particle 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences14 Example of evolution of the mean and rms values of the momentum distribution after a 1.9 keV e-energy jump. The drag rate is 71 (MeV/c)/hr. I e = 0.5 A.

Cooling force as a function of the beam current In all measurements, the voltage jump was 2 kV and the electron beam was “on axis”. All points in each curve are taken at constant focusing settings 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences15

Cooling force as a function of the beam current At low beam currents, main improvements came from –Alignment of the field in the cooling section –Adjustment of quadrupole focusing All adjustments were made at I e = 0.1A 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences16

Cooling section field alignment Procedure: Optimize 10 pairs of correctors in each module measuring the cooling force produced by the module. –Tilt or shift of the solenoid results in dipole fields similar to fields generated with either 8 pairs of central correctors or 2 pairs of end correctors 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences17 The cooling section consists of 10 identical modules, which are rigid but can move with respect to one another due to tunnel deformations, hence creating field errors. I.Area being measured II.Transition area (large angle) III.Large offset (4 mm with the electron beam radius ~2.3 mm) Drag rate as a function of a change in currents of all 8 central X correctors by the same amount in module #3.

Adjustments of focusing There were several indications of large focusing errors –In part, drag rates measured across the beam were dropping with the offset much faster than the calculated electron beam density Beam imaging at a YAG scintillator showed a large ellipticity –Could be corrected with quadrupoles –YAG  pulse mode, where focusing was different from DC Could not use it for an effective DC tuning 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences18 Quadrupoles YAG location Images of the beam with zero (1 and 2) and optimized (3 and 4) quadrupole currents. I e ~ 0.1A, 2µs pulse.

Adjustments of focusing (cont.) Tuned quadrupoles based on the drag rate measurements (off-axis) –Maximizing the drag rate for each of 6 quadrupoles Cooling rates increased by ~1.5 times longitudinally and by ~2 times transversely (at I e = 0.1A) 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences19 Typical cooling rate measurement (October 26, 2007). I e ~ 0.1A, beam on axis, focusing settings include quadrupoles. Transverse emittances measured with flying wires. Longitudinal cooling rates at various vertical offsets of the electron beam before (set 2) and after (set 1) adjustments of quadrupoles. I e ~ 0.1A.

Improvements at high beam current At higher beam currents, the main improvement came from ion clearing Tuning was made mainly at I e = 0.3A 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences20

Ions - Effect While at I e = 0.1A the drag rates drops with offset smoothly, at I e = 0.3A there are three narrow areas of good cooling Hypothesis: the reason is a highly non-linear focusing effect of ions Proposed remedy: clear ions by interrupting the electron current for a microsecond –In the beam electric field, the ions gain a high transverse velocity (W i ~10 eV) to reach the wall in ~1 µs after turning the beam off. 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences21 Contour plots of drag rates. Left - I e = 0.3A, Right - I e = 0.1A. Contour levels are in MeV/c/hr.

Ions - Removal The capability to interrupt the beam for 2 – 20 µs at frequencies up to 100 Hz was implemented Strong dependence of drag rates on the interruption frequency –Naturally, the rate is maximum where it had been optimized –Duration of the interruptions doesn’t have any measurable effect 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences22 Drag rate as a function of the interruption frequency for I e = 0.3 A (left) and 0.1 A (right). The interruption length was 2 µs; beams were on axis. The squares represent the data, and the solid lines are fits. Focusing was optimized at 15 Hz for 0.3 A and with no interruptions for 0.1A (January 26, 2010).

Cooling with ion clearing While cooling improved significantly, we couldn’t use it to its full strength in operation because of an antiproton instability. –Also, the beam trips are more frequent at higher electron currents –In 2011, we used I e = 0.2 A and ion clearing in the time of beam preparation for Tevatron shots 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences23 Longitudinal cooling rate measured in The arrows connect points measured on the same day to show the range of several improvements. All measurements are “on axis”. Contour plot of drag rates with ion clearing. I e =0.3A, 100 Hz. Contour levels are in MeV/c/hr.

Summary of cooling improvements Tuning of focusing with quadrupoles Alignment of the magnetic field in the cooling section Ion clearing All improvements of cooling properties were made through decreasing the transverse electron velocities (angles) in the cooling section –The main study tool was the drag rate measurements –The total rms angle is decreased probably by 1.5 – 2 times 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences24 Drag rate as a function of momentum offset. I e = 0.1A, focusing is optimized for ion clearing, 100 Hz. The circles are data, and the solid line is a calculation with θ t = 80µrad, δW e = 200eV, L c = 9. January 4, θ t - electron angle, δW e – energy spread

OPERATION 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences25

Recycler cooling cycle Efficient storage of antiprotons and cooling them for shots to the Tevatron –Typical beam loss due to the finite life time in the Recycler is ~5% –Number of stored antiprotons is up to 6·10 12 with a life time > 300 hrs –Phase density at extraction is limited by an instability 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences26 Typical cycle of accumulation of antiprotons in the Recycler ring and following extraction. June 17-18, Electron beam was kept at 0.1A, shifted by 2 mm from the axis except right before extraction, when it was switched to 0.2A in ion clearing mode and moved on axis. Average life time was 256 hours.

