Theory and Practice of Electron Microprobe Analysis Geoc 575 Nelia Dunbar Bureau Office B-101 x5783 office x5155 lab.

Slides:



Advertisements
Similar presentations
Ge 116 Module 1: Scanning Electron Microscopy
Advertisements

Chapter 12 Additional Analytical Methods. Analytical Methods Technique Type Technique application Subdivisions Specific application DescriptionDestruction.
Instrumental Chemistry
Bragg’s Law nl=2dsinΘ Just needs some satisfaction!! d Θ l
BY Assistant Professor Dr. Akram R. Jabur Department of Materials Eng. University Of Technology.
Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
Lecture 20 X-Ray Diffraction (XRD)
X-ray Diffraction. X-ray Generation X-ray tube (sealed) Pure metal target (Cu) Electrons remover inner-shell electrons from target. Other electrons “fall”
Lecture 21 (12/11/2006) X-Ray Diffraction (XRD) Theory and Analytical Technique.
Synchrotrons A synchrotron is a ring which uses magnets and electrodes to accelerate x-rays or light to nearly the speed of light These extremely bright.
Groups: WA 2,4,5,7. History  The electron microscope was first invented by a team of German engineers headed by Max Knoll and physicist Ernst Ruska in.
UWO Nanofabrication Facility and Science Studio. Facility to be hooked into Science Studio: Western Nanofabrication Facility, University of Western Ontario.
Internal – External Order We described symmetry of crystal habit (32 point groups) We also looked at internal ordering of atoms in 3-D structure (230 space.
Yat Li Department of Chemistry & Biochemistry University of California, Santa Cruz CHEM 146C_Experiment #3 Identification of Crystal Structures by Powder.
Scanning Electron Microscope Jamie Goings. Theory Conventional microscopes use light and glass lenses SEM uses electrons and magnetic lenses to create.
Electron Probe Microanalysis. A technique to quantitatively analyze samples for their chemical composition on a micro-scale (~1μm) Instrument: Known as.
Instrumental Chemistry Chapter 12 Atomic X-Ray Spectroscopic.
Surface Characterization by Spectroscopy and Microscopy
BY SANTANU PRAMANIK(09369) HITESH KUMAR GUPTA(09320) CHANDAN SINGH(09260) SCANNING ELECTRON MICROSCOPE MATERIAL SCIENCE ASSIGNMENT.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
X-Ray Diffraction Spectroscopy RAMAN Microwave. What is X-Ray Diffraction?
LECTURE 5 Principles of Electron Microscopy (SEM and TEM)
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
Scanning Electron Microscopy
Chapter 7 X-Ray diffraction. Contents Basic concepts and definitions Basic concepts and definitions Waves and X-rays Waves and X-rays Crystal structure.
Microanalysis in Science and Engineering - Electron Microscopy A Workshop for Middle and High School Teachers sponsored by Tennessee Technological University.
Nano-Materials Characterization Yoram Shapira, EE Nano-bio-electronics Growth and Processing Characterization and Analysis Design and Modeling.
Chapter 12 Atomic X-Ray Spectroscopy
Electron Microscopy 1 Electron Microscopy (EM) Applying Atomic Structure Knowledge to Chemical Analysis.
Scanning Electron Microscope (SEM) – Shoots a high energy beam of electrons (waves of electrons) at a target. Electron gun Focusing coil Objective lens.
Unknown at first, these photons from innershell transitions have played a vital role in materials analysis.
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/28/2006Chapter 6Electron Spectroscopy Chapter 6 Electron.
Scanning Electron Microscope (SEM)
16/1-13MENA3100 Probes used for analysis PhotonElectronNeutron Waves/particles UiOIFE Wave length Monochromatic Amplitude and phase Coherence.
X-Ray Diffraction Dr. T. Ramlochan March 2010.
PHYS 430/603 material Laszlo Takacs UMBC Department of Physics
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
CAMTECH 2011 Regi. High energy e - beam scans sample surface (Raster - line by line). Provides information about surface and near-surface atoms – topography.
Scanning capacitance microscopy
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
08/03/09 SEM signal generation
SEM Scanning Electron Microscope
X-ray diffraction and minerals. Is this mineral crystalline?
X-ray microanalysis in the electron microscope
Example of the output produced by XRF
X-Ray Diffraction Spring 2011.
The probe Some material used from:. EPMA - electron probe microanalysis Probe signals.
X-rays is a form of electromagnetic radiation having a wavelength in the range of 0.01 to 10 nanometers, corresponding to frequencies in the range 30.
Comparison b/w light and electron microscopes LIGHT MICROSCOPE ELECTRON MICROSCOPE Magnification can be done upto 2000 times Resolving power is less.
Methods of electron microscopy Electron microscopy is a collection of investigation methods. Microstructure of bodies (up to atom-molecule.
Scanning Transmission Electron Microscope
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Presentation on.  There are many methods for measuring of fiber structure. Such as:  The absorption of infrared radiation  Raman scattering of light.
Mohammed Zeeshan BT/PE/1601/ Microtexture: Electron Diffraction in the SEM Texture And Microstructure & Anisotropy.
Presentation on SEM (Scanning of Electron Microscope) Represented by:-Ravi Kumar Roll:- (BT/ME/1601/006)
Electron microprobe in Askja
INELASTIC SCATTERING AND BEAM DAMAGE
Laboratory equipment Lecture (3).
Introduction to Scanning Electron Microscope by Sameer S
NANO 230 Micro/NanoFabrication
TEM and SEM.
Do it with electrons !.
Electronics and Instrumentation Vidnyan Mahavidyalaya, Sangola.
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
Types of Microscopy Type Probe Technique Best Resolution Penetration
Scanning Electron Microscopy (SEM)
Radhabai Kale Mahila Mahavidhyalaya, Ppt. name:- x-Ray techniques
Surface analysis techniques part I
Presentation transcript:

