Measurement of flowing fluids

Slides:



Advertisements
Similar presentations
Objectives Velocity and flow measurement
Advertisements

DIFFERNETIAL PRESSURE FLOWMETERS
Unit Operation Lab K S Chou Ch E, N T H U 1. A: Fluid Flow Experiments A1 - Friction Coefficient in Tubes A2 - Flowmeters  Types of flowing fluid: gas.
FLOW measurements.
The Bernoulli Equation - Work and Energy
The Bernoulli Equation
Applications of the Bernoulli Equation. The Bernoulli equation can be applied to a great many situations not just the pipe flow we have been considering.
ENTC-303Dr. Alvarado1 Flow Measuring Devices. ENTC-303Dr. Alvarado2 Flowmeters Devices used to measure flow rate: –Venturi (based on pressure difference)
1 Lec 26: Frictionless flow with work, pipe flow.
Bernoulli ’ s Equation. Outline The Energy Balance for a Steady Incompressible Flow The Friction Heating Term Bernoulli ’ s Equation The Head Form Diffusers.
Volume Flow Measurements. Obstruction Meters u Orifice Meters u Venturi Meters u Flow Nozzles.
Fluid mechanics 3.1 – key points
Flow Measurement M. Shahini.
Chapter Five Flow Measurement
Flow Sensors.
CBE 150A – Transport Spring Semester 2014 Flow Measurement and Control.
Fluid Mechanics 05.
ME 322: Instrumentation Lecture 12
Chapter 15B - Fluids in Motion
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement.
Unit Operation Lab K S Chou Ch E, N T H U 1. A: Fluid Flow Experiments A1 - Friction Coefficient in Tubes A2 - Flowmeters  Types of flowing fluid: gas.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Pipeline systems.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
SURVIVAL MODE Quiz 3 –
Chapter 21 Theoretical Rates in Closed-Channel Flow.
APLIKASI BERNOULLI PADA
R. Field 10/29/2013 University of Florida PHY 2053Page 1 Ideal Fluids in Motion Bernoulli’s Equation: The Equation of Continuity: Steady Flow, Incompressible.
Energy Consideration in Steady Flow
Lecture 2 Single Phase Flow Concepts
Venturi Meter By Alex Turner & Mick Lock. What is it? A pipe that has a cone that narrows and then gradually returns to the original diameter of the pipe.
Example 1 Velocity measurement by a Pitot tube
FLUID DYNAMICS BERNOULLI’S EQUATION BY GP CAPT NC CHATTOPADHYAY.
Flow Measurement and Control. Orifice Meter The orifice meter consists of an accurately machined and drilled plate concentrically mounted between two.
Chapter 6: Bernoulli and energy equations
Lesson 22 BERNOULLI’S EQUATION
T W DAVIES1 CONSERVATION OF MECHANICAL ENERGY FRICTIONLESS FLOW ALONG A STREAMLINE MECHANICAL ENERGY BALANCE ON A UNIT MASS OF FLUID –POTENTIAL ENERGY.
Flow Measurement and Control
Flow measurement.
Fluids in Motion.
Flow In Circular Pipes Objective ä To measure the pressure drop in the straight section of smooth, rough, and packed pipes as a function of flow rate.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.

