Quality Assurance/ Quality Control

Slides:



Advertisements
Similar presentations
Why Lab. Certification? Laboratory certification tries to insure that the laboratory is qualified and capable of analyzing the sample and obtaining quality.
Advertisements

Quality is a Lousy Idea-
April 7: QA Systems, EPA definitions, PQAOs and common sense – Mike Papp April 14: Routine Quality Control and Data Management (1-pt QC, flow rate, and.
Assessing Laboratory Quality – Systematic Bias Robert O. Miller Colorado State University Fort Collins, CO.
QA Strategy Workgroup Ambient Air Quality System Training Ambient Air Monitoring Quality Systems Requirements Mike Papp- OAQPS.
Why do we lose analyzer data? Monitor malfunction DAS malfunction Power outages Environmental problems Wildlife damage Vandalism Operator error.
Louisiana Department of EnvironmentalQuality LDEQ CAM Plan Overview LDEQ’s 27 th Annual Conference on the Environment Cajundome Convention Center Lafayette,
SRPMIC Ozone Monitoring Sites Senior Center SiteHigh School Site Red Mountain Site Lehi Site.
Lecture 8. Quality Assurance/Quality Control The Islamic University of Gaza- Environmental Engineering Department Environmental Measurements (EENV 4244)
AQS Concepts. In This Section We Will Talk About AQS Concepts 2 AQS Background History AQS as part of a monitoring program Types of Information in AQS.
Short Course on Introduction to Meteorological Instrumentation and Observations Techniques QA and QC Procedures Short Course on Introduction to Meteorological.
Quality Assurance/Quality Control Policy
Quality Assurance Plans (QAP)
QA/QC FOR ENVIRONMENTAL MEASUREMENT
Method Comparison A method comparison is done when: A lab is considering performing an assay they have not performed previously or Performing an assay.
1 Guest Speaker: Bill Frietsche US EPA.  April 7: QA Systems, EPA definitions, PQAOs and common sense – Mike Papp  April 14: Routine Quality Control.
Presented by: Mike Hamdan South Coast Air Quality Management District Diamond Bar, CA Presented at: The Tribal Air Monitoring Training, Pechanga Reservation,
Guest Speaker: Jeremy Howe Little River Band Of Ottawa Indians The Measuring Sticks of Air Monitoring.
Field Analysis Quality Control
What to compare against the validation templates (see templates in course webpage: Resources/Validation%20Templates%20from%20Red.
Ensuring of Traceability
EPA Precursor Gas Training Workshop Precursor Gas Quality Assurance Implementation Dennis K. Mikel EPA Office of Air Quality Planning and Standards.
Introduction to BGI Instruments
Institute for Tribal Environmental Professionals Tribal Air Monitoring Support Center Melinda Ronca-Battista Brenda Sakizzie Jarrell Southern Ute Indian.
1 Dec. 8, 1997 LEADS Quality Assurance Summary Robert Brewer (512) Monitoring Operations Division Network QA Manager.
AMP255 – Precision and Bias Data Report 2008 AQS Conference The AMP255 Precision and Bias Data Report August 22, 2008 Presented by Jonathan Miller EPA.
Introduction to Standard Reports. Standard Reports 2 How to get information out of AQS Standard Reports Site / Monitor Metadata Detail Data Reports “
Melinda Ronca-Battista, ITEP, TAMS Center Tribal Air Monitoring and QA Requirements for NAAQS- Comparable Data.
HD 2007 Rule Diesel Fuel Sulfur Testing and Sampling Methods and Requirements US EPA Office of Transportation and Air Quality November 20, 2002.
Quality WHAT IS QUALITY
1 Guest Speaker: Brandy Toft Leech Lake Ojibwe.  Overview of FRM/FEM/ARM status, requirements, and reporting  QC (routine checks, audits, and method-
Tribal Air Quality “Tools of the Trade” Lydia Scheer, ITEP.