Theory and Practice of Electron Microprobe Analysis Geoc 575 Nelia Dunbar Bureau Office B-101 x5783 office x5155 lab

Electron Microprobe analysis and Scanning Electron microscopy Electron microprobe analysis (EMPA) Analytical technique in which a beam of electrons is focused on a sample surface, producing X-rays from the material in the sample. Used for chemical mapping of a sample surface, and also for quantitative chemical analysis.

-Quantitative or qualitative chemical analysis of a very small focussed spot (<1um) on a polished sample surface. A non- destructive technique. Useful for: -Mineral identification -Descriptive petrology -Geothermometry and geobarometry -Experimental petrology -Cosmochemistry -Zoning in minerals -Diffusion studies -Particle analysis What is EMPA used for?

-Chemical mapping of a polished sample surface. Accomplished by sweeping (rastering) the beam over the sample surface. Used for many of the same types of studies described above. Particularly useful for: -Location and distribution of phases -Quick location and identification of trace particles -Subtle zoning patterns in mineral samples -Examination of the interfaces between phases What is EMPA used for? (con’t)

Secondary electron imaging (SEI, also commonly SEM) A related technique in which a very finely-focussed beam of electrons is swept across a sample surface, producing secondary electrons which are then detected by a scintillation detector. This technique is used for high-magnification and resolution imaging of a 3-D sample surface.

-Morphological imaging of a rough sample surface. Also accomplished by rastering the beam over the sample surface, but does only yields morphological, not chemical, information. Useful for: -Determining the morphology and morphological relationship between mineral phases that can be difficult to detect with the petrographic microscope -Determining size of very small mineral phases What is secondary electron imaging used for?

The instrumentation which allows these two types of analyses is closely related, in that the electron optics system is very similar. The CAMECA SX-100 instrument is primarily an electron microprobe designed for quantitative chemical analysis, but also can also be used for secondary electron imaging.

History of Electron Probe Microanalysis X-RAYS Roentgen discovers X-rays X-rays are high-frequency electromagnetic radiation with energy intermediate between far-UV and gamma ray regions. This leads to development in numerous fields, particularly medical Barkla recognized characteristic radiation This scientist recognizes that x-rays emitted from different elements produce x-rays of different energy and wavelength.