Statika Fluida Section 3. Fluid Dynamics Objectives Introduce concepts necessary to analyse fluids in motion Identify differences between Steady/unsteady.
Thermo-aero Dynamic Analysis of Wind Turbines P M V Subbarao Professor Mechanical Engineering Department Development of Characteristic Design Variables.
Flow Through A Small Orifice. Velocity can be predicted at the orifice using the Bernoulli equation between points 1 & 2. Notice that u 1 at the surface.
Basic Hydraulics: Energy and Momentum concepts. Energy of flow Three kinds of energy gradients cause flow Elevation (called potential energy) Pressure.
Flow of Compressible Fluids. Definition A compressible flow is a flow in which the fluid density ρ varies significantly within the flowfield. Therefore,
GOVERNMENT ENGINEERING COLLEGE, BHARUCH (014) Chemical Engineering department SEM-iii Sub: fluid flow operation topic: orifice meter & rotAmeter Guid by:
Energy Equation The expanded Bernoulli's equation
aNamePEN no 1.Harsh Patel Prince Patel Ronak Trivedi Yusuf Khan Guided by: M. M. Chhatbar Subject:
Phil. U., M Eng Dep., Measurements, Chap#7 flow measurements is very important as it covers wide ranges of applications. The flow rate measurement devices.
SUB:-FLUID MECHANICS TOPIC:-FLOW MEASUREMENT DEVICES SUBMITTED TO: KULDEEP SIR Government engineering college, valsad.
VENTURIMETER Department of Chemical Engineering
UNDERSTANDING DIFFERENT
1 Dept. of Agricultural & Biological Engineering University of Illinois TSM 363 Fluid Power Systems TSM 363 Fluid Power Systems Bernoulli’s Law and Applications.
Week 1 Unit Conversions Conservation of Mass Ideal Gas
Consequence Analysis 1.2.
SIGMA INSTITUTE OF ENGINEERING
Energy Loss in Valves Function of valve type and valve position
ABE 223 ABE Principles – Machine systems Bernoulli’s Law Tony Grift
Measurement of discharge
Piyush Modi Assist.Prof
PREAPRED BY : SAKARVADIYA JAY
g.h.patel collage of engineering and technology
Bernoulli’s Equation (Mechanical Energy Balance)
Bernoulli’s Equation (Mechanical Energy Balance)
Measuring Fluid Flow Rate,
FLUIDS IN MOTION The equations that follow are applied when a moving fluid exhibits streamline flow. Streamline flow assumes that as each particle in the.
Subject Name: FLUID MECHANICS
Flow Measurements.
Presentation transcript:

Measurement of flowing fluids Variable head meters Variation of flow rate thro a constant area generates a variable pressure drop which is related to the flow rate Venturi meter Orifice meter Variable area meters Consists of devices in which the pressure drop is constant, or nearly so, and the area thro which the fluid flows varies with the flow rate. The area is related, thro proper calibration, to the flow rate Rotameter

Venturi meter

In this meter the fluid is accelerated by its passage through a converging cone of angle 15º-20º. The pressure difference between the upstream end if the cone and the throat is measured and provides the signal for the rate of flow. The fluid is then retarded in a cone of smaller angle (5º-7º) in which large proportion of kinetic energy is converted back to pressure energy. The attraction of this meter lies in its high energy recovery so that it may be used where only a small pressure head is available, though its construction is expensive.

Although venturi meters can be applied to the measurement of gas, they are most commonly used for liquids. The following treatment is limited to incompressible fluids. The basic equation for the venturi meter is obtained by writing the Bernoulli equation for incompressible fluids between the two sections a and b. Friction is neglected, the meter is assumed to be horizontal. If va and vb are the average upstream and downstream velocities, respectively, and r is the density of the fluid, vb2 - va2 = 2(pa - pb)/r ---1

The continuity equation can be written as, va = (Db/Da)2 vb = b2 vb --- 2 where Da = diameter of pipe Db = diameter of throat of meter b = diameter ratio, Db/Da If va is eliminated from equn.1 and 2, the result is (3)

Equn.3 applies strictly to the frictionless flow of non-compressible fluids. To account for the small friction loss between locations a and b, equn.3 is corrected by introducing an empirical factor Cv. The coefficient Cv is determined experimentally. It is called the venturi coefficient, For a well designed venturi, the constant Cv is about 0.98 for pipe diameters of 2 to 8 inch and about 0.99 for larger sizes.

Volumetric flow rate: The velocity through the venturi throat vb usually is not the quantity desired. The flow rates of practical interest are the mass and volumetric flow rates through the meter. Volumetric flow rate is calculated from, Q = Abvb and Mass flow rate = volumetric flow rate x density

Orifice Meter The venturi meter described earlier is a reliable flow measuring device. Furthermore, it causes little pressure loss. For these reasons it is widely used, particularly for large-volume liquid and gas flows. However this meter is relatively complex to construct and hence expensive. Especially for small pipelines, its cost seems prohibitive, so simpler devices such as orifice meters are used.

Orifice Meter

The orifice meter consists of a flat orifice plate with a circular hole drilled in it. There is a pressure tap upstream from the orifice plate and another just downstream. The principle of the orifice meter is identical with that of the venturi meter. Bernoulli's equation provides a basis for correlating the increase in velocity head with the decrease in pressure head.

Similar to venturi meter……… where…. b= (orifice dia / tank dia) Co = orifice coefficient (0.51-0.61)

THANK UUUUU