 April 7: QA Systems, EPA definitions, PQAOs and common sense – Mike Papp  April 14: Routine Quality Control and Data Management (1-pt QC, flow rate,
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheWorkshop European Standards Requirements of.
Quality Control/ Quality Assurance Annabelle Allison ITEP/TAMS Center.
Quality Control – Part II Tim Hanley EPA Office of Air Quality Planning and Standards.
Emission Inventory Quality Assurance/Quality Control (QA/QC) Melinda Ronca-Battista ITEP/TAMS Center.
EPA Region 9 Meredith Kurpius August 19, Status of Tribal Air Monitoring Value of tribal monitoring Used to protect public health on tribal land.
Appendix A: Calculations for Data Quality Assessment QC check statistics Precision calcs Bias calcs PM stats Reporting: quarterly and annual.
Small-Group Activity: NAAQS Exercise Nate Herbst Southern Ute Indian Tribe.
CARB Continuous PM 2.5 Monitoring Activity (BAM’s) Reggie Smith California Air Resources Board.
Data Submittals to AQS Nate Herbst Southern Ute Indian Tribe.
1 Quality Assurance Project Plans Melinda Ronca-Battista, ITEP/TAMS Center.
1 Dec. 11, 1997 LEADS Quality Control Systems Robert Brewer (512) Monitoring Operations Division Network QA Manager.
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheBukarest National Reference Laboratory for Air.
Data Management Concepts James Payne Environmental Protection Department Morongo Band of Mission Indians.
Chapter 10 Verification and Validation of Simulation Models
An Overview of EPA’s Quality Assurance Guidance for Ambient Air Quality Monitoring Data Data Analysis and Interpretation February 12 – 14, 2008, Tempe,
 April 7: QA Systems, EPA definitions, PQAOs and common sense – Mike Papp  April 14: Routine Quality Control and Data Management (1-pt QC, flow rate,
LEADS/EMS DATA VALIDATION IPS MeteoStar December 11, 2006 WHAT IS VALIDATION? From The Dictionary: 1a. To Make Legally Valid 1b. To Grant Official.
Data Management Concepts James Payne Environmental Protection Department Morongo Band of Mission Indians.
Method 203 Quality Assurance/Quality Control Requirements for Continuous Opacity Monitoring Systems (COMS)
Measurement Quality Objectives = Data Validation Requirements Excerpted from EPA QA Handbook Volume II (aka “Redbook”)
PM 2.5 Continuous FEMs; Update and Assessments For NESCAUM Monitoring Meeting April 29, 2011 Tim Hanley – US EPA, OAQPS 1.
WHAT IS THE CHEROKEE NATION? Cherokee Nation Air Quality Data Management Concepts for Quality Data Collection Ryan Callison.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Module 11 Module I: Terminology— Data Quality Indicators (DQIs) Melinda Ronca-Battista ITEP Catherine Brown U.S. EPA.
Quality is the totality of features and characteristics of product or services that bear on its ability to satisfy the stated needs.  In simple words.
Annual Air Monitoring Data Certification and Concurrence Process 1.
Statewide Compliance Monitoring and Local Monitoring Projects
Quality Assurance.
Quality is a Lousy Idea-
HOPI TRIBE-DEPARTMENT OF NATURAL RESOURCES Hopi Environmental Protection Office (HEPO) Air Quality Program.
Calibration Calibration of the analyzer establishes the relationship between actual pollutant concentration input and the analyzer response. Should be.
Chapter 10 Verification and Validation of Simulation Models
Quality is a Lousy Idea-
Proposed Ozone Monitoring Revisions Ozone Season and Methods
Quality Control Lecture 3
QA/QC Gaseous Pollutants mini-course TAMS Center February 2009.
Precision, Bias, and Total Error (Accuracy)
Presentation transcript:

Quality Assurance/ Quality Control Nate Herbst Southern Ute Indian Tribe

Intro to QA/QC Getting good data requires many different steps Data quality objectives (DQOs) developed DQOs for ozone being developed Measurement quality objectives (MQOs) for ozone exist Analysis begun (after correct calibration) QC checks performed QA conducted

Data Quality Objectives (7 steps) State problem Define why monitoring is needed Create team and purpose Identify decision What decision will be made with data? Identify decision inputs What data necessary to make decision? Define boundaries What are study area boundaries?

Data Quality Objectives (cont.) Develop decision rule What conditions will require action (action level)? Specify decision error limits What margin of error is allowable Optimize monitoring design Develop most cost-effective method of reaching DQOs EPA hasn’t yet defined DQOs for ozone analysis

DQOs (cont.) Diagram of DQO steps (Diagram courtesy of U.S. Department of Energy – DQO homepage)

Measurement Quality Objectives (MQOs) Thanks to Melinda Ronca-Batista (ITEP) EPA has ozone analysis MQOs Use these in element 7 of your QAPP MQOs in a nutshell Shelter temperature kept between 20-30oC ± 2oC Analyzer must be reference or equivalent method Lower detectable limit 0.01ppm, noise 0.005ppm Data completeness 75% of hourly values between 9:01am and 9:00pm (for the ozone season) Transfer standard certification ±4% or 4ppb (whichever is greater)

MQOs (cont.) Transfer standard re-certification to primary std.dev 1.5% Local primary standard certification ±5% of reference EPA reference photometer regression slope 1.00 ± 0.01 Zero air free of O3 and anything that might react with O3

MQOs (cont.) Ozone analyzer calibration Z/S check zero ±10ppb, span ± 15% 5pt calibration linearity error ±5% Performance (NPAP) mean absolute difference ± 15% Precision (quarterly) 95% CI < ±15% Audits (annually) 95% CI < ±20%

Quality Assurance Project Plans (QAPPs) Contain 24 “elements” Element 7 is where MQOs go Cut and paste from red book Ensure data quality Required by EPA Developed by program approved by EPA They must be followed! No good if not followed

Documentation Document everything!!! Documentation in Logbooks Site folders QA/QC field forms Anywhere else you think is appropriate QA/QC – document standard values and response

Documentation (cont.) Document repairs, checks, fine tunes Document site conditions Document everything that could ever be important Write only in pen (black if possible) Cross out errors with a single line

Linearity Slope = rise over run m = slope b = intercept (where the trend-line crosses the Y axis) r2 close to 1 shows correlation

Instrument Calibration Measurements require point of reference Measurement without standard is impossible Calibration involves setting instrument to known level Calibrations performed fairly regularly When monitoring is begun When repairs or maintenance are performed When precision checks or audits show need Calibrations must be done correctly

monitoring without calibration Calibrations (cont.) Calibration = setting analyzer to standard Data only good within linear range (~0-0.400ppm) Calibration followed by a 5-pt check Analyzer must agree with standard at all 5 pts Linearity error < 5% See next slide on linearity Monitoring begins after calibration Note: Never initiate monitoring without calibration

Pre-Calibration Check Not always necessary Can do 5-pt check Analyzer must be calibrated The r2 value and % differences for each point are unacceptable

Instrument Calibration Calibrate instrument to the standard Use calibration point near URL Setting low produces large error at URL Set standard to ~0.400 ppm Let analyzer stabilize Calibrate analyzer Do new 5-pt check

Post-Calibration 5-pt Check Is analyzer response within 7% at each point? Would you put this analyzer online?

Quality Control (QC) QC involves “in-house” verifications Also referred to as precision checks Verifications are comparisons between transfer standard and analyzer Relative % difference within allowable margin? Verifications determine monitoring repeatability Standard deviation Different types of verifications

QC (cont.) Level 1: 40 CFR, Pt. 58, App. A, Table A-1 defines ozone verification requirements (for SLAMS) Biweekly response check between 0.08 and 0.1 ppm Comparison between analyzer and standard Determines repeatability Level 2: “extra” precision checks Weekly “span level” (~80% URL) checks Quarterly 5-pt checks Determines analyzer performance trends

Quality Assurance (QA) QA involves “external” checks Referred to as “audits” Audits involve comparison between transfer standard and analyzer Accuracy levels must be within ±10% Audits determine how close monitoring gets to actual values Different types of audits

QA (cont.) 40 CFR, Pt. 58, App. A, Table A-1 defines ozone audit requirements (for SLAMS) Annual (and other) response checks at multiple points 0.03-0.08 ppm 0.15-0.2 ppm 0.35-0.45 ppm Comparison between analyzer and external standard Audits should include zero check

QA (cont.) Different types of audits By reporting organization (RO) certified by RO By RO certified by other than RO By other than RO certified by other than RO

Precision & Accuracy (P&A) Data Precision data come from biweekly precision checks Accuracy data come from annual and other audits P&A data validate ambient data P&A data must be included in AQS data submittals

Siting Criteria Data quality depends on correct siting of all instrumentation Specific instrument siting guidelines Following guidelines is vital part of quality assurance and control We’ll learn more about these guidelines in the next presentation

Summary Establish DQOs Develop QAPP Follow your QAPP Get it approved by EPA Follow your QAPP Conduct bi-weekly precision checks Conduct level 2 checks to follow monitor trends Participate in annual audits and others if possible Data quality will be guaranteed