Cooling July 9, 2005 – First indication of the cooling force The cooler’s performance was significantly improved and optimized –Procedures for tuning, feedback loops, automation… –Optimization of the cooling scenario Cooling off – axis Cooling with a helical trajectory Increasing the electron beam current for final cooling before extraction Significant efforts for maintenance –When the cooler was ‘broken’, the rate of integrating luminosity was dropping by ~3 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences27 Electron beam “On axis” 2 mm offset ~95% of antiprotons

Availability/Reliability Pelletron ran 24/7 and was turned off only when either a component had failed or during planned shutdowns (~once a year) –Beam ‘interruptions’ (short) Beam trips: –Protection system turns off the beam if a drop of HV by >5 kV or other problem is detected – < 1 trip per day –~20 s to recover Full discharges: –Unprovoked: ~once a year –1-3 hours to fully recover –Failures (long down time) The worst situation is to have to go into the Pelletron tank –8-10 hrs to open, 6-8 hrs to close Typical turn-around time ~ 36 hrs –Normally, several accesses per year Mostly, to repair electronics 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences28

Electron beam energy drift Electron energy drift –Corrected with a feedback loop based on BPM reading in a high- dispersion area –Adjustments to an ‘energy parameter’ based on the Schottky longitudinal distribution profile 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences29 Measured dispersion in the electron beam line. The horizontal axis shows the BPM number counted along the beam line. Reading of the vertical channel of the first BPM after the 180 deg bend deviates with the energy change as 0.33 mm/keV. Equilibrium momentum distribution of antiproton beam for cooling at two electron energies. Blue- optimum energy tuning, red - the electron energy is shifted by 1.2 keV; electron beam is on axis.

Impedance-driven instability (transverse) Due to own space charge of pbars when deeply cooled –Dampers suppressed them very efficiently –A few were observed during extraction process Complicated RF gymnastics Defined a ‘phase density’ parameter –Monitored on-line –Kept far from the calculated (and experimentally determined) instability threshold 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences30 Vertical damper kick [%] 40 min Number of pbars [e10] Horizontal emittance (n, 95%) [  mm mrad] Vertical emittance (n, 95%) [  mm mrad] Vertical damper kick [%] Horizontal damper kick [%] Electron beam current (0.1 A) ~20e10 loss ~10 s Instability before extracting bunch #7 # of pbar  Emittances in eV ∙ s &  rad antiproton ≡ ≡ pbar

Life time Life time was always worse with the electron beam on than without it –Vacuum limit with stochastic cooling: ~1000 hrs –In operation with electron cooling; 100 – 500 hrs –No comprehensive explanation, but likely the main effect is related to formation of a cold core Life time might be decreasing even when transverse emittance was shrinking Strongest correlation was with the peak antiproton beam current –Some electron beam –induced diffusion is possible as well 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences31 Observation that might be relevant: Life time of protons in RR was dropping from tens of hours to seconds if the electron beam was on Life time improvements: –“Off-axis” cooling –Cooling with a helix trajectory Example of dependence of the antiproton life time at equilibrium on peak current of the antiproton beam. Dec 2, 2008 – Jan 7, I e = 0.1A.

Summary of lessons learned Procedure of the beam line tuning needs to be thought ahead and taken into account while placing components –Both for initial tuning and operation Alignment of a 20-m cooling section can be significantly affected by ground motion Ions need to be carefully cleared from a relativistic electron beam Life time of the cooled beam may decrease with electron cooling 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences32

Final words Unique electron cooler –High energy (4 MV), huge beam power (2 MW) –Low magnetic field in the cooling section with lumped focusing outside ‘Non-magnetized’ cooling Transport of a beam with large effective emittance Reliable machine running 24/7 The Recycler Electron Cooler significantly contributed to the success of Run-II –i.e. property of cooling and overall operation of the cooler satisfied the needs (and maybe beyond expectations) 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences33

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences34 For more information: –A. Shemyakin and L. R. Prost, The Recycler Electron Cooler, arXiv: –S. Nagaitsev, L. Prost and A. Shemyakin, Fermilab 4.3 MeV electron cooler, JINST 10 T01001 (2015), arXiv: References

BACK-UP SLIDES 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences35

Choice of the scheme (I) Based on SSC MEB proposal for relativistic cooling –No longitudinal magnetic field at the gun –Lumped focusing in the cooling section Pros –Use of industrially-manufactured electrostatic accelerator –Cooling section simpler than for strong continuous focusing Significantly cheaper too Cons –Low transverse velocities in cooling section  large value of the  - function  susceptible to perturbations Drift instability from wall image charges Ion instability –Ineffective cooling inside the lenses Large azimuthal velocity 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences36