Moseley quantifies the relationship between atomic number and x-ray wavelength. Moseley photographed and studied characteristic x-ray radiation. He determined that the atomic number of an atom is more important than the atomic weight in determining the characteristics of x-rays generated from that element. Formulated Moseley's law: λ α 1/Z 2 where λ = x-ray wavelength Z = atomic number Von Laua. Diffraction Von Laua and coworkers speculated that wavelength of x-rays and crystal lattice parameters are similar, so x-rays could be diffracted by crystals.

1914- Bragg. Developed Bragg's Law Bragg's law defines a diffraction relationship between the wavelength of an incoming ray and the d-spacing of a diffracting crystal. Bragg's Law: n λ = 2d sinθ where n = the order of reflection λ = wavelength of incident ray d = interplanar spacing of the crystal θ = angle of incidence and reflection of incident ray This is the principle under which the wavelength-dispersive detectors operate.

1951 R. Castaing. Developed the first electron microprobe Castaing was a doctoral student at the University of Paris. His doctoral thesis was titled: "Application of electron beams to a method of local chemical and crystallographic analysis". He is the originator of the electron microprobe as we know it today.

Fundamental Beam Interactions

-Characteristic X-rays Produced by electronic transitions within inner electron shells. Can be explained by examining the Rutherford-Bohr model of the atom, in which electrons orbit in a number of shells around a nucleus. -Backscattered electrons Primary electrons from the beam that undergo violent collisions with atoms in the sample and are scattered back from the sample surface. The proportion of backscattered electrons is directly proportional to the mean atomic number of the sample. Backscatter from C is 8%, from U is 50%. Modern BSE detectors can detect mean Z differences of between 0.1 and 0.3 Z. -Secondary electrons Secondary electrons are produced by ionization of atoms in the sample by interaction with the primary beam. Secondary electrons have low energies, and cannot escape from deep within the sample. Therefore, this electron signal produces the highest-resolution morphological images of a sample surface.

-Cathodoluminescence Visible light emitted by minerals bombarded by electrons. Mechanism depends on the mineral in question. This property of certain minerals, particularly diamond and some types of feldspar, allow the beam to be viewed optically which is useful for focussing. -Continuous X-rays Most interactions between the primary beam do not produce the characteristic x-rays discussed earlier. Many electrons from the incident beam are simply decelerated by the interactions with outer orbital shell electrons from atoms within the sample. The energy released during these decelerations produces a continuous (or bremsstrahlung) x-ray spectrum. These x-rays are noise, and are undesirable, but unavoidable. -Auger Electrons When an atom is ionized in an inner shell, energy may be released by ejecting another bound electron, instead of producing an x-ray. These electrons can have characteristic energy. Most effective for low atomic number elements (<10).

-Characteristic X-rays Produced by electronic transitions within inner electron shells. Can be explained by examining the Rutherford-Bohr model of the atom, in which electrons orbit in a number of shells around a nucleus. From Reed, 1996

-Backscattered electrons Primary electrons from the beam that undergo violent collisions with atoms in the sample and are scattered back from the sample surface. The proportion of backscattered electrons is directly proportional to the mean atomic number of the sample. Backscatter from C is 8%, from U is 50%. Modern BSE detectors can detect mean Z differences of between 0.1 and 0.3 Z.

-Secondary electrons Secondary electrons are produced by ionization of atoms in the sample by interaction with the primary beam. Secondary electrons have low energies, and cannot escape from deep within the sample. Therefore, this electron signal produces the highest-resolution morphological images of a sample surface.

Electron interaction volumes Effect of beam interaction (damage) in plastic (polymethylmethacrylate), from Everhart et al., All specimens received same beam dosage, but were etched for progressively longer times, showing in (a) strongest electron energies, to (g) the region of least energetic electrons. Note teardrop shape in (g) From J. Fournelle

Major components of an electron microprobe 1. Electron optic system. -Electron gun -focussing lenses and apertures -associated electronics 2. Optical microscope and sample stage -optical/video apparatus for viewing sample -high-precision stage that holds samples and standards 3. X-ray optic system -spectrometers -secondary electron detector -backscatter electron detector -flow-proportional gas counters

Major components of an electron microprobe 4. Vacuum system -roughing pumps -diffusion pump -ion pump 5. Amplification/electronics -amplification of signals 6. Computer Controller -interface between instrument and operator -image collection and processing systems -quantitative data reduction programs