Choice of the scheme (II) Combine advantages from longitudinal magnetic field in the cooling section and lumped focusing in the transport lines The main reason: the scheme without continuous longitudinal magnetic field looked doable in the time frame useful for the Tevatron Run II. Also, –Pelletrons have had the terminal potential up to 25 MV Known for being reliable machines –Cheaper –Easier to incorporate into the existing MI/RR tunnel 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences37

Beam recirculation Initially, insufficient stability  main obstacle during R&D and early commissioning Remedies: –Increase total length of acceleration tubes 5 MV nominal → 6 MV nominal –Fast protection circuitry 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences38 Oscillograms of ‘fast’ (red) and ‘slow’ (blue) discharges recorded by the fast capacitive pickup (Fast CPO) that measures the terminal voltage ‘drop’ (the terminal voltage actually becomes more positive) Oscillograms of a recirculation interruption, showing the effectiveness of the fast gun shut off

Beam recirculation ‘remedies’: Gun and Collector Developed gun and collector allowed a high beam current with low loss. The best results: –At a low-energy test bench: 2.6 A, relative beam loss 2·10 -6 –4.3 MeV beam, short beam line: 1.8 A, relative beam loss 1.2·10 -5 –4.3 MeV beam, full beam line: 0.6 A, relative beam loss 1.6·10 -5 The likely reasons for the higher beam loss with the longer beam lines are interaction with the residual gas and the energy spread increase due to IBS 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences39 Anode current and changes in the deceleration tube current as functions of the beam current. Full line; ion clearing mode (December 31, 2011.). Pelletron HV Terminal Gun Collector

Beam recirculation ‘remedies’: Beam optics Adjust beam envelope in deceleration tube to transport out electrons coming out of the collector Adjust beam envelope in acceleration tube so that beam core remains far from the tube electrodes when the beam trips –Big difference in the occurrence of full discharges originating in the acceleration tube. Protection of deceleration tube from irradiation when the beam trips by using optics with high dispersion in the return line 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences40 Simulations of the beam envelope (edge) in the accelerating column for nominal settings (solid curve) and settings representing a partial discharge (dotted curve). The limiting aperture is 12 mm. Vertical dotted lines represent the locations of the magnetic lenses.

Energy drift Temperature – related –Pelletron temperature –GVM preamplifier temperature Caused by changing balance of currents –Chain current variation Was a problem in the time of charging efficiency degradation –Variation of the beam loss or corona current Changes in GVM reading associated with SF 6 permittivity –At ~6 atmospheres (abs)  SF 6 = –The charge generated on GVM at a given voltage increases correspondingly –1% SF 6 pressure increase results at the same terminal voltage in the GVM reading increase by about 0.01% Results in 0.5 keV/psi energy drop Was noticed in the time of an SF 6 leak 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences41 Example of electron beam energy drift after turning the Pelletron on. Traces: energy deviation (2keV/div); SF6 temperature (5 K/div); GVM reading (2kV/div), and temperature of the GVM preamplifier(2 K/div).

Contribution of residual gas ions At I e = 0.1A, the potential difference between the beam center and the vacuum pipe is ~ 15 V. It is a deep well for thermal-energy ions (W i ~ 0.03 eV) created by the primary electrons. Focusing effect from the ions is higher than the defocusing effect from the beam space charge by ~  c  2, and can be large with  2 ≈100 –Simulations at optimized focusing:  =  ·r·  I e with  ~1 rad/A/m –Neutralization  c needs to be kept <1% at all relevant currents –Calculated time to reach  c ~1% is ~0.2s. H 2 at 0.3 nTorr Each BPM is used for ion clearing –One of the plates is biased at -300V while the other is grounded Thermal ions fly ~5m distance between BPMs in the supply line in ~ 3ms However, there are barriers for ions created by –Size variations of both the electron beam and the vacuum pipe –Solenoidal lenses –BPM clearing removes ions to ~2% (from fitting to measurements) Still not good enough 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences42

Angles in the cooling section Estimations of angles in the cooling section for the best case. –I e = 0.1 A. 1D values are shown. Difficult to come up with a defendable procedure of summation Agrees with cooling force measurements 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences43

Example: Oct’07-Oct’08 HV was on 92% of the time –Part of the downtime was not related to ECool problems –5 cases of HV regulation–related problems caused ~130 hours of downtime Continuing issue with GVM Near the end of the run, much less frequent –The next source of the downtime was the control system Interaction between NEC’s ACCELNET and Fermilab’s ACNET –Eventually, mostly resolved but not 100% free of hang-ups 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences44